Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.1 LAccepted-AOC FLAT NO 20 AMBEDKAR ROAD DEHU ROAD PUNE 412101 D 101 CESC INDEX NO D 101 HQ CESC PUNE | NA | NA | 412101 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹17.2 L+₹1,762.04 (0.10%)Rejected-Finance 6 SAI KRUPA SONAWANE PARK BEHIND TILAK NAGAR BUS STOP OZAR MIG NASHIK 422206 | NASHIK | NASHIK | MAHARASHTRA | 422206 | L2 | Rejected-Finance BEING NOT L1 | |
| 3 | L3₹22.5 L+₹5.3 L (31.0%)Rejected-Finance | L3 | Rejected-Finance BEING NOT L1 |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
28 Jul 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE AF OJHAR
GE AF OJHAR
REPAIR TO PATH HARDSTANDING AND OTHER MISC WORK IN DOMESTIC TECHNICAL AREA AND RAKSHANAGAR AT AF STATION OJHAR
2022_MES_534687_1
8894/E8
Open Tender
Civil Works
Item Rate
180 days
OJHAR
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE AF OJHAR
₹40,000
Yes
10 Aug 2022
30 Jun 2022
30 Jul 2022
1 Jul 2022
28 Jul 2022
14 Jul 2022
60 days
Amount
Demolition cement concrete of any description and in any position not otherwise specifically provided for inlcluding PCC of existing roof, PCC tiles with screed bed and removing the demolished material outside MoD land at own arrangments of Contractor.
M & L for 75mm thick Cement Concrete type B0 (1:4:8) using 40 mm graded stone aggregate as in sub base of floor
Supply and spreading sand under floors or in foundation including watering and consolidation
M & L for Machine pressed precast conctete interlocking paver block with grey cement and pigment any shape ,size and colour confirming to IS 15658-2006of 60 mm thickness, M-40 Grade, Make : Hindustan / Universal all as specified and directed Engr-in-Charge.
S&F Chequered cement concrete tiles 300MM X 300MM x 25mm thick, set, jointed and pointed in white cement and pigment cement slurry in floors with screed bed CM 1:6, 15mm thick complete.Make : Hindustan / Universal
M&L for plain cement concrete 1:2:4 type B-1 using 20mm graded crushed aggregate as PCC kerb and coping and similar items including form work and finished even and fair complete all as specified and directed by Engineer-in-charge.
Demolition of brickwork built in cement mortar including all quoins, arches, pillars, but excluding pre-cast concrete articles, Complete all as specified and directed by Engineer-in-charge.
M&L Brick work with subclass `B' bricks, straight or curved on plan exc 6m mean radius, built in CM 1 : 4 including pointing flush the external face of the brick work as the work proceeds all as specified and directed by Engr-in-Charge
M&L for 15 mm thick cement plaster in CM 1:4 on brick surface finished even and smooth without using extra cement Complete all as specified and directed by Engineer-in-charge.
Labour only for taking out existing sand mixed with wooden saw dust, from the embankment of firing range , screenig through net then mixing the saw dust in proportion of 1:1, then again forming embankment at original place of firing range by raising height including ramming/rolling and finished to required size & shape etc not exceeding 1.5m high form the base Complete all as specified and as directed by Engineer-In-Charge. Note:- The additional saw dust and sand shall be added to the taken down materials after screening to maintain proportion 1:1 (Sand : Saw dust), which are actually brought at site by Contractor, measured by deptt and paid separetly under below item No 14 & 15)
All as per item No-10 above but height exceeding 1.5m hight and upto 3m complete all as specified and as directed by Engineer-In-Charge
All as per item No-10 above but height exceeding 3m hight and upto 4.5m complete all as specified and as directed by Engineer-In-Charge
All as per item No-10 above but height exceeding 4.50m hight and upto 6.00m complete all as specified and as directed by Engineer-In-Charge
Supply only screened river fine sand free from clay, silt and other foreign materials as per sample approved complete all as specified and as directed by Engineer-In-Charge.
Supply only wooden saw dust Complete all as specified and as directed by Engineer-In-Charge.
Dismantling wrought iron or mild steel work of any description not otherwise provided for
S&F Hand rails, half round or other mild steel section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts; posts and struts in fencing including cutting tops to shapeas directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165
Dismantling Asbestos cement /FRP sheet/GI sheet(corrugated ted, semi corrugated, etc.) sheets in roof coverings up to height 25M and taking care of earthing strip and refixing all as specified and directed by Engr in Charge
M & L for pre-painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm TCT thick of any colour approved by GE having tensile strength of 550Mpa as in roof covering / cladding to wall/ Corner complete all as specified and as directed by Engineer-In-Charge.
Refixing of CGI corrugated sheets/Ridge/Sides sheets/Gutters with Drill machine and fixed with self taping screws. The contractor shall arrange for climbing upto 16 mtr ht and followed the all safety guidelines as per labour law.
S&F Zinc coated Hexagonal Self taping screw length 65mm with washer fixed to existing hanger roof/wall cladding sheets complete.
M&L for sealing the holes/gaps on existing CGI/ Galvalume sheeting roof/Wall of hangers with 100mm x 100mm Self Adhesive tape over that 1 coat of Techothane - PU White 1mm thick complete make : Tikki tar, Choksey , STP or Asian and make leakage proof including cleaning by removal of existing rust etc.all as per manufacturers instruction and directed by Engr-in-Charge Note : (i) The work shall be carried out in hangers of 16mtr height. (ii) Existing sheets in hanger is galvalume sheet which contains holes and other misc works in different locations of three hangers. (iii) Work is also deemed to be carried out during rain to emergeny and imidiate requirement. (iv) Being very sensetive location the labourers shall have to move on hanger roofs. contractor will follow every safety norms of labour during the exectuion to avoid any mishap. If any mishaps happen due non fellow of safety norms/ accessories / equipments required Contractor shall be held fully responisible.& rates of safety norms are deemed to be included in the items mentioned above nothing extra shll be paid.
M&L for sealing the holes/gaps on existing CGI/ Galvalume sheeting roof/Wall of hangers with 100mm wide Self Adhesive tape over that 1 coat of Techothane - PU White 1mm thick complete make : Tikki tar, Choksey , STP or Asian and make leakage proof including cleaning by removal of existing rust etc.all as per manufacturers instruction and directed by Engr-in-Charge Note : (i) The work shall be carried out in hangers of 16mtr height. (ii) Existing sheets in hanger is galvalume sheet which contains holes and other misc works in different locations of three hangers. (iii) Work is also deemed to be carried out during rain to emergeny and imidiate requirement. (iv) Being very sensetive location the labourers shall have to move on hanger roofs. contractor will follow every safety norms of labour during the exectuion to avoid any mishap. If any mishaps happen due non fellow of safety norms/ accessories / equipments required Contractor shall be held fully responisible.& rates of safety norms are deemed to be included in the items mentioned above nothing extra shll be paid.
Haking out old broken glass (any thickness, size, quality or description) from steel frame surrounded, glazing with putty.
S&F Rough cast wired glass 6.4mm thick size exc 0.75 Sqm but n exc 1.5 sqm and glazing fixed with provision of MS 'U' clip with nut & bolt, make leakege proof with bitumen based gaskets around the glass at joint of MS frame and fixed oil putty of strength to with stand with the extreme weather norms in external exposed site all as specified and directed by Engr-in-Charge. Note : (i) Contractor shall made own arrengment for climbing and working on hangers not exceeding 16 mtr ht. (ii) The Contractor shall be laible to executed the work in rainy season, if any lackage occuried without any objection. All safety measures are followed by the Contractor as per safety guidlines. (iii) As per Engr-in-Charge's direction the Contractor shall rectify the given leakage complaint, without any failed within 48 hrs. in case, fail to attend the complaint. the recovery amount will be double on the quoted rate of item by the contractor for each complaint.
M&L for 2 mm thick polycarbonate sheet with both side including top & bottom aluminium to match with the profile of existing roof sheet and EPDM rubber gasket fixed with self tapping screws in roof/wall up to any height ,both side UV Proctected . complete all as specified and as directed by engg. in charge. Make : Duratuff/lexon Any extra accesseries rtequired for fixing of Polycarbonate between Galvelume sheets roofing deemed to be included rates. Note : (i) Contractor shall made own arrengment for climbing and working on hangers not exceeding 16 mtr ht. (ii) The Contractor shall be laible to execute the work in rainy season without any objection, if any leakage occuried . All safety measures are followed by the Contractor as per safety guidlines.
M&L for welding in repairs exc. 2.5cm but n exc. 5cm in length, thickness of metal to welded exc 6mm but n exc 9mm compete all as specified as directed by Engineer -in -charge
Dismantling and breaking up Rainwater pipe PVC Pipes of any dia including all fittings any size all as specified & as directed by Engr-in-Charge.
S&F PVC (SWR) pipe 160mm bore of pipe, single socket in any length with rubber ring joint, fixed to walls /Floor. all as specified and directed by Engr-in-Charge.
Refixing PVC (SWR) pipe 160mm bore pipe to wall /floor all as specified and directed by Engr-in-Charge.
S&F MS Bands, straps, supports to gutter or stays for rainwater, clamps; hold fasts and similar small articles conforming to Fe-290 Gde-E-165 all as specified and directed by Engr-in-Charge.
S&F PVC (SWR) 160mm bore door bend specified & as directed by Engr-in-Charge.
S&F PVC (SWR) 160mm bore shoe bend specified & as directed by Engr-in-Charge.
S&F PVC (SWR) 160mm bore Socket specified & as directed by Engr-in-Charge.
M&L for PCC 1:2:4 type B1 (20mm graded aggregate) as in coping/Hunching/splash stone item all as directed by Engr-in-Charge
M&L for Preparation of new or previously untreated surfaces of steel or iron surfaces exceeding 10cm width or girth and applying two coats of aluminium paint over one coat of red oxide primer.Complete all as specified and as directed by Engineer-In-Charge.
Repairs to aluminium door shutter of any description and size including taking down from frames for realignment and tightening including adjusting the shutter removal and refixing hydraulic or floor door spring , and hinge , refixing shutter in same opening with all necessary repairs /refixing ,including replacement of damaged jointing cleats ,glazing clips , rubber packing ,aluminium beading , screws etc also including provision of 6 mm dia through bolt with nut on both side for top and bottom rail. complete all as specified and as directed by Engineer-in-charge. Note : (i) Superviser will report to AGE B/R Ojhar office for collecting aluminium door repair complaint when required and completed the complaint within 24 hrs in AOR of 11 BRD MES bldgs. (ii) In case, fail to attend the complaint within 24 hrs, the recovery amount will be double on the quoted rate of item by the contractor for each complaint.
Repairs to aluminium window shutter of any description and size including taking down from frames for realignment and tightening including adjusting the shutter removal and refixing shutter in same opening with all necessary repairs /refixing ,including replacement of damaged jointing cleats ,glazing clips , rubber packing ,aluminium beading , screws etc complete all as specified and as directed by Engineer-in-charge. Note : (i) Superviser will report to AGE B/R Ojhar office for collecting aluminium door repair complaint when required and completed the complaint within 24 hrs in AOR of 11 BRD MES bldgs. (ii) In case, fail to attend the complaint within 24 hrs, the recovery amount will be double on the quoted rate of item by the contractor for each complaint.
General Notes : Note : (i) The Scope of work for all the items catered above is in hangers, four storey building of 16 mtr ht. Contractor shall make his own arrengment for working on hangers for Ladders/ Scafolding / Swing/ropes and other equipment / accesseries. (ii) The Contractor shall be laible to executed the work in rainy season, if any leakage occured during rain contractor shall deemed to be rectifiy the defect immediately. All safety measures are followed by the Contractor as per safety guidlines. (iii) Only skilled labour shall only be provided being sensetive and expertise work. (iv) Nothing extra shall be paid on the terms mentioned above & rates are deemed to be included of above norms.
M/s M R MAHANA
GUND PARAG JAGANNATH
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .