Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹36.9 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹37.2 L+₹27,215.20 (0.74%)Rejected-Finance | L2 | Rejected-Finance Being higher bidder | |
| 3 | L3₹40.1 L+₹3.3 L (8.82%)Rejected-Finance BHAVANI KRUPA GANDHI CHOWK PULGAON 442302 | WARDHA | MAHARASHTRA | 442302 | L3 | Rejected-Finance Being higher bidder | |
| 4 | L4₹40.6 L+₹3.7 L (10.0%)Rejected-Finance | L4 | Rejected-Finance Being higher bidder | |
| 5 | L5₹41.6 L+₹4.7 L (12.9%)Rejected-Finance | L5 | Rejected-Finance Being higher bidder |
Tender Value
₹43.4 L
EMD Value
₹86,700
Closing Date
3 May 2023, 6:00 pmClosed
CWE (AF) Agra
HQ CWE (AF) Agra PIN 282008
PROVN OF PARKING SHED NEAR NUCLEAR GATE AT AF STN SONEGAON
2023_MES_587909_1
80022-34/E8
Open Tender
Civil Works
Item Rate
180 days
AGE(I) (AF) Sonegaon
As per Tender documents
8 documents required · 8 mandatory
₹500
AGE(I) (AF) Sonegaon, Nagpur
₹86,700
Yes
7 Jul 2023
31 Mar 2023
10 May 2023
31 Mar 2023
3 May 2023
14 Apr 2023
Amount
Excavating over areas, n exc1.5 m deep and getting out soft/loose soil (Black cotton soil) complete all as specified and directed.
Excavating over areas, exc1.5 m deep and getting out soft/loose soil (Black cotton soil) complete all as specified and directed.
Removing excavated material exc. 50m but n exc. 100m and depositing where directed at a level n exc. 1.5 m above the starting point and depositing where direced etc complete all as specified and directed.
M&L for Moorum/red bajri filling in floors or pavings, laid in layers n exc. 15 cm thick, spread, levelled and rammed including watering complete all as specified and directed.
M&L for hardcore of broken stone gauge not exceeding 63mm,deposited, spread and levelled in layer not exceeding 30cm thick, watered and rammed to true surface complete all as specified and directed.
M&L 160mm thick Cement concrete type B-1,1:2:4 (20mm graded aggregate) for flooring laid in proper slope for self drainage complete all as specified and directed.
M&L 150mm thick cement concrete type C-2,1:3:6 (40mm graded aggregate) as in sub base laid in proper slope for self drainage complete all as specified and directed.
S&F MS Rolled sections as in main and cross columns and beams, rafters; purlins; fixed with angle cleats or other connecting plates Fe- 410 (Gde E-250 Quality A) complete all as specified and directed.
S &F mild steel screw bolt,11 to 15mm dia machine made with hexagonal head at one end and screwed the other or screwed both ends each screwed end to be filled with washer and one hexagonal or square nut exc 05cm and n exc10cm long complete all as specified and directed.
S&F 0.63 mm thick Galvanised, corrugated mild steel sheeting with two corrugations side lap, fixed with coach screws and washers, in roof , walls etc. with grade of zinc coating 275 etc complete all as specified and directed.
M&L for preparing the newly steel surface of any description not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint over one coat of red oxide primer all as specified and directed upto any hight and in any shade and colour complete all as specified and directed.
M&L for welding of metal having thickness n. exc. 6mm as and where is directed by Eng-in-charge (The quoted rates include for cleaning and preparing the surfaces holding the members in true position while welding and bevelling of edges, if required, in case of metal exc 3mm thick.) complete all as specified and directed.
M & L for cement concrete type B-2, 1:2:4 using 40mm graded aggregate as in foundation, filling and mass concrete complete all as specified and directed
M &L for Plain cement concrete in foundation filling type D-2 1:4:8 (40mm graded aggregate) and mass concrete complete all as specified and directed.
Use and waste of formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter for rough finished surfactes of concrete complete all as specified and directed.
Use and waste of formwork to sides of pillars, posts, struts, piers, columns and stanchions for rough finished surfaces complete all as specified and directed.
M&L for RCC M-25 nominal mix (using 20mm graded aggregate) in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and directed.
M&L for RCC M-25 nominal mix (20 mm graded aggregate) in Columns, pillars, piers, posts and struts complete all as specified and directed.
S&F for TMT bars 10mm dia and over as in reinforcement, cut to length, bent to shape required including cranking, bending spirally for hooping for columns,hooking ends and binding with and including mild steel wire(annealed) not less than 0.9mm dia or securing with clips quality conforming to IS complete all as specified and directed.
- Ditto- same as here-in - above item No-19 but by using 5mm dia and over up to and including 10mm dia in stirrups.
M &L for PVC casing capping surface point wiring with 1.5 Sqmm nominal area stranded copper conductor PVC insulated single core cable1100 Volts grade conforming to IS694 part-i including 600volts grade 1.5 Sqmm copper stranded single core cable green color PVC insulatedfor contineuous earthing wire complete with PVC fittings/ fixtures such as elbow,bends,couplers,tee,switch mounting box top covered with white hylam sheet,fixing screws mounting fitting/junction boxes etc and makig good of distrubed surfaces and to match with existing shade of wall/roof complete all as specified and directed. For the following:-
(a) One light point controlled by one switch
S&F switch piano, flush type single pole,5 Amps, 240 Volts AC complete all as specified and directed.
S&F ceiling rose surface backlight, 65x50mm, three terminals, 5 Amps,240 Volts AC complete all as specified and directed.
S&F sheet metal enclosure MCB DBs SPN 4 way 240 Volts Single door type powder coated with 200 Amps rated bus bar neutral link earth rail & din rail, ISI marked including MCBs of 20 Amps capacity, complete all as specified and directed.
S&F MCBs SPN 32 Amp 240/415 volts complete all as specified and directed.
S & F MCBs of capacities SP 06 Amp to 32 A 240 Volts complete all as specified and directed.
Supply and fix LED tube light fitting capacity 20 watt fixed on wall/surface / ceiling with all accessories including LED tube of 20 watt,driver,with surge protector complete & connecting to ceiling rose by using multi stranded flexible copper cable of size 3 core 1.5 sqmm complete all as specified and directed.. Make : CG Cat No CCS-100-20-65-HL2-DP-NWH/Havells/ Phillips/Bajaj
Excavation in trenches not exc 1.5 metre wide and not exc 1.5 metre in depth and getting out in any type of soil for laying of cable, pipes etc. complete all as specified and directed..
Returning, filling in and including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick complete all as specified and directed.
Removal of excavated materials (Soil) to a distance not exceeding 50 mtrs and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed.
M & L for fine dry sand for cushioning to under ground electric cable complete all as specified and directed. Note : Punned down thickness of sand shall be measured for payment.
Supplying & laying of bricks old pattern class 'B' for cable protection complete all as specified and directed..
Supplying & laying GI Tubing 40 mm dia Light grade pipe with connecting acessories complete laid in trench for road crossing and fixed on surface/,wall for protection complete all as specified and directed.
Earthing complete with galvanised earth plate electrode 60 cm x 60cmx 6 mm thick, buried directly in ground vertically (earth pit not less than 2.25 m deep below ground level) with top edge of the earth plate not less than 1.5m below ground level , connected to GI earth lead wire 4.0 mm dia by means bolts and nuts check nuts and washers of galvanized iron and connected to main switch board including watering arrangement by using 20 mm dia GI medium grade pipe and 20 mm dia GI light grade protection pipe with PCC chamber , MS funnel, wire gauge. CI cover with frame etc including necessary excavation in any type of strata , returning, filling removal of soil outside MD land ,filling of charcoal and salt complete all as shown in electrical plate No. 3 of MES Sch Part I , connected to Earthing test point all as specified and directed on testing on completion.
Supply and laying & testing and commisioning LT underground cable 1100 volts grade, XLPE insulated and PVC sheathed heavy duty armoured with multi staranded aluminium conductor laid in pipes, trenches/ducts, or fixed on poles etc of the under mentioned type and sizes complete all as specified and directed (a) 10 Sqmm x 2 core
PURVA ENTERPRISES
M/s Dara Constructions, Pulgaon
chronicle enterprises
M/s S. S. MUNDE
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .