Engine Division, Koraput
HINDUSTAN AERONAUTICS LIMITED Engine Division, Koraput, Sunabeda- 763002
SUPPLY, INSTALLATION OF FIRE PROTECTION SYSTEM,DG SET,APFC PANEL,UPS ,HEAT PUMP,3WAY RMU PANEL,CCTV CAMERA,LANWAN /INTERNET,EPABX SYSTEM,LIGHTING CONTROL AT LIAISON OFFICE CUM GUEST HOUSE, VISAKHAPATNAM
23922
HAL/KPT/ED/E-PROC/WC-1231/1
IMM
Mig Complex- Engine Divn
₹0
₹3.5 L
29 Dec 2025
13 Dec 2025
13 Dec 2025
29 Dec 2025
FIRE PUMP ROOM EQUIPMENT
(A) Supplying, installation, testing and commissioning of Electric driven Main Fire Pump suitable for automatic operation and consisting of following, complete in all respects, as required: (B) Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520. (C) Suitable HP Squirrel cage induction motor, TEFC, synchronous speed 1500 RPM, suitable for operation on 415 volts, 3 phase 50 Hz, AC supply with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-325. (D) M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. (E) Suitable cement concrete foundation duly plastered with anti vibration pads.
2280 lpm at 70 m Head
(A) Supplying, installation, testing and commissioning of diesel engine driven main fire pump suitable for automatic operation and consisting of following, complete in all respects, as required: (Diesel Driven Pump) (B) Horizontal type, multistage, centrifugal pump of cast of iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520. (C) Suitable HP, 1500 RPM water cooled with radiator, diesel engine conforming to relevant IS standard complete with auto starting mechanism, 12 /24 volts electric starting equipment, diesel tank, exhaust pipe extended upto 10 m outside pump house duly insulated with 50 mm thick glass wool with 1.0 mm thick aluminium sheet cladding, residential silencer, instruments and protection as per standard specification, stop solenoid for auto stop in the event of fault with audio indications, painted with post office red colour etc. as required. (D) M.S fabricated, common base plate, coupling, coupling guard, foundation bolts etc. as required. (E) Suitable cement concrete foundation duly plastered and with anti vibration pads.
2280 lpm at 88 m Head
(A) Supplying, installation, testing and commissioning of electric driven pressurisation pump suitable for automatic operation and consisting of following, complete in all respects, as required: (Jockey Pump) (B) Horizontal type, multistage, centrifugal pump of cast iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS: 1520. (C) Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase 50 Hz AC supply with IP 55 class of protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS: 325. (D) M.S.fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. (E) Suitable cement concrete foundation duly plastered and with anti vibration pads.
180 lpm at 70 m Head
Control Panel for Fire pumps(CPRI Approved).
Fabrication, supply, Insallation testing & commissioning of Electrical control panel of cubical construction, floor mounted type, fabricated out of 2mm thick CRCA sheet, compartmentalised with hinged lockable doors, dust and vermin proof, powder coated of approved shade after 7 tank treatment process, cable alley, inter-connection with suitable size copper conductor cable/solid copper strip, having switchgears and accessories, mountings and internal wiring, earth terminals, numbering etc. complete in all respect, suitable for main fire pump, pressurisation pump & diesel pump set complete as per CPWD specification with following in coming and Outgoings, suitable for operation on 415V, 3 phase, 50Hz Ac Supply with enclosure protection class IP 42 as required:
1100 Volt GRADE POWER /CONTROL CABLES
Supplying, laying, testing & commissioning of FRLS,PVC outer sheateh, steel armoured, aluminium / copper conductor, 1100v grade power cables with glands etc.The cables shall be laid in tray / Hume pipe / in trenches/on walls/ floor etc. as required. For cables laid out door the rate shall include earth excavation providing brick and sand protection, refilling and compacting the earth.The rate shall excludes tray & Hume pipes.The minimum size of the cables shall as mentioned below,
12 C x 2.5 Sqmm.Diesel engines
2 C x 2.5 Sqmm.for Instrumentation
3Cx 2.5 Sqmm.for Instrumentation
12 C x 2.5 Sqmm. Termination
2 C x 2.5 Sqmm. Termination
3 C x 2.5 Sqmm. Termination
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
3½ X 240 sq. mm (62mm)
4 X 16 sq. mm (28mm)
Earthing
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
MS PIPE
Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required:
200 mm dia (wall thickness 6.3 mm)
250 mm dia (wall thickness 6.3 mm)
PIPE FITTINGS
Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, Gl bolts, nuts, washers etc.as required:
80 mm dia
150 mm dia
200 mm dia
Supplying, fixing, testing and commissioning of following size valves, gauges and strainers for condenser water circulation as per specifications.
BUTTERFLY VALVE (MANUAL) with C I body SS disc nitrile sheet & O-ring & PN 16 pressure rating as specified.
200 mm dia
150mm dia.
80mm dia.
Providing, installation, testing and commissioning of stainless steel Y-strainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with stainless steel flange.
100 mm dia
250 mm dia
Supplying, fixing, testing & commissioning of double flanged sluice valve of rating PN 1.6 with non rising spindle, bronze/gun metal seat, ISI marked complete with nuts, bolts, washers, gaskets and conforming to IS 780 of following sizes as required:
100 mm dia
200 mm dia
250 mm dia
Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete
15 mm nominal bore
25 mm nominal bore
Supply, Installation of Flow metre (Electronic type) on Discharge line to measure 150 % of pump flow and suitable to 200 mm dia.
Providing & fixing of pressure switch in M.S. pipe line including connection etc. as required.
Supply and installation of Pressure gauges of suitable range (16 bar pressure) for pumpsets with Ball valves, siphon, Fittings like unions /colors / reducers etc.
Supplying, fixing, erecting, testing & commissioning Diaphram operated vertical Air cushion tank of capacity 500 Ltrs. fabricated out of 8 mm thick MS plate, vessel should be suitable to operate at a maximum pressure of 15 Kg/Sqm and should be complete with necessary inlet & outlet connections for water, air & control
Exhuast pipe for Diesel engine of 150 mm dia M.S. Medium grade with mineral wool insulation with aluminum sheet.
150mm dia M.S. Medium grade shall be laid above ground with structuralsteel supports.
Supplying, installing, testing and commissioning of Expansion Bellow (PN 16) with required flanges, nuts, bolts and gaskets etc. complete.
200 mm nominal dia
150 mm nominal dia
80 mm nominal dia
Hydrant System
Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required:
Supplying, fixing, testing and commissioning of following valves, strainers, gauges in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications.
BUTTERFLY VALVE (MANUAL) with C I body SS Disc, Nitrile Rubber Seal & O- Ring PN 16 pressure rating for chilled water/hot water circulation as specified
150mm dia.
Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required :
Single headed Gunmetal
Single headed Stainless steel
Supplying, erecting and commissioning of Landing Hydrants comprising of the following in the Fire duct.
Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc.conforming to IS 636 (type-A) as required :
Gun Metal
Supplying and fixingHose reel drum of swinging type with 19mm dia Rubber braided hose of 36.5M. length with Gate valve ( upstream) and Shut off nozzle Wih 25mmdia Ballvalve, complete set.
Supplying and fixing Fire duct Shutter fabricated out of M.S.sheet and frame, door shall be 900mm x 1200 mm min. & fixed with 4 mm thick Glass, suitable Rubber beedibg and Locking arrangement. Quoted rate shall be includes all fasteners etc, and complete shutter shall be powder coated of approved colour both inside and out side.
Supplying and fixing M.S. Hose cabinet stand mouted type fabricated out of M.S. sheet of 16 swg. with glass fronted ( 4mm thick glass with rubber beeding) door and size of the cabinet shall be 600mm x 750 mm x 250 mm Quoted rate shall be includes suitable stand for mounting, all fasteners etc, and cabinet shall be powder coated of approved colour both inside and out side.
Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required:
2 way-100 mm dia M.S. Pipe
4 way - 150 mm dia M.S. Pipe
FIRE EXTINGUISHERS
Supplying, installing and commissioning Portable Fire extinguishers of following type & capacity.
C02 type fire extinguisher of 4.5 Kgs. Capacity, with initial filling in brand new cylinder with powder coated finish, fitted with Gun metal union, high pressure stored pressuer, discharge hose, wall mounting bracket etc. complete, confirming to IS:15683. (for electrical room)
ABC powder type fire extinguisher of 6 Kgs. Capacity, with initial filling in brand new cylinder with powder coated finish, fitted with Gun metal union, high pressure CO2 gas cartridge, discharge hose, wall mounting bracket etc. complete, confirming to IS:15683. (car parking area,Corridor & utility)
Mechanical foam type fire extinguisher of 9 liters . Capacity, with initial filling in brand new cylinder with powder coated finish, fitted with Gun metal union, high pressure CO2 gas cartridge, discharge hose, wall mounting bracket etc. complete, confirming to IS:15683. (for trafo yard, DG room, pump room) +wall mounting bracket etc. complete, confirming to IS:15683.(DG room & Trafo yard)
SIGNAGES
Providing and installing in position the following type of sign boards made out of 3mm thick "Opaque" PVC foam board with computer cut, PVC non-reflective self adhesive vinyle painted foam board, complete with mirror fasteners.
Signage with printed "IN CASE OF FIRE, USE STAIRS UNLESS INSTRUCTED OTHERWISE" of 1.5cm height letters in red with white back ground.The size of the board shall be 25cm x 30 cm and shall be fixed at the height of 2 mts. from finished floor near Manual call points.
Floor indentification signage (ie, GROUND FLOOR …etc.) at each stair enclosure on every floor, indicating the floor number in words, lettering size shall be 7.5 cm with contrasting colour from back ground.Size shall be 15cm x 60cm.
Providing and fixing in position the signages " FIRE ORDER" it should contain the following matter on 3mm thick "Opaque" PVC foam board of computerised cut, PVC non-reflective self adhesive vinyle painted foam board of 3' x 4'.
A) ALERT THE SECURITY AT SECURITY ROOM BY ACTUATING MANUAL CALL POINT LOCATED AT STRATEGIC LOCATIONS.
B) EVACUATE THE OCCUPANTS BY USING FIRE EXITS AND EMERGENCY EXITS ONLY AND ASSEMBLE AT VARIOUS ASSEMBLY POITS.
C) IF POSSIBLE TRY TO EXTINGUISH THE FIRE BY USING NEAREST / SUITABLE PORTABLE EXTINGUISHER OR WATER FROM NEAREST WET RISER.
D) BE CALM AND DO NOT GIVE ANY ROOM FROM PANIC, WALK, DO NOT RUN.
E) IF YOU ENCOUNTER SERIOUS DIFFICULTY IN EVACUATION, FLAT AND TRY TO ATTRACT ATTENTION OF RESCUE TEAM.
ACTION BY SECURITY/RECEPTION UPON RECEIPT OF INFORMATION THROUGH FIRE ALARM ORFIRE DETECTORS OR BY USING PUBLIC ADDRESS SYSTEM.
A) ALERT THE OCCUPANTS BY USING PUBLIC ADDRESS SYSTEM. B) INFORM FIRE CONTROL THROUGH ANY ONE OF THE FOLLOWING PHONE NUMBERS: 101 / 2251780 / 2251781 / 2251782. C) REFER EVACUATION PLAN FROM EVACUATING STANDARD PEOPLE. D) GUIDE THE FIRE FORCE, ON THEIR ARRIVAL TO THE SEAT OF FIRE. E) IN CASE OF THE CASUALTIES, CALL AMBULANCE BY DIALLING NUMBER…….. FIRE FIGHTING AGNECY ----------- PHONE : ----------------------- FAX : ----------------------------
ANALOGUE ADDRESSABLE FIRE ALARM SYSTEM
Two Loop Panel.
Supplying, installation, testing & commissioning of repeater panel with 320 character/ Touch screen LCD display with inbuilt reset, acknowledge and silence switches complete as required.
Supplying, installation, testing & commissioning of intelligent analog addressable photothermal detector complete withmounting base complete as required.
Supplying, installation, testing & commissioning of response indicator on surface/recessed MS Box having two LED,metallic cover complete with all connections etc as required.
Supplying, installation, testing & commissioning of intelligent addressable thermal detector with rate of rise cum fixedtemperature thermistor complete with base as required
Supplying, installation, testing & commissioning of fault isolator complete with base as required.
Supplying, installation, testing & commissioning of addressable fire control module complete as required.
Supplying, installation, testing & commissioning Analogue Addressable Monitor module for monitoring the field devices & shall be capable of providing DPDTcontact rated at 24v DC, 2A.( For Flow Switch)
Supplying, installation, testing & commissioning of addressable horn cum strobe complete as required
Supplying, installation, testing & commissioning of .addressable manual call point complete as required.
Supplying and drawing of cable Fire Retardant PVC insulated copper conductor cable in the existing surface /recessed steel conduit of following pairs, cores and size including connections and interconnections etc. as required.
speaker cable Four pair, 2-core, 1.5 sqmm
Supplying and fixing 25 mm dia MS flexible pipe with PVC coating along with all ancillaries and accessories like coupler etc. as required.CONDUITING AND WIRING
Supplying and installing following size of perforatedHot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforationnot more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with two numbers GI Suspenders i/c base of suitable size GIangle, GI bolts & nuts, fastner etc as required
300 mm width X 62.5 mm depth X 2.0 mm thickness
Supplying, installing, testing and commissioning 6W wall mounted type speakers with talk back facility (PUSH TO TALK), in CRCA sheet fabricated housing, complete.
2 WAY TALK BACK SYSTEM
Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required:
25 mm dia
32 mm dia
40 mm dia
50 mm dia
65 mm dia
100 mm dia
150 mm dia
Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required :
50mm dia
Supplying, fixing, testing and commissioning of BUTTERFLY VALVE (MANUAL) with C I body SS disc nitrile sheet & O - ring & PN 16 pressure rating as specified
80mm dia.
Providing, fixing, testing & commissioning of 15mm dia quartzoid bulb type sprinklers of rating 68 degree C with required accessories :
Pendent Sprinkler
Horizontal side wall sprinkler
Providing & fixing flow switch in following sizes M.S pipe including connection etc as required.pipe including connection etc as required..
100mm dia
Supplying, installing, testing and commissioning of Sight glass of 50 mm dia with complete set Bronze both side ball valve along with union and necessary fittings for fixing.
Supplying, Installation, Testing & Commissioning of ‘Silent Type Diesel Generating set as per CPCB IV + or better norms along with having Prime Power Rating of 250KVA , 415 volts at 1500 RPM, 0.8 lagging or better norms along with having Prime Power Rating of KVA as below, 415 volts at 1500 RPM, 0.8 lagging power factor at 415 V suitable for 50 Hz, 3 phase system & for 0.85 Load Factor, including testing at factory and site with fuel, load for test and other necessary arrangements Complete as per scope of work.
Supply, Installation, testing and commissioning of Automatic Power Factor Correction (APFC) panel,indoor type floor mounted free standing totally enclosed, extendable, IP 42, of following capacity for 3 phase, 415 V + 10 %, 50 Hz AC System for Ambient temperature -5°C to +40°C and other necessary arrangements Complete as per scope of work.
Supplying, installation, Testing & Commissioning of following capacity at full load (Unity Power Factor) at operating temperature 0 to 40 0C, Relative humidity 0 to 95%, Online double conversion true sine wave Uninterrupted hot swapable (allow for the replacement or addition of battery modules without shutting down the entire system) modular Power Supply (UPS) system with N+1 modules (N denotes total number of modules required for rated capacity) and other necessary arrangements Complete as per scope of work.
Supplying, installation , testing & commissioning of Heat pumps system for hot water using heat energy source from ambient air to Hot water, of High efficiency and energy saving operation, capable of heating water at 55⁰ to 60⁰ C with silent operation (the sound level should not exceed 65 dB) and other necessary arrangements Complete as per scope of work.
Supply, commissioning & Prove out of one no manually and motorized operated VCB, Shunt trip Vacuum Circuit Breaker of rating 11 KV, 630A, 21 KA for 3 sec with integrated Earthing and CB disconnect switch of Extensible type 3-way Ring Main Unit (RMU) panel as per scope of work.
Supplying Installation Testing and Commissioning of4MP IP IR Dome Camera having following specifications and features etc :- 1) Signal System: PAL/NTSC, Signal to Noise Ratio: >50 dB,Camera should display Camera title, Date &Time in live & recorded video 2)Image Sensor: 1/2.8" or better progressive ScanCMOS to get color image even at night condition(Minimum Illumination: 0.006 Lux@ F1.4,AGC ON, 0 lux with IR or better) True Day & Night High Performance Mechanical IR cut filter with autoswitch, Integrated IR Source (Auto, Manual)- Inbuilt IR LED's with effective distance upto 50 meter or better and 30 meter for colour view in night, Imaging: 1/3s to1/30000s electronic shutter support, Auto Gain Control , White Balance- Auto, Back Light Compensation,Multi zone Privacy Masking, HLC, Digital Watermarking 3) Compression (Minimum): Video:- H.265 or better,Audio:- G.711U/A, G.711Mu, G.726, AAC, G.723 4) Wide Dynamic Range:- WDR (120dB or more) 5) Digital Noise Reduction:- DNR (3D) On/Off 6) Video Streaming & Frame Rates :- Triple streaming, Sub streams minimum: 720P@25/30 fps 7) Image Setting: Rotate Mode, saturation, brightness, contrast, sharpness adjustable through client software or web browser, Edge Analytics: Tripwire, Intrusion,Motion Detection 8) Cyber Security: AES 256-bit Encryption,Configuration encryption, trusted execution, Digest,security logs, account lockout, video encryption,IP/MAC filtering, HTTPS, trusted upgrade 9) Onboard Storage: Camera should support built-in Micro SD/ SDHC/ SDXC Card slot upto 512 GB. Itshould be supplied with minimum 128GB memoryCard. 10) Recording Management: Format SD, overwrite,storage management, video to NAS device, 11) Alarm Trigger : Motion/tampering detection;network disconnection detection; IP conflict detection;memory card state detection; memory space detection 12)Network Protocol: SFTP, IPv6, IPv4, DNS,RTCP,NTP, RTP, HTTP, HTTPS, SNMP TCP/IP, PPPoE,NFS, UDP, ICMP, SSL, DHCP, SMTP, RTSPS,unicast, 13) System Capability: ONVIF, Camera shall support open source VMS 14) Ethernet: 1 RJ 45 10/100 Ethernet port 15) Audio : It should support 1 x Built-In Mic and 1/1 Alarm In/ Out for External Mic. and Speakers as perm site requirement. 16) Power Input: The camera should support simultaneous dual power input—12 VDC (via power adapter) and PoE (802.3af)—to ensure continuous operation in the event of a failure in one power source. 17) Power Requirement: 12VDC/24 VDC/PoE (802.3af)/ePoE 18) Housing/ Enclosure:- IP67 weather proof, IK10,Metallic body 19) Operating Condition:- Ambient Temperature:- (-)05°C to 50°C, humidity 95% (max) (non-condensing) 20) IR life: 40000 hours or higher 21) Video Bit rate: 32 KBPS - 8 MBPS or better 22) Standards: BIS with ER, STQC Certified, CE, FCC and RoHS
4MP @ 25/30fps@1440P (2560x1440) Dome Camera with 2.7 to 4 mm ~12 to 13.5mm or better Varifocal Motorized lens.
Supplying Installation Testing and Commissioning of PTZ (Pan,Tilt and Zoom) IP IR Camera having following spcifications and features etc :- PTZ (Pan,Tilt and Zoom) IP IR Camera having following spcifications and features etc :- 1) IP IR PTZ Camera: Motorized PAN TILT ZOOM with IR 2) Image Sensor: 1/2.8" or better progressive Scan CMOS 3)Signal System: PAL/NTSC 4) Minimum Illumination: 0.008 Lux@ F1.6, AGC ON,,0 lux with IR, or better 5) Imaging: 1/1s to 1/30000s, Auto Gain Control ,White Balance- Auto, Back Light Compensation,Image Rotation, Multi zone Privacy Masking (Upto 24Area), HLC, Defog, Region Of Interest and EIS features. 6) On Screen Display: Camera should display Camera title, Date & Time in live & recorded video both. 7) Signal to Noise Ratio: > 50 dB 8) Event Notification: Through Relays, E-Mails or FTP 9) Day & Night: True Day & Night High Performance Mechanical IR cut filter with auto switch, IR Source-Inbuilt IR LED's with effective distance. The camera should have IR LED’s and cover distance up to 300 meter or above 10) Auto Tracking: The camera should be equipped with Deep-learning-based auto tracking function using simultaneously all of the panning, tilting and zooming should be available. When a motion is detected in a registered monitoring area, the camera should track the motion (object) and capture it. 11) Pre/Post Event Buffering: The camera should support atleast of 5 seconds of pre & post event buffering. 12) Presets: 300 Presets 13) Video Compression (Minimum): H.265 or better,H.264, Audio:- G.711U/A, G.711Mu, G.726, AAC,G.723 14) Wide Dynamic Range: WDR (120dB or more),HLC & BLC 15) Digital Noise Reduction: DNR (2D+3D) On/Off 16) Image Setting: Rotate Mode, ROI ,EIS, Defog,saturation, brightness, contrast, sharpness adjustable through client software or web browser 17) Profile Management: User configuration import,export 18) Cyber Security: Configuration encryption, AES 256-bit Encryption, Digest, account lockout, video encryption, IP/MAC filtering, trusted boot, trusted upgrade, trusted execution 19) Onboard Storage: Camera should support built in Micro SD/SDHC/SDXC Card slot upto 512 GB . It should be supplied with minimum 128GB Memory. 20) Recording Management: Format SD, overwrite, storage management, video to NAS device, remote archive access via FTP login 21) Edge based Video Analytics & Alarm Trigger: Motion/tampering detection; network disconnection detection; IP conflict detection; memory card state detection; memory space detection, Tripwire, Intrusion, Object Abandon/ Missing, SMD, Face Detection 22) Network Protocol: SFTP, IPv6, IPv4, DNS,NTP, HTTP, HTTPS, SNMP, TCP/IP, PPPoE, NFS, ICMP, DHCP, SMTP, RTSPS.23) System Capability: ONVIF Profile S, G & T. CCTV Camera OEM should be fulltime member of ONVIF and quoted models should be listed on ONVIF official website (All the certifications & Credentials should be valid on the date of technical evaluation). 24) VMS: Camera shall support open source VMS 25) Connectivity: 1x LAN RJ-45 (10/100Base-T) 26) Audio Support: Audio Interface : The camera should have 1/1 Audio In/Out to connect External Mic and Speaker Audio Compression : PCM, G.711U/A, G.711MU, G.726, MPEG2-Layer2, G.722.1 27) Alarm In/Out : Alarm In/out- 7/2 Ch In/Out 28) Power Input: The camera should support simultaneous dual power input—DC/ AC (via power adapter) and PoE (802.3af)—to ensure continuous operation in the event of a failure in one power source. 29) Power Requirement: 24 VDC, 2.5 A (± 25%), PoE+ (802.3at) 30) Enclosure & Weather Proof Standard: IP67 weather proof and IK10, TVS 8000V lightning proof, surge protection, voltage transient protection 31) Operating Condition:- Ambient Temperature:- (-)05°C to 50°C, humidity 95% (max) (non-condensing) 32) IR life: 40000 hours or higher 33) Video Bit rate: 32 KBPS - 8 MBPS or better 34) Standards: BIS with ER, STQC Certified, CE, FCC and RoHS
4 MP IP IR motorized PTZ (4MP @25/30fps or better) camera, Triple streaming , configurable on resolution Main stream: 4MP@25/30 fps Sub streams :1080p@25/30 fps & D1@25/30 fps or better, varifocal lens 4.5-135mm or better with Automatic & manual Focus Adjustment provisions, 30x Optical zoom and 12x Digital zoom with angle of viewH : 57˚–2.4˚, m,PAN Travel: Pan: 0° ~ 360° endless;Manual Pan: 300°/s, Preset : 300° /s, Tilt Travel: Tilt: 0-90°, auto flip 180°, Manual Tilt: 200° /s, Preset : 300° /s
64 Channel Network Video Recorder (NVR) having display split :- Main screen: 1/4/8/9/16/25/36/64, 2nd screen: 1/4/8/9/16
Supplying, installation, Testing and commissioning of following capacity 8 port Layer 2 indoor Network Switch having features and specifications etc. asmentioned here under: Minimum 8 X RJ-45 GigabitEthernet Ports and additional 2 X 1G SFP Ports with non-blocking architecture by having Switching capacity of minimum 20Gbps and packet forwarding rate of 14Mpps or higher, 8K MAC table. Internal dual AC Power supply with operating temperature of -5 0C to +50 0C. Jumbo frame: 10KB or higher, IGMP Snooping, IGMP snooping querier and support for IGMP Snooping Fast Leave, Should create 250 or more MLD groups, MLD Snooping, Per VLAN MLD Snooping C MLD Snooping Fast Leave, STP, RSTP,MSTP, Loopback detection, Multicast filtering, VLAN Tagging, ǪOS: 8 Ǫue per port, WRR, IPv4/IPv6 Interface : minimum 100 IPv4 static route entries and minimum 50 IPv6 static route entries, 700 Acess Control entries, SSH CSSL for IPv4 and IPv6, 802.1x, ARP Spoofing, DHCP Snooping and server screening, IP+MAC+Port Binding, Per Port Bandwidth Control, 802.1X Authentication (Supports local/RADIUS database, Port-based Access Control and EAP, OTP,TLS, TTLS, PEAP Support) Cable Diagnostic feature,LLDP, LLDP-MED, SNTP/NTP, RMON, SNMP v1,v2c,v3 and SNMP Traps. Certifications: UL, CE, FCC, RoHS, MTCTE, OEM/Product must be on Trusted Telecom Portal of Department of Telecommunication, Government of India etc. complete as required
8 port PoE Layer 2 Network Switch with PoE Support of 130W or higher with each copper port supporting 802.3at PoE+.
Supplying, installation, Testing and commissioning of following capacity 24 port Layer 3 Network Switch having features and specifications etc. as mentioned here under: At least 20 X RJ-45 Gigabit Ethernet Ports and additional 4 combo 10/100/1000 base-t/SFP Ports with additional 4 SFP+ ports non-blocking architecture by having Switching capacity of min. 128Gbps and packet forwarding rate of 95Mpps or higher, 16K MAC table. Console Port, USB port, Internal AC Power supply with operating temperature of 0 to +50 0C.Stacking port with stacking support of minimum 8 units per stack. 48K Mac address, 9K or more Jumbo frame, ERPS with enabling ring to converge in less than 50 ms from node or link failure, Static routing, Static, 6to4, ISATAP and GRE, IPv6 Neighbor Discovery (ND), BGP, ISIS, MPLS, VRRP v2, OSPFv2/v3, PBR, Route Redistribution, RIPv1/v2/ng, IP Helper all L3 Protocols should support from day 1 for both IPv6 and IPv4, 802.1x, Port security , Radius C TACACS+ authentication C accounting, DAD, DAI, DoS attack prevention, SSH, Guest VLAN, IP Access List, MAC Access List. Multicast: VLAN, PIM-SM, PIMDM,PIM- SDM, PIM-SMv6, DVMRP v3 and MSDP,IGMP C MLD Snooping, Flow mirroring, IGMP C MLD Snooping Ǫuerier, Per-VLAN IGMP C MLD Snooping.SNMP, Dual configurations, Multiple images, RMON,LLDP/LLDP-MED, sFlow, DHCP/BOOTP Client,IPv4/IPv6, Syslog server, Debug command, 802.3ah Ethernet Link OAM, 802.1ag Connectivity Fault,Y.1731 OAM, 802.1Ǫbb Priority- based Flow Control (PFC), Dying Gasp, Cable Diagnostics , 6 kV surge protection on all Gigabit Ethernet ports and on all GE RJ-45 access ports. certifications: UL, CE, FCC, RoHS, MTCTE, OEM/Product must be on Trusted Telecom Portal of Department of Telecommunication, Government of India etc. complete as required
Supplying, drawing, Installation, Testing and commissioning of CAT6 UTP LSZH 23AWG Twisted Pair Cable in existing conduit/ on surface, Category 6 Unshielded Twisted Pair, 4 pair should be complied as per UL/ETL verification program for compliance with ANSI/TIA-568.2-D standard. Outer diameter should be in the range of 6.1mm nominal with Operating Temperature Range : -5° to +60°C, Bending Radius : < 4 X Cable Diameter at –5°C ± 1°C and Pulling Force : 11.5Kg etc. complete as required
1 Run of cable
Supplying, drawing, Testing and commissioning of Cat6A UTP 4 pair, 23 AWG solid copper cable in existing conduit/ on surface, U/FTP, LSZH, Non Plenum, Horizontal (solid) Cable suitable for high speed data networking application supporting upto 10Gbps over a 100 meter channel. The 4 Unshielded Twisted Pairs (UTP) cable with color coded insulation for easy indentification should have FLAME PROPERTIES i.e. Flammability Test - IEC 60332-1, Smoke Density - IEC 61034, LSZH standards compliance: ANSI/TIA-568 C.2, ISO/IEC 11801, IEEE 802.3an, RoHS. Delay Skew should be < 45NS. The outer Cable Diameter should be 7.5 + 2 mm. Cable should have been tested and verified by UL/ ETL etc. complete as required.
4 Run of cable
Supplying, Installation, Testing and commissioning of RJ45 Connector for CAT 6/6A Cables. RJ45 modular plug supports 4 twisted pairs, 8 positions, 8 connectors. Housing: PC, UL94V-2, transparent color, Use for 24- 26 AWG stranded wires etc. complete as required.
Supplying and fixing of following size Wall Mount Rack having Fixed Structure with 0.8mm CRCA Sheet, completely knocked-down condition (CKD) Shape, Vertical Mounting Rail 1.6 mm with 'U'Marking, Minimum 2 cable entry/exit provision at Top and bottom with rubber protection, Front 5mm Toughened Glass with lock, wall mounting kit, Powder coated Color- RAL- 7035, complied with UL & RoHS, 2 x 6 sockets 16A power distribution units, 3 numbers closed cable organizer, Hardware mounting screws packet of 20 x 1 number, etc. complete as required
9U Rack
15U Rack
Supplying and drawing following core Multi mode Fiber Optic Cable having corrugated steel armoring, leser optimize 50/125 µm with HDPE jacket, LSZH (Low smoke Zero Halogen), Tight-buffered or loose tube, maximum attenuation: < 3.5 dB/km at 850 nm, < 1.5 dB/km at 1300 nm, bandwidth > 2000 MHz-km at 850 nm, > 500 MHz-km at 1300 nm compliance and certifications: ISO/IEC 11801 Ed. 2.2, ANSI/TIA-568-C.3, ITU-T G.651.1 RoHS compliant. Multi Mode Fibershall be Central-loose tube filled with Thixotropic jelly, duly following Standards: ISO 11801, IEC 60793-1/60794-1-2, ITU-T-REC G.652D and Telecordia GR 20-core, High quality Electro Chromium Coated Corrugated Steel tape (ECCS ) and HDPE- Sheath,Operating ambient Temperature should be – 5 0C to +50 0C and Storage Temperature should be – 5 0C to +50 0C, Maximum Attenuation ± 3.5 dB/km at Operational Wavelength 850 nm and ± 1.5 dB / km at Operational Wavelength 1300 nm . type of fiber should be 50/125 / G.652D & Refractive Index should be 1.483/1.478, The value for Mode-filed,Cladding Diameter 50 ± 2.5 µm and 125 ± 1µm correspondingly i/c splicing & marking etc complete as required
12 Core Multi Mode Optical Fiber Cable
Supply and fixing following port Rack Mount loaded LIU with pigtail, Front-mounted cable saddles for jumper management, suitable to manage both splices and terminations, Pre-assembled shelves in multiple configurations, Rubber fiber slotted bracket built-in, metal splice shelf to protect the fibers, 2 fiber spools built-in for 900μm tight buffered fiber storing, Capable of storing up to 3 meters of 900μm tight buffered fiber per adapter, Removable front and rear covers for better access to interior of LIU, Should be Single / Multi mode LC Type fully loaded. Accessory kit consists of cable ties, mounting ear screws, and spiral wrap tube etc complete as required.
12Port LIU
Supplying and fixing Patch Cord of Optical Fiber Multi Mode or Single Mode LC to LC Fiber Duplex having high precision ceramic ferrule with good concentricity, Fiber corning single mode G652D, Cable Type 2mm with Mechanical specification Apex Offset < 50 µm, Fiber Height + 100 nm, End-face radius of Curvature 7mm < R < 0.2 db, Working ambient Temperature – 5 0C to +50 0C, Storage Temperature – 10 0C to +50 0C, Length -- 2meter, Type -- LC-LC Duplex etc complete as required
Supplying, Installation, Testing and commissioning of small form-Pluggable (SFP) for Network Switches. Must be hot Pluggable, RoHS Complaint, etc. complete as required
1G SFP Single Mode/Multi Mode
10 G SFP + Single Mode/Multi Mode
Supplying, installation, Testing and commissioning of following capacity 24 port Layer 3 Network Switch having features and specifications etc. as mentioned here under: At least 20 X RJ-45 Gigabit Ethernet Ports and additional 4 combo 10/100/1000 base-t/SFP Ports with additional 4 SFP+ ports non-blocking architecture by having Switching capacity of min. 128Gbps and packet forwarding rate of 95Mpps or higher, 16K MAC table. Console Port, USB port, Internal AC Power supply with operating temperature of 0 to +50 0C. Stacking port with stacking support of minimum 8 units per stack. 48K Mac address, 9K or more Jumboframe, ERPS with enabling ring to converge in less than 50 ms from node or link failure, Static routing, Static, 6to4, ISATAP and GRE, IPv6 Neighbor Discovery (ND), BGP, ISIS, MPLS, VRRP v2, OSPFv2/v3, PBR, Route Redistribution, RIPv1/v2/ng, IP Helper all L3 Protocols should support from day 1 for both IPv6 and IPv4, 802.1x, Port security , Radius C TACACS+ authentication C accounting, DAD, DAI, DoS attack prevention, SSH, Guest VLAN, IP AccessList, MAC Access List. Multicast: VLAN, PIM-SM, PIM DM, PIM- SDM, PIM-SMv6, DVMRP v3 and MSDP, IGMP C MLD Snooping, Flow mirroring, IGMP C MLD Snooping Ǫuerier, Per-VLAN IGMP C MLD Snooping.SNMP, Dual configurations, Multiple images, RMON, LLDP/LLDP-MED, sFlow, DHCP/BOOTP Client, IPv4/IPv6, Syslog server, Debug command, 802.3ah Ethernet Link OAM, 802.1ag Connectivity Fault, Y.1731 OAM, 802.1Ǫbb Priority- based Flow Control(PFC), Dying Gasp, Cable Diagnostics , 6 kV surge protection on all Gigabit Ethernet ports and on all GERJ-45 access ports. Certifications: UL, CE, FCC, RoHS, MTCTE, OEM/Product must be on Trusted Telecom Portal of Department of Telecommunication, Government of India etc. complete as required
Supplying, installation, Testing and commissioning of following capacity 24 port Layer 2 indoor Network Switch having features and specifications etc. as mentioned here under: At least 24 X RJ-45 Gigabit Ethernet Ports and additional 2 X 10G Base -T with 4 X SFP Ports with non-blocking architecture by having Switching capacity of min. 168Gbps and packet forwarding rate of 125Mpps or higher, 16K MAC table. Console Port, USB port, Stacking support of min. 8 units per stack. Internal dual AC Power supply, STP, RSTP, MSTP, BPDU Filter, BPDU Restriction, Min. 9K Jumbo Frame, LBD, IGMP Snooping V1/V2/V3, MLD Snopping V1/V2. IGMP /MLD Groups 1K or more, IPv4/IPv6 Loopback Interface, 16 L3 IP Interface, Ipv6 ND, VRRPv3, UDP Helper, ECMP. VLAN: 802.1Ǫ, Port based, Ǫ-in-Ǫ, Multicast VLAN, Protocol VLAN,VLAN Trunking, DHCP Snopping, Server, server Screening. RADIUS , TACACS+ Authentication, ǪoS: 802.1P, 8 queues per port, ǪoS : WRR, Strict+WRR, WRED, 802.1p. ACL: MAC based, IPv4C IPv6, TCP/UDP Port number, time based ACL, TFTP Client, SNMP V1, v2c, v3, SNMP traps, RMON, DHCP server, relay, client, LLDP, LLDP-MED, OAM, Dying Gasp, 802.3ah, sflow, RIP, OSPF v2/v3, policy based route, SSL, SSH. 6 kV surge protection on all Gigabit Ethernet ports and on all GE RJ-45 access ports. Certifications: UL, CE, FCC, RoHS, MTCTE, OEM/Product must be on Trusted Telecom Portal of Department of Telecommunication, Government of India etc. complete as required
24 port Layer 2 Non-PoE Network Switch
Supplying, Installation, Testing and commissioning of following CAT6A Patch Cord should have ETL/UL verification program certificate for compliance with ANSI/TIA-568.2-D etc. complete as required.
Copper Patch Cords of length 1m (3ft)
Copper Patch Cords of length 3m (10ft)
Supplying, Installation, Testing and commissioning of indoor Wireless Access Point for High density use having features and specifications etc. as mentioned here under- WiFi6 802.11ax 574Mbps (2.4GHz) + 2402Mbps (5GHz), WIFI 6 Certified, 1 x RJ45 console port, MG 2.5G LAN POE Port, factory reset, WPA/WPA2/WPA3™ Personal/Enterprise, WEP 64/128-bit, SSID broadcast disable, MAC address access control, Internal RADIUS server, SNMP, Customizable Captive Portal, Auto Channel, Works as Access Point, WDS, WDS with AP, Wireless Client ., Web (HTTP), Secure Socket Layer (SSL), Traffic control, Support ATF/Fast Roaming/Band Steering, Supports enhanced security – WPA-PSK/WPA2-PSK/WPA3-PSK and RADIUS client, and Cipher negotiation, and MAC/ IP ACL for networks, Certifications: MTCTE, CE, FCC. Works as Standalone, Compatible with S/W & H/W Controller with addtional features like - Real-Time Monitoring and Alerts, Rich Advanced Features, Centralized Device Management, Role-Based Administration, Real-Time Monitoring, VLAN and Access Control, Auto RF Management and Bandwidth Optimization, Multi-SSID and Captive Portal Authentication.OEM/Product must be on Trusted Telecom Portal of Department of Telecommunication, Government of India etc. complete as required
Supplying Installation Testing and Commissioning of 24 port Cat6 Patch Panel loaded. Must be of 1U height with clear label holders and white label with the panel
Supply ,installation of Quad Data Wall Outlet Face Plate with sitable box 4 Port Rj45/Rj11 Ethernet Network Socket for Computers/Tablets & Networking .
Supplying, installation, testing and Commissioning of IP based voice communication system with 04 Port Voicemail, 04 Port FXS, 04 Port FXO, 1 PRI Trunk lines (30 Channels) Circuit with CLIP Facility, min 100 IP users License with provision for further additions, 100 analog users, 01 Number IP based Operator Console, 100 Party Conference, Speed Dial, Music on Hold, Internal/ External ring difference, Call Barring, Call Pickup, Redundant server in active -Active mode and as per technical specification including supporting accessories etc complet e as required. The system should have valid TEC GR approval from DoT.
Supplying, Installation, Testing & Commissioning of Analog phones having standard feautres like 16 digit LCD display, 2 way speaker, caller ID and number storage facility etc. complete as required.
Supplying and drawing 20 Pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC Conduit etc. complete as required
Supplying and drawing following core Multi mode Fiber Optic Cable having corrugated steel armoring, leser optimize 50/125 µm with HDPE jacket, LSZH (Low smoke Zero Halogen), Tight-buffered or loose tube, maximum attenuation: < 3.5 dB/km at 850 nm, < 1.5 dB/km at 1300 nm, bandwidth > 2000 MHz-km at 850 nm, > 500 MHz-km at 1300 nm compliance and certifications: ISO/IEC 11801 Ed. 2.2, ANSI/TIA-568- C.3, ITU-T G.651.1 RoHS compliant. Multi Mode Fiber shall be Central-loose tube filled with Thixotropic jelly, duly following Standards: ISO 11801, IEC 60793- 1/60794-1-2, ITU-T-REC G.652D and Telecordia GR20-core, High quality Electro Chromium Coated Corrugated Steel tape (ECCS ) and HDPE- Sheath, Operating ambient Temperature should be – 5 0C to +50 0C and Storage Temperature should be – 5 0C to +50 0C, Maximum Attenuation ± 3.5 dB/km at Operational Wavelength 850 nm and ± 1.5 dB / km at Operational Wavelength 1300 nm . type of fiber should be 50/125 / G.652D & Refractive Index should be 1.483/1.478, The value for Mode-filed,Cladding Diameter 50 ± 2.5 µm and 125 ± 1µm correspondingly i/c splicing & marking etc complete as required.
6 Core Multi Mode Optical Fiber Cable
12 Core Multi Mode Optical Fiber Cable
Supplying,installation of 1 module with RJ11 telephone socket complete set with box and suitable cover plate
Supplying,installation of telephone distribution box of following type with rating IP44(indoor type) and necessary durable frame (ABS or galvanized iron ) complete set.
200pair crone box
100pair crone box
50pair crone box
Supplying, Installation, Testing and commissioning of Passive Infrared(PIR) technology based occupancy sensor with day light dimming(lighting level shall be regulated as per availability of natural day light in an area along with occupancy detection.) having high performance, regulating programmable type, suitable for connected load upto 10Amp , for mounting height up to 3 mtr and for 5 m diameter coverage area along with necessary fixing arrangements i/c programming at site etc. complete as required.
Supplying Installation, Testing and Commissioning of LED RGB/RGBWW/RG BNW/ RGBA/ RGBW (as per site requirement) Linear Profile / Wall Washer luminaire for Facade lighting with aluminium extruded/ Die Cast housing with inbuilt driver of following wattage as given below. The luminaire bracket shall be made of cold-rolled steel & shall be so designed that the luminaire can be tilted to ±90°, having the rotation degrees scale shall be provided. The luminaire shall be IP66 protection also having silicon gasket between optical cover & LED chamber to ensure proper IP66 protection. CRI>80, SDCM<5, THD<10%. as per IEC 61000-3-2, under voltage, over voltage protection, driver inbuilt surge protection of 4KV and external surge protection (SPD) of 10 KV common mode/differential mode, Driver Efficiency>85%, EMI/ EMC as per CISPR-15. There should be options of beam angles of 10/20/30/40/60, asymmetric degree. Luminaire should have efficacy of minimum 40 lm/W for RGB/RGBNW/RGBWW/TNW and 65 lm/W for mono colour options. Luminaire shall be capable of producing dynamic colour changing light for with 16 million colours by DMX/Ethernet based control. The beam angle of the fitting shall be narrow, medium, wide or asymmetric as per the requirement. Luminaire shall be complete with replaceable driver and capable of operating at line voltage without any separate power supply from 24 V DC. Fixture shall be suitable to operate at an ambient temperature range of - -10°C to +50°C and shall have impact resistance of IK 07. Lifetime of complete luminaire (LED ,Driver ,Electrical & control circuitry) shall be at leastL70:50000 burning hours at 50°C. Luminaire shall beconforming to BIS (IS 10322) with dully R Numbermarked and shall be complete with all necessaryaccessories required for proper working of fixture including connection/inter connection with weather proof ISI Marked copper conductor of minimum size 1.5sqmm connection cables and accessories , Integral male/female water proof connectors of IP68 etc. as required. The successful bidder shall submit the following certifications/reports for approval before supply of materials: product data sheets, LM79 report from NABL accredited lab, illuminance diagram, polar curve & LM80 report issued by LED manufacturer, Rohs Compliance Wattage per meter
Supplying Installation, Testing and Commissioning of LED RGB/RGBWW/ RGBNW/ RGBA/RGBW suitable for exterior use having IP68 rating (as per site requirement). Flexible light strip of 5 mtr standard length with 12-15 Watt per meter. Luminaire shall be capable of producing dynamic colour changing light for with 16 million colours by DMX/Ethernet based control. Minimum System lumens 450 lumens/meter and System Lumen Efficacy > 30lm/w. Luminaire light beam spread - 100-110°, The Strip should have IP 68 protection and is offered IP 68 rated connectors to join the LED Strips in continuity. The luminaire must be offered with Aluminium channel for mounting the strip lights. The product should be complete with all accessories and Driver. Lifetime of complete luminaire (LED, Driver, Electrical & control circuitry) shall be at least L70:50000 burning hours at 50°C. Luminaire shall be conforming to BIS (IS 10322) with dully R Number marked. Luminaire shall be complete with replaceable driver and capable of operating at line voltage without any separate power supply from 24 V DC, Fixture shall be suitable to operate at an ambient temperature range of -10°C to +50°C. The successful bidder shall submit the following certifications/reports for approval before supply of materials: product data sheets, LM79. report from NABL accredited lab, illuminance diagram, polar curve & LM80 report issued by LED manufacturer & RoHS Compliance along with CE certificate.
Supplying Installation, Testing and Commissioning of DMX Controller for the system including address writer and programming the DMX controller with the suitable designs as decided by the Engineer-in-charge/client department ( not less than 10 nos designs) and all other accessories required for the running of the system Controller should have Input Power 5-5.5V DC 0.6A and Output Protocol DMX512 with 4 universe, 2 universe should work in Stand Alone Mode and 2 universe should work in live mode with laptop/ tablet / computer. The universe should be expandable from 2 to 4 DMX512 universes. It should be compatible for Programmability with PC, Mac, Tablet, Smartphone by using USB & Ethernet. Dmx controller should have network controllability feature to control the scene remotely through LAN and triggered via UDP packets on port 2430. It’s must have Connections Type C USB, XLR3, Ethernet, battery. There should be provision for Memory microSD card. Device should have Intuitive backlit keyboard with 10 presents and also have provision of keypad on device for changing scene manually from device. Device should be capable to work on Extended triggering possibilities (TCA) & also have Smart Upgrade Technology (SUT). It is an IP 20 unit and has an Operating Temperature of 0°C to 50°C.OS Requirements for the controller is Mac OS X 10.8-10.12, Windows 7/8/10/11. Standards should be EC, EMC, ROHS. The controller should have a variety of features including 2048 DMX channels, clock/calendar, iPhone/iPad /Android remote control, Ethernet facilities, dry contact port triggering and multi-zone SD card memory. Network synchronization of one area across hundreds ofuniverses with the possibility of 99 scenes across 5 areas with auto clock triggering for sunrise and sunset and as per the festivals for specific occasions. Device should be equipped with meta clamp to mount on wall with data enablers and splitters as required. To be provided with IP 66 enclosure if installed in external environment.
Supplying Installation, Testing and Commissioning of DMX Splitter with Input Voltage range : 190-240V AC, Power Consumption 5W max. Housing is made of CRCA with powder coated finish Mounting, 19 inch rack mountable, Operation Temperature - 30°C to +55°C, 8 Output with 3pin XLR terminal sockets, Ingress Protection Rating IP20. This unit takes the DMX Signal from DMX Controller & split the signal into 8 separate output channels. The output terminals of Splitters are optically isolated from the input. Splitters should be capable to amplify the DMX signal & allowing the data link to be extended by max. 300 m (1044 ft.) using AWG 22 DMX cable or 150 m (500 ft.) using AWG 24 DMX cable or maximum 20-25 fixture per output channel. To be provided with IP enclosure if installed in external environment etc., complete as required.
Supplying, installation, testing and commissioning of high quality DMX decoder, Power Input : DC 24V etc complete as required.
Supplying Installation, Testing and Commissioning of Signal Amplifier to boost the Signal, IP 65 rated module to enhance the depleting DMX Signals, should have IP 66/67 rates inbuilt connectors compatible with Luminaires. It should be offered with inbuilt electronic circuit for functioning. No external LED driver needed etc., complete as required.
Supplying and Fixing of IP65 "I" power connectors having 3/4 pole cable connector, chuck type strain relief, Current rating 20 A rms continuous, Easy and extremely precise locking system "Quick Lock" High impact materials - long-lasting and reliable etc complete as required.
Supplying and Fixing of IP65 "I" DMX connectors having 3/5 pole cable connector, Male/Female connector with improved latch, cage type contacts, "solder stop" for easy soldering, and additional ground contact for best contact integrity between chassis and cable connector. More durable housing for maximum reliability, etc complete as required.
Supplying Installation, Testing and Commissioning of EV charging station As per specifications and in Compliance to relevant IS codes etc
Parkbay DC Charger (Mode-3) Power Level 2: Normal Power ~24KW and above, 3 phase 415VAC(-40% to +20%), Frequency:50 Hz +/-5%, output supply: DC 12/24 Volt, Operational temperature range : -25 to 55 0C (outdoor), -5 to 55 0C (Indoor), RH upto 95%, Charging Device as per Device/protocol: IS-17017-23,EV-EVSE Communication as per IS-17017-24, ISO 15118, Infrastructure Socket as per IS-17017-2-2/3, Vehicle Connector as per IS-17017-2-3 Vehicle Inlet/Connector As per EV manufacturer, suitable for 4 wheelers. Indoor use: at least IP42; Outdoor use: at least IP54. Mechanical Strength: protection of the external enclosure against mechanical impact shall be IK08 according to IEC 62262. O/L,S/C protection. Insulation Resistance > 1 M Ω. Cable Length: 7.5 m. RCD having a rated residual operating current not exceeding 30 mA; Separate RCD for multiple outputs.Telecommunication port of the EV supply equipment according to IS 13252 (Part 1) : 2010. OCPP(Open charge point protocol) 1.6J upgradable to ocpp 2.0. Device Should follow 17017 series of IS codes in general and the installation of the system shall comply with relevant IS Codes
SUB TOTAL
I / We hereby quote percentage above (+) or below (-) the Estimated cost
SUB TOTAL (D)
CESS @1%=[E]
SUB TOTAL [F]=[D]+[E]
GST @18% [G]=[F]*18%
GRAND TOTAL [H]=[F]+[G]
NOTE: 1. Any changes in Tax structure as per GOI shall be applicable and will be reimbursed. 2.It is two Bid system.Do not scan the Price Bid and upload at any other place. 3. The work is on package basis. 4.The Contract will be finalized on Grand Total Amount [H]= [F]+[G] quoted basis. 5. MANDATORY REQUIREMENT: Please mention the firm's name in the relevant column. 6. It is a percentage rate tender. Hence the tenderers are required to quote rates on percentage basis i.e. above or below the estimated cost put to tender. 7. The quoted rates in the bill of quantities are inclusive of all types of taxes, duties levies, fees and charges etc., imposed by Central/ State Govt. and local bodies Compensation Cess, Labour Cess, Custom Duty, royalties and other levies. It shall also include all other costs including loading, un-loading, insurance, transportation, testing and Certification expenses except GST . GST at the prevailing percentage is added in the BOQ at the end.
LIST OF WORK IN PROGRESS
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
raw.json
RAW_JSON
NIRWC1231.pdf
TENDER_DOCUMENT • 1.83 MB
EPSMandateFormat.pdf
TENDER_DOCUMENT • 0.45 MB
FormatTurnoverExp.pdf
TENDER_DOCUMENT • 0.22 MB
BIDSECURINGFORMAT.pdf
TENDER_DOCUMENT • 0.14 MB
GCC2023.pdf
TENDER_DOCUMENT • 2.92 MB
BOQ.pdf
TENDER_DOCUMENT • 0.62 MB
PBWC1231PBF1.xlsm
TENDER_DOCUMENT • 0.04 MB
WC1231WORKINHANDFORMAT.xls
TENDER_DOCUMENT • 0.02 MB
undertakingFormat.pdf
TENDER_DOCUMENT • 0.58 MB
CHECKLIST.pdf
TENDER_DOCUMENT • 0.61 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .