Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹47.6 LAccepted-AOC KAJANIBARI DINJAN PO DINJAN DIST TINSUKIA ASSAM786189 | DINJAN | TINSUKIA | ASSAM | 786189 | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹49.8 L+₹1.3 L (2.70%)Rejected-Finance P O WEST SRIPURIA DIST TINSUKIA ASSAM PIN 786 145 | TINSUKIA | ASSAM | 786145 | L2 | Rejected-Finance NOT BEING L1 | |
| 3 | L3₹50.2 L+₹1.7 L (3.42%)Rejected-Finance | L3 | Rejected-Finance NOT BEING L1 | |
| 4 | L4₹50.4 L+₹1.9 L (3.99%)Rejected-Finance 06 DATALPARA A K DEV ROAD DATALPARA KAMRUP ASSAM 781025 UDYAM AS 03 0016239 | KAMRUP METRO | ASSAM | 781025 | L4 | Rejected-Finance NOT BEING L1 | |
| 5 | L5₹51.3 L+₹2.8 L (5.71%)Rejected-Finance DINJAN DIST TINSUKIA ASSAM 786 189 E 67 CWE DINJAN | TINSUKIA | ASSAM | 786189 | L5 | Rejected-Finance NOT BEING L1 |
| Sl No | Description | Qty | Unit | M/S CHANDAN ENTERPRISE L1 | jitendra narayan goswami L7 | M/s GANDHESWAR PHUKAN L3 | Construction House L2 | M/S AUTOMOTIVE WORLD L6 | M/s Kanchan Enterprise L4 | PATKAI ENTERPRISE L5 |
|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Demolition of cement concrete (un reinforced) in ground floors and paving n. exc. 15 cm thickness (below or above ground level) removing rubbish off the premises etc complete all as directed | 4.5 | Cum | 850 ₹3,825 | 950 ₹4,275 | 890 ₹4,005 | 900 ₹4,050 | 1,050 ₹4,725 | 800 ₹3,600 | 780 ₹3,510 Lowest |
| 2.00 | Dismantling timber scantlings 40 sq. cm and over in section, in any position of Un-Framed work, complete all as specified and directed. | 0.6 | Cum | 800 ₹480 | 980 ₹588 | 850 ₹510 | 860 ₹516 | 1,000 ₹600 | 850 ₹510 | 650 ₹390 Lowest |
| 3.00 | Dismantling timber scantlings in fillets, rails, posts, rafters, purlins, etc. under 40 sq. cm in section complete all as specified and directed. | 50 | RM | 20 ₹1,000 | 35 ₹1,750 | 15 ₹750 Lowest | 22 ₹1,100 | 30 ₹1,500 | 18 ₹900 | 24 ₹1,200 |
| 4.00 | Dismantling Asbestos cement (corrugated, semicorrugated, etc.) sheets in roof coverings any thickness, complete all as specified and directed. | 750 | Sqm | 35 ₹26,250 Lowest | 40 ₹30,000 | 38 ₹28,500 | 40 ₹30,000 | 45 ₹33,750 | 38 ₹28,500 | 42 ₹31,500 |
| 5.00 | Dismantling of wall and ceiling boards (fibre, pulp, insulation etc) or insulation boards/slabs of any thickness including cover fillets complete all as directed. | 250 | Sqm | 40 ₹10,000 Lowest | 45 ₹11,250 | 40 ₹10,000 Lowest | 42 ₹10,500 | 45 ₹11,250 | 45 ₹11,250 | 48 ₹12,000 |
| 6.00 | Demolition of stone slabs and tiles of any description or thickness in floors, aprons etc. complete all as specified and directed. | 20 | 10 Sqm | 800 ₹16,000 | 650 ₹13,000 Lowest | 850 ₹17,000 | 860 ₹17,200 | 1,050 ₹21,000 | 800 ₹16,000 | 650 ₹13,000 Lowest |
| 7.00 | Taking down chowkhats or frame with shutters (without taking off shutters from the frame) not exceeding 1.50 Sqm each complete all as directed. | 20 | Each | 130 ₹2,600 | 110 ₹2,200 Lowest | 135 ₹2,700 | 140 ₹2,800 | 120 ₹2,400 | 138 ₹2,760 | 139 ₹2,780 |
| 8.00 | Taking down cement plaster or cement lime plaster on walls /ceiling of any description from concrete or brick wall etc including raking out joints, hacking for key, scrubbing down with water and disposing off the retreived debris as directed including necessary scaffoldings etc complete all as directed. | 500 | Sqm | 55 ₹27,500 Lowest | 80 ₹40,000 | 57 ₹28,500 | 60 ₹30,000 | 85 ₹42,500 | 58 ₹29,000 | 59 ₹29,500 |
| 9.00 | Taking up or down 15 mm bore steel water tubing galvanised including connections from trenches/wall/floor/ceiling etc and keeping serviceable quantity in safe custody for re-use at same site or other site complete all as specified and as directed. | 50 | RM | 20 ₹1,000 Lowest | 20 ₹1,000 Lowest | 25 ₹1,250 | 25 ₹1,250 | 30 ₹1,500 | 25 ₹1,250 | 22 ₹1,100 |
| 10.00 | Taking up or down 20 mm bore steel water tubing galvanised including connections from trenches/wall/floor/ceiling etc and keeping serviceable quantity in safe custody for re-use at same site or other site complete all as specified and as directed. | 30 | RM | 25 ₹750 Lowest | 25 ₹750 Lowest | 25 ₹750 Lowest | 28 ₹840 | 35 ₹1,050 | 28 ₹840 | 26 ₹780 |
Tender Value
₹48 L
EMD Value
₹96,000
Closing Date
14 Jul 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE DINJAN
GE DINJAN, PANITOLA (PO), DIBRUGARH (DIST), ASSAM PIN-786183
SPL REPAIR TO ROOF SHEET AND OTHER MISC WKS IN BLDG NO P-25 AND P-28 AND CERTAIN REVENUE AND MINOR WKS UNDER GE DINJAN
2025_MES_716626_1
C/8870/E8
Open Tender
Civil Works
Item Rate
180 days
DINJAN MIL STN
AS PER TENDER DOCUMENTS
10 documents required · 10 mandatory
₹500
GE DINJAN
₹96,000
Yes
11 Aug 2025
25 Jun 2025
21 Jul 2025
25 Jun 2025
14 Jul 2025
9 Jul 2025
Amount
Demolition of cement concrete (un reinforced) in ground floors and paving n. exc. 15 cm thickness (below or above ground level) removing rubbish off the premises etc complete all as directed
Dismantling timber scantlings 40 sq. cm and over in section, in any position of Un-Framed work, complete all as specified and directed.
Dismantling timber scantlings in fillets, rails, posts, rafters, purlins, etc. under 40 sq. cm in section complete all as specified and directed.
Dismantling Asbestos cement (corrugated, semicorrugated, etc.) sheets in roof coverings any thickness, complete all as specified and directed.
Dismantling of wall and ceiling boards (fibre, pulp, insulation etc) or insulation boards/slabs of any thickness including cover fillets complete all as directed.
Demolition of stone slabs and tiles of any description or thickness in floors, aprons etc. complete all as specified and directed.
Taking down chowkhats or frame with shutters (without taking off shutters from the frame) not exceeding 1.50 Sqm each complete all as directed.
Taking down cement plaster or cement lime plaster on walls /ceiling of any description from concrete or brick wall etc including raking out joints, hacking for key, scrubbing down with water and disposing off the retreived debris as directed including necessary scaffoldings etc complete all as directed.
Taking up or down 15 mm bore steel water tubing galvanised including connections from trenches/wall/floor/ceiling etc and keeping serviceable quantity in safe custody for re-use at same site or other site complete all as specified and as directed.
Taking up or down 20 mm bore steel water tubing galvanised including connections from trenches/wall/floor/ceiling etc and keeping serviceable quantity in safe custody for re-use at same site or other site complete all as specified and as directed.
Excavating over areas, n exc 1.5 m deep and getting out in soft/loose soil complete all as specified and directed.
Excavating over areas, exc 1.5 m deep and each additional 1.5m or part thereof in depth beyond the first 1.5 m and getting out in soft/loose soil complete all as specified and directed.
Excavating in trenches n exc 1.5m wide and n exc 1.5m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10sqm on plan and n exc 1.5m in depth and getting out in soft/loose soil complete all as specified and directed.
Excavating in trenches n exc 1.5m wide and exc 1.5m but n exc 3m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10sqm on plan and n exc 1.5m in depth and getting out in soft/loose soil complete all as specified and directed.
Returning filling in with excavated soil including spreading, leveling, watering and well ramming in layers not exceeding 25cm thick complete all as specified and directed.
Removing excavated soils to a distance not exceeding 50 metres and depositing where directed at a level nexc. 1.5 metre above the starting point complete all as specified and directed.
Surface dressing n exc 15cm deep in hard/dense soil complete all as specified and directed.
M&L for Sand filling under floors or in foundations including watering and consolidation complete all as specified and directed.
M&L for hardcore of broken bricks of guage exceeding 63 mm but not exceeding 100 mm, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to a true surface complete all as specified and as directed.
M&L for plain cement concrete (1:4:8) type D-2, using 40mm graded stone aggregate as in foundations, filling and mass concrete complete all as specified and as directed.
M&L for PCC 1:3:6, type C2 (using 40mm graded crushed stone aggregated) as in surfaces channels and drains incl necessary formwork complete all as specified and directed.
M&L for plain cement concrete Type B1 1:2:4 (using 20mm graded stone aggregates) as in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs , water troughs and the like including weathering, slightly rounded or chamfered angles and throating, as directed inclusive of necessary form work complete all as specified and directed.
M&L for precast reinforced cement concrete, type B1, 1:2:4 (20 mm graded aggregate) as in cover slabs (for man holes etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces and similar work incl necessary formwork set in cement mortar 1:4 complete all as specified and directed. (Note: Steel reinforcement shall be measured & paid separately) .
M&L for precast cement concrete type B0 (1:2:4) (using 12.50 mm graded aggregate) as in louvers and jallies, 25mm thick (measured solid), including all mouldings but excluding frame set in cement mortar (1:6) complete all as specified and directed.
M&L for RCC type B-1, 1:2:4 (20mm graded crushed stone aggregate) as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and directed. (Note: Steel reinforcement shall be measured & paid separately) .
M&L for reinforced cement concrete type B-0 (1:2:4) (using 12.5 mm graded stone aggregate) as Walls, retaining walls, basement walls, ballast walls and the like; any thickness; above top of footings; including attached pilaster and buttresses, etc complete all as specified and as directed.
M&L for reinforced cement concrete (1:2:4) type B-1 (Nominal Mix) (using 20 mm graded stone aggregate) as in slab supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed. Note : Reinforcement shall be measured and paid separately under relevant item.
M&L for reinforced cement concrete (1:2:4) type B-1 (Nominal Mix) (using 20 mm graded stone aggregate) as in columns, pillars, post and struts etc complete all as specified and as directed. (Note: Steel reinforcement shall be measured & paid separately) .
Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete using extra cement including forms, moulds mitred/stopped ends etc complete all as specified and directed.
Demolition of brickwork or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as directed.
M&L for brick work with sub class 'B' burnt clay bricks straight or curved on plan exc 6 meter mean radius built in cement mortar 1:6 complete all as specified and as directed.
M&L for brick work with sub class 'B' burnt clay bricks straight or curved on plan to any radius in half brick thick walls built in cement mortar 1:4 complete all as specified and as directed.
Use and waste form work to sides of foundation, footings, bases of columns, plinth beams flat rough finished surfaces of concrete complete all as specified and as directed.
Use and waste formwork to soffits of suspended slabs such as roof slab, floor slabs, landings and similer works, for rough finished flat surfaces of concrete, thickness of slab not exc 200 mm, complete all as specified and directed.
Use and waste for formwork to faces of sides and soffits of floor or roof beams, cantilevers, lintels, shelves including supports, overhangs, etc for rough finished flat surfaces of concrete complete all as specified and directed
Use and waste for formwork to sides of pillars,columns etc rough finished concrete surfaces complete all as specified and directed.
M&L for second class hardwood, scantlings, wrought, in timber fixed work complete all as specified and directed.
M&L for 2nd class hard wood plain fillets. square, rectangular or triangular in section, wrought, secured with nails or brads of sectional area exc 6 Sqcm and not exc 13 Sqcm complete all as specified and directed. .
S&F Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing, complete all as specified and directed.
S&F factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification and drawing, complete all as specified and directed.
S&F Aluminium anodized barrel tower bolts of extruded section, 100 mm long, complete all as specified and directed.
S&F 75 mm size, butt hinges, heavy weight, cold rolled mild steel complete all as specified and as directed.
S&F extruded aluminium alloy handles, fabricated type, anodized, 100 mm size , complete all as specified and directed.
S&F 300mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed, complete all as specified and directed.
S&F in repairs curtain rails, Harrison rails, mild steel, chromium plated with fixing brackets, stops, rollers etc complete all as specified and as directed.
S&F in repair brass chromium plated tubular towel rail, D type, 60cm long, 20mm dia with brackets complete all as specified and as directed.
S&F in repair floor door stopper with overall length of cover plate 150mm of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor complete all as specified and directed.
S&F for stainless steel wire mesh, 0.36 mm nominal dia of wire and average width of aperture 1.4mm and fixed with stainless steel wire staples including necessary welding work complete all as specified and as directed.
M&L for TMT bars 10 mm dia and over, as reinforcement for concrete cut to length, bent to shape required including cranking, bending, spirally hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.90mm dia, complete all as specified and directed.
M&L for TMT bars 6 to 8 mm dia , as reinforcement for concrete cut to length, bent to shape required including cranking, bending, spirally hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.90mm dia, complete all as specified and directed.
M&L for TMT bars 5mm dia over upto and including 10mm dia in stirrups, spacers and binders, as reinforcement for concrete cut to length, bent to shape required including cranking, bending, spirally hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.90mm dia, complete all as specified and directed.
M&L for anodised aluminium frame of doors, windows, ventilators with one or more rebates including joining cleats for fixing etc including powder coating of minimum 50 micron thickness complete all as specified Note :- Weight of Aluminum sections for frames and shutters shall be only considered for payment. Cost of other consumables required for the item shall be deemed to be included in the quoted rate. However glass panes / Bakelite sheet / wire cloth / mortice lock / locking stay / floor spring / floor door stopper only will be measured and paid separately under respective items as supply only. Fixing element of these items shall be deemed to be included in quoted rate.
M&L for Powder coated aluminium (minimum thickness of powder coating 50 micron) work for doors, windows, ventilators and partitions (Fixed portions) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-Charge.
S&F anodised aluminium grill, (anodised transparent or dyed to required shade according to IS:1868 with minimum anodic coating of grade AC 15) of approved design / pattern, with approved standard section and fixed to the existing window frame with C.P. brass/stainless steel screw @200mm c/c, including cutting the grill to proper opening size for fixing approved anodised aluminium standard section around the opening, complete all as per manufacturer instruction and directed by Engr-in-Charge..
S&F GI snap grid frame work of size 605mm x 605mm frame work for ceiling with aluminium tee section of size 23.5mm x 26.4mm x 1.4mm thick and aluminium angle section of size 36.5mm x 25mm x 1.4mm thick, for false ceiling including Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia, 40mm long including 6mm thick high pressure, oceanic pre-primed, self embossed, non asbestos fibre cement decorative board, water, termite and fire resistant for insulation and acoustic purpose fixed or laid/ inserted to timber/GI/Aluminium framework with screws including two coat of oil bound distemper on ceiling surface complete all as specified and as directed.
S&F pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of profile as approved, any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed.
S&F pre-painted galvalume aluminium zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in ridges/valley gutter, fixed with self tapping screws complete all as specified and as directed. Note : Colour of ridge shall be same colour as that of sheet used for roof.
M&L for rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations complete all as specified and as directed.
M&L for coloured 450x300x7-8 mm thick glazed ceramic tiles on vertical surfaces such as skirting, dado and risers to steps etc, set and jointed in neat cement slurry and pointed in white cement mixed with pigment to match, over and including 10mm thick backing coat in cement mortar (1:4) , complete all as specified and directed.
M&L for non skid ceramic coloured tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.11sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in coloured cement to match the shade of tiles with and including 15mm thick screed bed or bedding layer of cement morter (1:6) for laying of floor finishes complete all as specified and directed.
M&L for non skid ceramic coloured tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.11sqm but not exceeding 0.18 sqm, as in skirting. set and jointed in neat cement slurry and pointed in coloured cement to match the shade of tiles over and including 10mm thick backing coat in cement mortar (1:4) , complete all as specified and directed.
M&L for non skid ceramic coloured tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in coloured cement to match the shade of tiles over and including 15mm thick screed bed or bedding layer of cement morter (1:6) for laying of floor finishes complete all as specified and directed.
M&L for prepolished, chequered cement concrete tiles of size 25cmx25cmx22mm thick, as in floors etc, including 15 mm thick screed bed or bedding in cement mortar (1:6) and set and jointed in neat cement slurry and pointed in grey cement and pigments to match with the shade of tiles complete all as specified and as directed.
M&L for 18-20mm thick granite slabs of any type (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like, set and jointed in net cement slurry and pointed in white cement (1:2) using marble dust with admixture of pigment to match shade of granite including necessary moulding at edges laid over and including 20mm thick cement mortor screed bed in cement mortor (1:6) complete all as specified and directed.
M&L for machine pressed precast conctete interlocking paver block, design & shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade with grey cement and pigment including 50 mm thick compacted bed of coarse sand, filling the joints with fine sand etc. complete all as specified and as directed.
M&L for 75 mm thick, plain cement concrete (1:3:6) type C-2 (using 40mm graded stone aggregate) as in plinth protection / hard standing etc, finishing cement concrete surface even and smooth without using extra cement including making joints with bitumastic filing in proportion of bitumen and sand (1:2) complete all as specified and as directed.
M&L for 75mm thick PCC (1:4:8) type D-2 (using 40mm graded crushed stone aggregate) as sub base of flooring complete all as specified and directed.
M&L for 40 mm thick PCC (1:2:4) type B0 (using 12.5 mm graded stone aggregate) as in sub base of floors finished even and smooth with using extra cement, complete all as specified and directed.
M&L for rendering 15mm thick in cement morter (1:6) on on other than fair faces of brick work or concrete surfaces, finished even and smooth without using extra cement, complete all as specified and directed.
M&L for rendering 5mm thick in cement morter (1:3) on ceiling surfaces, finished even and smooth without using extra cement, complete all as specified and directed.
M&L for rendering 20 mm thick on fair faces of external wall of brick work or stone surfaces in two layers (10mm thick each layer) in cement mortar in (1:4) using water proofing compound in top layer and finished even and smooth (without using extra lime or cement) complete all as specified and directed. Note: Water Proofing Compound measured and paid separately.
Supply only liquid Water Proofing Compound ISI marked of approved make complete all as specified and directed.
M&L for applying three coats of white wash on new wall surface including preparation of surface, complete all as specified and directed.
M&L for applying three coats of white wash on new ceiling surface including preparation of surface, complete all as specified and directed.
M&L for preparation old decorated plastered or unplastered surfaces of ceiling by brooming down or steel wire brushing, scraping down, the surfaces covered by smoke soot, growth of moulds and moss, efflorescent, having oil and greases spots and applying one coat of white wash complete all as specified and as directed.
M&L for preparation newly plaster surfaces of wall, chajja, facia etc and applying two coats of 100% premium Acrylic emulsion paint having VOC less than 50 gm/ litre and UV resistant as per IS-15489:2004 alkali and fungal resistant exterior paint of required shed (company depot tinted) with silicon additives 1.43 litrs/ 10 Sqm over and including primer coat of exterior primer applied 0.90 litre/10 Sqm over new surfaces using Airless spray technology with maximum working pressure of 3300 PSI and capable of operating single spray gun with a maximum material hose length of 30 mtr, the spray machine should be of reputed manufacturer with pro guard technology and capability of tracking pressure and paint usage and certified by paint manufacturer and as mentioned in PS and acessories complete all as specified and directed.
M&L for complete removal of existing treatment from walls by scrapping with mechanical wall sander (having mechanical vaccum mechanism) having RPM not less than 1500, sanding pad of 80 Grit having dia of 7"/9" to make the surface free from dust, loose paint etc. and applying two coats of 100% premium Acrylic emulsion paint having VOC less than 50 gm/ litre and UV resistant as per IS-15489:2004 alkali and fungal resistant exterior paint of required shed (company depot tinted) with silicon additives 1.43 litrs/ 10 Sqm over and including primer coat of exterior primer applied 0.90 litre/10 Sqm over new surfaces using Airless spray technology with maximum working pressure of 3300 PSI and capable of operating single spray gun with a maximum material hose length of 30 mtr, the spray machine should be of reputed manufacturer with pro guard technology and capability of tracking pressure and paint usage and certified by paint manufacturer and as mentioned in PS and acessories complete all as specified and directed.
M&L for preparation of newly plastered surface of walls etc and applying two coats of oil bound distemper over a coat of chalk whiting priming paint over 1.50 mm thick wall care putty complete all as specified and as directed.
S&F 3 mm thick sheet glass, ordinary quality and glazing with oil putty in squares n.exceeding 0.50sqm in each pane , complete all as specified and directed.
S&F 4 mm thick sheet glass, ordinary quality and glazing with oil putty in squares n.exceeding 0.50sqm in each pane , complete all as specified and directed.
M&L for preparing of new wood and wodd based surfaces of any description , over 10 cm in width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of pink primer, complete all as specified and directed.
M&L for preparing of old painted wood and wood based surfaces of any description over 10 cm width or girth, not otherwise described and applying one coat of synthetic enamel paint complete all as specified and directed.
M&L for preparing of new wooden surfaces of any description , but not exceeding 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer, complete all as specified and directed.
S&F 15 mm bore, steel tubes, galvanised, medium grade with all fittings & fixed complete to wall and ceiling or laid in floors etc complete all as specified and directed.
S&F 20 mm bore, steel tubes, galvanised, medium grade with all fittings & fixed complete to wall and ceiling or laid in floors etc complete all as specified and directed.
Relaying/refixing only old serviciable galvanised steel tubing 15 mm bore in new or old location using new fitting and fixures complete trenches/walls/floors complete all as specified.
Relaying/refixing only old serviciable galvanised steel tubing 20 mm bore in new or old location using new fitting and fixures complete trenches/walls/floors complete all as specified.
Cutting existing steel tubing for alterations or additions (Each cut measured) and connection with new PPR pipe 40/50mm bore including fittings required complete all as specified.
Supply, laying, connection and testing, 25mm outer dia 3- layer PP-R polypropylene random co-polymer pipes SDR 7.4 (PN16) stablised and anti microbial fusion welded having thermal stability for hot and cold water supply all PP-R plain and brass threaded polypropylene random fittings laid in trenches complete all as specified and as directed. Note : Excavation and earth work shall be measured and paid seperately.
S&F PPR gate valves (brass insert) as per requirement of the site for 25 mm bore pipes, complete all as specified and as directed.
Dismantling water tanks and removing to store of (exceeding 500 ltr & not exceeding 1000 ltr capacity) complete all as specified and as directed.
S&F 500 litres capacity rotational moulded polyethylene water storage tanks (cylindrical or vertical with closed top) as per IS 12701:1996, hoisted and fixed in position including provision of 20/15mm bore medium grade pipe for connecting inlet, outlet, overflow and washout pipe including 20 mm bore, ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixedcomplete all as specified and as directed.
S&F in repairs, 15mm chromium plated Bib taps, cast copper alloy with crutch or butterfly handle, fancy type, screwed down, screwed for iron pipe or for brass ferrule and fixed, complete all as specified and directed.
S&F in repair 15 mm bore, Pillar taps, fancy type, cast copper alloy, chromium plated with capstan heads, screwed down high pressure with or without lettered 'Hot or Cold' with long screwed shanks and fly nuts, screwed for iron pipe complete all as specified and as directed.
S&F in repair 15 mm bore wall mixer Non telephonic,cast copper alloy with capsten head, chromium plated, fancy type screwed down high pressure with letter hot and cold with long screwed shank and flynuts screwed for iron pipe, complete all as specified and directed.
S&F in repairs 15 mm bore, stop valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions complete all as specified and directed.
S&F in repair 20 mm bore Gun metal gate or globe valve with iron wheel head screwed both ends for iron pipe complete all as specified and directed.
S&F brass valves of size 15 mm bore high pressure, with polythene float and fly nut, screwed for iron pipe etc complete all as specified and directed.
S&F in repairs, PTMT(half or full threaded) waste coupling 40mm for sink (min weight 32mm - 45gms/40mm - 60gms) complete all as specified and as directed.
S&F Shelf of PTMT fixed with and including Chromium plated brass screws and wooden/plastic cleats (Minimum weight 300gms) complete all as specified and as directed.
S&F Liquid soap container of PTMT fixed with and including Chromium plated brass screws and wooden/plastic cleats.(Minimum weight 105gms) complete all as specified and as directed.
S&F Towel Rail 600mm long of PTMT fixed with and including Chromium plated brass screws and wooden/plastic cleats (Minimum weight 190gms) complete all as specified and directed.
S&F in repair 450mm long PVC connections 15mm size with PTMT nuts, complete all as specified and directed.
S&F PVC (SWR) pipes 110mm bore single socketed, in any length with rubber ring joints laid in trenches or in floors, complete all as specified and directed.
S&F in repair PVC (SWR) pipes 75mm bore single socketed, in any length with rubber ring joints laid in trenches or in floors, complete all as specified and directed.
S&F PVC (SWR) pipes type 'B' 110mm bore, single socketed in any length with rubber ring joints fixed to walls using MS holder bat, fixed complete all as specified and as directed.
S&F in repair PVC (SWR) pipes type 'B' 75 mm bore, single socketed in any length with rubber ring joints fixed to walls using MS holder bat, fixed complete all as specified and as directed.
S&F PVC (SWR) bends any radius 110mm bore, complete all as specified and directed.
S&F in repair PVC (SWR) junction single, (Single T) equal or unequal, 110 mm bore complete all as specified and directed.
S&F in repair PVC (SWR) vent cowl 110mm bore, complete all as specified and directed.
S&F PVC (SWR) vent cowl 75mm bore, complete all as specified and directed.
S&F in repair PVC (SWR) floor trap dia of outlet 75mm, plain with grating including jointing with solvent cement complete all as specified and as directed.
M&L for reinforced concrete pipes, class NP2, 150 mm bore, laid and jointed with collars complete all as specified and as directed.
M&L for concrete bed , plain cement concrete (1:3:6) type C-2 ( using 40mm graded crushed stone aggregate) in bedding to SGSW/NP2 drain pipes, including packing under and haunching against the sides of pipes after they are laid and tested, for 150mm pipe, complete all as specified and as directed.
Cutting into existing manholes for connecting new drains, making good to pipe and plastering the distrubed portions in cement mortar (1:3) to match with surround surfaces, cutting out existing benching and forming branch channel (1/2 round or 3/4 round section) in cement concrete (1:2:4) type B-1 finished smooth and reforming benching as required for 150/160mm bore pipe complete all as specified and as directed.
M&L for conventional type RCC Septic Tank for 50 users as per drawing No. CESZ /TD/61 sheet No. 1&2, complete all as specified and as directed by Engr-in-Charge.
S&F in repair Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete all as specified and directed.
S&F PVC low level flushing cistern, 10 liter capacity, valveless, symphonic action type with inlet, ball valve, float and handle incl bracket, PVC connection pipe and flush pipe of polyethylene of low or high density complete all as specified and as directed.
S&F in repairs soap dish of stainless steel, fixed to plugs with chromium plated brass screws complete all as specified and as directed.
S&F Vitreous china wash down water closet pan (pedestal pattern), white, including connection to outgoing drain and flushing pipe, anti syphonic pipe including PVC seat and cover complete but excluding flushing cistern & flush pipe including making good to disturbed surfaces of floor using concrete (1:4:8) type D2 and to match with existing specifications including taking down old unserviceable complete all as specified and as directed.
S&F Vitreous china premium/ 1st quality wash down water closet, wall hung EWC, white/ ivory/off white (closed pattern incl all necessary accessories like rag bolts/ gel gasket etc. (excluding flushing cistern & flush pipe) including making good to disturbed surfaces of floor using concrete (1:4:8) type D2 and to match with existing specifications including taking down old unserviceable complete all as specified and as directed. complete in all respect all as specified
S&F in repairs vitreous china wash basin, size 550x400mm, white, flat back, including 32mm bore PVC (HDPE) waste pipe 450mm long, 32mm bore CP waste coupling, chain, plug and porcelain stopper & brackets including cutting for and pinning in ends of brackets but excluding tap complete all as specified and as directed.
S&F in repairs Flush pipe of polyethylene of low or high density or PVC. 32 mm dia, for low level cistern complete all as specified and as directed.
S&F in repairs toilet paper holder, brass, chromium plated , fixed to walls with (CP) brass screwscomplete all as specified and as directed.
M&L for water proofing treatment on RCC roof etc. comprising with the following operation & as specified herein below:- (a) Taking down existing old tarfelt, bituminous compound including cleaning & removing debris to a distance exc 100 m n.exc.250m. (b) M&L 25 thick cement concrete type B0 1:2:4 ( 12.5 mm graded aggregate) finished even and smooth. (c) M&L for 15 mm thick screed bed in 1:6 finished even and smooth. (d) Preparing & cleaning of fully dried cement plastered surface. (e) Applying one coat of cold bituminous primer to the plastered surface @ 0.25 litres per sqm conforming IS-3384. (f) A layer of APP based polymeric membrane membrane 3mm thick (minimum) weighing 3.5 kg per sqm reinforced with polyster non woven fabric (weighing not less than 160 gms/sqm) shall be applied over bituminous primer as specified above. Application of polymeric membrane shall be by torch application. The over lap shall be minimum 100 mm on transverse direction and 75 mm in longitudinal direction. (g) One coat of aluminium paint over APP membrane @0.11Kg/Sqm. Note:- Prior to execution of the APP Membrane works, leak proof test shall be done by ponding water on roof slab to minimum depth of 25 mm. The entire roof slab shall be flooded with water for 48 hours. The necessary barrier shall be made to make feasible to stagnate water for 48 hours on roof slab.
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc
Taking down carefully old serviceable Main Switch, DB's consisting of MCBs wooden/GI/MS sheet board etc for kept in store and for later use all as directed (To be measured only when found serviceable in all respects complete for reuse)
M&L for point wiring with 1.5 Sqmm (nominal area), FRLSH PVC insulated, multistranded, single core unsheathed, copper conductor cables passing through and including PVC casing caping with all fittings and accessories of PVC casing caping (like Tee, bend etc.) fixed to walls /ceiling etc. with and including 1.5 Sqmm (nominal area) FRLHS PVC insulated, unsheathed, stranded, single core, copper cable green in colour as earth continuity wire connecting to common earth point terminated in and including 1.6mm thick mild steel sunken terminal box of suitable size with 3mm thick hylam sheet top cover fixed with suitable size of brass screws suitable sizes cadmium plated iron screws and washers etc.for mounting switches, sockets, regulators etc complete for one light/fan/bell/buzzer point controlled by one ,one way switches complete all as specified and as directed.
All as per Item No.129 above but for One 2/3 pin socket outlet 5/6Amps on independent board
All as per Item No.129 above but for One 2/3 pin socket outlet 5/6 Amps on the same board with other switches.
All as per Item No.129 above but for one switch socket combination 15/16 Amps on independent board with cable 2.5 sq mm size and earth wire 2.5 sqmm
All as per Item No.129 above but for one switch socket combination 15/16 Amps on independent board with cable 4 sq mm size and earth wire 4 sqmm
M&L for concealed point wiring with two runs of FRLSH PVC insulated unsheathed, 1100 V grade cable multi stranded copper conductor of size 1.5 sqmm and one single core FRLSH PVC insulated unsheathed stranded copper conductor of size 1.50 sqmm green in colour as earth lead, drawing through in and including PVC rigid conduit of size not less than 20mm, with all fittings & accessories including provn of MS sunk terminal box of appropriate size suitable for switch fixed flush to wall for mounting switch, sockets, fan regulators etc with 3mm thick hylum sheet top cover with screws & cup washers including cutting chases and making good by using cement mortar 1:4 complete for one light / fan point / call bell complete.
All as per Item No.134 above but for One 2/3 pin socket outlet 5/6Amps on independent board
All as per Item No.134 above but for One 2/3 pin socket outlet 5/6 Amps on the same board with other switches.
All as per Item No.134 above but for one switch socket combination 15/16 Amps on independent board with cable 2.5 sq mm size and earth wire 2.5 sqmm
All as per Item No.134 above but for one switch socket combination 15/16 Amps on independent board with cable 4 sq mm size and earth wire 4 sqmm
S&F Switch piano, flush type, single pole, one way switch 5 Amps. (Note :- switches to be used both for new point wiring and old switch boxes of existing wiring)
S&F Socket outlet 5 in 1, 5 Amp flush type universal, 240 volts, complete all as specified all as directed.
S&F Switch socket combination 3/5 pin, 2 in 1, 5 Amps flush type, 240 volts, complete all as specified all as directed. .
S&F Switch socket combination multipurpose 3/5 pin, 5 A /16 Amps, 5 in 1, flush type, 240 volts, complete all as specified all as directed. .
S&F for ceiling rose, 3 phase/ PVC/ polycarbonate, isolated body bearing ISI marked and including PVC box complete all as specified and as directed.
S&F electronic step regulator (speed regulation in 5 steps) suitable for ceiling fan 1200 sweep/1400 mm, 120 Watt complete all as specified and directed.
S&F for lamp holder PVC/Polycarbonate type with back plate suitable for batten fittings including fixing for one 9 Watt LED Lamp complete all as specified and as directed.
S&F LED lights fitting 1x 18/20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete.
S&F LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed.
S&F LED pendant type warm white wooden light adjustable hanging ceiling light of 10 Watt in acrylic shade including all equipments needed for installation complete all as specified and as directed.
S&F MCB distrubution board TPN 4 way double door, sheet steel, phosphatised, powder coated with 200 amps bus-bar, neutral link, earth bar and din rail, 415 V, complete all as specified and directed. by Engineer-in-charge.
S&F MCB distrubution board SPN 8 way double door, sheet steel, phosphatised,powder coated with 200 amps bus-bar, neutral link,earth bar and din rail 240 V , complete all as specified and directed. by Engineer-in-charge.
S&F MCB distrubution board SPN 4 way double door, sheet steel, phosphatised, powder coated with 200 amps bus-bar, neutral link, earth bar and din rail 240 V , complete all as specified and directed. by Engineer-in-charge.
S&F MCB TPN, 415 volts 40- 63 Amps, 16 KA breaking capacity, C series, adjustable thermal and adjustable magnetic
S&F MCB Single pole, 240 volts 6 to 32 Amps 10 KA rupturing capacity, C series complete all as specified and directed by Engr-in-charge.
S&F MCB Single pole and neutral, 40 Amps, 240 volts 10 KA rupturing capacity, C series complete all as specified and directed by Engr-in-charge.
S&F MCB Single pole and neutral, 6 to 32 Amps, 240 volts 10 KA rupturing capacity, C series complete all as specified and directed by Engr-in-charge.
M&L for sub main wiring with two run of 6 Sqmm (Nominal area) single core cable PVC insulated, multistranded, unsheathed, copper conductor cables (FRLSH), 1100 Volts grade drawn through PVC Conduit of suitable size, fixed on surface of wall/ceiling etc with all necessary fittings and accessories and one run of 6 Sqmm (nominal area) single core, PVC insulated, multistranded, unsheathed, copper conductor (FRLSH) as earth wire and duly connected to common earth point including taking down old unserviceable complete all as specified and as directed. Note : (a) PVC Casing-caping/conduit, two run wiring cables and one run of earth wire will be measured as one length (b) All incoming and outgoing cable shall be connected by using proper lugs & sockets.
M&L for sub main wiring with two run of 6 Sqmm (Nominal area) single core cable PVC insulated, multistranded, unsheathed, copper conductor cables (FRLSH), 1100 Volts grade drawn through PVC casing-caping of suitable size, fixed on surface of wall/ceiling etc with all necessary fittings and accessories and one run of 6 Sqmm (nominal area) single core, PVC insulated, multistranded, unsheathed, copper conductor (FRLSH) as earth wire and duly connected to common earth point including taking down old unserviceable complete all as specified and as directed. Note : (a) PVC Casing-caping/conduit, two run wiring cables and one run of earth wire will be measured as one length (b) All incoming and outgoing cable shall be connected by using proper lugs & sockets.
M&L for clear sand cushioning with dry clean sand for protection of cable, 15cm below the cable and 8cm above the cable, complete all as specified and as directed. Note : Punned thickness shall be measured for payments.
Supply and laying well burnt bricks, sub class 'B' bricks laid breath wise across the length of cable in trenches for protection of UG cables complete all as specified and directed.
Boring of holes horizontal for laying not less than 80/50/40/32mm pipe (minimum depth 0.75 mtr from top level) under the road pavement, hard standing using trenchless technology complete all as specified and as directed. Note : cost of accessories required for making hole/bore deemed to be included in the quoted rate.
Supply, laying, jointing, commissioning and testing cross-linked polyethylene (XLPE) insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 Volt grade with stranded aluminium conductor of size 35 sq.mm 3.5 Core, ISI marked as per IS-7098 (Part-I) 1988 including cable glands, lugs etc to suit the cable size and to be laid in trenches, under floors, through GI pipe complete including taking down all as specified and as directed. Note : (1) Pipes shall be measured and paid separately under relevant items. (2) Excavation and earth work shall be measured and paid separately. complate all as specified and directed.
Supply, laying, jointing, commissioning and testing cross-linked polyethylene (XLPE) insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 Volt grade with stranded aluminium conductor of size 10 sq.mm 2 core, ISI marked as per IS-7098 (Part-I) 1988 including cable glands, lugs etc to suit the cable size and to be laid in trenches, under floors, through GI pipe incl taking down old unserviceable one complete all as specified and as directed. Note : (1) Pipes shall be measured and paid separately under relevant items. (2) Excavation and earth work shall be measured and paid separately. complate all as specified and directed.
M&L for GI pipe light grade with all fittings complete grouted in ground all as specified for 32mm bore of pipe laid in trenches/fixed with poles/laid in road/plinth/floor for protection of cable including taking down old unserviceable complete all as specified and directed.
S&F in repairs 35/40 Watt LED building security light new generation energy saving and environmental friendly long life LED street light made up of pressure die cast aluminium housing with high power LED as lighting source and lens embeded PC cover having Bottom Opening seperate driver compartment with IP66 protection and impact resistance of IK08. including all fixing arrangement and taking down old light fittings of any type complete all as specified and as directed.
S&F exhaust fan AC, single phase, 230/240 V, of size 300 mm seeep heavy duty steel/aluminium metal body including cutting of circular hole at any type of wall , grouting 04 Nos 100mm long 12mm dia stud bolt including making good the distrubed surfaces of wall and colour wash to match as per existing colour with all connecting arrangements complete all as specified and directed.
S&F for street light bracket arm of length not less than 1.5 m made out of GI tubing, 40 mm bore, light grade fixed to pole, etc with suitable size flat iron clamp, nuts, bolts including painting with two coats of aluminium paint over a coat of red oxide, zinc chrome primer on steel surfaces complete all as specified and as directed.
M&L for earthing complete with GI earth plate electrode 600mm x 600mm x 6 mm thick burried directly in ground vertically to a depth not less than 2.25m below ground level with the top edge of earth plate at depth not less than 1.5m below ground level connected to galvanised earth lead wire 4.0 mm dia by means of bolts, nuts, check nuts and washers protected by 15mm bore light grade GI pipe, funnel with 20mm bore GI medium grade pipe for watering, wire mesh, including concrete pit in PCC (1:3:6) type C-1, pre-cast RCC 1:2:4 type B-1 cover slab of size 350x350x50mm reinforced with 8mm dia TMT steel bars @ 15cm centre to centre in both direction and 10mm dia MS handle of suitable size, charcoal or coke and salt in alternative layers, necessary earth work in soft/loose soil all as shown in Electrical Plate No 3 of MES Schedule Part I and testing the base in which pit cover rests made up of MS angle iron (Frame) complete all specified and directed.
M&L for earthing complete with GI earth plate electrode 600mm x 600mm x 6 mm thick burried directly in ground vertically to a depth not less than 2.25m below ground level with the top edge of earth plate at depth not less than 1.5m below ground level connected to galvanised earth lead wire 4.0 mm dia by means of bolts, nuts, check nuts and washers protected by 15mm bore light grade GI pipe, funnel with 20mm bore GI medium grade pipe for watering, wire mesh, including concrete pit in PCC (1:3:6) type C-1, pre-cast RCC 1:2:4 type B-1 cover slab of size 350x350x50mm reinforced with 8mm dia TMT steel bars @ 15cm centre to centre in both direction and 10mm dia MS handle of suitable size, charcoal or coke and salt in alternative layers, necessary earth work in soft/loose soil all as shown in Electrical Plate No 3 of MES Schedule Part I and testing the base in which pit cover rests made up of MS angle iron (Frame) including taking down complete all as specified and directed.
Construction House (BID ID -3357679)
M/s GANDHESWAR PHUKAN (BID ID -3357947)
M/s Kanchan Enterprise (BID ID -3357774)
PATKAI ENTERPRISE (BID ID -3357501)
M/S AUTOMOTIVE WORLD (BID ID -3357765)
jitendra narayan goswami (BID ID -3357676)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .