Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹47.1 LAccepted-AOC STATION ROAD POST RANGIYA DIST KAMRUP ASSAM PIN 781354 | KAMRUP | ASSAM | 781354 | L1 | Accepted-AOC RATES ARE FOUND REASONABLE AND THE FIRM BEING L1 BIDDER | |
| 2 | L2₹48.8 L+₹49,137 (1.02%)Rejected-Finance C O DR UMASHANKAR SHARMA RANGIYA TINIALI NEAR RAIL GATE POST RANGIYA DIST KAMRUP ASSAM PIN 781354 | KAMRUP | ASSAM | 781354 | L2 | Rejected-Finance BEING L2 BIDDER | |
| 3 | L3₹49.0 L+₹70,412.40 (1.46%)Rejected-Finance RZ 50D GALI NO 13 VASHISHT PARK PANKHA ROAD NEW DELHI 110046 | NEW DELHI | DELHI | 110046 | L3 | Rejected-Finance BEING L3 BIDDER | |
| 4 | L4₹49.0 L+₹73,864 (1.53%)Rejected-Finance C O SHRI AMRENDER KUMAR YADAV IACHHIPUR SANTOSH NAGAR GORAKHNATH GORAKHPUR UTTAR PRADESH PIN 273015 | GORAKHPUR | UTTAR PRADESH | 273015 | L4 | Rejected-Finance BEING L4 BIDDER | |
| 5 | L5₹49.3 L+₹96,806 (2.00%)Rejected-Finance | L5 | Rejected-Finance BEING L5 BIDDER |
Tender Value
₹48.5 L
EMD Value
₹97,200
Closing Date
26 Feb 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Rangia
GE Rangia C/O 99 APO Rangia
SPL REP TO BLDG NO ET-68 DARRANGA AND ET-128 TAMULPUR
2024_MES_640954_1
8766/E8
Open Tender
Civil Works
Item Rate
180 days
Darranga and Tamulpur
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
GE Rangia
₹97,200
Yes
26 Mar 2024
6 Feb 2024
28 Feb 2024
6 Feb 2024
26 Feb 2024
21 Feb 2024
6 Feb 2024 - 13 Feb 2024
Amount
Taking down Chowkhats or frames with shutters (without taking off shutters from the frames) not exc. 1.5 sq. m each, complete all as specified and as directed by Engineer-in-charge.
Taking down Chowkhats or frames with shutters (without taking off shutters from the frames) exc 1.5 sq. m but not exc. 4.0 sq. m each, complete all as specified and as directed by Engineer-in-charge.
Dismantling Asbestos cement (corrugated, semi-corrugated, etc.) sheets in roof coverings, complete all as specified and as directed by Engineer-in-charge.
Dismantling wrought iron or mild steel work of any description not otherwise provided for, complete all as specified and as directed by Engineer-in-charge.
Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc., complete all as specified and as directed by Engineer-in-charge.
M& L for Excavation in trenches n.exc 1.5m wide and n.exc 1.5 m in depth for foundation etc or for shafts, wells, cesspits, manholes, pier holes etc. and getting out in soft/loose soil complete all as per specified and as directed by Engineer-in-charge.
M&L for Returning, filling in, including spreading, leveling, watering and well ramming in layers n exc 25cm complete all as per specified and as directed by Engineer-in-charge.
M&L for Removing excavated material not exc. 50 m & depositing where directed at a level not exc. 1.5 m above starting point complete all as per specified and as directed by Engineer-in-charge.
M&L for sand filling under floors or in foundations spreading and levelling in layers not exc. 25 cm thick including watering and consolidation or Sand Cushioning (dry) in trenches/ducts for protection of UG Cables (below, above and around the UG Cable laid in Trenches) of 230mm Spread thickness (8 Cm in depth before laying the Cable and 15 Cm in depth after laying the Cable) and consolidated (punned) upto 180mm thickness, complete all as per specified and as directed by Engineer-in-charge. NOTE : For the purpose of Payment, Punned thickness of Sand Cushioning only will be measured and paid for.
M&L for Hardcore with broken stones/ boulders of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface, complete all as specified and as directed by Engineer-in-charge.
M&L for Providing precast cement concrete louvres and jallies, 40mm thick (measured solid), including all mouldings but excluding frame of Type B-0, 1:2:4 (12.5mm graded aggregate) set in cement morter 1:4, complete all as specified and as directed by Engineer-in-charge.
M&L for Reinforced Cement Concrete, (Nominal Mix) 1:2:4, type B-1 (20mm graded stone aggregate) in Beams, cantilevers, lintels over 1.5m span, Chajjas including demolition of existing old damaged RCC structure, complete all as specified and as directed by Engineer-in-charge. NOTE : Reinforcement & Formwork will be measured and paid separately under relevant Item.
M&L for Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter, sides of pillars, posts, struts, piers, columns, sides and soffits of floor or roof beams, lintels, Chajjas, rough finished flat surfaces of concrete, complete all as specified and as directed by Engineer-in-charge.
S&F of TMT bars 8mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified and as directed by Engineer-in-charge.
S&F of TMT bars 6-8mm dia, cut to length, bent to shape required, in stirrups, spacers and binders and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified and as directed by Engineer-in-charge.
S&F of Mild Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240, complete all as specified and as directed by Engineer-in-charge.
All as per Item No. 16 here-in-above, but for erection & febrication only, complete all as per specified and as directed by Engineer-in-charge.
S&F of mild steel Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165, complete all as specified and as directed by Engineer-in-charge.
S&F of Solid PVC moulded Double Door Frame of size 120mm x 50mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube; complete all as specified and as directed by Engineer-in-charge.
S&F of Steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded, complete all as specified and as directed by Engineer-in-charge.
S&F of Steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete without glazing bars, dovetailed or welded, complete all as specified and as directed by Engineer-in-charge.
S&F of Steel ventilator with top hung shutter including hinges, steel peg stay, complete all as specified and as directed by Engineer-in-charge.
S&F of Factory made wire gauzed panel PVC moulded door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; wire gauze shall be wrapped on an additional square 8mm M.S. Solid tube and this tube shall be welded to M.S. tubes. The wire gauge shall be stretched to tighten firmly; complete all as specified and as directed by Engineer-in-charge. (NOTE- Cost of wire mesh shall deemed to be included in unit quoted rate.)
S&F of Factory Made Solid PVC Moulded Door Shutter With Particle Board Core, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick Moulded PVC Sheet on the front face & 2mm plain colour PVC sheet on back face; complete all as specified and as directed by Engineer-in-charge.
S&F of 125 mm long Butt hinges, extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed, type C-21, complete all as specified and as directed by Engineer-in-charge.
S&F of 200 mm long Extruded aluminium alloy handles, fabricated type, anodised, complete all as specified and as directed by Engineer-in-charge.
S&F of 200 mm long Aluminium anodised, barrel tower bolts of extruded section, complete all as specified and as directed by Engineer-in-charge.
S&F of 300 mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy, complete all as specified and as directed by Engineer-in-charge.
S&F of 3mm thick Sheet glass, ordinary quality and glazing with oil putty in square n exc 0.5 sq. m in each pane, complete all as specified and as directed by Engineer-in-charge.
S&F of Mild steel 300mm long, ordinary rat tail rod pattern springs including roller and roller plate, complete all as specified and as directed by Engineer-in-charge.
M&L for Brickwork with subclass ‘B’ bricks, straight or curved on plan to any radius built and set in cement mortar 1:6, incl demolition of existing B/W,complete all as per specified and as directed by Engineer-in-charge.
M&L for Brickwork with subclass ‘B’ bricks, straight or curved on plan to any radius in half brick thick walls built and set in cement mortar 1:4, incl demolition of existing B/W, complete all as per specified and as directed by Engineer-in-charge.
M&L for Rendering 10mm thick in cement morter 1:6 on other than fair faces of brick work or concrete surfaces/ other side of lathing, finished even and smooth without using extra cement, complete all as specified and as directed by Engineer-in-charge.
M&L for Rendering (Externally) 15mm thick in Cement Mortar 1:4 on fair faces Brick Walls/Concrete Surfaces/ one side of lathing, plastered surfaces finished Even and Smooth without using Extra Cement, complete all as specified and as directed by Engineer-in-charge.
M&L for providing 75 mm thick Cement concrete type C-2, 1:3:6 (40mm graded stone aggregate) as in floor/ path/ hardstanding/plinth protection, etc. or similar works, laid in altenate bays including use and waste of form work and finishing concrete surfaces even and fair including demolition of existing old unserviceable concrete, complete all as per specified and as directed by Engineer-in-charge.
M&L for providing 100 mm thick Cement concrete type D-2, 1:4:8 (40mm graded stone aggregate) as in sub-base of floor/ path/ hardstanding/plinth protection, etc. or similar works, laid in altenate bays including use and waste of form work and finishing concrete surfaces even and rough, complete all as per specified and as directed by Engineer-in-charge.
M&L for providing 40 mm thick Cement concrete type B-1, 1:2:4 (20mm graded stone aggregate) as in floor/ path/ hardstanding/plinth protection, etc. or similar works, laid in altenate bays including use and waste of form work and finishing concrete surfaces even and smooth using extra cement including demolition of existing old damaged PCC flooring, complete all as per specified and as directed by Engineer-in-charge.
M&L for providing 38mm wide glass dividing strips, 3mm thick, inserted in position, conform to design, complete all as specified and as directed by Engineer-in-charge.
M&L for providing glossy finished PU coated Chequered cement concrete coloured tiles 30cm x 30cm x 25mm thick, set, jointed and pointed in neat cement slurry in floors., laid over 20mm thick cement screed 1:6 with grey cement and pigments to match, complete all as per specified and as directed by Engineer-in-charge.
S&F in-repair of exposed powder coated GI snap grid frame work (600x600 mm) for false ceiling comprising of wall/cleat angle of size 25x25x0.35mm and cross tee of size 24x38x0.70mm with suspended hangers of 2 mm dia. G.I. (upto 1200mm length) adjusting level fixed to any type of roof by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long with and including supplying & fixing/ laying/ inserting of pre-painted (white) 4mm thick designer classic E-boards (595x595 mm) to GI frame work, complete all as specified and as directed by Engineer-in-charge.
S&F of 0.50mm thick Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws, complete all as specified and as directed by Engineer-in-charge.
S&F of 0.50mm thick Pre-painted galvalume aluminum zinc coating GI based plain steel sheet of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws, complete all as specified and as directed by Engineer-in-charge.
M&L for preparing newly plastered surfaces of wall and applying three coats of white wash, complete all as specified and as directed by Engineer-in-charge.
M&L for preparing newly plastered surfaces of wall and applying two coats of distemper oil emulsion of any shade over a coat of chalk whitening and a coat of avg 2.00mm thick wall care putty including rubbing down the putty surfaces to obtained smooth finish, complete all as specified and as directed by Engineer-in-charge.
M&L for preparation of new or previously un-treated steel/iron surfaces of any description, not otherwise described, over 10cm width or girth and applying two coats of Synthetic enamel paint (1st quality) of any tint over a coat of red oxide primer, complete all as specified and as directed by Engineer-in-charge.
S&F of 140 mm Overall length of cover plate Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring and rubber end, fixed in floor, complete all as specified and as directed by Engineer-in-charge.
M&L for point wiring with 1.5 sqmm size (nominal area) PVC insulated unsheathed single core multi stranded FRLSH copper conductor cable drawn into and incl PVC casing capping sleeves and caps of adequate width and length with all accessories and fittings like bends, elbow, crosses, etc. with PVC round block and PVC terminal boxes with 3.00mm thick laminated sheet cover for mounting fittings like; switches, sockets, fan regulator, etc. incl 1.5 sqmm size PVC insulated multistranded FRLSH copper conductor cable as earth continuity conductor and connected to earth dolly for one light/ fan/ exhaust fan/ bell point controlled by one 1-way switch/ bell push, including taking down the existing old unserviceable wiring connection with casing-capping/ conduit/ batten and switch board of any description with and including making good the disturbed surfaces (as/if requred), complete all as per specified and as directed by Engineer-in-Charge.
All as per Item No. 47 here-in-above, but for One 3 pin socket outlet, 5 Amps on the same board, complete all as specified and as directed by Engineer-in-charge.
All as per Item No. 47 here-in-above, but for One 3 pin socket outlet, 5 Amps, independent board, complete all as specified and as directed by Engineer-in-charge.
All as per Item No. 47 here-in-above, but for One 3 pin socket outlet, 15 Amps, independent board, with cables 4 sq. mm size, complete all as specified and as directed by Engineer-in-charge.
S&F of Switch piano, flush type single pole, One way 5/6 Amp, 220-240V, AC, complete all as specified and as directed by Engineer-in-charge.
S&F of Socket outlet 3 pin, 5/6A, flush type, 220-240V, AC, complete all as specified and as directed by Engineer-in-charge.
S&F of Switch socket combination 2 in 1, 3/5Pin, 5/6A flush type, 220-240V, AC, complete all as specified and as directed by Engineer-in-charge.
S&F of Switch socket combination 2 in 1, 5/6 pin, 15/16 Amp, flush type universal, 220-240V, AC, complete all as specified and as directed by Engineer-in-charge.
S&F of ceiling rose surface backelite three terminals, PVC/ polycarbonate, insulated body, complete all as specified and as directed by Engineer-in-charge.
S&F of stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc. as reqd., 220-240V, AC, complete all as specified and as directed by Engineer-in-charge.
S&F in-repair of Sheet Metal Enclosure MCB DB SPN, 8 way 240 volt, with rated Bus-bar, Double door type MCB DB suitable for mounting incoming and outgoing MCBs of any type, complete all as specified and as directed by Engineer-in-charge.
S&F in-repair of MCB Single Pole & Neutral (SPN), 'C' Curve, 40 Amps, 240 Volt for fixing on MCB DB’s, 10 KA, 50 Hz, conforming to IS/IEC 60898, connecting up and testing, complete all as specified and as directed by Engineer-in-charge.
S&F in-repair of MCB Single Pole (SP), 'C' Curve, 6-32 Amps, 240 Volt for fixing on MCB DB’s, 10 KA, 50 Hz, conforming to IS/IEC 60898, connecting up and testing, complete all as specified and as directed by Engineer-in-charge.
S&F in-repair of surface and wall mounted LED tube light fitting 1x 22W, (4 Feet) with aluminium housing & integrated electronic driver, 6500K, 220-240 Volts, AC decorative box type with and including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose to fitting, complete all as specified and as directed by Engineer-in-charge.
S&F in-repair of bracket suitable for LED Street light fitting/ house service bracket made out of 25mm bore (Dia) light grade GI pipe of 1.0m long, bend to required shape, including necesary clamps (Mild Steel Flat iron of 50x6mm) for fixing of building security/ street light fitting as per existing and painting the MS Flat iron with two coats of synthetic enamel paint, complete all as specified and as directed by Engineer-in- Charge.
S&F in-repair Energy saving new generation environmental friendly long life versatile presure die cast aluminium housing IP 66 building security light fitting luminaire with high power LEDs as light source and electronic driver of capacity 35 watts with pre wired and lens embedded PC cover having Bottom opening seperate driver compartment and Impact resistance of IK08 with necessary mounting arrangements, complete all as specified and as directed by Engineer-in-charge.
S&F in-repair of ceiling fan hook made out of MS Flat Iron of 50x6mm thick with and including 12mm dia round bar bend to required shape and nut-bolt-washer and painting the MS Flat iron/ round bar/ nut-bolt-washer with two coats of synthetic enamel paint, complete all as specified and as directed by Engineer-in-charge.
M&L for earthing complete with galvanised steel earth plate electrode of size 600 mm x 600 mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below ground level, connected to galvanized earth wire 4.00 mm dia by means of bolts nuts check nuts & washers of galvanized iron or steel , procteded by GI pipe 15 mm bore( light grade) and watering pipe 20 mm bore GI pipe (medium grade) and chamber and coping shall be in PCC 1:3:6 type C1 using 20mm graded stone agg. 50 mm thick cover of RCC 1:2:4 type B1 using 20 mm graded stone agg. reinforced with 8 mm dia MS tor bar @ 80 mm c/c both ways including excvation and earth work and removal of surplus soil complete all as shown in electrical plate no 3 of SSR PT 1, 1991 with charcoal dust and salt complete and earth lead connected to earthing test point (up to main switches, DBs) including taking down existing old damaged earthing, complete all as specified & testing on completion. NOTE:- (i) Item includes the cost of 1.5 mtr length GI pipe for protection for GI earth wire. (ii) Item rates includes the cost of 7.5 mtr earth lead GI earth wire.
Supply & laying in-replacement of LT XLPE insulated cable, sheathed, screened, PVC bedded, Galvanised Steel Strip or Wire armoured, Electic Power Cable (heavy duty) with Aluminium Conductor, 1100 Volts grade, cross-sectional area 16 Sqmm 2 Core, laid in Pipe/ Ducts/ Trenches/ under Floor/ under Road/ fixing on pole/ above floor, complete all as specified and as directed by Engineer-in-charge. NOTE : Earthworks, Sand Cushioning, Bricks, GI Pipe, etc. will be measured and paid under appropriate Items.
Supply & Laying Sub-Class B Bricks, well burnt, laid breadth wise along the length of cable laid in trenches over sand cushion laid for UG cable protection, complete all as specified and as directed by Engineer-in-charge.
S&F in-repair of Galvanised Iron Pipe 32mm bore (dia) ‘light grade’ for protection of UG Cable, laid under Floors or Road Crossing, fixing to Pole with and including Mild Steel Clamps, Nuts, Bolts, etc., complete all as specified and as directed by Engineer-in-charge.
M/S S.S. Construction
M/S PARKASH ENTERPRISES
Shiva Builders
MS Gautam Construction and CO
OM CONSTRUCTIONS
M/S NARAYAN ENTERPRISE
M/s SHARMA BUILDERS & ENGINEERS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .