GE GOLCONDA
GE GOLCONDA LANGER HOUSE OPP MILITARY HOSPITAL HYDERABAD TELANGANA-500 008
SPL REPAIRS TO SUNKEN FLOORS OF TOILET BLOCKS AT VARIOUS LOCATION IN BLDG NO. 237 and 240, PROVN OF UG SUMP 1.0 LAKH LTRS AND OHT 20000 LTRS CAPACITY NEAR STP AND PROVN OF 1 TOILET BLOCK AT PT GROUND UNDER AGE B/R-I OF GE GOLCONDA
2022_MES_559831_1
8636/E8
Open Tender
Civil Works
Item Rate
180 days
HYDERABAD
As Per Tender
9 documents required · 9 mandatory
₹500
GE GOLCONDA
₹84,000
Yes
25 Nov 2022
26 Oct 2022
25 Nov 2022
26 Oct 2022
23 Nov 2022
9 Nov 2022
Amount
Taking down chowkats or frames with shutters (without taking off shutter from the frames) n.exc. 1.5 sqm complete all as specified and directed.
S&F Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, in opening of brick wall complete all as specified and directed.
S&F of factory made solid panel PVC door shutter 30mm thick (Style) consisting of frame made out of M.S tubes for top and bottom rails. M.S frame shall be covered with heat moulded plain colour PVC 'C' channel moulded plain colour PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail and bottom rail on either side and as gap insert for top rail and bottom rail; Panelling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, supplying and fixing in the frame at site complete all as specified and directed.
S&F for 100 mm long extruded Aluminium alloy butt hinges fixed to PVC door shutter.
S&F for 150mm long aluminium anodized barrel tower bolts of extruded section.
S&F for 125 mm long alluminium alloy anodized handles fabricated type
S&F in repairs Vitreous China squatting pan , "Orissa" pattern size 580 X 440 mm white with intgrel footrest (excluding flushing cistern & flush pipe) including 110 dia PVC SWR 'P' or 'S' trap complete including provision of cement concrete all as specified and directed.
S&F vitreous china wash basin, white, flat back size 550 x 400mm including 01 Nos cast copper alloy 15mm CP pillar tap, 01 Nos 32mm waste coupling and pipe, one pair of MS bracket, cutting for and pinning in ends of brackets complete all as specified and directed.
S & F in repair vitreous china bowl urinal flat back size of 465 x 355 x 265mm white (minimum) with grating and union for discharge pipe (excluding flushing cistern & flush pipe) but excluding waste pipe, complete including providing & fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with screws, pointing around urinal back in cement complete all as specified and directed.
S&F in repair PVC valveless syphonic action type flushing cistern 10 lit capacity low level white with inlet, ball valve, float and handle including brackets and 32mm PVC flush pipe flush pipe complete all as specified and directed
S & F PVC connections 15 mm size with PTMT nuts of length 450 mm complete all as specified and directed
S&F in repair for PVC waste pipe for urinal/WHB with complete fitting etc 38mm dia 60mm long complete all as specified and directed
S&F in repair 15 mm dia fancy type bib taps cast copper alloy chromium plated type screwed down, screwed for iron pipe or for brass ferrule complete all as specifie and diredted.
S&F in repairs 15 mm dia Brass Stop valves/angle cock chromium plated fancy type, screwed down, high pressure, with crutch or butterfly hadle, screwed both ends for iron pipe or for unions complete all as specified and directed
S&F in repairs concealed stop cock, fancy type 15mm dia, chromium plated with long shank and cup (concealed type) complete all as specified and directed
Supply and lay of CPVC pipes, Schedule SDR-11 & plain CPVC SDR 11 fittings for sizes (outer dia) 20 mm including all fittings and fixed with solvents as per manufacturers recommendations in the walls/ ceiling or laying in floors, including taking down steel tubing complete all as specified and directed
All as per Item No. 16 but 25mm dia
All as per Item No. 16 but 50mm dia
Supply and Fix CPVC brass elbow for 20 mm outer dia pipe complete all as specied and directed.
Supply and Fix CPVC Male brass threaded adaptor for 50 mm outer dia size (MTA/MBTA) complete all as specied and directed.
Supply and Fix CPVC Ball valve for 50 mm outer dia pipe complete all as specied and directed.
S & F Rotational moulded polyethylene water storage tanks double layer (cylindrical vertical with closed top ) of 1000 ltr capacity hoisted and fixed in position including dismantling of old unserviceable tank complete all as specified and directed.
S&F in repair PVC ball valve 25 mm dia high pressure of PTMT with epoxy coated aluminium rod and high density plasic ball screwed for iron pipe and fixed . (minimum weight 25 mm- 455 gms )
S&F in repair 50mm bore dia Gun metal Gate valve with iron wheel head screwed both ends for iron pipe or for union, complete all as specified and directed.
S & F PVC( SWR ) pipes 110mm dia single socketed , in any lenth with rubber ring joints as rainwater, soil waste and vent pipe (with all fittings) fixed to wall or laid in trenches incl taking down complete all as specified and directed.
S&F PVC (SWR) bends any radius 110 mm dia completee all as specified and directed
S&F PVC (SWR) bends with access door any radius 110mm bore in repairs
S&F PVC (SWR) junction single (single T) equal or unequal with access door of bore 110mm
S&F PVC (SWR) junction double (double Y) equal or unequal with access door of bore 110mm
S&F PVC(SWR) vent cowl 110mm bore
S & F PVC( SWR ) pipes 75mm dia single socketed , in any lenth with rubber ring joints as rainwater, soil waste and vent pipe (with all fittings) fixed to wall or laid in trenches incl taking down complete all as specified and directed.
S&F PVC (SWR) floor trap 75mm dia outlet, plain with grating including jointing with solvent cement in repairs
S&F PVC (SWR) bends any radius 75 mm dia completee all as specified.
S&F PVC (SWR) bends with access door any radius 75 mm dia completee all as specified.
S&F PVC (SWR) junction double (double Y) equal or unequal with access door of bore 75mm
S&F PVC (SWR) junction double (double T) equal or unequal with access door of bore 75mm
S & F in repair 125mm size brass chromium plated shower rose with or without swivel joints including fixing to steel pipe or union fixed complete all as specified and directed.
S & F in repair tubular towel rail 20 mm dia ‘D’ type 60 cm long between flanges of brass chromium plated.
Demolition of brick work or stone masonry, built in cement mortar complete all as specified and directed
M&L brick work with sub class 'B' bricks old size straight or curved on plan exc 6 mtr mean radius built in CM 1:6 complete all as specified and directed
M&L for Brick work with sub class old half brick size straight or curved on plan exc 6 m mean radius in cement mortar 1:4 complete all as specified and directed
Taking down cement plaster on brick wall/stone wall, ceiling etc, raking out joints, hacking for key & scrubbing with water complete all as specified and directed
M&L Rendering 10mm thick in CM 1:6 on fair faces of brick surfaces of walls finished the surface even & smooth without using extra cement complete all as specified and directed
M&L Rendering 15mm thick in CM 1:4 on fair faces of brick surfaces of walls and finished fair and even without using extra cement complete all as specified and directed
M & L for rendering 15mm thick in cement mortor 1:4 (5 mm thick with IWPC over a coat of 10 mm thick ) on Brick wall surfaces, finished even and smooth without using extra cement including preparation of new plastered surfaces and applying two coats of cement based paint over a Coat alkali resistant primer paint cement complete all as specified and directed. (Note: IWPC measured separately )
M&L Rendering 5 mm thick in CM 1:3 on fair faces of brick surfaces of ceiling finished the surface fair and even including praparation of newly plastered surfaces and applying Three coats of White wash on ceiling complete all as specified and directed
M&L for preperation newly plastered surfaces and applying two coats of oil bound distemper over a coat of chalk whiting primer including 3mm thick wall care putty on wall complete all as specified and directed
M&L for Preparing of Newly plastered surfaces and applying three coats of white wash on walls complete and all as specified and directed
M&L for Preparing of Old plastered wall surfaces and applying One coat of white wash on walls complete and all as specified and directed
M&L for praparation of old plastered surfaces and applying One coat of White wash on Ceiling complete all as specified and directed
M & L for preparation of old painted steel surfaces of any description, over 10 cm width or girth, not otherwise described and applying one coat of synthetic enamel paint complete all as specified and directed
S&F 4 mm thick Figured glass, pin head type and glazing with oil putty in squares n exc 0.5 sq. m in each pane complete and including Hacking out old broken glass (any thickness, size quality or description) from wooden frame or stone concrete or bricks sorrounds grazed with putty or fixed with beads complete all as specified and directed.
S & F stainless steel wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.4 mm and fixed with wooden beeds complete all as specified and directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for.
M & L for steel window with side hung shutters including projecting type hinges with steel handle and peg stay complete with glazing bars dovtailed or welded complete all as specified and directed.
M & L for steel window with side hung shutters including projecting type hinges with steel handle and peg stay complete without glazing bars dovtailed or welded complete all as specified and directed.
S&F of steel ventilators with top/side hung shutter including hings, steel peg stay complete all as specified and directed.
M & L for preparation of new or previously untreated steel surfaces of any description, over 10 cm width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and directed.
Demolition of cement concrete (unreinforced) of any description of any position not otherwise specfically provided for as in sunken floors & floor etc complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) and rubbish off the premises and M&L for non skid coloured ceramic tiles 7 to 8mm thick (square or rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc, and cement screed in CM 1:6, 15mm thick and jointed in neat cement slurry and pointed in white or coloured cement to match all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) and rubbish off the premises and M&L glazed ceramic coloured tiles 300X200X7mm thick in vertical surface fixed over and including 10mm thick back coat in CM 1:4, set and and jointed in cement slurry and pointed with white or coloured cement to match complete all as specified and directed.
M&L 25 mm thick PCC 1:2:4 Type B1 (usng 20mm graded stone aggregate) below files for levelling of exixting surface complete all as specified and directed.
M & L 75 mm thick PCC 1:4:8 Type D2 (using 40 mm graded stone aggregate) in sub base of floor complete all as specified and directed
M&L for 40 mm thick cement concrete type B-1, 1:2:4 (20mm graded aggregate) and surface even and smooth without using extra cement complete all as specified and directed
Demolition of cement concrete (reinforced) of any description and in any position not otherwise specifically provided for complete all as specified and directed
M&L for MS TMT bars, 10mm dia & over , cut ot length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with wire complete all as specified and directed
M&L for MS TMT bars,5 mm dia and over upto and including 10 mm dia in stirrups, spacers, binders cut ot length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with wire complete all as specified and directed
M&L for Pre Cast Cement Concrete 1:2:4 type B1 (using 20 mm graded aggregate) as in Cover slab for manholes etc set in cement mortor 1:4 including use and waste necessary form work (Note: Reinforcement shall be measured and paid seprately) complete all as specified and directed
M&L for Cement concrete (1:3:6) type C2 (using 40mm aggregate) in foundations,filling and mass concrete, coping, benching etc complete all as specified and directed
Surface excavation n.exc 30cm deep and averaging 15cm deep and getting out in hard/dense soil complete all as specified and directed
Excavation in trenches n.exc 1.5m wide & n.exc 1.5m depth for foundation etc or for shafts, wells, cesspits, manholes, pier holes etc n.exc 10 sqm on plan and n.exc 1.5 m in depth and getting out in hard and dense soil complete all as specified and directed
Excavation in trenches n.exc 1.5m wide & exc 1.5m but not exc 3.0m in depth for foundation etc or for shafts, wells, cesspits, manholes, pier holes etc n.exc 10 sqm on plan and n.exc 1.5 m in depth and getting out in hard and dense soil complete all as specified and directed
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick in any type of soil complete all as specified and directed
M&L for removing excavated surplus soil n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point complete all as specified and directed
Demolition and breaking up drain pipes, 150mm internal dia, (Salt glazed ware, AC or Reinforced concrete) set in cement mortar and haunching complete all as specified and directed
M&L for salt glazed stoneware drain pipes 150mm dia bore (Grade 'A' pipe) laid in trenches and jointed complete all as specified and directed
M&L for concrete bed to drain pipes 150mm dia using cement concrete 1:3:6 type C2 including packing under and haunching against the sides of pipes after they are laid and tested complete all as specified and directed
Taking down completely existing treatment along with plaster as in sunken slabs vertical faces.
M&L 40mm thick cement concrete type B-1, 1:2:4 (20mm graded aggregate) & surface even & smooth using extra cement with IWPC (IWPC measured and paid seperately) as in sunken slabs
M&L for applying evenly a coat of industrial bitumen 85/25 at the rate of 1.2kg/Sqm including cleaning surface complete all as specified.
M&L for 15mm thick in CM 1:3 rendering on brick or concrete/stone surfaces finished even and smooth without using extra cement with IWPC (IWPC measured and paid separately) as in sunken slab.
S&F of low density polyethylene pipes (LDPE) of pressure rating 6 Kgf/sqcm fixed to walls, floors etc of 32mm bore as in spouts for sunken slabs
M&L cement concrete type E-2, 1:5:10 (40mm graded stone aggregate) as in mass fillings.
Supply only integral water proofing compound.
S & F for Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc. complete, drilled for fixing of steel sheeting or other covering doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (Inclusing of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing, Fe 410-W (Gde-E-250) quality-A, etc complete all as specified and directed.
S & F Mild steel, plain, black sheet in wall cladding, steel gates and similar work, cut to size, holes punched; including round headed screws,clout nails or rivets and fixed to wood or steel framing with plain 40 mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, etc. as required, Thickness of sheet 1.60 mm, etc complete all as specified and directed.
M&L for walling of random rubble, uncoursed, well bonded, bedded and solidly hearted, built in cement mortar 1:6 complete all as specified and directed.
Damp proof course in cement concerte 1:2:4,type B0 and 25 mm thick to horizontal or vertical surfaces including necessary formwork etc complete all as specified and directed.
Use & waste of rough finished Square, rectangular or polygonal Form work to sides of pillars, posts, struts, columns and stanchions complete all as specified and directed.
M & L for reinforced Cement Concrete (Nominal mix) type B1 1:2:4 (using 20 mm graded granite stone aggregate) in Columns, piers, posts and struts complete all as specified and directed.
M&L for reinforced cement concrete (Nominal mix) type B1 1:2:4 (20 mm graded aggregate) in lintel bands, roof beams and cantilevers etc. complete all as specified and directed.
M & L for Form work to sides and soffits of floor or roof beams, lintels, shelves including supports, overhungs etc. for flat rough finished surfaces complete all as specified and directed.
Excavation over areas & depth not exceeding 1.5 M deep and getting out in hard/dense Soil complete all as specified and directed
Excavation over areas & depth exceeding 1.5 M and not exceeding 3 M deep and getting out in hard/dense Soil complete all as specified and directed
M & L for Sand filling under floors or in foundations including watering and consolidation complete all as specified and directed
M & L for Plain Cement Concrete Type D2 1:4:8 (using 40 mm graded granite stone aggregate) in foundations, filling and mass concrete complete all as specified and directed
Removing Excavated soils exceeding 500 M but not exceeding 1.5 KM and depositing where directed.
M&L for rendering 15 mm thick on stone masonry surfaces in cement mortar 1:3 and finished even and smooth without using extra cement.with water proffing compound complete all as specified and directed ( Note: WPC measured separately)
M&L for rendering 15 mm thick on fair faces of Stone surfaces or concrete surfaces in cement mortar 1:4 and finished fair and even without using extra cement complete all as specified and directed
M & L for preparing newly plastered surfaces & applying two coats of cement base paint over a coat of primer of surface of walls complete all as specified and directed
M & L for hardcore of gauge not exceeding 63 mm of broken granite stone, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to a true surface complete all as specified and directed
M&L 75 mm thick cement concrete type C-2, 1:3:6 (40 mm graded aggregate) finishing cement concrete surface even and smooth without using extra cement as in plinth protection complete all as specified and directed.
S & F Mild steel Angles, bars, flats etc., as in supports for stiffening of fencing, wall ties, hold fasts, clamps and similar small articles confirming to Fe 290.Gde-E-165 complete all as specified and directed.
S & F Mild steel work in framed work such as grills, gratings,framed guard bars, ladders etc., with ends of bars shouldered and/ or riveted, or forged into spikes, and similar work confirming to Fe 290.Gde-E-165 complete all as specified and directed.
Flush pointing to random rubble masonry, uncoursed or brought upto courses in Cement mortar 1:3 complete all as specified and directed.
M&L Moorum / red bajri filling in floors or pavings, laid in layers n exc. 15 cm thick, spread, levelled and rammed including watering complete all as specified and directed.
Formwork to edges of concrete flats, breaks in floors, opeinings in concrete walls, floors and roofs complete all as specified and directed.
RCC ( Nominal mix) Type B1 1:2:4 using 20 mm graded aggregate as in Slabs supported on walls, beams and columns in floors, roofs, landingsl, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed.
S&F for rotational moulded polyethylene (Triple Layer) water storage tank of capacity 10,000 LITRES (cylinderical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I complete all as specified and directed.
Excavation in trenches n.exc 1.5m wide & n.exc 1.5m depth for fdn etc or for shafts, wells, cesspits, manholes, pier holes etc n.exc 10 sqm on plan and n.exc 1.5 m in depth and getting out in Soft/Loose soil complete all as specified and directed
Excavating post holes or similar holes, each not exceeding 0.5 Cum, getting out in Soft/ Loose soil, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, watering, and removing surplus soil complete all as specified and directed
Spreading & Levelling and well ramming including watering as required in layers n.exc 25 cm thick complete all as specified and directed
M&L brick work with fly ash bricks built in CM 1:4 straight or curved on plan exc 6 mtr mean radius complete all as specified and directed
M & L for half brick wall with fly ash bricks straight or curved on plan to any radius built in cement mortar 1:4 complete all as specified and directed
M&L for providing, cement concrete 1:3:6 Type C1 using 20 mm graded aggregate in, coping complete all as specified and directed
M&L for plain Cement Concrete Type B1 1:2:4 (using 20 mm graded stone aggregate) in foundation filling, mass concrete and similar works and for MS Pipe fixing complete all as specified and directed
S & F for Steel work in tubular trusses & vertical post including special shaped washer etc complete using ERW or induction butt welded tubes conforming to I.S. 1161-1979 grade st-240 complete all as specified and directed
S&F MS Plain plates, square cut, with riveted, bolted or welded attachment Fe-410-W (Gde-E-250) quality A complete all as specified and directed
M & L pre-painted galvalume aluminium zinc coating GI based corrugated sheet 0.50 mm thick of any colour having tensile strength 550 mpa as in roof covering/ cladding to wall, fixed with self tapping screws complete all as specified and directed
M&L for use & waste of rough finished flat Form work to sides of concrete foundations rafts, footing, base of columns, raft and raft beams, sides & soffits of foundation (if any) of foundation and plinth beams and similar work complete all as specified and directed
M & L for reinforced Cement Concrete (Nominal mix) type B1 1:2:4 (using 20 mm graded granite stone aggregate) in foundations including rafts, footings and mass concrete, foundation beams, plinth beams, bases for columns, basement slabs etc. complete all as specified and directed
M&L for formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) rough finished surface complete all as specified and directed
M&L for formwork to edges of concrete flats, treads, breaks in floors,window cills, concrete railings,openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide rough finished surfaces complete all as specified and directed
S&F for non skid coloured ceramic tiles 7 to 8mm thick (square or rectangular) area of each tile exceeding 0.06sqm but not exceeding 0.11 sqm, in floors etc, and including 15mm thick screed bed in CM 1:6 and jointed in neat cement slurry and pointed complete all as specified and directed
S&F for glazed ceramic coloured tiles of size 300x200x7mm thick for vertical surfaces as in dado/skirtings set and jointed in neat cement slurry and pointed in white or coloured cement to match and over including 10mm thick rendering in CM 1:4, complete all as specified and directed.
Supplying and laying, connecting and testing steel water tubing of dia 15mm bore pipe medium grade ISI Marked and confirming to IS 1239 galvanised iron water tube with all fittings laid in trenches, fixed to wall or ceiling etc complete all as specified and as directed.
All as per Item No. 126 But 20mm bore pipe
All as per Item No. 126 But 25mm bore pipe
All as per Item No. 126 But 40mm bore pipe
All as per Item No. 126 But 50mm bore pipe
All as per Item No. 126 But 80mm bore pipe
Supply and fix CI sluice valves PN 1.6 of size 80mm dia confirming to ISI with flanged ends, both end drilling with SS spindle, round wheel including jointing materials, nuts, bolts and gasket complete all as specified and directed.
S&F Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed 50 mm bore complete all as specified and directed
S&F Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed 40 mm bore complete all as specified and directed
S&F Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed 25 mm bore complete all as specified and directed
S&F Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed 20 mm bore complete all as specified and directed
S & F Rotational moulded polyethylene water storage tanks double layer (cylindrical vertical with closed top ) of 1000 ltr capacity hoisted and fixed in position complete all as specified and directed.
S&F for PVC ball valve 25 mm dia high pressure of PTMT with epoxy coated aluminium rod and high density plasic ball screwed for iron pipe and fixed . (minimum weight 25 mm- 455 gms )
S&F PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors 110 mm bore complete all as specified and directed
S&F PVC (SWR) bends any radius 110mm bore complete all as specified and directed
S&F PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors 75mm bore complete all as specified and directed
S&F PVC (SWR) bends any radius 75mm bore ccomplete all as specified and directed
S&F PVC (SWR) floor trap 75mm dia outlet, plain with grating including jointing with solvent cement complete all as specified and directed
S&F concealed stop cock, fancy type 15mm dia, chromium plated with long shank and cup (concealed type) complete all as specified and directed
S&F for 15 mm dia fancy type bib taps cast copper alloy chromium plated type screwed down, screwed for iron pipe or for brass ferrule complete all as specifie and diredted.
S&F for 150 mm long alluminium alloy anodized handles fabricated type
S&F Vitreous China squatting pan , "Orissa" pattern size 580 X 440 mm white with intgrel footrest (excluding flushing cistern & flush pipe) including 110 dia PVC SWR 'P' or 'S' trap complete including provision of cement concrete all as specified and directed.
S&F for PVC valveless syphonic action type flushing cistern 10 lit capacity low level white with inlet, ball valve, float and handle including brackets and 32mm PVC flush pipe flush pipe complete all as specified and directed
S & F vitreous china bowl urinal flat back size of 465 x 355 x 265mm white (minimum) with grating and union for discharge pipe (excluding flushing cistern & flush pipe) but exncluding waste pipe, complete including providing & fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with screws, pointing around urinal back in cement complete all as specified and directed.
S&F urnial spreader of PTMT any colour for fixing with 15 mm dia pipe (minimum weight 60 gms) complete all as specified and directed.
Supply, install and commissioning Centrifugal Monoblock pump set suitable for 415 V, 3 phase system having capacity 5 HP alongwith connecting fitting/fixtures including necessary PCC foundation, concrete bed and base frame and connections complete all as specified and directed
M & L for construction of new valve chamber 900x900x900 mm inner dimensions, brick masonary in cm 1:4 PCC base in 1:3:6 of 7.5 cm thick & plastering 15 cm thick in CM 1:4 in inner side/ coping of all chamber fabrication of Iron frame 40x40x6 mm size angle iron MS cover 3 mm thick with hinges and locking arrangements duly painted excavation,earth work complete all as specified and directed
Taking down carefully unserviceable copper/aluminium point wiring (light, fan, socket or power) including unserviceable fittings such as switches, ceiling roses, pendents, regulators, socket, light fittings etc complete and making good disturbed surfaces of walls, floors etc.complete all as specified and as directed
M&L Point wiring for one light point/fan point/bell point controlled by one switch with 1.5 sqmm multistrand copper conductor cable PVC (FRLS) insulated unsheathed copper conductor single core multi stand flexible cable and 1.50 sqmm PVC (FRLS) insulated unsheathed copper conductor single core cable ( green colour) as earth lead in and including non metalic rigid PVC conduit medium grade with appropriate size with all fittings (ISI Marked) suitable for concealed wiring on stone/brick,masonary walls,roof etc including in sunk box of required size & 2 mm thick plastic laminated sheet for housing switches sockets, regulators etc, including making good the disturbed surfaces to match with the existing specification ,complete all as specified and directed at site .
All as per item No.154 but for One 5 pin 15 / 16 Amps switch socket outlet point on independent board with 2.5 sqmm PVC (FRLS) insulated unsheathed copper conductor single core multi stand flexible cable and 2.5 sqmm PVC (FRLS) insulated unsheathed copper conductor single core cable (green colour) as earth lead complete all as specified and directed by the Engr-in-charge.
Supply and fix switch piano flush type single pole one way 5 Amps complete all as specified and directed.
Supply and fix Ceiling rose surface bakelite three 65x50 mm, terminals 240 volts complete all as specified and directed.
M&L Switch socket combination 2 in 1 flush type universal 3 pin 6 & 16 Amps complete all as specified and directed
Supply and fix lamp holder insulated body with back plate suitable for battern fittings complete all as specified and directed.
Supply and fix 9/10 watt LED Bulb, base B-22 complete all as specified and directed.
S&F Wall mounted indoor decorative 20W LED 6000K (4 ft.), extruded aluminium batten in anodised finish with opal diffuser, IP20 heat sink provided for efficient heat dissipation and integrated electronic driver, lamp color white complete set including necessary connection with twin twisted unsheathed PVC copper cable of suitable size complete all as specified and directed.
Supply and fixing LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics with IP 65/66 protection complete all as specified and directed.
Supply and fix exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 300m complete all as specified and directed.
Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.
S&F Sheet metal enclosure MCB DB including 200 Amps bus-bar single pole and neutral 240V, 4 Ways, double door sheet metal enclosure complete all as specified and directed.
Supply and fix Sheet metal enclosure IP-43 double door for DBs(where MCBs are reqd) SPN 240 V, for 08 ways, complete all as specified and directed.
Supply and fixing 240V, 10 KA 'C' curve miniature circuit breaker (MCB) of SPN and current carrying capacity 6-32 Amp in the MCB DB with connection testing and commissioning complete all as specified and directed.
Supply and fixing 240V, 10 KA 'C' curve miniature circuit breaker (MCB) of SP and current carrying capacity 6- 32 Amp, in the MCB DB with connection testing and commissioning complete all as specified and directed.
M&L sub main wiring with two single core PVC-FRLS insulated unsheathed multi stranded Submain wiring with two single core PVC (FRLS) insulated flexible copper conductor cable of size 2.5 Sqmm and one single core PVC (FRLS) insulated unsheathed flexible copper conductor cable green colour of size 2.5 Sqmm as earth lead in and including PVC conduit medium grade with all fittings laying on surface conduit and making good the disturbed wall surfaces to match with existing specification all as required complete all as specified and directed. Note : (i) Two single core cable and one run of earth copper cable will be measured and paid as one unit length
Supplying and fixing 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable flat or circular of size 6 Sqmm complete all as specified and directed.
Supply, laying and testing XLPE cable Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 sq mm 4 core complete all as specified and directed.
Supply, laying and testing XLPE cable Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sq mm 4 core complete all as specified and directed.
Supply and spread sand in trenches as sand cushioning to under ground cable for protection using fine river sand and provide required cover after punning down complete all as specified and directed. (Note:Punned thickness shall be measured and paid)
M&L brick protection with common burnt bricks sub class ‘B’ of size 230 x 115 x 75mm for cable protection complete all as specified and directed.
M&L Earthing complete with galvanized steel with plate electrode 60 cm x 60 cm x 6.3mm thick buried directly in ground (earth kit not less than 2.25 mtr below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level connected to galvanized steel strip 32mm x 6mm dia by means of bolts, nuts and washers of galvanized iron or steel all as shown in electrical plate No 3 of SSR part-I connected to earth test point incl necessary earth work and excavation PCC 1:3:6 type C1 using 20mm graded stone aggregate for earth chamber with SSR Part-II RCC cover 50mm thick 1:2:4 mix type B1, using 8mm dia TMT bars reinforcement @ 140mm c/c both ways, watering funnel with water pipe GI pipe 15mm dia medium grade and protection pipe GI 40 mm dia, light grade all as specified and directed in SSR Part II complete all as specified and directed.
M&L, in repair, earthing complete with galvanized steel earth plate electrode of 60 cm x 60 cm x 6mm thick buried directly in ground [earth pit not less than 2.25 metre deep below normal ground level] with top edge of the plate not less than 1.5 m below normal ground level, connected to galvanized earth wire of 4mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical plate No. 3 of MES SSR Part I all as specified and testing on completion including provision of earth lead protected by 15 mm dia light grade GI pipe & watering pipe shall be 20 mm bore medium grade GI pipe including all excavation and earth work, PCC pit with RCC cover, char coal, salt, funnel etc complete. Note:- Rate quoted by tenderers shall be deemed to include for following provisions-[i]. Excavation & earth work in any type of soil including removing of surplus material upto 50 m. [ii].PCC 1:3:6 type C1 using 20mm graded stone aggregate in pit & 40mm thick precast RCC 1:2:4 type B1 cover 50x50 cm with 8mm TMT bars @ 10 cm C/C both ways with handles.[iii]. Main earthing lead from earth electrode to test point upto 7.5 mtr.[iv]. Funnel with watering pipe [GI pipe] 20mm bore medium grade & copper lugs, charcoal & salt as reqd.[v]. GI protection pipe of size 15 mm bore light grade 7.5m.
Sri Lakshmi Enterprises
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .