Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.8 LAccepted-Finance COOCH BEHAR WEST BENGAL | COOCH BEHAR | COOCH BEHAR | WEST BENGAL | L1 | Accepted-Finance L1 | |
| 2 | L2₹14.0 L+₹14,994 (1.08%)Rejected-Finance COOCH BEHAR | COOCH BEHAR | COOCH BEHAR | WEST BENGAL | L2 | Rejected-Finance L2 | |
| 3 | L3₹14.1 L+₹23,458 (1.70%)Rejected-Finance COOCH BEHAR 736101 | COOCH BEHAR | COOCH BEHAR | WEST BENGAL | 736101 | L3 | Rejected-Finance L3 |
Tender Value
Refer Docs
EMD Value
₹28,000
Closing Date
6 Jan 2021, 1:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
EE, CED, COB, SUNITY ROAD
Executive Engineer PWD Cooch Behar Electrical Division Cooch Behar
WBPWD/EE/CED/e-NIQ12/20-21
2020_WBPWD_308226_1
WBPWD/ee/CED/e-NIQ-12/2020-21
Open Tender
ELECTRICAL WORKS ORG
Item Rate
30 days
MATHABHANGA
Please refer tender documents
5 documents required · 5 mandatory
₹28,000
Yes
22 Jan 2021
9 Dec 2020
8 Jan 2021
9 Dec 2020
6 Jan 2021
9 Dec 2020
120 days
Amount
Distn. wiring in 3X22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire in 19 mm bore, 3 mm thick polythen pipe with all accessories embedded in wall to light/fan/call bell points as per GS with following average run 10 Mtr. E24/1
Distribution wiring in 1.1 KV grade 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit 'FR' (Precision make), with 1.1 KV grade 1 x 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire as ECC, to 6A 3 pin plug socket & switch (Brand approved by EIC) on 4 Module GI switch board with 3/4 Module top cover plate on wall incl. necy. connection making earthing attachment, painting and mending good damages to building works. On Board
Cutting Channel of size (40 mm x 40 mm) on masonry wall by Electric operated cutting machine incl. supplying & fixing heavy gauge 19 mm, 3 mm thick Polythene pipe by means of anchoring chemical (Hilti/Sika) and GI 'U' hooks of 8 SWG incl. supplying and drawing 18 SWG GI wire as Fish wire and mending good damages to original finish by using own tools and tackles. [6(a)/E-3]
Supply & Fixing 32 mm PVC Rigid conduit FR(Precision Make) on wall ceiling with saddle and Accessorise as Requred and Mending Good Damage to Building works.
Supply & Fixing 20 mm PVC Rigid conduit FR(Precision Make) on wall ceiling with saddle and Accessorise as Requred and Mending Good Damage to Building works.
Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire of the following sizes in the prelaid polythene pipe as per GS.
3 x (1.5 sqmm) [1(b) / E- 9 ]
2x(2.5 sqmm)+1x(1.5 sqmm) [ 1(s) / E-9 ]
2x(4 sqmm)+1x (2.5 sqmm) [ 1(v) / E- 9 ]
2x (6 sqmm) + 1x (4 sqmm) [ 1 (y) / E- 9 ]
4x (16 sqmm) + 2x (10 sqmm) [ 1 (y) / E- 9 ]
Finishing of the PVC insulated wire ends by socketting with pin/ring type copper sockets and insulated tapes etc., includingsupplying sockets, tapes.
Supplying & Fixing sheet metal inspection box (16 SWG) of the following sizes(in mm ) flushed in wal including perpase cover l as per GS
Two way Circular Box & cover
Supplying and fixing double door Vertical TPN MCB Distribution board for MCCB incomer with IP-42/43 protection, on angle iron frame on wall as per GS ( Make - Legrand / L&T )
8Way ( Up to 160A ) [15 / D- 11 ]
Supplying and fixing 415 V Four Pole MCCB of Breaking capacity 25kA in existing Vertical DBs including necessary connection as per GS [ Make - Legrand] .
160A FP [Make - Legrand Type DPX3 Cat No: 4202 19 ] [ 10/ D- 8 ]
Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall as per GS. 2+12 Way[ Legrand ] ( Incomming via UPS Line for uninterepted power supply to for Light,Fan & computer point). [ 13 / D- 9 ]
Supplying and fixing double door Horizontal TPN MCB Distribution board with IP-42/43 protection, concealed in wall as per GS.( Make - Legrand )
Supplying and fixing 240/415 V MCB Isolator on din rail of existing DBs and necessary connection as perGS [Make-Legrand ]
Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connectionas per GS [ Make -Legrand ]
Supply & Fixing 240 V, 16 A, 3 pin Modular type plug socket (Brand approved by EIC) with 16A Modular type switch, without plug top on 6 Module GI Modular type switch board with top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. as per G.S
Supply & Fixing 240 V, 3 nos. 16 A, 3 pin Modular type plug socket with 3 nos. 16A Modular type switch (Brand approved by EIC), 20A Modular switch type SP MCB (C-Curve) and Indicator without plug top on 2 row 12 Module GI Modular type switch board with 2 row 12 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. as per G.S
Supply & Fixing 240 V, 2 nos. 5 A, 3 pin Modular type plug socket with 2 nos. 5 A Modular type switch (Brand approved by EIC), Indicator without plug top on GI Modular type switch board with top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc, with connector as per G.S.
Supplying & Fixing Industrial Plug & Socket board with 240 V, 20A, SPN & Earth Metal Industrial Plug socket & 20A Industrial top as per GS.
Fixing only florescent light fitting suspended 25 cm bellow the ceiling with 2 No. 20 mm dia EI conduit (14 SWG) supports etc as per G.S [ 15 / C-2 ]
Extra for suspension exceeding 25 cm with S&F additional 2 no. 20 mm dia EI conduit as per GS [16/C-2 ]
Supply of 4 Ft. single/twin LED light fitting for indoor application,complete with all accessories & LED tubes having following Model / Cat No.( Make -Philips)
a. TMC 501 P 1xT-LED 22W P3241
S&F 2x2 Squre 36 watt Smart Glow LED Luminaure for greed ceiling Make Philips Model No:fitting madel- SM 365B LED 33S-6500 PUS OD WH PIR MAKE - PHILIPS
S& F pendent Holder with 9 Watt LED Bulb.Make Philips
Supply & Fixing Step type fan regulator (Step type)(Brand approved by EIC) on existing sheet metal switch board as per GS [ 18 (a) / E-6 ]
Fixing only ceiling fan complete with blades, canopy, fork, rubber bush etc as per GS [ 21 (a) / C-3 ]
Fixing only exhaust fan after making holes in wall as per GS
Supply & Fixing GI sheet (20SWG) metal Cowl with MS flat iron frame & GI wire mesh on wall as per GS
Fixing only cabin fan on wall/ceiling by S&F rag bolts, nuts & washers as per GS [29/ C-4]
S& fixing R.C Fan Clamp as per G.S.
Supply of ceiling fans having antidust property complete with all accessories having the following Model / Cat No. ( Make -Crompton Greaves/Orient Electric )
a. 1200 mm Sweep ( Aura Metallic (Make Crompton Greaves)/Summer Cool(Make Orient Model Summer Cool Brown Clour) )
Supply of Exhaust fans complete with all accessories having the following Model / Cat No. ( Make -EPC )
9" ( 230mm ) Speed 1370 RPM
Supply of bracket fan (18" Dia orient wall tornado Make Orient).
Supplying & Fixing 240 V AC/DC superior type Ding-Dong Call Bell (Anchor) as per GS [ 20( a )/D-13 ]
S & F Railway type water guard protection G I loop box & both side having 2 no.s nut bolts for earth protection & having a locking arrangement and inside of box din rail fixing 1 no. for fixing of FP MCB Isolator
S & F 32 A FP Isolator inside of loop box
S & F (2+4) 4 way double door DB box with FP 32 Amp Isolator 1 no ( Make Legrand ) as per G.S. for indoor control switch of Ac
S&F of UV Base water purifier ,Water flow-200 ltrs/hours single faucet with LED display alonge with end point purification Technology.(Make approved by PWD Apyron/Forbase pro/Eureka Forbes)
Supply & delivery 7.5TR capacity concealed type Split Air Conditioner of rated cooling capacity of 90000 BTU/hr. with 3Nos. twin rotary compressor, 3nos. IDU of rated power supply-230V-1ph-50Hz. , 1no. ODU of rated power supply-400V-3ph-50Hz. Air-flow/per IDU:- 1000CFM. ( Make: Hitachi/Daikin/Mitshubishi) for Posco Court
Supply & delivery 5.0TR capacity concealed type Split Air Conditioner of rated cooling capacity of 60000 BTU/hr. with 2Nos. twin rotary compressor, 2nos. IDU of rated power supply-230V-1ph-50Hz. , 1no. ODU of rated power supply-400V-3ph-50Hz. Air-flow/per IDU:- 1000CFM. ( Make: Hitachi/Daikin/Mitshubishi) for Posco Victim room
Erection & Commissioning Charges for 7.5 TR Air Conditioner
Erection & Commissioning Charges for 5.0 TR Air Conditioner
Copper Refrigeration pipe line for Liquid Line (3/8" OD with 0.6 mm thick) supports & brackets for 7.5 Tr & 5.0 Tr Concealed split Ac machine(Make:Ryoku/Nippon)
Copper Refrigeration pipe line for Suction Line (5/8" OD with 0.7mm thick)) supports & brackets for 7.5 Tr, & 5.0 TR Concealed split Ac machine(Make:Ryoku/Nippon)
Copper Refrigeration pipe line for Liquid Line (1/4" OD with 0.7mm thick)) supports & brackets for 5.0 TR Concealed split Ac machine(Make:Ryoku/Nippon)
Supply & Fixing Pipe Insulation in Liquid line with 9mm Nitrile rubber tube for 7.5 Tr & 5.0 TR Concealed split Ac machine(Make:Accoroflex/Suprime)
Supply & Fixing Pipe Insulation in suction line with 9mm nitrile rubber tube for 7.5 Tr & 5.0 TR Concealed split Ac machine(Make:Accoroflex/Suprime)
Supply & Fixing Pipe Insulation in Liquid line with 9mm nitrile rubber tube for 5.0 TR Concealed split Ac machine(Make:Accoroflex/Suprime)
Control Cabling from Condensing Unit to Control Panel 4 Core 2.5sq. mm. Communication Cable for 7.5 TR Concealed Split AC Machine.(Make:Finolex/KEI/Polycab)
Control Cabling from Condensing Unit to Control Panel 3 Core 2.5sq. mm. Communication Cable for 7.5.0 Tr & 5Tr Concealed Split AC Machine.(Make:Finolex/KEI/Polycab)
Supply and fixing flexible double canvass connection for concealed split air-conditioners.
Supply and fixing of Al powder coated continuous Grill(Make: Primear/Airkolkata)
Supply & laying PVC Drain Pipe 25mm dia(Make:Suprime/Oriplast)
Supply & laying PVC Drain Pipe 32mm dia(Make:Suprime/Oriplast)
Charges for Scaffolding arrangement including lifting for outdoor & indoor units
Charges for drop ceiling to cover the indoor unit made of Everest E Board or HILUX (calcium cilicate board) or Gypsum Board with painting so as to match.
Charges for Trap Door made of Aluminium Channel& Plywood for IDU Maintenance
a) Supplying, fabrication & fixing M.S u-channel of 6 mm thick of size (75 mm x 40 mm x 40 mm) for making platform for installation of outdoor unit of 7.5Tr & 5.0 TR & 3.0 TR Concealed split AC incl. drilling 2 nos holes in each channel including cutting holes into the wall & grouting the same with cement concrete (1:1 ½ :3) etc. fabricated with horizontal angle of 25 mm x 25 mm x 6 mm including supporting angle 50 mm x50mm x 6 mm in each platform in outer edge for transmitting the load centrally through 2Nos. (50 mm x 50 mm x 6 mm) Angle inserted into the exiting wall.
Supply & delivery of cubical type L.T. Distribution panel board of size requird , wall mounted compartmentalized with maple arrangement having rigid & self supporting structure fabricated from 2 mm thick CRCA sheet steel with M/S angle frame. The panel board consisting of the following switches. A) Incoming Arrangement.i)switch disconnect or fuse ( panel mounting cubical type) conform to IS 13947 in open execution three pole & Neutral AC 23A, 50HZ, 415V 250Amp with 3 nos 250 Amp DIN type HBC fuse lin L&T make . II)S & F 415 Volt,250 Amp. euro load four pole on load Change over switch (qubical type. ) L&T Make. 1 no. B)Bus Section:500 V 600A. electrolyte grade tinned copper bus bar with vertical section of size 40 x 5 mm for Phase RYB, & 40x5 mm for neutral bars & 40x 5 mm Al. Bar for earth. A bus bar shall be fixed with FRP chair & the entire bars are insulated with PVC heat Sinkable sleeve of suitable size & color as per direction of E.I.C C) Outgoing arrangement: a) switch disconnect or fuse (panel mounting cubical type) conform to IS : 13947 in pen execution three pole & Neutral AC 23A,50Hz, 415 Volt 160 Amp with 3 nos 160 Amp DIN type HBC fuse link , L&T make -------3 Nos. b) switch disconnect or fuse (panel mounting cubical type) conform to IS : 13947 in pen execution three pole & Neutral AC 23A, 0HZ, 415 Volt 63 Amp with 3 nos 63 Amp DIN type HBC fuse link , L&T make .------1 Nos. c) switch disconnect or fuse (panel mounting cubical type) conform to IS : 13947 in pen execution three pole & Neutral AC 23A, 0HZ, 415 Volt 32 Amp with 3 nos 32 Amp DIN type HBC fuse link , L&T make ------1 Nos.
Supply of 4/3.5 Core XLPE Insulated & Sheathed Armoured Aluminium Conductor cables for Working Voltage up to 1100 Volts of following sizes [ Make Nicco/ MESCAB/Gloster/KEI/Polycab ]
4 Core 120 Sq. mm
4 Core 95 Sq. mm
4 core 70 Sq. mm
Laying of cable after cutting floor/pavement/wall as per GS for the following sizes.
Above 35 sqmm to 95 sqmm [ 5(ii)/ F- 3 ]
Above 95 sqmm [ 5(ii)/ F- 3 ]
GANESH ELECTRICAL COMPANY
THE ELECTRIC EMPORIUM
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .