Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.9 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹8.3 L+₹5,040.40 (0.61%)Rejected-Finance 00 LALPUR KICHHA ROAD RUDRAPUR KICHHA RUDRAPUR UDHAM SINGH NAGAR UTTARAKHAND 263148 | UDAM SINGH NAGAR | UTTARAKHAND | 263148 | L2 | Rejected-Finance Not being L1 | |
| 3 | L3₹8.7 L+₹42,992.40 (5.18%)Rejected-Finance 0 NEAR SHIV MANDIR KALYANIPURA KRIPAL NAGAR AJMER RAJASTHAN 305001 | AJMER | RAJASTHAN | 305001 | L3 | Rejected-Finance Not being L1 | |
| 4 | L4₹9.0 L+₹65,220.40 (7.86%)Rejected-Finance H 10 KARNI NAGAR NEW NAGAUR ROAD NEAR MANDORE POLICE STATION 8TH MILL MANDORE JODHPUR 342304 | JODHPUR | JODHPUR | RAJASTHAN | 342304 | L4 | Rejected-Finance Not being L1 | |
| 5 | L5₹9.6 L+₹1.3 L (15.9%)Rejected-Finance | L5 | Rejected-Finance Not being L1 |
Tender Value
Refer Docs
EMD Value
₹16,000
Closing Date
25 Sept 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
AGE I Nagtalao
Military Engineer Services AGE I Nagtalao Pin 900120 CO 56 APO
Repair Maintenance to LT over head conductors UG cables LT Panels and other connected works at Ralawas under AGE I Nagtalao
2020_MES_375409_1
8312/20-21/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
AGE I Nagtalao
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
AGE I Nagtalao
₹16,000
Yes
20 May 2021
7 Sept 2020
26 Sept 2020
7 Sept 2020
25 Sept 2020
13 Sept 2020
60 days
Amount
Dismantling of LT overhead ACSR conductor of any size including separating serviceable conductor and kept in safe custody for reuse in the work and removing unserviceable conductor from site complete all as specified and directed.
S & F aluminum conductor steel reinforced (ACSR) any size on overhead LT electric line with stretching and tensioning the same with reqd span say and binding the conductor with pin/shackle insulator and jumper with aluminum binding wire not less than 2mm dia complete all as specified and directed.
All as per item No 2 above but fixing and restringing of old serviceable (ACSR) conductor obtained from items No 01 here in before including binding complete all as specified and directed.
M&L for Retightening/tensioning the ACSR conductor with maintaining the proper span sag including rebinding the ACSR conductor with pin/shackle insulator & jumper with new aluminum wore not less than 2mm dia complete all as specified and directed
M&L for Dismantling of GI earth wire/guard of any size including separating serviceable wire and kept in safe custody for re-use in the work and removing unserviceable GI wire from site complete all as specified and directed.
S&F galvanized GI wire 4mm dia as in continuous earth wire/guard or cradle wire made to required shape fixed on poles for LT feeder including binding the same with new GI binding wire not less than 2mm dia complete all as specified and directed.
All as per Item No 6 above but fixing only serviceable materials obtained from Item No 5 here-in-before complete all as specified and directed.
Dismantling of cross arms fixed on RCC/Steel tubular poles carefully including separating and getting aside, serviceable cross arms for re-use in the work and removing unserviceable cross arms from site complete all as specified directed.
S & F cross arms made out of mild steel channel or angle section of reqd size and shape including clamp back plate with bolts, nuts and washers drilled for insulator bolts welding bending cold or hot in any shape or size as directed and painted with two coats of aluminium paint over a coat of red oxide primer complete all as specified and directed.
Fixing only old serviceable cross arms obtained from ser Item No 9 here-in-before with providing new bolts, nuts and washers as required including painting with one coat of aluminium paint after preparation of old surface complete all as specified and directed.
Dismantling of old unserviceable bending/broken PCC pole of any size with necessary disconnection of electric wire, demolition of concrete foundation including excavation and earth work as required and removing the same form site complete all as specified and as directed. Note :- (Dismantling of cross arms and insulators fixed with pole shall be measured and paid separately under relevant items here-in-before)
Supply and errection of Prestressed Concrete pole 9 mtr long , 102 mm X 172 mm at top and 102 mm X 279 mm at the bottom class 10 ncluding white and black paint up to 1.2 mtr and numbering to be done in black synthetic enamel paint complete all as specified and directed Note: PCC and earth work will be measured and paid separately.
M&L for PCC (1:3:6) type C-2 with using 40mm grade stone aggregate as in foundation of steel tubular poles and stay with necessary form work as required complete all as specified and directed.
M&L for coping with 20 mm graded aggregate in the ratio of 1:3:6 Type C-1. complete all as specified and directed by Engr-in-Charge.
Dismantling of old unserviceable stay assembly including stay wire complete with necessary demolition of concrete excavation and earth work as required and removing the same from site complete all as specified and directed.
S&F stay assembly complete with all accessories and stay clamps all as shown in electrical plate No 1 of SSR Part I with using stay rod of 16mm dia complete all as specified and directed. (Loop type insulator, excavation and earth work, concrete foundation and stay wire shall be measured and paid separately under relevant items of this Sch ‘A’)
M&L for dismantaling of insulators any type and size complete all as specified and directed by Engr-in-charge
S & F pin type insulator porcelain vitreous, white, brown or green insulator including one galvanized mild steel spindle two galvanized iron washer and one galvanized iron nut 100mm height 65mm dia for 1100 volts grade complete all directed.
S&F shackle type porcelain vitreous white, brown or green insulator of size 75mm height, 90mm dia (maximum) including mild steel straps of section 31mmx3mm, washers, 12mm dia insulator bolt and nut suitable for working pressure 1100 volts grade complete all as specified and directed.
S&F Loop type insulator, vitreous porcelain, white, brown or green Small size, with overall dimensions 65 x 90mm, clearance of hole 16mm. complete all as specified and directed.
S & F Post type insulator 11 KV, 79 mm dia, 254 mm height porcelain vitreous complete all as specified and directed.
Fixing only old serviceable any type insulator as obtain from Sch 'A' item No 15 here complete all as specified and directed.
S & F Galvanised stay strand, 7/4mm complete all as specified and directed.
Taking out existing LT UG cable 1100 volts PVC insulated armoured aluminium conductor of any size complete all specified and directed by Engr-in-Charge.
M& L for laying only cable XLPE/PVC Insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of sizes Note:- LT UG Cable will be issued under Sch B free for laying only (a) 35 Sqmm 3.5 core
(b) 50 Sqmm 3.5 core
(c) 70 Sqmm 3.5 core
(d) 95 Sqmm 3.5 core
(e) 120 Sqmm 3.5 core
(f) 185 Sqmm 3.5 core
Excavation in trenches not exceeding 1.5 mtrs wide and not exceeding 1.5 mtr deep in hard /dense soil for laying underground cables and post holes complete all as specified and directed.
Returning filling in including spreading levelling watering and well ramming in layres not exceeding 25 cm thick in hard/ dense soil.
Removing surplus soil to a distance not exceeding 50 m and depositing at a level not exceeding 1.5m above the starting point.
M&L for sand filling in trenches as cushioning to under ground cable provided with a layer of 8 cm deep before laying and 15 cm covering above the top edge of cable after laying complete all as specified and as directed by EIC. Note :- Punned thickness only shall be measured and paid.
Laying only old retrieved stone putty/brick/PCC cover on the cable abutting each other for the cable protection gap between two adjacent patties n.exc 10mm complete all as specified and directed by Engr-in-charge.
Material and labour for laying 40 to 50 mm thick quarry faced stone slab 25 to 30 cm wide and not exceeding 60 cm long laid dry abutting each other with gap between adjacent patties n.exc 10 mm for cable protection complete all as specified and directed by Engr-in-charge.
Supply and lay light grade GI pipe with all fittings complete laid in trench/ fixed to Wall / Poles etc with suitable clamp nuts, bolts washers etc required at site for protection of cable complete all as directed (a) 40 mm dia
(b) 50 mm dia
(c) 80 mm dia
M&L for Trimming and prunning upto safe distance from the over head lines including cutting branches of tree of size not exceeding 3" dia complete all as directed at site and disposel of branches/bushes to distance and cleaning the site all as directed by E-I-C Note :-(i) The necessary man power tool and plant, cutting tools and JCB if required for cutting/ prunning of branches is deemed to incl in the rate quoted for the job (ii) Proper shut down will be taken from JE E/M only.
Taking out old unsv /rusted/ broken body of LT panel of any size and capacity including unserviceable control switch gears like MCCB, bus bar of any type and size , MCB and Volt meter and ammeter etc from the site complete all as directed and specified by Engr-in-charge.
Supply, Install, testing and commissioning of LT panel from CPRI tested firms, outdoor type totally enclosed with front opening hinged doors with projected top and raised platform of suitable size weather, dust, vermin and water proof made out of CRCA sheet 3.15 mm thick including aluminium bus bar for 3 phase, 415 volts of capacity 400 Amps and one neutral sleeved with coloured sleeves insulation complete painting with powder coated paint including marking by paint of outgoing supply to various locations for identifiaction for the following (Note:- Initial drawing and design of the panel will be approved by AGE (I) Note:- (i) Suitable size of Stand for LT Panel made of MS angle iron duly painted with black colour in two coats over the on coat of red oxide primer is deemed to be inclusive of quoted rates.(ii) Cost of transportation from firm to site and the cost of labour for fixing of panel will deemed to be inclusive of quoted rates. INCOMER (a) MCCB 4 Pole, 415 V, Adjustable type, 250 Amps with breaking capacity 36 KA. - 01 No. (b) Digital Voltmeter 0-500 volts. - 01 No. (c) Digital Ammeter 0-500 Amps. - 01 No. (d) Phase indicator lamps (R-Y-B) LED type. - 01 Set. OUTGOING (a) MCCB 4 Pole, 415 V, Adjustable type, 200 Amps with breaking capacity 25 KA. - 01 No. (b) MCCB 4 Pole, 415 V, Adjustable type, 160 Amps with breaking capacity 25 KA. - 01 No. (c) MCCB 4 Pole, 415 V, Adjustable type, 63 Amps with breaking capacity 16 KA. - 03 No. (d) MCB SPN 6 -32 Amps, 10 KA, 240 V. - 02 Nos.
Supply, Install, testing and commissioning of LT panel from CPRI tested firms, outdoor type totally enclosed with front opening hinged doors with projected top and raised platform of suitable size weather, dust, vermin and water proof made out of CRCA sheet 3.15 mm thick including aluminium bus bar for 3 phase, 415 volts of capacity 300 Amps and one neutral sleeved with coloured sleeves insulation complete painting with powder coated paint including marking by paint of outgoing supply to various locations for identifiaction for the following, (Note:- Initial drawing and design of the panel will be approved by AGE (I) Note: (i) Suitable size of Stand for LT Panel made of MS angle iron duly painted with black colour in two coats over the one coat of red oxide primer is deemed to be inclusive of quoted rates.(ii) Cost of transportation from firm to site and cost of labour for fixing of panel will deemed to be inclusive of quoted rates. INCOMER (a) MCCB 4 Pole, 415 V, Adjustable type, 200 Amps with breaking capacity 25 KA. - 01 No. (b) Digital Voltmeter 0-500 volts. - 01 No. (c) Digital Ammeter 0-500 Amps. - 01 No. (d) Phase indicator lamps (R-Y-B) LED type. - 01 Set. OUTGOING (a) MCCB 4 Pole, 415 V, Adjustable type, 160 Amps with breaking capacity 25 KA. - 01 No. (b) MCCB 4 Pole, 415 V, Adjustable type, 63 Amps with breaking capacity 16 KA. - 04 Nos (c) MCB SPN 6 -32 Amps, 10 KA, 240 V. - 02 Nos.
Supply, Install, testing and commissioning of LT panel from CPRI tested firms, outdoor type totally enclosed with front opening hinged doors with projected top and raised platform of suitable size weather, dust, vermin and water proof made out of CRCA sheet 3.15 mm thick including aluminium bus bar for 3 phase, 415 volts of capacity 250 Amps and one neutral sleeved with coloured sleeves insulation complete painting with powder coated paint including marking by paint of outgoing supply to various locations for identifiaction for the following, (Note:- Initial drawing and design of the panel will be approved by AGE (I) Note:- (i) Suitable size of Stand for LT Panel made of MS angle iron duly painted with black colour in two coats over the one coat of red oxide primer is deemed to be inclusive of quoted rates.(ii) Cost of transportation from firm to site and cost of labour for fixing of panel will deemed to be inclusive of quoted rates. INCOMER (a) MCCB 4 Pole, 415 V, Adjustable type, 160 Amps with breaking capacity 25 KA. - 01 No. (b) Digital Voltmeter 0-500 volts. - 01 No. (c) Digital Ammeter 0-500 Amps. - 01 No. (d) Phase indicator lamps (R-Y-B) LED type. - 01 Set. OUTGOING (a) MCCB 4 Pole, 415 V, Adjustable type, 125 Amps with breaking capacity 16 KA. - 01 No (b) MCCB 4 Pole, 415 V, Adjustable type, 63 Amps with breaking capacity 16 KA. - 03 Nos. (c) MCB SPN 6 -32 Amps, 10 KA, 240 V. - 02 Nos.
Supply, Install, testing and commissioning of LT panel from CPRI tested firms, outdoor type totally enclosed with front opening hinged doors with projected top and raised platform of suitable size weather, dust, vermin and water proof made out of CRCA sheet 3.15 mm thick including aluminium bus bar for 3 phase, 415 volts of capacity 200 Amps and one neutral sleeved with coloured sleeves insulation complete painting with powder coated paint including marking by paint of outgoing supply to various locations for identifiaction for the following, (Note:- Initial drawing and design of the panel will be approved by AGE (I) Note:- (i) Suitable size of Stand for LT Panel made of MS angle iron duly painted with black colour in two coats over the one coat of red oxide primer is deemed to be inclusive of quoted rates.(ii) Cost of transportation from firm to site and cost of labour for fixing of panel will deemed to be inclusive of quoted rates. INCOMER (a) MCCB 4 Pole, 415 V, Adjustable type, 125 Amps with breaking capacity 16 KA. - 01 No (b) Digital Voltmeter 0-500 volts. - 01 No. (c) Digital Ammeter 0-500 Amps. - 01 No. (d) Phase indicator lamps (R-Y-B) LED type. - 01 Set. OUTGOING (a) MCCB 4 Pole, 415 V, Adjustable type, 63 Amps with breaking capacity 16 KA. -03 Nos. (b) MCB SPN 6 -32 Amps, 10 KA, 240 V. - 02 Nos.
Supply, Install, testing and commissioning of LT panel from CPRI tested firms, outdoor type totally enclosed with front opening hinged doors with projected top and raised platform of suitable size weather, dust, vermin and water proof made out of CRCA sheet 3.15 mm thick including aluminium bus bar for 3 phase, 415 volts of capacity 400 Amps and one neutral sleeved with coloured sleeves insulation complete painting with powder coated paint including marking by paint of outgoing supply to various locations for identifiaction for the following (Note:- Initial drawing and design of the panel will be approved by AGE (I) Note:- (i) Suitable size of Stand for LT Panel made of MS angle iron duly painted with black colour in two coats over the on coat of red oxide primer is deemed to be inclusive of quoted rates.(ii) Cost of transportation from firm to site and the cost of labour for fixing of panel will deemed to be inclusive of quoted rates. INCOMER (a) MCCB 4 Pole, 415 V, Adjustable type, 250 Amps with breaking capacity 36 KA. - 01 No. (b) Digital Voltmeter 0-500 volts. - 01 No. (c) Digital Ammeter 0-500 Amps. - 01 No. (d) Phase indicator lamps (R-Y-B) LED type. - 01 Set. OUTGOING (a) MCCB 4 Pole, 415 V, Adjustable type, 125 Amps with breaking capacity 16 KA. - 01 No (b) MCCB 4 Pole, 415 V, Adjustable type, 63 Amps with breaking capacity 16 KA. - 04 No. (c) MCCB 4 Pole, 415 V, Adjustable type, 40 Amps with breaking capacity 16 KA. - 04 No.(d) MCB 4 pole 63 Amps, 10 KA, 415 Volt. - 04 Nos. (e ) MCB SPN 32 Amps, 10 KA, 240 V. - 04 Nos.
Supply, Install, testing and commissioning of LT panel from CPRI tested firms, outdoor type totally enclosed with front opening hinged doors with projected top and raised platform of suitable size weather, dust, vermin and water proof made out of CRCA sheet 3.15 mm thick including aluminium bus bar for 3 phase, 415 volts of capacity 200 Amps and one neutral sleeved with coloured sleeves insulation complete painting with powder coated paint including marking by paint of outgoing supply to various locations for identifiaction for the following, (Note:- Initial drawing and design of the panel will be approved by AGE (I) Note: (i) Suitable size of Stand for LT Panel made of MS angle iron duly painted with black colour in two coats over the one coat of red oxide primer is deemed to be inclusive of quoted rates.(ii) Cost of transportation from firm to site and cost of labour for fixing of panel will deemed to be inclusive of quoted rates. INCOMER (a) MCCB 4 Pole, 415 V, Adjustable type, 125 Amps with breaking capacity 16 KA. - 01 No (b) Digital Voltmeter 0-500 volts. - 01 No. (c) Digital Ammeter 0-500 Amps. - 01 No.(d) Phase indicator lamps (R-Y-B) LED type. - 01 Set. OUTGOING (a) MCCB 4 Pole, 415 V, Adjustable type, 63 Amps with breaking capacity 16 KA. - 02 Nos. (b) MCB SPN 40 Amps, 10 KA, 240 V. - 10 Nos.
M&L for Earthing of galvanized steel earth plate electrode 600x600x6.3mm thick buried directly in ground vertically to a depth not less than 2.25 metre below ground level with top edge of the plate not less than 1.5 metre below normal ground level connected to GI strip 32x6mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical plate No. 3 of SSR Part-I and connected to earthing test point including filling of alternate layer of charcoal or coke and salt around the electrode necessary earth work, in any type of soil, PCC 1:2:4 type B1 using 20mm graded stone aggregate, funnel, GI watering pipe 20mm dia (light grade), 50mm thick RCC cover reinforced with 8mm dia CTD bars @ 150mm C/C both ways with 2 Nos. 10mm dia 150mm long MS handle emboded in to slab, wire mesh, etc complete and testing on completion all as specified and directed by EIC.
Taking out old Unsv panel door with old broken hinges and supply and fix with new MS hinges medium weight of 75mm long fix to panel & panel door with suitable nut & bolt /welding and painting to match the existing colour of panel & refixing the same complete all as specified and directed.
M & L for Painting of LT panel with spray machine by applying two coats of synthetic enamel paint of existing colour or any other colour approved by AGE (I) after scrubing the rusted surfaces of LT panel to match with original surface complete all as specified and directed by Engineer-in-Charge.
S R ENTERPRISES
M/S JAGDAMBA ENTERPRISES
Shri Electrical Enterprises
vinayandsons
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .