| 1 | 1₹19.1 LAccepted-AOC A 4 TARINI APARTMENT PHASE I KILBURN COLONY HINOO DISTT RANCHI JHARKHAND 834002 | RANCHI | RANCHI | JHARKHAND | 834002 | 1 | Accepted-AOC Lowest | |
| 2 | 2₹21.2 L+₹1.3 L (6.55%)Rejected-Finance | 2 | Rejected-Finance Higher | |
| 3 | 3₹21.5 L+₹1.6 L (8.28%)Rejected-Finance | 3 | Rejected-Finance Higher | |
| 4 | 4₹22.9 L+₹3.0 L (15.2%)Rejected-Finance | 4 | Rejected-Finance Higher | |
| 5 | 5₹23.6 L+₹3.7 L (18.8%)Rejected-Finance | 5 | Rejected-Finance Higher |
Tender Value
₹26 L
EMD Value
₹52,000
Closing Date
24 Nov 2021, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Amritsar
GE Amritsar PIN-143001
SPL REPAIR TO SEWAGE LINE OTM ACCN AND 04 BATHROOM IN UNIT LINES AT OLD AMRITSAR CANTT
2021_MES_484782_1
GE/ASR-33/2021-22
Open Tender
Civil Works
Item Rate
243 days
GE Amritsar
Class D, category ai
8 documents required · 8 mandatory
₹500
GE Amritsar
₹52,000
Yes
22 Jan 2022
28 Oct 2021
25 Nov 2021
28 Oct 2021
24 Nov 2021
11 Nov 2021
60 days
Amount
B/R Portion:- Taking down cement plaster on brick or stone or concrete surfaces of wall etc ,icluding raking out joints , hacking for key, scrubbing down with water etc.
M& L for rendering 15mm thick on fair face of brick works or concrete surfaces of walls with CM (1:6) finished the surface for even and smooth without using extra cement all as per specified and directed.
M& L for rendering 15mm thick on other than fair face of brick works or concrete surfaces of walls with CM (1:4) finished the surface for even and smooth mixed with WPC @100 ml per 50 kg of cement or all as per manufacturing instruction. (180+400) Note:- WPC shall be measured & paid separately.
M&L for Rendering 5mm thick in CM 1:3 to fair face of brick works or concrete surfaces of ceiling finished the surface for even and smooth without using extra cement all as per specified and directed.
M&L for preparation of new plastering surfaces of walls and applying two coat of cement base paint over a coat of cement primer etc. complete all as specified and as directed
M&L for two coat of oil bound distemper over a coat of primer on newly plastered surface of wall incl preparation of surface complete all as specified and as directed
M&L for Three coats of white washing on new plastered surfaces of ceiling , chajjas after preparation of surfaces all as specified and as directed.
M&L for one coat of white wash including preparation of old decorated surface of ceiling all as per specified and directed.
Demolition of Brickwork or stone/boulder masonry, built in CM or cement lime mortar including all quions, arches, pillars etc, but excluding ashlar facings, dressed stonework & precast concrete articles (3+72)
M&L brickwork with subclass `B' bricks, straight or curved on plan exc 6m mean radius, built in CM (1:6) as in boundary wall, drain etc complete all as specified and directed.
All as per Srl Item No 10.00 here-in-before, but except bricks. Note:- Serviceable bricks obtained from dismantling of brick work shall be reused.
M&L brickwork with sub-class `B' brick straight or curved on plan to any radius in half brick thick walls built in CM (1:4) as in boundary wall, manhole etc complete all as specified and directed. (15+10)
Demolition of Reinfoced cement concrete for roofs, floors,(other than ground floors) beams , stair cases, landing,chajjaa and similar suspended work.
M&L for RCC with type B0 (1:2:4) (using 12.50mm graded aggregate ) in Slabs supported on walls , beams and columns in floors , roofs ., landings, balconies , canopies, deck slabs and cover slab in shelves and the like all as per specified and directed.
Use & waste of formwork to the soffits of suspended slabs such as roof slabs , floor slabs , landings and similar work ; not exceeding 200 mm thick ( Horizontal or sloping ) and making flat rough finished surfaces of concrete .
M&L for TMT bars 6 to 8 mm mm dia and over , cut to length , bent to shape required , including cranking , bending spirally for hooping ends and binding with and including mild steel wire ( annealed ) not less than 0.9 mm dia or securing with clips all as specified and directed.
S&F for 15 mm Bib taps, cast copper alloy fancy type chromium plated with capstan head screwed down screwed for iron pipe of 15mm bore and fixed in repair, including extra CP nipple wherever required all as per specified and directed.
S&F in repair for 15mm dia Stop valves, , high pressure, with crutch or butterfly handle, chromium plated, fancy type, screwed both ends for iron pipe or for unions,including extra CP nipple wherever required. complete as all as specified and directed.
S&F in repairs 15mm bore stop valve fancy type chromium plated with long shank and cup (Concealed type) cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions including extra CP nipple wherever required. all as specified and directed.
S&F in repair 20 mm gun metal globe or gate valve with iron wheel head, screwed both end for iron pipe
S&F in repair Brass chromium plated Tubular towel rail 20mm dia, D type, 60cm long between flanges
S&F in repair glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with plated bracket guard and railing 60cm long.
S&F in repair for Vitreous China wash basin, white, flat back, size 500 X 400mm, excluding taps, waste, chain and plug and porcelain stopper but including brackets including cutting for and pinning in ends of brackets or erecting stand complete as in repair all as specified and directed.
Supply and fixing in replacement pillar tap 15mm dia cast copper alloy long nose with capstan head chromium plated fancy type, screwed down high pressure, with or without letters ‘Hot’ or ‘Cold’ with long screwed shanks and fly-nuts, screwed for iron pipe,complete all as specified.and directed .
S&F grating doom 125 mm dia PTMT ( minimum weight 40 gms )
S&F in repairs for brass chromium plated shower rose 125 mm size with swivel joint including fixing to 15mm dia steel pipe or union including extra CP nipple wherever required..
S&F in repair for 10 Ltrs capacity, PVC valveless, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets complete with all internal accessories and fixed to wall and jam nuts on both sides, PVC flush pipe 32mm dia 90cm long fixed properly to inlet of WC and making good to disturbed surfaces of wall or floor complete as in repair all as specified and directed.
S&F for vitreous china squatting pan 'Orissa' pattern, size 580x440mm white, with integral foot rests (excluding flushing cistern and flush pipe)including connection to trap, and to flushing pipe, anti-syphonage pipe etccomplete including making good to floors with PCC bedding (1:5:10) type E2 using 40mm nominal brick ballast and connection to trap with pre solution all as specified, and making good to floor including demilition of PCC / Lime concrete bedding existing pan complete as in repairs all as specified.
S&F for Vitreous China wash down water closet pan (pedestal pattern), white (excluding fixing bolts, flushing cistern and flush pipe) front or back inlet including connection to drain (or outgoing pipe) and to flushing pipe, anti-syphonage pipe, etc and making good to floor complete as in repair all as specified and directed.
S&F in repair plastic water closet seat, white , closed patern withflat bottom and cover and mild steel chromium plated or aluminium hinging device
S&F Vitreous China Urinal, Half stall type, white (excluding flushing cistern, flush pipe and wasteVitreous China urinals, bowl type (back or corner wall type),complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets, flush pipe, grating and Union for discharge pipe. (Exclusive of fixing supply pipe to flushing cistern, trap and waste pipe)
S&Fin repair PVC waste pipe 32/38/40 mm bore 600 to 750 mm long comlete all as specified and directed.
S&F in repair PVC connections 15mm size with PTMT nuts of length 450 mm.
S&F for 40mm waste fittings, brass, chromium plated for glazed ware sinks, basins etc with long screwed shanks and fly nuts, flange end bedded in red lead cement and other end fixed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing unserviceable rubbish off the premises all as directed.
M&L for Non-skid Ceramic colour tiles 7 to 8mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over & including 15 mm thick screed bed or bedding layer in cm (1:6) all as specified and directed.
M&L for Glazed ceramic colour tiles in vertical surface 450x300x7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match over & including 10mm cement plaster in cm (1:4) all as specified and directed.
M&L 20mm thick Granite (of any tpe) work (table rubbed and polished) in steps, jambs, pillars, window cills,cooking platforms and like in CM(1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite over & including 15 mm thick Screed in CM (1:6)
Taking up or down steel tubing and connections for 15mm bore of pipe all as directed.
Re-fixing for 15 mm bore old steel tubing and connections in new or old position (Walls, ceiling, floors etc) including cleaning, re-running the old screw threads etc complete all as specified and directed.
S&F for 15mm bore Tubes, 'medium grade' galvanised, with all fittings and fixed complete to walls and ceilings or laid in floors , wall etc ( surface or concealed type) all as specified and directed.
Taking up or down steel tubing and connections for 20mm bore of pipe all as directed.
S&F for 20 mm bore Tubes, 'medium grade' galvanised, with all fittings and fixed complete to walls and ceilings or laid in floors , wall etc ( surface or concealed type) all as specified and directed.
Re-fixing for 20mm bore old steel tubing and connections in new or old position (Walls, ceiling, floors etc) including cleaning, re-running the old screw threads etc complete all as specified and directed.
S&F for 500 Ltr capacity Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position with manhole cover of tank with its locking arrangement, making hole for inlet, outlet and overflow connection including dismantling / taking down old PVC water tank, ball valve etc complete all as specified in SSR Part-I all as specified and directed.
S&F in repair 20 mm Ball valves high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe and fixed. (Minimum weight 2 0mm-210gms)
Taking down chowkats with shutters (without taking down of shutter from the frames) exc 1.50 Sqm and n.exc 4.00 Sqm each.
Supply and fixing factory made PVC Internal door frame of size 100 mm x 45 mm with a wall thickness of 5 mm (+0.25) , made out of extruded 5 mm (+0.25) thick PVC sheet manufactured by asn ISO - 9001-2008 certified company, and by joining 3 Nos heat bent PVC sheet sections. The inside section of size 90 x 30mm shall be made from plain colour PVC sheet of 5 mm (+0.25) thickness. The inside section will be covered by sticking two sections of size 30 x 35 mm and 70 x 45 mm made from 5 mm (+0.25) thick plain PVC sheet. The frame shall be mitre cut at two corners and oined with 4 Nos of 150 mm long brackets of 15 mm x 15 mm square tube . The two vertical door frames are to be reinforced with 40mm x 20mm MS tube of 19 guage through out the frame . The door frame shall be fixed to the wall using 8/100 mm long MS Screws through thee frame by using anchor fasteners. A minimum of 4 Nos of screws to be provided for each vertical member & minimum 2 Nos for horizontal member etc as per manufacturer's specification, complete all as specified and directed.
Material and Labour for Providing 30mm thick FACTORY MADE MOULDED DOOR SHUTTER - WOOD FREE consisting of frame made out of M.S. tubes of 19 gauge thickness and size of 20mm x 40mm for stiles as well as top, bottom & lock rail. M.S frame shall have a coat of metal primer of approved make & manufacturer. The inside panel shall consist of 20mm thick multichamber hollow PVC section of 1 mm wall thickness, bonded using solvent cement / eynoacrylate adhesive with 5mm (+0.25) thick moulded PVC sheet of Density 600 Kg/Cbm Manufactured by an ISO-9001-2015 certified company with 2, 4, 6 raised panel design in plain/prelam colours after routing the moulded design on one side of the inside panel, 5mm (+0.25) plain/prelam PVC sheet to be pasted using solvent cement / cynoacrylate adensive on other side of the Hollow PVC section. All the four edge of the panel to be sealed with lipping of 10mm thick & 20mm wide PVC sheet baton (Made by sticking 02 Nos. foam PVC sheets of 5mm (+0.25) thickness using PVC solvent cement adhesive. Door edge lipping to be painted with PVC ink of matching colour of plain / prelam mouded PVC sheet of door. 20mm thick (5mm x 4 Nos) thick PVC sheet to be given for lock provision at lock height. Door to be fixed with frame with 3 nos. stainless steel but hinges of size 100mm x 25mm x 2mm and 50mm longsteel screws drilled suitable to pass through both the walls of M.S tube. other hardwares should be fixed with 25mm x 8mm size steel screws etc, complete as per direction of Engineer-in-Charge, manufacturer's specification and drawing.
M&L mild steel framed works, as in door frame, manhole cover frame,gates of angle or other section with gusset plates, rails, braces etc, drilled for fixing of steel sheeting including drilling or fixing welding be prepared for hanging or sliding with and either hooks and hinges fixing, similar work conforming to Fe 410-0 or Fe 310-0 complete all as specified. (170-300)
S&F 30 mm thick flush shutter, soild core construction, with block board core and plywood face panel commercial type on both sides complete all as specified.
Taking down steel window / ventilator of any description & size n exc 1.50 sqm area all as specified and as directed. all as directed.
S&F in repair box type steel ventilator made of ERW tube P-section of size 60mmx25mm outer frame ( single rebated), comprises glazed shutter, frame of ERW tube and FI 2mm thick welded/screwed to frame for fixing of sheet glass including fixture and fittings like as stopper, cleat, pintal hinges, hold fast etc all as shown on drg No CEJZ/TD-06/07 dt 07.06.07 incuding cutting holes complete all as specified. Note: Sheet glass and painting shall be measured and paid Separately.
S&F framed work such as grill, framed guard bar and similer work conforming to FE 290, GDE E- 165 all as specified and as directed.
S&F for stainless steel wire cloth 0.36mm nominal dia of wire and average width of aparture 1.40mm and fixed with stainless steel wire staples in window and door as in new door/window.
S&F 4.0mm thick Figured glass, pin headed type and glazing with oil putty in squares not exceeding 0.5 Sqm in each pane in any position all as specified and directed.
S&F butt hinges 100mm size medium weight cold rolled mild steel, fixed with screws or welded to steel frame complete all as specified and directed
S&F 150 mm aluminum , anodised, barrel tower bolts of extruded section .
S&F 150 mm aluminum Handle Cast type .
S&F 250mm aluminum alloy, anodised , sliding door bolt with hasp and staple ( bolt type ) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded section or cast aluminum alloy and fixed.
M&L for preparation of new steel surface and applying two coat of synthetic enamel paint over one coat of red oxide primer on new surface all as per specified and directed.
M&L for preparation of new wood surface over 10 cm girth or width and apply two coat synthetic enamel paint over a coat of pink primer all as per specified and directed.
Demolition of cement Concrete in sunken floors exc 15cm thick ( above ground level) and disposing the rubbish to a distance exceeding 50 Mtr but not exceeding 100 Mtr away to low lying areas complete all as specified and directed
M&L cement concrete (1:2:4) type B-0 using 12.5mm graded stone aggregate as in sides of sunken slab benching etc including necessary form work complete all as specified.
M&L rendering 15mm thick cement plaster as in sunken portion in cement mortar 1:3 using water proofing compound, finished fair and even without using extra cement complete all as specified. (WPC measured saperatly)
S&F 40mm bore steel water tubing grade galvanised inserted at the end of lateral slope projecting atleast 25cm beyond the outermost part of the building below the drain pipe up to two storey construction as spout for sunken, and all joints should be sealed properly by epoxy sealent complete all as specified.
M&L Water proofing treatment to sunken floor including wall comprising with the following course of treatment/ specification from bottom to top. (a) Applying bituminous primer @ 0.40 ltrs per sqm over plastered surface of floor for treating the sunken floor all as specified & as directed by Engr-in-Charge. (b) Apply a coat of hot bitumen 85/25 penetration grade bitumen @ 1.20 kgs/Sqm. (c) One layer of 3mm thick APP film based poly meric membrance minimum weighing 3Kg per Sqm reinforced with polyester non wove fabric (weight not less than 150 gms/sqm) land on primed surface by forced application over entire area, complete all as specified and directed. Note:-(i) After plastering testing tobe carried out by ponding (For 48 Hrs) and any leakage/Seepage observed shall be rectified before water proofing treatment. (ii) Laying of APP membrane shall be done as per manufracturers instructions . (iii) Joints tobe touched hot and Minimum width of overlaps not less than 150mm.
M&L Plain cement concrete (1:5:10) type E-2 using 40mm graded stone aggregate as in sunken filling as mass concrete or in sub base of floors complete all as specified.
Dismantling of 100/75 mm bore cast iron or reinforced concrete drain pipes, jointed in cement mortar and taking out of floor/trenches, if required all as directed.
S&F in repairs110 mm bore PVC (SWR ) pipes single socketed, in any lenth with rubber ring fixed to wall.
S&F PVC (SWR) bend 110 mm size
S&F 110 mm bore PVC (SWR) single Tee
M&L 75 mm PVC (SWR) floor trap, plain with grating including jointing with solvent cement
Dismantling brick tiles or terracing tile, single/double layer on roof including mud phuska any thickness and leepng plaster, seggregating, cleaning and stacking servicable tiles for reuse complete all as specified and directed.
Demoliton of mud in roof any thickness including mud plastering and removing to distance exc 250m but n exc 500m complete all as specified and directed.
M&L for 40mm thick brick tiles, laid on and including 15 mm thick cement mortar 1:6 and joints grouted and pointed flush in CM 1:3 mixed with 5% crude oil by weight of cement complete all as specified and directed.
All as per Srl Item No. 77.00 here-in-before but except brick tiles. Note:-Old serviceable tiles shall be reused.
M&L for PCC (1:3:6) type C-0 (using 12.5mm graded stone aggregate) averaging 50 mm thick as in roof padding mixed with & including WPC @ 100ml per 50 Kg cement finishing the surface even and smooth without using extra cement complete all as specified and directed .Note : WPC shall be measured and paid separately under relevant item of Sch 'A').
M & L for applying evenly a tack coat of industrial bitumen 85/25 grade @ 1.2 Kg/Sqm including cleaning surfaces etc complete all as specified
Material & Labour for APP based polymeric membrane minimum weighing 3Kg/Sqm and minimum 3mm thick reinforced with polyster non woven fabric ( Wt not less than 150 gms /sqm ) laid on bituminous surfaces complete all specified.
Supply only water proofing compound liquid type (ISI Marked) . (6+120)
Excavation in trenches not exceeding 1.5 metre wide and not exceeding 1.5 metre deep for foundation, manholes,sewage line etc exc 10 sqm on plan and getting out in soft/loose soil complete all as specified. (10+550)
Add to item No 83 above but depth exc 1.5m and not exc 3m all as specified and as directed.
Returning,filling in,spreading,levelling,watering and well ramming in layers not exc 25cm thick each complete all as specified and directed. (6+464)
Removing excavated material to a distance exc 250mtr but n.exc 500 mtr and depositing where directed at a level not exc 1.50 metre above the starting point complete all as specified. (4+116)
Demolition and breaking up existing unserviceable 150 mm bore SGSW pipe and haunching against the sides of pipe at any depth including removing rubbish to a distance exceeding 100m complete all as specified & directed. (40+750)
All as per item No 87 above but 200mm bore
Supplying,laying in trenches, jointing and testing 150 mm bore salt glazed stoneware pipe grade 'A' drain pipe ISI marked all as specified & directed.( Excavation and earthwork shall be measured and paid for separately under appropriate items of Sch. 'A'). (40+750)
All as per item No 89 above but 200 mm bore
Material and labour for PCC 1:4:8 type D-2(using 40mm graded crushed stone aggregates)for bed of sewage lines of 150 mm bore including packing under and haunching against the sides of pipe after they are laid and tested complete all as specified and directed. (40+725)
All as per item No 91 above but for 200mm bore
Material and labour for 15mm thick granite stone slab urinal partition fixed to wall and making good in cement mortar , complete all as specified and directed.
M & L cement concrete 1:3:6 type C-2 (using 40 mm graded crushed stone aggregate) in foundations, filling and mass concrete all as per specified and directed.
M & L providing cement concrete 1:2:4 type B-1 (using 20 mm graded crushed stone aggregate) as in surface of channel, drain, benching and PCC bend for top of manhole brick work etc with slightly chamfered or rounded angles including necessary form works, if any and finishing exposed surface even and smooth without using extra cement etc complete all as specified and as directed.
M&L for brick work with subclass 'B' bricks, straight or curved on plan exc 6 m mean radius, built in cement mortar 1:4 all as specified and directed.
All as per item No 96 above, but except bricks, Note : Serviceable brick obtained from Srl item No 9 shall be reused.
M&L providing precast cement concrete 1:2:4 type B-1 (using 20 mm graded crushed stone aggregate) in landings, cover slabs (for manholes etc) chullah hoods, chajjas, water troughs setting with cement mortar 1:4 and including form work complete all as specified and directed.
S&F mild steel TMT bars 10 mm dia and over, cut to length, bent to shape required, incl cranking, bending spirally for hooping for columns, hooking ends and binding with and incl mild steel wire (anealed) not less than 0.9 mm dia or securing with clips.
Cutting into existing man holes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement pipe concrete 1:2:4 type B-I smooth finished and reforming benching as required internal dia of pipe 150 mm.
All as per item No 100 above but for 200mm bore pipes
S&F 110 mm bore (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified & directed by Engr-in-Charge.
E/M Portion Taking down carefully the existing aluminium point wiring of any size and capacity and type by disconnecting from the either terminals complete including fittings and fixtures such as switches, sockets,ceiling rose, regulators and light fittings any type etc by unscrewing and taken away from site complete. Note :cost of unserviceable materials will be charged from the contractor against schedule of credit.
M & L Wiring complete with 1.5 sqmm single core PVC insulated unsheathed cable 1100 volts grade, multistranded with copper conductors conforming to IS specifications, drawn through and including conceled conduit concealed/ fixed on wall / ceiling with suitable clamps, screws, etc or concealed in wall including terminal boxes fabricated with 1.6 mm MS sheet concealed in walls covered with plastic laminated sheet top cover 3 mm thick fixed with cadmium plated iron screws for housing the switches, switch sockets outlets, fan regulators, etc, including provn of 1.5 sqmm PVC insulated unsheathed cable with multistranded copper conductor as earth continuity conductor and connecting to common earth dolly all as specified and as directed :- (a) One light point/Bell/Fan point controlled by one switch.
All as per item No 104 above but one 3 pin 5 amps switch socket on independent board.
All as per item No 104 above but one 3 pin 5 amps switch socket on same board.
All as per item No 104 herein before but with cable 2.5 sqmm (nominal area) multistranded copper wire unsheathed for one 3 pin socket outlet 15 amps on independent board including continous earth wirte PVC insulated 1.5 sqmm copper multistranded conductor connecting to common earth and earth dolly complete all as specified and directed Note for items Nos 2&3 :- (a) The wiring shall be done in proper colour coding using red,yellow and blue for phase,black for neutral and green for earth leads.
Supply and fix switch piano one way 5 A, SP, 230 Volts.
Supply and fix Socket outlet 2 in 1, 3 pin 5 Amps Flush type.
Supply and fix Switch outlet 2 in 1, 3 pin15 Amps Flush type.
Supply and fixing ceiling rose surface bakelite 3 terminals 65x32mm complete all as specified
S&F Lamp holder, PVC/Polycarbonate type with cord grip cap suitable for pendant/batten fittings complete all as specified and directed
Supply and fix wall/ceing mounting LED 18 Watt PC Diffuser tube light fitting complet with all aceesories 1x18W LED suitable for domestic application 240Volts 50HZ including one tube rode and internally pre-wired with 1.5 sqmm twin twisted flexible copper conductor and complete of.
M & L for sub main wiring with 1100 volt grade two single core PVC insulated and unsheathed cable with stranded copper conductor 4 sqmm drawn into and including electrical grade PVC conduit not less than 25 mm dia with IS 9537 (Part-III) 1983 mark, or relevant ISI mark with all accessories fixed concealed including chase cutting in brick/ stone masonry for fixing conduit and making good the disturb surfaces of wall as per existing including 2.5 sqmm multi - stranded copper conductor as earth wire in green colour complete all as specified and directed.
S&F Distribution Board double Door made out of CRCA mild steel sheet surface with insulated material like polyester or with epoxy powder coating and IP 43 & IK 09 protection surface mounting SPN 4 way, 240 volts with bus bar rating 200 Amps, dust and vermin proof suitable for incorporation of MCB’s and isolators etc complete all as specified. Make :Legrand Lexic / Hager /Schneider Elect . (Note : cost of removing old wooden box and making good of surface as original by brick work, plastering, whitewash/colour/distemper etc is included in quated rate)
S & F in repair MCB double pole, 240 volts, 16 Ampere, rupturing capacity 10 KA, ‘B’ curve type complete all as specified and directed.
S & F in repair MCB single pole, 240 volts, 6 to 32 Ampere, rupturing capacity 10 KA, ‘B’ curve type complete all as specified and directed.
Supply and fixing of socket outlet two-in-one, 3 pin each suitable for 5 and 15 Amperes flush type, 250 volts AC complete all as specified and directed.
S&F exhaust t fan 300 mm sweep metal body heavy duty including cutting of wall /window/lowers and fixing arrangement complete all as specified and directed.
G S ENTERPRISES
CHARAN SINGH CONTRACTOR
RAJ KAMAL BUILDERS
m/s. gopal krishan
Puri Engineers
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .