| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹46.5 LAccepted-AOC BIDHAN PALLY OODLABARI P O MANABARI P S MALBAZAR DIST JALPAIGURI | JALPAIGURI | ₹46.5 L Quoted ₹48.1 L | L1 | Accepted-AOC Accepted |
| 2 | L2₹49.2 L+₹1.1 L (2.28%)Rejected-Finance | ₹49.2 L+₹1.1 L (2.28%) | L2 | Rejected-Finance Not Lowest |
| 3 | L3₹49.5 L+₹1.4 L (3.00%)Rejected-Finance C O UTTAM BANIK HAIDERPARA OPPOSITE TO WEST BENGAL REPRESENTATIVE REST HOUSE P O HAIDERPARA SILIGURI 06 | JALPAIGURI | WEST BENGAL | 734006 | ₹49.5 L+₹1.4 L (3.00%) | L3 | Rejected-Finance Not Lowest |
| 4 | L4₹50.0 L+₹1.9 L (4.04%)Rejected-Finance | ₹50.0 L+₹1.9 L (4.04%) | L4 | Rejected-Finance Not Lowest |
| 5 | L5₹51.5 L+₹3.4 L (7.04%)Rejected-Finance | ₹51.5 L+₹3.4 L (7.04%) | L5 | Rejected-Finance Not Lowest |
Tender Value
₹46 L
EMD Value
₹92,000
Closing Date
7 Sept 2022, 6:00 pmClosed
GE SEVOKE ROAD
GE Sevoke Road Post Salugara Dist Jalpaiguri PIN 734008
SPL REPAIR TO BLDG NO NH 39 AND NH 40 AND NH 53 AND EXTERNAL ELECTRIC DISTRIBUTION SYSTEM WORK AND CERTAIN MINOR WORKS AT BAGRAKOTE STN UNDER GE SEVOKE ROAD
2022_MES_544615_1
GE/SEV/25 of 2022-23
Open Tender
Civil Works
Item Rate
GE SEVOKE ROAD
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
Yes
GE SEVOKE ROAD
₹92,000
Yes
17 Oct 2022
11 Aug 2022
9 Sept 2022
11 Aug 2022
7 Sept 2022
1 Sept 2022
12 Aug 2022 - 22 Aug 2022
Amount
Excavating in trenches not exc 1.50m wide and n.exc 1.50m in depth in hard/dense soil and getting out complete all as specified and as directed.
M&L for PCC 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) as in foundations, filling and mass concrete etc complete all as specified and as directed.
M&L for brick work with fly ash bricks straight or curved on plan exc. 6mtr mean radius, built in cement mortar 1:6, complete all as specified and directed.
M&L for Brick work with fly ash bricks as in half brick thick wall built in CM (1:4), complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and directed.
Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed.
M&L for moorum/red bajri filling in floor or paving laid in layers n exc 15 cm thcik spread levelled and blinded with earth and rammed including watering complete all as specified and as directed.
M&L hardcore of broken stone or boulders of gauge not exceeding 63 mm deposited, spread and levelled in layers not exceeding 15cm thick, watered and rammed to a true surface complete all as specified and directed.
M&L for 75mm thick PCC (1:4:8) type D-2 (using 40mm graded mechanically crushed stone aggregate) as sub base of flooring complete all as specified and directed.
M&L for 50mm thick PCC (1:4:8) type D-2 (using 40mm graded mechanically crushed stone aggregate) as sub base of flooring complete all as specified and directed.
M&L for 40mm thick PCC (1:2:4) type B0(using 12.50mm graded crushed stone aggregate) as in DPC to horizontal or verticle surfaces including necessary formwork complete all as specified and directed.
M&L RCC 1:2:4 type B1 (using 20 mm gradded crushed stone aggregated ) as in lintels upto 1.5m clear span and lintel band, roof band, plinth courses string courses, lacing courses, parapets and railling upto 60 cm in height coping, kneelers, apex stones, bed plates, kerbs, water through, slightly rounded or chamfered angels and throating complete all as specified and as directed.
M&L for mild steel TMT bars 10mm dia and over, cut to length, bent to shape required incl cranking, bending spirally for hooping for columns, hooking ends and binding with and incl mild steel wire annealed, not less than 0.9mm dia or securing with clips complete all as specified.
All as per item No.13 above but 5 mm dia and over up to and including 10 mm dia as in stirrups, spacers and binders complete all as specified and as directed.
S&F rolled mild steel Roof trusses (framed), trussed, purlins, crane, gantries, rails and fastening and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc( Fe 410-W Gde-E-250) quality A Including preparation of surface and one shop coat of zinc chromate primer at contractors workshop before fabrication complete all as specified and directed by Engineer-in-Charge..
S&F Steel ventilators with top hung shutter including hinges,steel peg stay and one coat of red oxide primer complete all as specified.
S&F mild steel screw bolt, 5 to 10mm dia machine made with hexagonal head at one end screwed the other or screwed both end, each screwed end to be fitted with washer and one hexagonal or square nut exceeding 05cm and not exceeding 10cm long complete all as specified.
S&F pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering fixed with self drilling and self tapping screws, neoprene and limpet washers complete all as specified and directed.
S&F mild steel flat iron (conforming to Fe -290 Gde-E-165) for securing fencing post or wind tie including drilling holes, for screwing bolts etc complete all as specified and directed.
M&L for rendering 20mm thick on fair faces of brick work or concrete surfaces in CM 1:4 including mixing WPC as per manufacturers instruction, finished even and smooth without using extra cement complete all as specified and as directed. Note : WPC shall be measured seperately.
M&L rendering 15mm thick in CM 1: 6 on fair faces of brick/concrete surfaces finished even & smooth without using extra cement complete all as specified and as directed.
Supply only Liquid water proofing compound complete all as specified and as directed.
M&L for rendering in CM (1:4), 10mm thick on fair faces of brick work or concrete surfaces for fixing of wall tiles complete all as specified and as directed.
M&L for glazed ceramic coloured tiles on vertical surface 300X450X7 mm thick set and jointed in neat cement slurry and pointed in coloured cement to match the surfaces complete all as specified and as directed.
M&L for screed bed or bedding layer of cement mortar 1:6, 15mm thick for laying floor finishes complete all as specified and as directed.
M&L for non skid ceramic coloured tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.11sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in coloured cement to match the surfaces complete all as specified and as directed.
M&L 75mm thick cement concrete 1:3:6 type C-2 (using 40mm graded crushed stone aggregate) as in plinth protection & paving finished even & smooth without using extra cement complete all as specified and as directed.
M&L for mild steel round bars, 6 mm dia, as in reinforcement to half brick wall (two Nos in every fourth course of half brick wall) complete all as specified and as directed.
S & F factory made solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, supplying and fixing in opening as per specification & drawing complete all as specified and directed.
S&F Factory Made Solid Panel PVC Door Shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails, M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet shall be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading and joined together with solvent cement, as per specification & drawing complete all as specified and directed.
S&F stainless steel butt hinges medium weight cold rolled of size 100mm complete all as specified and directed.
S&F aluminium anodised handles of 100mm size, fabricated type of extruded section fixed with screws to shutters, complete all as specified and directed.
S&F aluminium anodised barrel tower bolts of extruded section, 150mm long, complete all as specified and directed.
S&F vitreous china squatting pan "ORISSA" pattern of size 580x440mm white with and including 'P' or 'S', trap with integral foot rests (excluding flushing cistern & flush pipe) including provision of lime concrete bedding and connecting up, complete all as specified and directed.
S & F flushing cistern, 10 Ltrs. Capacity, PVC valveless, syphonic action type with dual flushing system, low level,white with inlet, ball valve,float and handle including brackets and flush pipe of polyethylene PVC 32mm dia, complete all as specified and directed.
S&F PVC connection pipe 15 mm dia, 450 mm long with PTMT nut complete all as specified and as directed
S&F 15 mm dia GI pipe medium grade with all fittings and fixed to wall/ceiling or laid in floor complete all as specified.
S& F in repair 15 mm bore bib tap cast copper alloy with crutch or butterfly handle screwed down screwed for iron pipe complete all as specified and directed.
S& F in repair 15 mm bore angle stop valve cast copper alloy with crutch or butterfly handle screwed down screwed for iron pipe complete all as specified and directed.
S&F brass chromium plated, shower rose, 125mm size, complete all as specified and directed.
Preparation of newly plastered surfaces and applying three coats of white wash on walls complete all as specified and as directed
M&L for preparation new steel surfaces of any description over 10cm width of grith and applying two coat of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
S&F PVC (SWR) floor trap dia of outlet 75mm, plain with grating including jointing with solvent cement complete all as specified and as directed.
Supply and fixing CP soap dish fixed to wall with screws complete all as specified.
S&F aluminum anodised Tubular towel rail, 20mm dia, D type, 60cm long between flanges complete all as specified and as directed.
S&F 20 mm bore medium grade galvanized steel water tubing with all fittings and fixed to wall/ceiling or laid in floor complete all as specified.
S&F Rotational moulded polyethylene water storage tanks 1000 Litre capacity double layer (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part-I including provision of necessay fittings for connection the overflow, drain out, inlet and outlet pipes, complete all as specified and as directed.
S&F 20 mm bore Gun metal gate or globe valve with iron wheel head screwed both ends for iron pipe complete all as specified and directed.
M&L for 25 mm bore ball valves high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe complete all as specified and directed.
S&F 25 mm bore Gun metal gate or globe valve with iron wheel head screwed both ends for iron pipe complete all as specified and directed.
S&F 75mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints laid in trenches or in floors complete all as specified and as directed
S & F 75 mm bore PVC (SWR) Vent cowl complete all as specified & directed
S & F 110 mm bore PVC (SWR) bends of any radius complete all as specified & directed.
S&F 110mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints laid in trenches or in floors complete all as specified and as directed
M&L fo cement concrete 1:4:8 (type D-2) as in bed for drain pipes including packing under and hauncing against the sides of pipes after they are laid and tested for 110mm bore pipe complete all as specified and directed.
Excavation over areas not exceeding 1.5m deep and getting out in hard/dense soil complete all as specified and as directed
All as per item No 56 above but exceeding 1.5m deep and not exc 3.0m in depth getting out in hard/dense soil complete all as specified and directed.
M&L PCC 1:3:6, type C-2 (using 40 mm graded crushed stone agg) as in foundation, filling and mass concrete complete all as specified.
S&F Modular Septic Tank of Capacity 2000 Ltrs (9-10 Users) (plastic septic tank) vertical design tank type includng all accessoried and lowering into position and fixed to inlet and outlet pipes complete all as per manufacturer instructions and directed by Engineer-in-Charge. Make:- Supreme/ Sintex Plastics/ Aqua tech.
Excavation in trenches n.exc 1.5 m wide and n.exc 1.5m in depth for foundation, shafts, wells, cesspits, manholes, pipes, poles and cables etc n.exc 10 sqm on plan and n exc 1.5 in depth and getting out in soft / loose soil complete all as specified and as directed.
All as per item No 60 above but depth exc 1.5m n exc 3.0m complete all as specified and as directed.
M&L for Brick work with sub class 'B' bricks, straight or curved on plan exc 6m mean radius built in CM 1:4 complete all as specified and directed.
M&L for brick work with sub class 'B' bricks in one brick thick honey comb walling built in cm 1:4 complete all as specified and directed.
M&L for RCC M25 (Nominal Mix) in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and as directed.
Use and waste formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200 mm thick (Horizontal or sloping for flat surface) complete all as specified and directed.
S&F mild steel TMT bars 6mm to 8 mm dia , cut to length,bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed.
M&L for loose filling with broken bricks aggregates of gauge 80 to 150 mm in soakage pits, soakage wells complete all as specified and directed.
S&F CI manhole cover 600 mm dia medium grade all as specified and as directed.
M&L 150mm internal dia of salt glazed stone ware drain pipes grade A laid in trenches and jointed complete all as specified and as directed.
M&L for spreading and levelling of earth filling in layers n exc 25 cm thick complete all as specified and as directed.
M&L 40mm thick PCC 1:2:4, type B1 (using 20mm graded agg) as in sub base of floor complete all as specified.
M&L for glass dividing strips 38mm wide and 3 mm thick and inserted in position to conform to design complete all as specified and as directed.
S&F Mild steel bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required, hooks (stay), heavy, for large gates, hook and pintle hinges, large hasps and staples, chains, hand made sliding bolts, clamps, hold fasts, wall ties, hooks for hanging fans, plain angle cleats for securing purlines to steel trusses or rafters, knee piece inserts, two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165.
M&L for PCC 1:3:6 type C1 (using 20mm graded crushed stone aggregate) as in block for hold fast, filling in frames, copings or similar work and finished the surface with existing including form work. complete all as specified
S&F pressed steel frames (Size-105X60mm) for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate etc complete all as specified .
S&F factory made 2nd class hard wood rail and style 35mm thick plain framed, panelled shutter (two panel ) with lock rail and panel of 9mm B.W.P. commercial ply or 12mm veneered particle board with commercial veneering on both faces. The size of rail and style as per IS:1003 (part I), kiln seasoned and chemically pressure treated complete all as specified.
S&F mild steel tower bolts stove enamelled black with bright bolt 200 mm long complete all as specified and as directed.
S&F 300 mm long mild steel sliding door bolts plate type stove enamelled black with bright bolts not less than 12mm dia with and including a minimum of 6 bolts nuts, four on bolts plate & two on staple plate complete all as specified and as directed.
S&F mild steel pressed handle oval type stove enamelled black 150 mm long complete all as specified and as directed.
S&F Steel windows with side hung shutters including box type hinges with steel handle, and steel peg stay, including one coat of red oxide primer complete with glazing bars, dovetailed or welded complete all as specified and directed.
S&F 3mm thick glass sheet ordinary quality & glazing with oil putty in square not exc 0.50 Sqm in each pane all as specified & directed.
S&F mild steel framed work such as grills, gratings, etc., with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe 290 Gde-E-165 complete all as specified and directed.
S&F pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering fixed with self drilling and self tapping screws, neoprene and limpet washers complete all as specified and directed.
M&L for preparing new steel and iron surfaces of any description n.exc 10 cm in width or girth and apply two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed.
M&L for preparation of new untreated wood and wood base material of any description not otherwise described, over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and as directed.
Taking down chowkats with shutters (without taking off shutters from the frames) area not exceeding 1.50 Sqm each complete all as specified and as directed.
Taking down chowkats with shutters (without taking off shutters from the frames) area exceeding 1.50 Sqm but not exceeding 4.00 Sqm each complete all as specified and as directed.
S& F 2nd class hard wood (SAL) small fittings such as bracket of any type latch hinges blocked shapped door& window stopper and cleat including all necessary labour articles not exceeding 200 cu cm each complete all as specified.
Dismantling plain or corrugated steel sheeting any gauge or thickness as in roof covering complete all as specified and as directed.
Dismantling timber scantling 40 Sqcm and over in section in any position as in framed works complete all as specified and as directed.
Dismantling of wrought iron or mild steel work of any description not other wise provided for complete all as specified and as directed.
S&F pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering bent to curve fixed with self drilling and self tapping screws, neoprene and limpet washers complete all as specified and directed.
Demolition of cement concrete in ground floors and pavings n. exc 15 cm thickness (below or above GL) complete all as specified
Demolition of brick work or stone/boulder masonry built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc. but excluding ashlar facings, dressed stone work and precast concrete articles complete all as specified.
Taking down cement plaster of any description including raking out joints, hacking for key, scrubbing down with water etc complete all as specified
Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc complete all as specified.
M&L for brushing neat cement slurry with 3.0kg of cement per sq metre complete all as specified and directed
M&L for Machine cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and as directed. Note:- Screed bed shall be measured separately.
M&L for Kota stone slab 20-25mm thick in riser of steps, skirting, dado and pillar laid over cement screed and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and as directed. Note:- Screed bed shall be measured separately.
Preparation of old treated surfaces and applying one coat of white wash on walls complete all as specified and as directed
Surface dressing n exc 15cm deep in hard/dense soil complete all as specified and directed.
M&L for PCC 100mm thick cement concrete 1:4:8 type C-2 (using 40mm graded crushed stone aggregate) as in path/ hardstanding/sub base complete all as specified
M&L for Sand filling under floors including watering and consolidation as in sand cushioning for interlocking paver blocks complete all as specified and directed.
M&L 60mm thick Machine pressed precast concrete interlocking paver block with grey cement and pigment any shape and size conforming to IS 15658- 2006 M-35 grade, laid as directed to any shape. Complete all as specified and as directed
M&L for Continuous brick edging; with width equal to the depth of the brick, laid dry, on edge with fly ash modular bricks complete all as specified and as directed.
Taking down carefully copper/Aluminum point wiring (light fan, socket or power) complete (fittings such as switches ceiling roses pendants, regulators, sockets, sketch light fittings, tube light fittings etc) to be measured separate if found serviceable and removing unserviceable materials from site of work and segregating serviceable materials for safe custody and making good to disturbed surfaces of walls, floors, etc. including disconnecting of ceiling fan/exhaust fan complete all as directed
M&L for concealed point wiring with single core PVC insulated, unsheathed, multistranded copper conductor FRLS of size 1.5 sqmm and one single core PVC insulated unsheathed stranded copper conductor of size 1.50 sqmm green in colour as earth lead in and including PVC rigid Concealed conduit (medium grade) of suitable size, with all fittings and accessories including provision of mild steel sheet duly galvanised terminal box suitable for fixing switches/sockets/ regulators etc, fixed in recess of wall with brass chromium plated screws and cup washer comple for one light/fan point controlled by one switch cpmplete all as specified. NOTE : Cost of making good the disturbed surfaces (if any) matching with the existing surface is deemed to be included in the unit quoted rates.
All as per item No 107 here-in-before but for 5/6 Amp socket point on independent board complete all as specified and as directed
All as per item No 107 here-in-before but for 5/6 Amp socket point on same board complete all as specified and as directed
All as per item No 107 here-in-before but with 2.5 sqmm cable for 15/16 Amp socket point on independent board and 2.5 sqmm soild cable for earth continuity conductor complete all as specified and as directed
S&F switch piano flush type, single pole 5 Amp 230 Volt all as specified and as directed.
S&F ceiling rose ,surface bakelite 65mm x 50mm size with three terminals all as specified and as directed.
S&F decorative box type LED fitting 20 watt 4 feet with Al extruded batten luminaire for 230 volt AC all as directed by EIC.
S&F new generation energy saving & environmental friendly long life versatile pressure die-cast aluminium building security light with high power LED as light source lamp type 25 w with SPD , IP-66 protection with toughened glass including fixing pipe/saddle complete all as specified and as directed.
S&F decorative box type LED fitting 9 watt 2 feet with Al extruded batten luminaire for 230 volt AC all as directed by EIC.
Supply and fixing DB with sheet metal enclouser 240 volts, 04 way single pole & neutral double door for MCB, including cutting chases for DB of required size and making good disturbed surface area and putting blanking plate if required including taking down old unserviceable one complete all as specified and as directed.
S&F MCB, SP, 10 KA,230 V. "c" curve, 06-32 A , ISI marked complete all as specified and directed
S&F MCB, DP, 10 KA,415 V. "c" curve, 06-32 A , ISI marked complete all as specified and directed
M & L for earthing complete with galvanised steel earth plate electrode 600 x 600 x 6 mm thick burried directly in ground (in vertical position ) earth pit not less than 2.25 mtrs below normal ground level with the top edgeof the earth plate not less than 1.5 mtr (B.G.L.) & connected to galvanised iron wire 4 mm dia by means of bolts,nuts,checknuts & washer of galvanised iron including PCC (1:2:4) type B1 precast RCC cover slab with suitable handle made of 6 mm round bar, including necessary excavation & earth work in any type of soil , 20 mm dia med grade galavinised steel tube for watering with one end fixed with cast iron funnel & wire mesh, 15 mm bore light grade galvanised steel tubing up to 7.5 mtr length for drawing earth lead including common salt , charcoal in alternate layers etc. complete all as shown in EP no 3 of SSR Part 1 & testing on complection including taking down old unsv earthing complete all as specified and directed.
S&F Switch Socket combination, 2-in-1, 3 pin, 5/6 Amps flush type complete all as specified and as directed.
M&L for socket outlet 3 pin , 5 Amp flush type universal, 240 volts complete all as specified and as directed.
S&F Switch Socket combination, 5-in-1, 15/16 Amps flush type complete all as specified and as directed.
S&F electronic step regulator (speed regulation in 5 steps) suitable for ceiling fan 1200 / 1400 mm sweep 120 watt complete all as specified and as directed.
S&F SPN, MCB of capacity 32 Amps, 240 volts complete all as specified and directed
Supply & fixing 18 watt LED street light luminaires with highly efficient lighting in & including mounted bracket made out of GI pipe light grade 25-40 mm bore not less than 01 mtr long duly fixed with all fixing arrangement such as clamps , nuts, bolts complete all as specified and directed by Engineer-in-Charge.
Taking down old serviceable/unserviceable ceiling/exhuast fan connecting wire etc and keeping at site for reuse at site after carying out repair woks to building/rewiring complete all as specified and as directed by Engineer-in-Charge (Deposited in store yard MES)
S&F energy efficient , 5 star rated BLDC motor ceiling fan 1200 mm sweep with all accessories and connecting up with and including the ceiling rose with required flexible wire of suitable size with ceiling fan complete all as specified and as directed.
M&L for earthing complete with galvanised steel each plate electrode 600x600x6mm buried directly in ground (in verticle position) earth pit not less than 1.5 mtr (B.G.L) and connected to galvanized iron earth strip 32x6 mm with GI protection pipe upto pole junction box by means of bolts, nuts, check nuits and washer of galvanised iron including PCC (1.24) type B1 procast RCC cover slab with suitable handle made of 6mm round har, including necessary excavation and earth work in any type of soil, 20 mm dia med grade galvanized steel tube for watering with one end fized with cast iron funnel and wire mess, 40mm bore light grade galvanized steel tubing up to 7.5 mtr leggth for drwing earth lead GU wire protection & common salt, charcoal in alternate layers etc. complete all as shown in EP No. 3 of SSR part 1 and testing on completion incl taking down old unsv earthing complete.
Dismantling & taking down aluminium service wire of any size including necessary disconnection from the pole / main switches etc. all as directed complete
Dismantling house service bracket any type from the wall including making good the disturbed surface complete
Supply and laying in trenches or passing through pipe 1100 volts grade armoured heavy duty XLPE insulated electric cable with aluminium conductor of cross sectional area 06 sqmm 2 core complete all as specified and as directed
Supply and laying in trenches clear sand cushioning under cable 8 cm below and 15cm above complete in level all as specified and directedby Engr-in-Charge. Note:- Punned thickness shall be measured.
Supply and laying burnt clay sub class B brick as cable protection all as specified and directed.
S&F GI Pipe 25mm bore light grade fixed for cable protection along with wall all as specified and as directed
Cutting & screwing existing water pipe line mains of 25 mm bore and connection with new pipe line laid including necessary fittings required at site complete all as specified and as directed.
Supply & laying in trenches GI pipe 20mm bore medium grade including fittings complete all as specified and directed.
Supply & laying in trenches GI pipe 25mm bore medium grade including fittings complete all as specified and directed.
Supply and laying in trenches or passing through pipe 1100 volts grade armoured heavy duty XLPE insulated electric cable with aluminium conductor of cross sectional area 10 sqmm 2 core complete all as specified and as directed
All as per item No 138 but size 10 sqmm 4 core complete all as specified and directed.
All as per item No 138 but size 25 sqmm 3.5 core complete all as specified and directed.
Supply & install test point terminal made out of GI strips 32mm x 6mmx 30cm with GI Nuts & bolts mounted on busbar insulators (02 nos) fixed on wall as directed including taking down.
M&L for air termination single pointed aluminium rod 12mm dia and 300 mm long all as specified and as directed including taking down.
M&L aluminium strip 25x3 mm with saddles and fixing screws etc for roof conductors and down conductors above ground complete all as specified and directed including taking down.
M&L for porceiline insulator suitable for fixing earthing strip to the wall/floor etc complete all as specified and directed.
M&L for earthing with copper earth plate electrode 600 x 600 x 3.15 mm thick burried directly in ground (in vertical position) earth pit not less than 2.25 mtr below normal ground level with the top edge of the earth plate not less than 1.5 mtr (B.G.L.) and connected copper strip 20 x 3 mm earth lead by means of bolts, nuts, check nuts, and washer earth strip protected by and including GI pipe 40 mm bore (light grade ) and connected to main test point as directed and including concrete pit using PCC (1:3:6 ) type C-1, precast RCC (1:1:5:3) type A-1 cover slab of size 40x40x5 cm reinforced with 8 mm dia TMT bars @ 100mm c/c both ways with one handle for lifting made out of 8 mm dia TMT bars @ 100mm c/c both ways with one handle for lifting made out of 8 mm dia MS bar embeded in precast cove slab funel with wire mesh 20mm bore galvanised or steel pipe (light grade) for watering in including necessary excavation and earth work in any type of soil complete all as shown on electrical plate No 3 of SSR part -1 complete all as specified and directed. Note:- result of earth resistant should be less than 3 ohm including taking down.
M&L for PCC 1:2:4 type B-1 (20mm graded crushed stone aggregate) as in grouting, finished even and smooth without using extra cement complete all as specified and as directed.
S&F in repair GI tubing of 40 mm bore light grade with all fitting fixed to wall/ceiling/pole or in trench as cable protection all as specified and directed.
M&L only in repair GI tubing of 80 mm bore light grade with all fitting fixed to wall/ceiling pole or in trench as cable protection all as specified and directed.
M&L for boring holes upto 100mm bore in soil under roads/PCC as directed for cable passing through pipes of required size and disposal of soil to a distance not exc 50m (Note:- Connected items like pipes is measured and paid separately under relavant items)
Supply, install, testing & commissioning in repair of approved factory made outdoor cubical type LT feeder pillar Box outdoor type suitable for 3 phase 4 wire 415V,50 Hz, IP-54 of appropriate size as approved by Engr-in-charge totally enclosed weather, dust vermin proof made of angle iron frame 50mm X50mmX6mm with cable entry and exit through bottom with double compression copper stainless steel cable glands and gaskets and 3.15mm thick CRCA (cold rolled cold annealed )MS sheet bend to shape, front & back side operated double door with proper hinge and Key locking and sliding bolt arrangement on both side with Al bus bar fixed on porcelain insulator and painting panel board complete with two coats of powder coated paint over a coat of red oxide primer with spray painting on internal and external surfaces and shall be complete incld panel internal wiring using with 1.5sqmm FRLSH Cu wire and coloured coded aluminium strips should be used for connecting all MCCBs from busbar either incoming or outgoing, also MCB SPN/TPN should be wired with 16 sqmm FR coloured Al wire . Bus bar shall be insulated with colour code/sleeves/tapes including necessary PCC (1:3:6)type C2 for foundation /Platform all as specified and directed. LT panel board shall be complete in all respects with and incld the following mentioned incoming/outgoing accessories: Note: All MCCB with adjustable protection for over load and short circuit and conforming to IEC60947-II/IS 13947-II (Latest Version). The MCCB should have Ics=100%Icu. The MCCBs shall have spreader links and barriers as standard feature of manufacturer. All out going feeder shall be connected by cable through suitable size gland plate / glands. The various feeders shall be indicated by font size not less than 20 mm letters using Acrylic sheet. The minimums clearance of bus bar shall be 32mm phase –phase and 26mm for phase to earth. The bus bar shall have colour coding with insulating tape. The platform shall be such that it is of a height 45 cm above the nearest road level.
S & F in repair 5 KW ,three phase automatic Street Light timer switch for automatic switching on/off street light based on lux level of nature light, consisting of sensor overload protection fuse gear, power contactor & MCB of suitable capacity, terminal blocks for cable entry & control unit enclosed in pole/Wall mountable elcosure made out of rust proof, shock proof, termite proof FR grade SMC, conforming to IP 66 with universal lock and key arrangement complete all as specified and as directed by Engr- in- Charge Make: kakatiya energy system Pvt Ltd Cat No. Swadeep 66-02EC-5KW 3P or equivalent in Havells/GE/Legrand/C&S/L&T
M&L for water proof, 3core PVC insulated and PVC sheathed, copper conductor cable of size 1.5 sqmm, 1100 Volts grade for electrical connection of street light fittings,complete all as directed.
Supply and fixing cable junstion box "dust proof, acid resistant, shock proof, fire retardent self extinguisher" for outside installation with knockout entry for cable of size 04 - 10 sqmm and 130x180x77mm with terminals, brackets for street light pole mounting including one 6A MCB SP all as specified and as directed.
Taking down overhead LT ACSR conductor from directed location, making rolls and submit to MES store or as credit all as specified and directed by Emgr-in-charge.
Taking down MS clamps/channel/angles for pole incl any insulator from directed location and submit to MES store or as credit all as specified and directed by Emgr-in-charge.
Taking down old u/s service wire of any size from directed location and submit to MES store or as credit all as specified and directed by Emgr-in-charge.
Supply & fixing gun metal gate valve iron wheel head screwed both ends for iron pipes of size 20mm all as specified.
SRI SURAJIT SENGUPTA
M/s. STRUCTURES INDIA
M/S Bikash Saha
SHRI JIBANDHAN PAUL
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .