Executive Engineer MID Akhnoor/Nowshera
office of executive engineer MID Akhnoor/Nowshera
Providing and Fitting/installation of New Fully Automatic Electric Control panel/FASD Starter-Cum-Protection panel complete with overcurrent undercurrent over under voltage single phase prevention with one number incoming and two outgoing panel
2021_IFC_144495_1
70/MID/AN
Open Tender
Machineries/ Mechanical Engg Items
Item Wise
45 days
Rajal
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Yes
Convener, purchase committee, Directorate of ISM
Exempted
office of executive engineer MID Akhnoor/Nowshera
18 May 2022
20 Oct 2021
1 Nov 2021
20 Oct 2021
30 Oct 2021
21 Oct 2021
23 Oct 2021
Providing and Fitting/installation of New Fully Automatic Electric Control panel/FASD Starter-Cum-Protection panel complete with over current, undercurrent, over & under voltage, single phase prevention with one number incoming and two outgoing panel circuits and all digital measurement devices with allied works for 0.7 cusec discharge × 90 mtrs head pump with 50 HP motor at LIS Langer. Description of panel Designing, fabrication, installation, testing and commissioning of LT control panel 415 volts, AC-3 Phase, 50 Hz. for pumping unit no. 01 & 02 at L.I.S Langer .The panel shall be dust and vermin proof fabricated out of 16 SWG CR Sheet supported on M.S. angle of suitable size and having provision for fixing it on the ground with the help of foundation bolts. The panel should be sturdy enough for vibration free operation and should be equipped with suitable locking /sealing arrangements. The structure should be provided suitable entry and exit holes for incoming and outgoing cables. The panel should be given two coats of anti rust primer and two coats of steel grey enamel paint. The panel should have equipped with following components / features: M.C.C.B.The panel should be fitted with an M.C.C.B. of 200 Ampere capacity, 1 No. volt meter, 1No ammeter along with a set of CTs, 1 No. V.S.S., 1 No. A.S. switch and a set of RYB indicators at incoming side including the bus bars . Outgoing no. 1 : The panel should be fitted with a 50 HP automatic star delta starter comprises of 3 Nos. air break contactors compatible with 50HP induction motor (2 Nos. 95 A for main and delta supply, 1 No. air break contactor 70 A for star operation), 1 No. timer for change over the supply of motor from star to delta, 2 Nos. push buttons for start and stop operation of motor, 1 No. indicator .1 No. MCB for the protection of internal control wiring, a neat and clean internal control wiring should be made with flexible copper cables/ bus bars to complete the star delta circuit of out going supply for pumping unit no. 1 Outgoing no. 2: The panel should be fitted with a 50 HP automatic star delta starter comprises of 3 Nos. air break contactors compatible with 50HP induction motor (2 Nos. 95 A for main and delta supply, 1 No. air break contactor 70 A for star operation), 1 No. timer for change over the supply of motor from star to delta, 2 Nos. push buttons for start and stop operation of motor, 1 No. indicator .1 No. MCB for the protection of internal control wiring, a neat and clean internal control wiring should be made with flexible copper cables/ bus bars to complete the star delta circuit of out going supply for pumping unit no. 2. Protections device / fault analyzer : A protection device / fault analyzer shall be fitted with the panel with capability to protect each motor by isolating the power supply of motor by de-energizing the starter/panel from following electro-mechanical faults which may otherwise damage the motor windings : A. Voltage related fault: Single phasing, under voltage, over voltage, unbalance voltage. B. Current related fault:Under Current, Over current / load, dry running, unbalance current / load, earth leakage, short circuiting. C. Display line current of RYB Phase and also line voltage of RY ,YB and BR phase. Bimetal overload relay: Bimetal over load relay of suitable range should be fitted with in the each starter as an extra protection to protect the motors in case of failure of fault analyzer . Providing/ fitting of copper cable 40 mtr. of size 16 sq. mm from starter no. 01 & 02 to motor no. 1 & 2. Complete job includes cost of providing/ fitting ,transportation charges ,hire charges of tool and tackles charges, hire charges of skilled and unskilled labour, and all kinds of taxes thereof. complete job. Make of MCCB – Any reputed make as per ISO standards.. Make of contactor – Any reputed make as per ISO standards... Make of cable – Any reputed make as per ISO standards.. . .
PERFECT ELECTRICAL WORKS
M/s RK Elect. Mech. Engg and fabrication works
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .