Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹64.5 LAccepted-AOC R O KHONI PO HATKOTI TEHSIL JUBBAL DISTT SHIMLA H P | SHIMLA | HIMACHAL PRADESH | 170009 | L1 | Accepted-AOC L1 | |
| 2 | L2₹64.5 L+₹716.45 (0.01%)Rejected-AOC S O SH JAI RAM VILLAGE JAGUNI TEHSIL RAMPUR DANSA DIST SHIMLA HP 172001 | SHIMLA | HIMACHAL PRADESH | 172001 | L2 | Rejected-AOC L2 | |
| 3 | L3₹67.3 L+₹2.8 L (4.36%)Rejected-AOC | L3 | Rejected-AOC L3 | |
| 4 | L4₹70.0 L+₹5.5 L (8.60%)Rejected-AOC | L4 | Rejected-AOC L4 | |
| 5 | L5₹72.6 L+₹8.1 L (12.6%)Rejected-AOC | L5 | Rejected-AOC L5 |
Tender Value
₹71.6 L
EMD Value
₹1.0 L
Closing Date
4 Aug 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer
HPPWD Jubbal
SH C/O Building portion including site development,W.S. and S.I. works.
2021_PWD_50213_1
PW-JD/E-Tender/2021-22-2964 -66 DT.13.07.2021
Open Tender
Civil Works - Buildings
Item Rate
540 days
Jubbal
Please refer Tender documents.
13 documents required · 13 mandatory
₹2,000
₹1.0 L
Yes
15 Sept 2021
22 Jul 2021
5 Aug 2021
22 Jul 2021
4 Aug 2021
22 Jul 2021
120 days
Amount
Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas with in all lead and lifts including getting out and disposal of excavated earth lead upto any lead lifts/CPWD specifications as directed by Engineer-in-charge.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level 1:4:8 (1 Cement : 4 coarse sand) : 8 graded stone aggregate 40 mm nominal size) including all leads and lifts, as per HPPWD/CPWD specification of 1990 Volume-I, as directed by the Engineer-In-Charge.
Centering and shuttering including strutting, propping etc. and removal of form for : including all leads and lifts, as per HPPWD/CPWD specification of 1990 Volume-I, as directed by the Engineer-In-Charge.
Foundation, footings basis of columns etc. and mass concrete including all leads and lifts as directed by the Engineer-In-Charge.
Beams, cantilever, girders and lintel as directed by the Engineer-In-Charge..
Columns, pillars, posts and struts as directed by the Engineer-In-Charge..
Suspended floors, roofs, landings, balconies and access platform as directed by the Engineer-In-Charge.
Edges of slabs and breaks in floors and walls:Under 20 cm. wide as directed by the Engineer-In-Charge.
Stair cases with sloping or stepped soffits excluding landing as directed by the Engineer-In-Charge.
Concrete work 1:1.5:3 (1 cement : 1.5 sand :3 graded stone aggregate 20mm nominal size) and curing complete excluding cost of form work and reinforcement for reinforced concrete work in : including all leads and lifts, as per HPPWD/CPWD specification of 1990 Volume-I, as directed by the Engineer-In-Charge.
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : including all leads and lifts, as per HPPWD/CPWD specification of 1990 Volume-I, as directed by the Engineer-In-Charge.
Lintels, beams girders bressumers and cantilevers upto floor two level. including all leads and lifts, as per HPPWD/CPWD specification of 1990 Volume-I, as directed by the Engineer-In-Charge.
Column, pillars, posts and struts upto floor two level. including all leads and lifts, as per HPPWD/CPWD specification of 1990 Volume-I, as directed by the Engineer-In-Charge.
suspended floor roofs landing and shelves and there support etc. including all leads and lifts, as per HPPWD/CPWD specification of 1990 Volume-I, as directed by the Engineer-In-Charge.
stair cases ( except spiral stair case ) Excluding landing but encluding preparing the surface upto floor two level. including all leads and lifts, as per HPPWD/CPWD specification of 1990 Volume-I, as directed by the Engineer-In-Charge.
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a all lead all kind of soil including all leads and lifts, as per HPPWD/CPWD specification of 1990 volume-I as directed by the Engineer-In-Charge
Earth work in surface excavation all width on plan including getting out and disposal of excavated earth upto any lead and liftsas as per HPPWD/CPWD specification of 1990 volume-I as directed by Engineer-in- Charge:
Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing:1:5:10 (1 cement : 5 coarse sand) : 10 graded stone aggregate 40 mm nominal size). including all leads and lifts, as per HPPWD/CPWD specification of 1990 volume-I as directed by the Engineer-In-Charge
Providing weapholes in brick masonry / stone masonry /plain reinforced concrete abutment, wing wall, return wall with 100 mm dia PVC pipe extending through the full with of the structures with slop of 1(v):20(H) towards drawing face complete as per drawing and technical specification clauses 614, 709, 1204.3.7 including all leads and lifts, as per HPPWD/CPWD specification of 1990 volume-I as directed by the Engineer-In-Charge
Backfilling with Granular material behind abutment, wing wall and return wall complete as per drawings & technical specification Clause 1204.3.8 including all leads and lifts, as per HPPWD/CPWD specification of 1990 volume-I or as directed by the Engineer-In-Charge
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level Mild/ Tor steel and Medium Tensile steel bars. including all leads and lifts, as per HPPWD/CPWD specification of 1990 Volume-I, as directed by the Engineer-In-Charge.
Providing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required0.63 mm thick with zinc coating not less than 275 gm/ m² including all leads and lifts, as per HPPWD, specification of 1990 Volume-I, as directed by the Engineer-In-Charge.
Providing ridges or hips of width 60 cm overall width plain G.S. sheet fixed with polymer coated J or L hooks, bolts and nuts 8 mm dia G.I. limpet and bitumen washers complete0.63 mm thick with zinc coating not less than 275 gm/m² including all leads and lifts, as per HPPWD/CPWD specification of 1990 Volume-I, as directed by the Engineer-In-Charge.
Providing valleys of 90 cm wide overall in plain G.S. sheet fixed with polymer coated J, or L hooks, bolts and nuts 8 mm dia G.I. limpet and bitumen washers complete :1.60 mm thick with zinc coating not less than 350 gm/m² including all leads and lifts, as per HPPWD/CPWD specification of 1990 Volume-I, as directed by the Engineer-In-Charge.
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete including all leads and lifts, as per HPPWD/CPWD specification of 1990 Volume-I, as directed by the Engineer-In-Charge.
Providing and fixing 15 cm wide, 45 cm overall semicircular plain G.S. sheet gutter with iron brackets 40x3mm size, bolts, nuts and washers etc., including making necessary connections with rain water pipes complete. including all leads and lifts, as per HPPWD/CPWD specification of 1990 Volume-I, as directed by the Engineer-In-Charge.
Providing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.1.00 mm thick with zinc coating not less than 275 gm/m² including all leads and lifts, as per HPPWDCPWD specification of 1990 Volume-I, as directed by the Engineer-In-Charge.
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand) including all leads and lifts, as per HPPWD/CPWD specification of 1990 Volume-I, as directed by the Engineer-In-Charge.
Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level.Cement mortar 1:4 (1 cement :4 coarse sand) including all leads and lifts, as per HPPWD/CPWD specification of 1990 Volume-I, as directed by the Engineer-In-Charge.
15 mm cement plaster on fair side of single or half brick wall of mix: 1:6 (1 cement: 6 coarse sand) including all leads and lifts, as per HPPWD/CPWD specification of 1990 Volume-I, as directed by the Engineer-In-Charge.
15 mm cement plaster on rough side of single or half brick wall of mix: 1:6 (1 cement: 6 coarse sand) including all leads and lifts, as per HPPWD/CPWD specification of 1990 Volume-I, as directed by the Engineer-In-Charge.
Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in under floor, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.
Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 25mm thick including all leads and lifts, as per HPPWD/CPWD specification of 1990 Volume-I, as directed by the Engineer-In-Charge
6mm Cement plaster to ceiling In Cement mortar 1:3(1 Cement:3 Sand) including all leads and lifts, as per HPPWD/CPWD specification of 1990 Volume-I, as directed by the Engineer-In-Charge.
Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters:35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws including all leads and lifts, as per HPPWD/CPWD specification of 1990 Volume-I, as directed by the Engineer-In-Charge.
Providing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.0.63 mm thick with zinc coating not less than 275 gm/ m² including all leads and lifts, as per HPPWD/CPWD specification of 1990 Volume-I, as directed by the Engineer-In-Charge.
Providing and fixing wire gauge shutters using galvanized M.S. wire gauge of average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm, for doors, windows and clerestory windows with hinges and necessary screws :with ISI marked M.S. pressed butt hinges bright finished of required size Second class teak wood including all leads and lifts, as per HPPWD/CPWD specification of 1990 Volume-I, as directed by the Engineer-In-Charge.
Fixing standard steel glazed doors, windows and ventilators in walls, including fixing of float glass panes with glazing clips and special metal- sash putty of approved make, or metal beading with screws, (only steel windows, glass panes cut to size and glazing clips or metal beading with screws, shall be supplied by department free of costFixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) including all leads and lifts, as per HPPWD/CPWD specification of 1990 Volume-I, as directed by the Engineer-In-Charge.
Fixed steel windows
Side hung windows
Steel ventilators Top hung ventilators
Providing and fixing oxidized M.S. sliding door bolts with nuts and screws etc. complete. including all leads and lifts, as per HPPWD/CPWD specification of 1990 Volume-I, as directed by the Engineer-In-Charge.
Providing and fixing oxidised M.S. tower bolts (barrel type) with necessary screws etc. complete. including all leads and lifts, as per HPPWD/CPWD specification of 1990 Volume-I, as directed by the Engineer-In-Charge.
Providing and fixing oxidized M.S. handles with the necessary screws etc. complete. including all leads and lifts, as per HPPWD/CPWD specification of 1990 Volume-I, as directed by the Engineer-In-Charge.
Providing and fixing oxidized M.S. hooks and eyes including all leads and lifts, as per HPPWD/CPWD specification of 1990 Volume-I, as directed by the Engineer-In-Charge.
Window 150 mm
Providing and fixing cup board shutters 25 mm thick, with Pre-laminated flat pressed three layer particle board or graded wood particle board IS: 12823 marked, exterior grade (Grade l Type ll), having one side decorative lamination and other side balancing lamination, including IInd class teak wood lipping of 25 mm wide x12 mm thick with necessary screws and bright finished stainless steel piano hinges, complete including all leads and lifts, as per HPPWD/CPWD specification of 1990 Volume-I,as per direction of the Engineer-in-Charge
Providing and fixing cup board shutters with 25 mm thick veneered particle board IS : 3097 marked, exterior grade (Grade I), of approved make, including IInd class teak wood lipping of 25 mm wide x 12 mm thick with necessary screws and bright finished stainless steel piano hinges, With decorative veneering on one side and commercial veneering on other side including all leads and lifts, as per HPPWD/CPWD specification of 1990 Volume-I, as directed by the Engineer-In-Charge.
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 110mm dia including all leads and lifts, as per HPPWD/CPWD specification of 1990 Volume-I, as directed by the Engineer-In-Charge.
Providing, fixing and embedding sand cast iron accessories for rain water pipes in the masonry surrounded with 12 mm thick cement mortar of the same mix, as that of masonry (lead caulking will be paid for separately):150mm dia including all leads and lifts, as per HPPWD/CPWD specification of 1990 Volume-I, as directed by the Engineer-In-Charge.
Precast terrazo tiles 22 mm thick with graded marble chips of size upto 12 mm, laid in floors, and landings, jointed with neat cement slurry mixed with pigment to match the shade of the tiles, including rubbing and polishing complete, on 20 mm thick bed of cement mortar 1:4 (1 cement:4 coarse sand)Medium shade pigment using 50% white cement and 50% ordinary cement including all leads and lifts, as per HPPWD/CPWD specification of 1990 Volume-I, as directed by the Engineer-In-Charge.
Precast terrazo tiles 22 mm thick with graded marble chips of sizes upto 12 mm, in skirting and risers of steps not exceeding 30 cm in height, on 12 mm thick cement plaster 1:3 (1 cement : 3 coarse sand), jointed with neat cement slurry mixed with pigment to match the shade of the tiles, including rubbing and polishing complete with tiles of :Medium shades pigment using 50% white cement and 50% ordinary cement including all leads and lifts, as per HPPWD/CPWD specification of 1990 Volume-I, as directed by the Engineer-In-Charge.
Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 25mm thick including all leads and lifts, as per HPPWD/CPWD specification of 1990 Volume-I, as directed by the Engineer-In-Charge.
Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete including all leads and lifts, as per HPPWD/CPWD specification of 1990 Volume-I, as directed by the Engineer-In-Charge.
Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. complete 600x600 mm including all leads and lifts, as per HPPWD/CPWD specification of 1990 Volume-I, as directed by the Engineer-In-Charge
Providing and laying Vitrified tiles in different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS: 15622, of approved brand & manufacturer, in all colours and shade, in skirting, riser of steps, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS: 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately). 600x600 mm including all leads and lifts, as per HPPWD/CPWD specification of 1990 Volume-I, as directed by the Engineer-In-Charge
Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. complete 600x600 mm including all leads and lifts, as per HPPWD/CPWD specification of 1990 Volume-I, as directed by the Engineer-In-Charge.
Providing and laying Vitrified tiles in different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS: 15622, of approved brand & manufacturer, in all colours and shade, in skirting, riser of steps, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS: 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately). 600x600 mm including all leads and lifts, as per HPPWD/CPWD specification of 1990 Volume-I, as directed by the Engineer-In-Charge.
Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-inCharge.60mm thick cement concrete paver block of M-35 grade with approved colour, design & pattern. including all leads and lifts, as per HPPWD/CPWD specification of 1990 Volume-I, as directed by the Engineer-In-Charge.
Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and including all leads and lifts, as per HPPWD/CPWD specification of 1990 Volume-I, as directed by the Engineer-in-Charge
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. including all leads and lifts, as per HPPWD/CPWD specification of 1990 Volume-I, as directed by the Engineer-In-Charge.
Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour Two coats including all leads and lifts, as per HPPWD/CPWD specification of 1990 Volume-I, as directed by the Engineer-In-Charge.
Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade New work (two or more coats) over and including water thinnable priming coat with cement primer including all leads and lifts, as per HPPWD, specification of 1990 Volume-I, as directed by the Engineer-In-Charge.
Applying priming coat over new wood and wood based surfaces With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including all leads and lifts, as per HPPWD/CPWD specification of 1990 Volume-I, as directed by the Engineer-In-Charge.
Providing and applying two coats of fire retardant paint on cleaned wood / ply surface @ 3.5 sqm per litre per coat including preparation of base surface as per recommendations of manufacturer to make the surface fire retardant. including all leads and lifts, as per HPPWD, specification of 1990 Volume-I, as directed by the Engineer-In-Charge.
13.61 ) Painting with synthetic enamel paint of approved brand and manufacture to give an even shadeTwo or more coats on new work including all leads and lifts, as per HPPWD/CPWD specification of 1990 Volume-I, as directed by the Engineer-In-Charge.
8.29) providing and fixing 4mm thick coir veneer board, ISI marked IS : 14842, plain lining with necessary screws, priming coat on unexposed surface etc., complete. including all leads and lifts, as per HPPWD/CPWD specification of 1990 Volume-I, as directed by the Engineer-In-Charge
Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shuttersteel work in single section, fixed with or 10.6.1 80x1.25 mm M.S. laths with 1.25 mm thick top cover including all leads and lifts, as per HPPWD/CPWD specification of 1990 Volume-I, as directed by the Engineer-In-Charge
Providing and fixing ball bearingfor rolling shutters
Providing under layer for plinth protection of 75mm thick (unconsolidated) bed dry brick/stone aggregated 40mm nominal size with rammed and consolidated and grouted with fine sand including preparation of ground including all leads and lifts, as per HPPWD/CPWD specification of 1990 Volume-I, as directed by the Engineer-In-Charge.
Making plinth protection 50 mm thick of cement concrete 1:3:6 (1 Cement : 3 Sand : 6 Graded stone aggregated 20mm nominal size) All works upto plinth level including all leads and lifts, as per HPPWD/CPWD specification of 1990 Volume-I, as directed by the Engineer-In-Charge.
10.30 ) Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2 mm and braced with flat iron diagonals 20x5 mm size, with top and bottom rail of T-iron 40x40x6 mm, with 40 mm dia steel pulleys, complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of approved steel prime including all leads and lifts, as per HPPWD, specification of 1990 Volume-I, as directed by the Engineer-In-Charge.
17.2 ) Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required W.C. pan with ISI marked white solid plastic seat and lid including all leads and lifts, as per HPPWD/CPWD specification of 1990 Volume-I, as directed by the Engineer-In-Charge.
Providing and fixing P.V.C. low level flushing cistern with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete10 litre capacity - White including all leads and lifts, as per HPPWD/CPWD specification of 1990 Volume-I, as directed by the Engineer-In-Charge.
Providing and fixing solid plastic seat with lid for pedestal type W.C. pan completeWhite solid plastic seat with lid including all leads and lifts, as per HPPWD/CPWD specification of 1990 Volume-I, as directed by the Engineer-In-Charge.
Providing and fixing white vitreous china squatting plate urinal with integral rim longitudinal flush pipe. including all leads and lifts, as per HPPWD/CPWD specification of 1990 Volume-I, as directed by the Engineer-In-Charge.
Providing and fixing controlled flush, low level cistern made of vitreous china with all fittings complete 10 litre (full flush) capacity-white including all leads and lifts, as per HPPWD/CPWD specification of 1990 Volume-I, as directed by the Engineer-In-Charge.
Providing and fixing G.I. inlet connection for flush pipe connecting with W.C. pan. including all leads and lifts, as per HPPWD/CPWD specification of 1990 Volume-I, as directed by the Engineer-In-Charge.
Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mix including all leads and lifts, as per HPPWD/CPWD specification of 1990 Volume-I, as directed by the Engineer-In-Charge.
Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings including all leads and lifts, as per HPPWD/CPWD specification of 1990 Volume-I, as directed by the Engineer-In-Charge.
Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : 610x510 mm bowl depth 200 including all leads and lifts, as per HPPWD/CPWD specification of 1990 Volume-I, as directed by the Engineer-In-Charge.
Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete 32 mm dia Flexible pipe including all leads and lifts, as per HPPWD/CPWD specification of 1990 Volume-I, as directed by the Engineer-In-Charge.
C.P. Brass union 40mm dia including all leads and lifts, as per HPPWD/CPWD specification of 1990 Volume-I, as directed by the Engineer-In-Charge.
Providing and fixing 100mm sand cast iron grating for gully floor or nahni trap including all leads and lifts, as per HPPWD/CPWD specification of 1990 Volume-I, as directed by the Engineer-In-Charge.
Providing and fixing 600mm x450mm bevalled edge mirror of superior glass mounted on 6mm thick A. C. sheet or ply wood sheet and fixed to wooden plug with C.P. brass Screw and washers including all leads and lifts, as per HPPWD/CPWD specification of 1990 Volume-I, as directed by the Engineer-In-Charge.
Providing and fixing C.P Brass towel rail complete with C.P Brass brackets fixed to wooden plugs with C.P brass screws 750mmx20mm C.P Brass towel rail including all leads and lifts, as per HPPWD/CPWD specification of 1990 Volume-I, as directed by the Engineer-In-Charge.
Providing and fixing 600x120x5 mm glass shelf with edges round off, supported on anodised aluminium angle frame with C.P. brass brackets and guard rail complete fixed with 40 mm long screws, rawl plugs etc., complete including all leads and lifts, as per HPPWD/CPWD specification of 1990 Volume-I, as directed by the Engineer-In-Charge.
Providing and fixing toilet paper holder (i) C.P Bras including all leads and lifts, as per HPPWD/CPWD specification of 1990 Volume-I, as directed by the Engineer-In-Charge.
Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms. including all leads and lifts, as per HPPWD/CPWD specification of 1990 Volume-I, as directed by the Engineer-In-Charge.
Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 gms. including all leads and lifts, as per HPPWD/CPWD specification of 1990 Volume-I, as directed by the Engineer-In-Charge.
Providing and fixing stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in-charge and finished smoothWhite Agaria Marble Stone including all leads and lifts, as per HPPWD/CPWD specification of 1990 Volume-I, as directed by the Engineer-In-Charge.
Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 gms. including all leads and lifts, as per HPPWD/CPWD specification of 1990 Volume-I, as directed by the Engineer-In-Charge.
Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931. including all leads and lifts, as per HPPWD/CPWD specification of 1990 Volume-I, as directed by the Engineer-In-Charge. 15mm dia
Piller tap 15 mm dia including all leads and lifts, as per HPPWD/CPWD specification of 1990 Volume-I, as directed by the Engineer-In-Charge.
Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931.15 mm nominal bore including all leads and lifts, as per HPPWD/CPWD specification of 1990 Volume-I, as directed by the Engineer-In-Charge.
Providing and fixing unplasticised P.V.C. connection pipe with PTMT Nuts, collar and bush of approved quality and colour 15mm nominal bore 45 cm long including all leads and lifts, as per HPPWD/CPWD specification of 1990 Volume-I, as directed by the Engineer-In-Charge.
Providing and fixing brass full way value with wheel:25mm nominal bore. including all leads and lifts, as per HPPWD, specification of 1990 Volume-I, as directed by the Engineer-In-Charge.
Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. including all leads and lifts, as per HPPWD/CPWD specification of 1990 Volume-I, as directed by the Engineer-In-Charge.
Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors :Sand cast iron S&S as per IS: 3989 including all leads and lifts, as per HPPWD/CPWD specification of 1990 Volume-I, as directed by the Engineer-In-Charge.
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.Door Bend 87.5 Digree including all leads and lifts, as per HPPWD/CPWDspecification of 1990 Volume-I, as directed by the Engineer-In-Charge.
110mm dia
75mm dia
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. coupler including all leads and lifts, as per HPPWD/CPWD specification of 1990 Volume-I, as directed by the Engineer-In-Charge.
110mm dia
75mm dia
Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete including all leads and lifts, as per HPPWD/CPWD specification of 1990 Volume-I, as directed by the Engineer-In-Charge. 1) 110 mm dia
2) 75mm dia
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. including all leads and lifts, as per HPPWD/CPWD specification of 1990 Volume-I, as directed by the Engineer-In-Charge. 1) 110mm dia
2)75 mm dia
Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make including all leads and lifts, as per HPPWD/CPWD specification of 1990 Volume-I, as directed by the Engineer-In-Charge.
Providing and fixing Polyethelene-AluminiumPolyethelene PE-AL- PE Composite Pressure Pipes conforming to IS - 15450, U.V. stabilized with carbon black having thermal stability for hot & cold water supply, capable to withstand temperature up to 80°C, including all special fittings of composite material (engineering plastic blend and brass inserts wherever required) e.g. elbows, tees, reducers, couplers & connectors etc., with clamps at 1.00 metre spacing. This includes testing of joints complete including all leads and lifts, as per HPPWD/CPWD specification of 1990 Volume-I, as directed by the Engineer-In-Charge.
Rakesh Negi
HAPPINDER SOOD
Harsh chauhan
Chaten Chauhan
JANARDHAN HAUTA
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .