Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹30.8 LAccepted-AOC B 235 MULLA COLONY B SECTOR KAROND BERASIA ROAD BHOPAL | BHOPAL | MADHYA PRADESH | 462001 | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹31.6 L+₹57,785.30 (1.86%)Rejected-Finance 43 VIMAL ENCLAVE CHAMRAULI MODE SHAMSHABAD ROAD AGRA UP 282001 | AGRA | AGRA | UTTAR PRADESH | 282001 | L2 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 3 | L3₹31.7 L+₹62,300.30 (2.01%)Rejected-Finance LIG 10 VIVEK NAGAR NAVIBAGH BHOPAL MADHYA PRADESH 462038 | BHOPAL | MADHYA PRADESH | 462038 | L3 | Rejected-Finance OTHER THAN LOWEST BIDDER |
| Sl No | Description | Qty | Unit | SAMEER ELECTRICAL SUPPLIER L1 | S S TRADERS L2 | PRAGATI ELECTRICALS AND ELECTRONICS L3 |
|---|---|---|---|---|---|---|
| 1.00Note :(i) Please refer Sch A/ BOQ Notes before quoting the tender for all phases/ items mentioned below. (ii) Amount of Schedule of credit shall be deducted offline | ||||||
| 1.10 | Taking out old unserviceable cable of any type and size from trenches complete all as specified and directed. | 1,500 | Cum | 10 ₹15,000 Lowest | 10 ₹15,000 Lowest | 10 ₹15,000 Lowest |
| 2.00 | Excavating in trenches, not exceeding 1.5m wide and not exceeding 1.5m in depth for pole foundation, cable trench, etc and getting out in hard/dense soil complete all as specified and directed. | 265.5 | Cum | 175 ₹46,462.5 Lowest | 220 ₹58,410 | 180 ₹47,790 |
| 3.00 | Excavating in trenches, not exceeding 1.5m wide and not exceeding 1.5m in depth for pole foundation, cable trench, etc and getting out in soft disintegrated rock complete all as specified and directed. | 9 | Cum | 155 ₹1,395 Lowest | 170 ₹1,530 | 160 ₹1,440 |
| 4.00 | Excavating in trenches, not exceeding 1.5m wide and exceeding 1.5m but not exceeding 3.0m in depth for pole foundation, cable trench, etc and getting out in soft disintegrated rock complete all as specified and directed. | 0.27 | Cum | 180 ₹48.6 Lowest | 280 ₹75.6 | 200 ₹54 |
| 5.00 | M&L for making good the disturbed surface by filling PCC 1:2:4 type B-1 (using 40 mm graded course aggregate) to match with existing surfaces complete all as specified and directed. | 1.5 | Cum | 4,200 ₹6,300 | 200 ₹300 Lowest | 4,500 ₹6,750 |
| 6.00 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm each complete all as specified and directed. | 47.62 | Cum | 95 ₹4,523.9 Lowest | 120 ₹5,714.4 | 100 ₹4,762 |
| 7.00 | Removing excavated materials to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed. | 170.65 | Cum | 78 ₹13,310.7 Lowest | 100 ₹17,065 | 80 ₹13,652 |
| 8.00 | M&L for cement concrete 1:4:8 type D-2 (using 40mm graded stone aggregate) as in foundations, filling and mass concrete complete all as specified and directed. | 0.92 | Cum | 4,000 ₹3,680 Lowest | 4,200 ₹3,864 | 4,000 ₹3,680 Lowest |
| 9.00 | M&L for cement concrete 1:3:6 type C-2 (using 40mm graded stone aggregate) as in mass concrete including fdn bed to stays/ poles and similar work including necessary form work complete all as specified and directed. | 9.18 | Cum | 3,800 ₹34,884 Lowest | 4,500 ₹41,310 | 4,000 ₹36,720 |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
30 Oct 2025, 6:00 pmClosed
GE BHOPAL
GE BHOPALl BAIRAGARH BHOPAL
REPAIR REPLACEMENT OF LT NETWORK SYSTEM INCLUDING REPAIR OF STREET LIGHTS SECURITY LIGHTS SOLAR LIGHTS AND PERIMETER LIGHTS AT SI LINES
2025_MES_734684_1
8444/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
BHOPAL
Please refer tender document
7 documents required · 7 mandatory
₹500
GE BHOPAL
₹80,000
Yes
18 Dec 2025
11 Oct 2025
1 Nov 2025
11 Oct 2025
30 Oct 2025
25 Oct 2025
Amount
Note :(i) Please refer Sch A/ BOQ Notes before quoting the tender for all phases/ items mentioned below. (ii) Amount of Schedule of credit shall be deducted offline
Taking out old unserviceable cable of any type and size from trenches complete all as specified and directed.
Excavating in trenches, not exceeding 1.5m wide and not exceeding 1.5m in depth for pole foundation, cable trench, etc and getting out in hard/dense soil complete all as specified and directed.
Excavating in trenches, not exceeding 1.5m wide and not exceeding 1.5m in depth for pole foundation, cable trench, etc and getting out in soft disintegrated rock complete all as specified and directed.
Excavating in trenches, not exceeding 1.5m wide and exceeding 1.5m but not exceeding 3.0m in depth for pole foundation, cable trench, etc and getting out in soft disintegrated rock complete all as specified and directed.
M&L for making good the disturbed surface by filling PCC 1:2:4 type B-1 (using 40 mm graded course aggregate) to match with existing surfaces complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm each complete all as specified and directed.
Removing excavated materials to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed.
M&L for cement concrete 1:4:8 type D-2 (using 40mm graded stone aggregate) as in foundations, filling and mass concrete complete all as specified and directed.
M&L for cement concrete 1:3:6 type C-2 (using 40mm graded stone aggregate) as in mass concrete including fdn bed to stays/ poles and similar work including necessary form work complete all as specified and directed.
M&L for cement concrete 1:2:4 type B-1 (using 20mm graded stone aggregate) as in copings to poles & the like, etc; including slightly rounded and the like including necessary form work complete all as specified and directed.
M&L for sand filling with clean dry fine sand unwashed including gently punning around cables in trenches for cable protection (8 cm below cable & 15 cm above cable) complete all as specified and directed. Note:- Only compacted/punned thickness shall be measured and paid under relevant item.
Supply and laying cable protection cover, class LV, Type I, flat, size 250 x 150 x 40 mm, laid flat and dry in trenches over the cable perpendicular to the direction of cable complete all as specified and directed.
Supply, laying, connecting and testing LT XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, heavy duty cable, 1100 volts grade, aluminium conductor of size 10 Sqmm nominal cross section x 2 core and laid in trenches, passing through pipes/ducts, fixed on walls with shadels, etc including taking out old unserveciable cable, any type complete all as specified and directed.
All as per item No. 13 here-in-before but size 10 Sqmm X 4 core complete.
All as per item No. 13 here-in-before but size 16 Sqmm X 4 core complete.
All as per item No. 13 here-in-before but size 25 Sqmm X 4 core complete.
All as per item No. 13 here-in-before but size 50 Sqmm X 3.5 core complete.
All as per item No. 13 here-in-before but size 120 Sqmm X 3.5 core complete.
Dismantling cross arms, bracings, supports, clamps and back plates from existing poles (other than dismantled poles) and pole structures complete all as specified and directed.
S&F of mild steel structural sections as in cross arms, bracing, supports, clamps and back plate with & including new nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size with and including applying two coats of aluminium paint over a coat of red oxide primer complete all as specified and directed.
S&F in repairs pin type, polymer insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut suitable for working pressure 1100 volts grade supply complete all as specified and directed.
S&F in repairs polymer disc insulator ball & socket type with tension clamp and accessories suitable for conductor single disc assy of working pressure 1100 volts complete all as specified and directed.
S&F in repairs aluminium conductor steel reinforced including straining properly on insulators and binding with aluminium binding wire complete all as specified and directed. Type of new conductors:- Weasel/ Rabbit/ Mink. Note : Measurements for the purpose of payments shall be made by measuring horizontal distance between centers of two adjacent poles and adding 3% extra for sag, joints, jumpers etc.
M&L for tightening and re-stringing of existing ACSR over head conductor of any size/type on LT over head line with the help of rope/line wise and tighting the conductor to permissiable sag limit with and including new aluminium tape/aluminium wire complete all as specified and as directed. Note: (i) Old conductor shall be reused where required for repairing broken length of conductor as directed. (ii) Five lines together will be measured as one span from pole to pole.
S&F in replacement cable saperator heavy duty made of plastic with PVC clamps heavy duty, two phase separator complete all as specified and directed.
S&F in replacement cable saperator heavy duty made of plastic with PVC clamps heavy duty, three phase separator complete all as specified and directed.
S&F in replacement of cradles, hexagonal/ rectangular, fabricated with galvanised steel wire 4 mm dia complete all as specified and directed.
M&L for chemical earthing with earth electrode made of low carbon steel circular rods, molecularly bonded with copper on outer with minimum thickness of 250 micron, 17 mm dia, 3 metre long including drilling of bore hole of 150 mm dia of 20 metre depth, filling the bore hole with black cotton soil up to 17 metres level i.e. below the electrode bottom level, placing electrode by penetrating 150 mm into black cotton soil, filling earth enhancement material (minimum approx. 30 kg) into the augured hole in slurry form and allowed to set, minimum 125 mm dia covering of the composite structure (earth electrode + earth enhancement material), covering remaining portion with backfill soil/ material, welding copper strip of 150 x 25 x 6 mm to electrode, construction of earth pit including testing complete all as specified and as directed.
S&F of earth continuity conductor or main earthing lead of 32 x 6 mm galvanized iron strip and making proper arrangements for connection between earthing and transformer / equipment complete all as specified and directed.
S&F in replacement 1100 Volts grade heavy duty cable, PVC insulated aluminum conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4 mm glavanized steel suspension wire, one twin core cable flat or circular of size of aluminum conductor 6 sq mm stranded conductor complete all as specified and directed.
S&F in replacement 1100 Volts grade heavy duty cable, PVC insulated aluminum conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4 mm glavanized steel suspension wire, one twin core cable flat or circular of size of aluminum conductor 10 sq mm stranded conductor complete all as specified and directed.
M&L for repairing of outdoor type LT pannel board mounted on angle/ PCC floor of any size with and including replacement of unserviceable switch/ control gears and connector, indicator lamps, panel door lock etc. including rewiring and extension of incoming and out going cables by opening of loops/ making joints with same size cable and provisioning of cable lugs/ thimbles as reqd and replacement of rusted sheet metal door with existing size using MS sheets by necessary arc/ gas welding and making cover of suitable size and removing all dirt, dust etc with the help of air blower and painting complete panel board with two coats of synthetic enamel spray painting over a coat of red oxide primer to panel Board of approved colour including writing of identification marks complete all as specified and directed. Panel board is comprising of the following components:- (a) MCCB, 100 to 400 A, 3/4 pole, 415 Volt - 04 to 06 Nos (b) Indicator Lamp, RYB, LED type with fuse - 01 set (c) Aluminium bus bar, RYB & N of 200 A - 01 set (d) Amp / Volt meter - 02 Nos (e) MCB TPN/ SPN/ SP mounting on bus bar - 01 to 6 Nos (f) Door lock - 4 to 8 Nos Notes: (i) Necessary eqpt and safety measures for load balancing shall be arranged by the contractor without any extra cost. (ii) Cost of new aluminium/ copper thimbles, earth and neutral link, insulator, hylem sheet, any type of screws, door locks any type as required as per site requirement shall be changed under the job deemed to be included in the quoted rate. (iii) MCCB, MCB, aluminium bus bar, indicator lamp, required for relacement shall be measured and paid serately in relevent items.
S&F in replacement LED type indicating lamp for indication of RYB complete all as specified and directed.
S&F in replacement aluminium bus bar of 200 Amps rating, 25/ 6 mm including making suitable holes in panel and providing tape insulation of suitable colour in Phase RYB & neutral in black colour complete all as specified and directed.
S&F of steel tubular pole, swaged type 410-SP-31 (9 meter long) with cast iron base plate, finial taper plug, bolts, nuts, washer and screws including painting with two coats of aluminium paint over one coat of red oxide primer on all exposed surfaces and tarring with black bituminous paints to portion embedded in PCC, numbering of poles in 100mm diameter yellow circle with black paint including 15 cm wide alternate black & yellow bands upto 1.5m height from ground level complete all as specified and directed. Note :- Excavation, earth work and PCC shall be measured and paid separately.
M&L for preparation of old painted steel surfaces of iron gate, rolling shutter, chain link fencing etc. And applying one coat of synthetic enamel paint complete all as specified and directed.
S&F of mild steel framed work as in gates, grills, guard bars, gratings, ladders, MS clamp for supporting of cable etc; with ends of bars shouldered and/or riveted or forged into spikes including dismantling of old steel frame work complete all as specified and directed
S&F in replacement of old unserviceable lugs after cutting the worn out / faulty cable end from LT pillar/ panel box including necessary earth work for taking out the cable from loop line, returning, filling in and making cable lead by providing aluminium lugs including crimping with crimping tools in the existing LT cable upto 50 Sqmm, 3.5 core including making necessary connections complete all as specified and directed.
S&F in replacement of old unserviceable lugs after cutting the worn out / faulty cable end from LT pillar/ panel box including necessary earth work for taking out the cable from loop line, returning, filling in and making cable lead by providing aluminium lugs including crimping with crimping tools in the existing LT cable upto 70 to 120 Sq mm, 3.5 core including making necessary connections complete all as specified and directed.
M&L for earthing complete with galvanised steel plate earth electrode 600 x 600 x 6 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised earthing strip of dimension 32 x 6 mm by means of bolts, nuts, check nuts and washers of galvanised iron from earth plate to test point upto 7.5 metre including all as shown in electrical plate No. 3 of SSR Part I (2009) including necessary concrete chamber in cement concrete M-15 (Nominal Mix) using 20 mm graded stone aggregate, precast RCC cover slab in cement concrete M-15 (Nominal mix) using 20 mm graded stone aggregate of size 40 cm X 40 cm X 5 cm duly reinforced with 8 mm dia TMT bars @ 150 mm c/c both ways with one handle for lifting made out of 8 mm dia bar, GI funnel, GI wire mesh filter, 20 mm dia GI pipe medium grade for watering, 20 mm dia GI pipe medium grade for protection of earthing lead, charcoal or coke and salt in alternate layers including testing complete all as specified and directed. Note: Necessary excavation to be measured and paid seperately.
S&F in replacement of IP 66 oval shape thermoplastic PC-GFS polycarbonate weather proof junction box of approx size 130 x 180 x 77 mm with degree of protection against mechanical load – IK 09 (10 Joule) with multi level knockouts for cable glands in different sizes, pre-moulded knockouts shall be available on all the four sides of the junction box to enable cable entries from any direction and lid fasteners shall not have screws but shall be with visible quarter turn locking knobs (open locked) and sealable without any accessories, box shall have elongated holes inside them for wall mounting provision however external brackets for wall fixing must be included and integrated inside complete all as specified and directed. Note: Junction box shall be weatherproof: UV resistant due to solar radiation, rainwater proof, temperature resistant, salt water proof & shall be suitable for off-shore applications, IEC: 60670-22: Particular requirements for connecting boxes and enclosures, IEC: 60695-2-11: Flame-retardant & self-extinguishing, glow wire tested at minimum 960 deg C, degree of protection against mechanical load - IK: 09 (10 Joule) in accordance with IEC: 62262, colour- RAL 9011 black, IEC: 60529: IP-66 degree of protection.
S&F in replacement of polycarbonate thermoplastic weather proof junction boxes IP-65/ 66 for street lights of approx size not less than 210 x 155 x 92 mm with metric knock outs for cable entry, weather proof for outdoor installation, glands and with 4 terminals, terminal rating 32 Amps for three phase and neutral mounted with locking arrangement including fixing to the poles by means of suitable size of clamps, nuts and bolts with and including 01 No. MCB, SP, 6 - 32 Amps,10 KA capacity complete all as specified and directed.
M&L for factory made precast cable route indicator of cement concrete 1:2:4, type B-1 (using 20 mm graded stone aggregate) having 10 cm square shape at top and 20 cm square shape at bottom and total height of 90 cm and grouted into PCC 1:2:4, type B-1 (using 20 mm graded stone aggregate) 35 cm below ground level as per site requirement including embossed with 'LT 1100 V cable' including painting in synthetic enamel paint and necessary excavation, earth work in any type of soil complete all as specified and directed.
S&F of factory made RCC earth pit chamber with cover of size 450 mm x 450 mm x 150 mm & 50 mm thick including necessary excavation, earth work & PCC work for grouting & packing complete all as specified and directed.
S&F in replacement factory made RCC earth pit chamber with cover of size 450 mm x 450 mm x 150 mm & 50 mm thick including necessary excavation, earth work & PCC work for grouting & packing complete all as specified and directed.
Labour only for attending day to day complaints for repairing of street light, security light, post top lantern, perimeter lights for repair of any size/ wattage including tighting of loose electric connection, clearing carbon deposition and any other minor work required to make light functional after rectifying the defects of the electrical system including replacement of the unservicable items such as street light, flood light, LED drivers, MCBs any capacity, connection plate, thimbles, minor repair of timer switch and small pieces of electrical cables with PVC insulated copper multistranded conductor of sizes 1.5 Sqmm to 2.5 Sqmm three core of length not exceeding 1.5 mtrs for smooth functioning at SI Line Military Station by deputing skilled and qualified electrician alongwith helper at any time in working hours as per site requirement complete all as specified and directed. Notes:- (i) It is compulsary to attend manimum five nos complaints in a day within 24 hrs after intimation otherwise penalty of Rs. 250.00 per day for non-attending the complaints will be levied on contractor. (ii) Complaints will be reported on daily basis with complaint register. (iii) Minor items such as insulating tape, screws, small pieces of electrical cables PVC insulated copper multistranded conductor of size 2.5 Sqmm three core upto length of 1.5 m etc as required to attend the complaint is included in quoted rates. (iv) Street light, flood light, LED drivers, MCBs any capacity, connection plate or any major items required for replacement will be paid seterately under respective item of Schedule 'A'.
M&L for overhauling of high mast lighting system not less than 16 meters height by degreasing and cleaning of double drum winch, gear box, wire rope, clamps, bobbin arrangement, power tool motor, mechanical torque limiter, lowering the mast head assembly, degreasing and cleaning the pulley, docking arm etc. and applying new grease / lubricating oil for all mechanical moving/ rotating parts, checking all the electrical parts such as timer panel, all cable connections in control panel, motor, junction box, flood light fittings and aviation obstruction light fitting etc, rectifying the defects, renewing the defective components including testing for proper functioning complete all as specified and directed. Note: Replacement of flood light fittings, aviation obstruction light, control cable, steel wire rope, timer panel components and rewinding of motor if required at site will be measured and paid seperately under respective items of Schedule 'A'.
S&F of integral LED street light luminaire of not less than 45 W, system efficacy not less than 120 lm per watt, comprising of die cast alluminium housing, enclosed with IP-66, IK08, THD<10%, PF>0.95 protection suitable for voltage range should be 170 to 240 Volts, CCT >= 5700K, 4 kv inbuilt and 10 kv external surge protection complete with all fixing arrangement such as nuts, bolts and washers including making connection with 2.5 sqmm PVC aluminium stranded conductor, 3 core of minimum 2.0 m length on pole including testing complete all as specified and directed.
S&F of integral LED street light luminaire of not less than 60 W, system efficacy not less than 120 lm per watt, comprising of die cast alluminium housing, enclosed with IP-66, IK08, THD<10%, PF>0.95 protection suitable for voltage range should be 170 to 240 Volts, CCT >= 5700K, 4 kv inbuilt and 10 kv external surge protection complete with all fixing arrangement such as nuts, bolts and washers including making connection with 2.5 sqmm PVC aluminium stranded conductor, 3 core of minimum 2.0 m length on pole including testing complete all as specified and directed.
S&F of integral LED street light luminaire of not less than 70 W, system efficacy not less than 120 lm per watt, comprising of die cast alluminium housing, enclosed with IP-66, IK08, THD<10%, PF>0.95 protection suitable for voltage range should be 170 to 240 Volts, CCT >= 5700K, 4 kv inbuilt and 10 kv external surge protection complete with all fixing arrangement such as nuts, bolts and washers including making connection with 2.5 sqmm PVC aluminium stranded conductor, 3 core of minimum 2.0 m length on pole including testing complete all as specified and directed.
S&F of integral LED street light luminaire of not less than 90 W, system efficacy not less than 120 lm per watt, comprising of die cast alluminium housing, enclosed with IP-66, IK08, THD<10%, PF>0.95 protection suitable for voltage range should be 170 to 240 Volts, CCT >= 5700K, 4 kv inbuilt and 10 kv external surge protection complete with all fixing arrangement such as nuts, bolts and washers including making connection with 2.5 sqmm PVC aluminium stranded conductor, 3 core of minimum 2.0 m length on pole including testing complete all as specified and directed. Note: LM 79 and 80 report with NABL certified lab and NABL certificate will be submitted by the contractor.
S&F of integral LED flood light luminaire of 50 W, system efficacy not less than 120 lm per watt as per IS-16107, IP-66 degree of protection with pressure die cast aluminium housing and toughened glass, THD <10%, PF >0.95, 5700 - 6500 K colour temperature, CRI 70, HV cut off @ 320 V/ Low V cut complete with all fixing arrangements such as nuts, bolts, washers, clamps for fixing and making connection with 2.5 sqmm PVC aluminium stranded conductor, 3 core of minimum 2.0 m length on pole including testing complete all as specified and directed.
S&F of integral LED flood light luminaire of 100 W, system efficacy not less than 120 lm per watt as per IS-16107, IP-66 degree of protection with pressure die cast aluminium housing and toughened glass, THD <10%, PF >0.95, 5700 - 6500 K colour temperature, CRI 70, HV cut off @ 320 V/ Low V cut complete with all fixing arrangements such as nuts, bolts, washers, clamps for fixing and making connection with 2.5 sqmm PVC aluminium stranded conductor, 3 core of minimum 2.0 m length on pole including testing complete all as specified and directed.
S&F of integral LED flood light luminaire of 150 W, system efficacy not less than 120 lm per watt as per IS-16107, IP-66 degree of protection with pressure die cast aluminium housing and toughened glass, THD <10%, PF >0.95, 5700 - 6500 K colour temperature, CRI 70, HV cut off @ 320 V/ Low V cut complete with all fixing arrangements such as nuts, bolts, washers, clamps for fixing and making connection with 2.5 sqmm PVC aluminium stranded conductor, 3 core of minimum 2.0 m length on pole including testing complete all as specified and directed.
S&F of integral LED flood light luminaire of 200 W, system efficacy not less than 120 lm per watt as per IS-16107, IP-66 degree of protection with pressure die cast aluminium housing and toughened glass, THD <10%, PF >0.95, 5700 - 6500 K colour temperature, CRI 70, HV cut off @ 320 V/ Low V cut complete with all fixing arrangements such as nuts, bolts, washers, clamps for fixing and making connection with 2.5 sqmm PVC aluminium stranded conductor, 3 core of minimum 2.0 m length on pole including testing complete all as specified and directed.
S&F of integral LED flood light luminaire of 400 W, system efficacy not less than 120 lm per watt as per IS-16107, IP-66 degree of protection with pressure die cast aluminium housing and toughened glass, THD <10%, PF >0.95, 5700 - 6500 K colour temperature, CRI 70, HV cut off @ 320 V/ Low V cut complete with all fixing arrangements such as nuts, bolts, washers, clamps for fixing and making connection with 2.5 sqmm PVC aluminium stranded conductor, 3 core of minimum 2.0 m length on pole including testing complete all as specified and directed. Notes for ser item Nos. 51 to 59:- (i) LM 79 and 80 report from NABL certified lab and NABL certificate will be submitted by the contractor. (ii) Contractor will produced original manufacturer test certificate and warranty card for two years for all lighting luminaires.
M&L for painting of steel pole (swan neck type or straight type) up to 9 mtr height with cross arms, clamp of any length and shape for LT overhead line/street light with two coats of aluminium paint after scratching out old paint after cleaning the existing surface rust free, preparation of the surface including marking pole numbers in a 20 cm dia yellow circle with number writing with black synthetic paint & painting strips in alternate from bottom to top with three strips of black synthetic paint & two strips of white fluorescent paint (up to 1.5 mtr height) throughout the circumference of pole (width of each strip shall be of 30 cm) including one coat of lime wash on PCC copping of pole complete all as specified and directed.
M&L for preparation of old painted surfaces LT PCC poles and applying two coats of aluminium paint & providing alternative bend of 30 cm width (3 black and 2 white) from bottom of pole to 1.5 mtr height with two coat painting with synthetic enameled paint, writing of pole numbers in yellow circle 15 cm with black paint on poles complete all as specified and directed.
S&F in repairs MCCB, 160 Amps, 4 Pole, 36 KA, 415 V, thermal magnetic release type, Ics=100 % Icu, with adjustable overload setting and adjustable short circuit setting and protection against ground fault including spreader terminals and phase barriers complete all as specified and directed.
S&F in repairs MCCB, 200 Amps, 4 Pole, 36 KA, 415 V, thermal magnetic release type, Ics=100 % Icu, with adjustable overload setting and adjustable short circuit setting and protection against ground fault including spreader terminals and phase barriers complete all as specified and directed.
S&F in repairs MCCB, 250 Amps, 4 Pole, 36 KA, 415 V, thermal magnetic release type, Ics=100 % Icu, with adjustable overload setting and adjustable short circuit setting and protection against ground fault including spreader terminals and phase barriers complete all as specified and directed.
S&F in repairs MCCB, 400 Amps, 4 Pole, 36 KA, 415 V, thermal magnetic release type, Ics=100 % Icu, with adjustable overload setting and adjustable short circuit setting and protection against ground fault including spreader terminals and phase barriers complete all as specified and directed.
S&F in repairs LT cable straight through jointing kit, heat shrinkable outdoor type complete with jointing material and accessories suitable for XLPE armoured aluminium conductor LT cable of size 10 to 50 Sqmm x 3.5 core complete all as specified and directed.
S&F in repairs LT cable straight through jointing kit, heat shrinkable outdoor type complete with jointing material and accessories suitable for XLPE armoured aluminium conductor LT cable of size 70 to 120 Sqmm x 3.5 core complete all as specified and directed.
S&F in repairs bracket made of GI pipe, light grade, 1.2 mtr long of 32 mm bore, bend to required shape as per site requirment and fixed to pole with flat iron 40 x 5 mm (02 Nos) clamps, bolts, nuts, washers including painting with two coats of aluminium paint over a coat of red oxide primer complete all as specified and directed.
S&F in repairs 40 mm bore GI tubing, light grade with all fittings as required for passing through cables under floors, along the wall/ pole, etc with suitable size M.S. flat iron clamps including nuts, bolts and washers complete all as specified and directed.
S&F in repairs 50 mm bore GI tubing, light grade with all fittings as required for passing through cables under floors, along the wall/ pole, etc with suitable size M.S. flat iron clamps including nuts, bolts and washers complete all as specified and directed.
S&F in repairs 80 mm bore GI tubing, light grade with all fittings as required for passing through cables under floors, along the wall/ pole, etc with suitable size M.S. flat iron clamps including nuts, bolts and washers complete all as specified and directed.
M&L for cutting/ pruning of tree branches upto the extend for obtaining clearance all around the LT/ HT over head lines conductor upto 3 mtr from farthest conductor on pole including removing of cut branches and cleaning of site complete all as directed. Notes:- (i) Trees branches will be left as it is and will not be carried away by the contractor / DEL as the wood belongs to CEO/ DEO. (ii) Contractor or his rep will take proper shut down from MES installation before starting the work and clear it before resuming power supply. (iii) The contractor will provide proper tools and safety devices to his staff for pruning of trees.
S&F in repairs LED driver suitable for 45 - 60 Watts existing LED security/ street lights fitting of any make and model complete all as specified and directed.
S&F in repairs LED driver suitable for 70 - 90 Watts existing LED security/ street lights fitting of any make and model complete all as specified and directed.
S&F in repairs LED driver suitable for 100 - 120 Watts existing LED security/street lights fitting of any make and model complete all as specified and directed.
S&F in repairs MCB, SP, 6 - 32 Amps, 'C' curve, 240 Volts, 10 KA capacity complete all as specified and directed
S&F in repairs PVC insulated and PVC sheathed 2.5 Sqmm, 3 core stranded aluminium conductor cable complete all as specified and directed
S&F in repairs contactor, 16 Amps, single phase, 240 Volts as per IS: 13947-4-1 suitable for nature time switch Model: Swadeep - 02 complete all as specified and directed.
S&F in repairs contactor, 25 Amps, triple phase, 415 Volts as per IS: 13947-4-1 suitable for nature time switch Model: Swadeep - 02 complete all as specified and directed.
S&F in repairs sensor for automatic street light control panel, single phase as per site requirement including testing for automatic functioning of street light on timer complete all as specified and directed.
S&F in repairs sensor for automatic street light control panel, triple phase as per site requirement including testing for automatic functioning of street light on timer complete all as specified and directed.
S&F of integral LED Solar Street light consisting of solar photovoltaic module battery, battery management system, control electronics, LED driver, PIR sensor, inter connecting cables and pole mounting piece integrated into the luminaire as a single unit comprising of solar street light with IP-65 protection having a system wattage of 27 - 29 watts with not less than 4500 lumen output, high efficiency mono-crystalline solar panel, highly efficient MPPT based charge controller and 12.8 Volts, 30 lithium ferro phosphate battery, LED lumen efficacy shall be aleast 175 Lm/W with suitable LED driver, housed in IK-08 impact reistance certified aluminium pressure die-cast housing with anti corrosive coating and have a UV stabilized polycarbonate cover specially designed pole mounting piece that enabled lateral as well as post top mounting and installation at varying from 0 to 15 degrees for optional light distrinution complete all as specified and directed. Note: LM 79 and 80 report from NABL certified lab and NABL certificate will be submitted by the contractor.
S&F in repairs LED aviation light, 11 watts having die cast aluminium housing with red polycarbonate dome for better illumination, integral LED driver, IP-65 protection, operating voltage range 100 - 270 Volts AC, mounted on highmast pole with all connected accessories complete all as specified and directed.
M&L for providing coping of LT/HT pole of PCC 1:2:4, type B-1 (uisng 20 mm graded stone aggregate) of size 600 x 600 x 300 mm including necessary form work and 10 mm thick rendering plaster in CM 1:4 and applying two coats of white wash complete all as specified and directed.
Deduct Schedule of credit (calculation will be done off line) Rs. 22855.00
S S TRADERS (BID ID -3463673)
PRAGATI ELECTRICALS AND ELECTRONICS (BID ID -3463674)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.25 MB
BOQ_822662.xls
BOQ • 5.88 MB
TENDER_DOCU_8444.pdf
Tender Documents • 0.85 MB
CREDIT8444.pdf
Tender Documents • 0.16 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .