| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.9 LAccepted-AOC 02 NERLE NERLE YEWALEWADI ROAD NERLE SANGLI MAHARASHTRA 415406 | SANGLI | MAHARASHTRA | 415406 | L1 | Accepted-AOC lowest | |
| 2 | L2₹33.1 L+₹5.0 L (17.9%)Rejected-Finance | L2 | Rejected-Finance RATE HIGH | |
| 3 | L3₹33.2 L+₹5.2 L (18.5%)Rejected-Finance 171 NARAYAN PETH PUNE PUNE MAHARASHTRA 411030 | PUNE | MAHARASHTRA | 411030 | L3 | Rejected-Finance RATE HIGH | |
| 4 | L4₹33.3 L+₹5.3 L (18.7%)Rejected-Finance SHOP NO 11 18 CITY CENTRE 930 931 SYNAGOGUE STREET PUNE 01 | L4 | Rejected-Finance RATE HIGH | |
| 5 | L5₹34.5 L+₹6.5 L (23.1%)Rejected-Finance FLAT NO 601 TOWER NO 30 SECTOR NO 21 AMANORA PARK TOWN HADAPSAR PUNE 411028 | PUNE | MAHARASHTRA | 411028 | L5 | Rejected-Finance RATE HIGH |
Tender Value
₹48 L
EMD Value
₹96,000
Closing Date
24 Aug 2023, 6:00 pmClosed
GE South Pune
NO 1 GEN BHAGAT MARG PUNE 411040
8459 REPAIR REPLACEMENT MAINTENANCE TO INTERNAL ELECTRIFICATION INCLUDING WIRING FITTINGS AND FIXTURES SUB MAIN WIRING DBS REPAIR TO SWITCH BOARD AND OTHER MISC ELECTRICAL WORK IN NEW CHSC AND OTHER CONNECTED AREA UNDER AGE E/M-II OF SOUTH PUNE
2023_MES_612257_1
8459 GE SOUTH PUNE
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE South Pune
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE SOUTH PUNE
₹96,000
6 Dec 2023
4 Aug 2023
26 Aug 2023
5 Aug 2023
24 Aug 2023
18 Aug 2023
Amount
Repair / maintenance of internal light fitting by deploying skilled labour i.e 01 skilled Electrician and o1 Helper to attend the complaints of “No light/ceiling fan/ exhaust fan/ geysers/ security light/ ceiling and wall light /Cable fault of any size & type / earth leakage/ short circuit / neutral break mains / substations / internal circuits of existing system of main building / block” and making continuous electric supply including carrying out minor repairs etc as required at site to make the system functional including replacing fuse wire, copper thimbles, glands, etc complete all as specified and all as directed by Engr-in-charge. Note: (i). Attending of one number of complaint, shall be measured as one job. (ii) Spare parts like Driver, lamp holder, connection wire, capacitor etc. replaced against above mentioned item will be measured & paid for separately under respective items of BOQ as “Supply only”. (iii) The contractor's representative i.e 01 skilled Electrician and o1 Helper will report to concerned JE E/M at 0900 hrs to 1700 hrs daily to collect the list of complaints and will submit the completion report on following day before 0900hrs to concern JE E/M. (iv) The contractor is responsible to rectify the electric defects/ faults and make the services functional within 24 hours from the time the list of electric defects/ faults is handed over to him / his rep by the concerned JE E/M. In case the light fitting is not made functional for whatsoever reason within the stipulated time limit, an amount of Rs 100/- per such electric defects/ faults per day will be recovered from the contractor’s dues i.e through RAR / Final Bill. (v) The contractor shall maintain proper record of repair / maintenance in a binded register duly bringing out the details of spares replaced on each and every light fitting and get it authenticated from concerned JE E/M on daily basis. The contractor shall put up the maintenance record register to Engineer-in-charge for inspection every Monday or as and when asked for.
Supply only modular Switch piano flush type, single pole, one way, and 6 Amp single module complete all as specified and directed.
Supply only Modular Switch piano flush type, single pole, one way, and 16 Amp single module complete all as specified. and directed.
Supply only Modular Socket outlet multipurpose having provision for 3 pin, 6 Amp and 2 pin, 6 Amp, 2 module piano flush type complete all as specified and directed.
Supply only Modular Switch Socket outlet multipurpose having provision for 3 pin, 16 Amp and 2 pin,6 Amp, 2 module piano flush type complete all as specified. and directed.
Supply only modular step type fan regulator 120 watt 2 module suitable for 230 volt 50 Hz AC supply complete all as specified and as directed.
Supply only for Bell push modular 6 Amps single module complete all as specified and directed.
Supply only Bell Electric Ding dong type suitable for operation on 230 volt 50 HZ A C supply complete all as specified and as directed
Supply only lamp holder insulated body with back plate PVC/Polycarbonate type with cord grip cap, angular type fixed on wall complete all as specified and directed.
Supply only Ceiling rose, surface Bakelite suitable ISI marked complete all as specified and directed.
Supply only Switch piano flush type, single pole, one way, and 5 Amp complete all as specified and directed.
Supply only switch piano flush type, 15 Amps single pole one way fixed and connect as per existring complete all as specified and directed.
Supply only Socket outlet multipurpose having provision for 3 pin, 5 Amp piano flush type complete all as specified and directed.
Supply only socket outlet 5/15 Amp multipurpose and with, 15 Amps single pole one way complete all as specified and directed.
S & F in replacement of switch socket combination with box 5/6 Amps flush mounted 5 pin multi purposecomplete all as specified and directed.
S & F in replacement of switch socket combination with box 5/15 Amps flush mounted 3/5 pin multi purpose complete all as specified and directed.
Taking down carefully exising unserviceable point wiring of any type (light, fan, socket or power), complete (fitting such as switches,ceiling rose, pendent, regulators etc) for taking credit and making good disturbed surfaces of wall, floor etc. complete all as specified and as directed.
M & L for Point wiring using approved colour coding as per IS, with multi-stranded copper conductor 1.5 Sq. mm (nominal area), single core, PVC insulated and unsheathed FRLS cable 1100 volts grade, ISI-694 marked drawn through in and including heavy duty, PVC casing capping including all accessories etc, heavy duty ISI marked, concealed / surface mounted as per site requirement with mild steel sunken boxes / PVC surface mounted box with earth dolly duly, covered with laminated hylem sheet/ PVC cover, ISI marked suitable for fixing of switches, fan regulators and sockets including PVC insulated multi-stranded copper conductor 1.5 Sqmm (nominal area) single core FRLS cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed for the following :- (a) One light point controlled by one, one way switch 5 Amps.
(b). One fan point/ exhaust fan point controlled by one, one way switch 5 Amps
(c). One 3 pin 5 Amps switch socket outlet point controlled by one switch on independent boad.
(d). One bell point controlled by bell switch 5 Amps
(e). One 3 point 5 Amps switch socket outlet point controlled by one switch on the same board.
All as per item no. 18 above but using 2.5 sq mm single core copper conductor cable for 5/15 amps point including 2.5 sq mm copper conductor as earth continuity conductor, complete all as specified and directed
M & L for Point wiring with colour coding as per IS, with multi-stranded copper conductor 1.5 Sq.mm nominal cross sectional area, single core, 1100 Volts grade, multi stranded, FRLS- Cable conforming to IS: 694-1990 PVC insulated, unsheathed copper conductor cable drawn through in and including heavy duty PVC concealed conduit of white/ ivory colour including all accessories after cutting chasing in wall of any type /ceiling etc, including making good of disturbed surface and finish with two coats of white / colour washing / distempering etc to match the existing surface complete etc heavy duty ISI marked, with GI sunken boxes with earth dolly duly, covered with modular white cover plate with frame suitable for modular switches including PVC insulated multi-stranded copper conductor 1.5 Sqmm (nominal area) single core FRLS cable as earth continuity conductor to common earth and connecting to earth dolly all as specified and directed for the following :- (a). One light point controlled by one, one way switch 5 Amps
(b). One fan point/ exhaust fan point controlled by one, one way switch 5 Amps
(c). One light point controlled by two way switches 5 Amps.
(d). One 3 pin 5 Amps switch socket outlet point controlled by one switch on independent boad.
(e). but One bell point controlled by bell switch 5 Amps.
(f). One 3 point 5 Amps switch socket outlet point controlled by one switch on the same board.
All as per item no. 24 above but using 2.5 sq mm single core copper conductor cable for 5/15 amps point including 2.5 sq mm copper conductor as earth continuity conductor, complete all as specified and directed
M & L for Sub main wiring with approved colour coding as per IS with four single core PVC insulated FRLS cable with stranded copper conductor of size with 10 Sqmm , 1100 Volts grade, stranded, PVC insulated, unsheathed, copper conductor FRLS- confirming to IS: 694-1990 with and including continuous earth wire of size 1x10 Sqmm nominal cross sectional area, single core, PVC insulated, copper conductor cable drawing into and including rigid non-metallic PVC non-metallic rigid heavy duty PVC conduit of suitable size of white/ ivory colour and its accessories ISI marked of suitable size concealed in wall etc and connected to common earth dolly including all cutting / chases etc in any type of wall and making good the disturbed surfaces walls by applying two coats of white / colour washing / distempering etc. to match the existing complete all as specified & directed. Note:-One meter length of conduit, 4 runs of 10 sq mm stranded copper conductor cable and 01 run of 10 sq mm stranded copper conductor cable as in earth shall be measured as one unit length.
M & L for Sub main wiring with approved colour coding as per IS with four single core PVC insulated FRLS cable with stranded copper conductor of size with 6 Sqmm , 1100 Volts grade, stranded, PVC insulated, unsheathed, copper conductor FRLS- confirming to IS: 694-1990 with and including continuous earth wire of size 1x6 Sqmm nominal cross sectional area, single core, PVC insulated, copper conductor cable drawing into and including rigid non-metallic PVC non-metallic rigid heavy duty PVC conduit of suitable size of white/ ivory colour and its accessories ISI marked of suitable size concealed in wall etc and connected to common earth dolly including all cutting / chases etc in any type of wall and making good the disturbed surfaces walls by applying two coats of white / colour washing / distempering etc. to match the existing complete all as specified & directed. Note:-One meter length of conduit, 4 runs of 6 sq mm stranded copper conductor cable and 01 run of 6 sq mm stranded copper conductor cable as in earth shall be measured as one unit length.
M & L for Sub main wiring with approved colour coding as per IS with two single core PVC insulated FRLS cable with stranded copper conductor of size with 6 Sqmm , 1100 Volts grade, stranded, PVC insulated, unsheathed, copper conductor FRLS- confirming to IS: 694-1990 with and including continuous earth wire of size 1x6 Sqmm nominal cross sectional area, single core, PVC insulated, copper conductor cable drawing into and including rigid non-metallic PVC non-metallic rigid heavy duty PVC conduit of suitable size of white/ ivory colour and its accessories ISI marked of suitable size concealed in wall etc and connected to common earth dolly including all cutting / chases etc in any type of wall and making good the disturbed surfaces walls by applying two coats of white / colour washing / distempering etc. to match the existing complete all as specified & directed. Note:-One meter length of conduit, 2 runs of 6 sq mm stranded copper conductor cable and 01 run of 6 sq mm stranded copper conductor cable as in earth shall be measured as one unit length.
M & L for Sub main wiring with approved colour coding as per IS with two single core PVC insulated FRLS cable with stranded copper conductor of size with 4 Sqmm , 1100 Volts grade, stranded, PVC insulated, unsheathed, copper conductor FRLS- confirming to IS: 694-1990 with and including continuous earth wire of size 1x4 Sqmm nominal cross sectional area, single core, PVC insulated, copper conductor cable drawing into and including rigid non-metallic PVC non-metallic rigid heavy duty PVC conduit of suitable size of white/ ivory colour and its accessories ISI marked of suitable size concealed in wall etc and connected to common earth dolly including all cutting / chases etc in any type of wall and making good the disturbed surfaces walls by applying two coats of white / colour washing / distempering etc. to match the existing complete all as specified & directed. Note:-One meter length of conduit, 2 runs of 4 sq mm stranded copper conductor cable and 01 run of 4 sq mm stranded copper conductor cable as in earth shall be measured as one unit length.
M & L for Sub main wiring with approved colour coding as per IS with two single core PVC insulated FRLS cable with stranded copper conductor of size with 04 Sqmm nominal cross sectional area, 1100 Volts grade, stranded, PVC insulated, unsheathed, copper conductor FRLS- confirming to IS: 694-1990 with and including continuous earth wire of size 2.5 Sqmm nominal cross sectional area, single core, PVC insulated, copper conductor cable and including ISI marked PVC casing capping including fitting in wall etc. and connected to common earth dolly and making good the disturbed surfaces walls by applying two coats of white / colour washing / distempering etc. to match the existing complete all as specified & directed. Note:-One meter length of casing capping, 2 runs of 4 sq mm stranded copper conductor cable and 01 run of 2.5 sq mm stranded copper conductor cable as in earth shall be measured as one unit length.
M & L for Sub main wiring with approved colour coding as per IS with two single core PVC insulated FRLS cable with stranded copper conductor of size with 6 Sqmm nominal cross sectional area, 1100 Volts grade, stranded, PVC insulated, unsheathed, copper conductor FRLS- confirming to IS: 694-1990 with and including continuous earth wire of size 6 Sqmm nominal cross sectional area, single core, PVC insulated, copper conductor cable and including ISI marked PVC casing capping including fitting in wall etc. and connected to common earth dolly and making good the disturbed surfaces walls by applying two coats of white / colour washing / distempering etc. to match the existing complete all as specified & directed. Note:-One meter length of casing capping, 2 runs of 6 sq mm stranded copper conductor cable and 01 run of 6 sq mm stranded copper conductor cable as in earth shall be measured as one unit length.
M & L for Sub main wiring with approved colour coding as per IS with four single core PVC insulated FRLS cable with stranded copper conductor of size with 6 Sqmm nominal cross sectional area, 1100 Volts grade, stranded, PVC insulated, unsheathed, copper conductor FRLS- confirming to IS: 694-1990 with and including continuous earth wire of size 6 Sqmm nominal cross sectional area, two single core, PVC insulated, copper conductor cable and including ISI marked PVC casing capping including fitting in wall etc. and connected to common earth dolly and making good the disturbed surfaces walls by applying two coats of white / colour washing / distempering etc. to match the existing complete all as specified & directed. Note:-One meter length of casing capping, 4 runs of 6 sq mm stranded copper conductor cable and 02 runs of 6 sq mm stranded copper conductor cable as in earth shall be measured as one unit length.
M & L for Sub main wiring with approved colour coding as per IS with four single core PVC insulated FRLS cable with stranded copper conductor of size with 10 Sqmm nominal cross sectional area, 1100 Volts grade, stranded, PVC insulated, unsheathed, copper conductor FRLS- confirming to IS: 694-1990 with and including continuous earth wire of size 6 Sqmm nominal cross sectional area, two single core, PVC insulated, copper conductor cable and including ISI marked PVC casing capping including fitting in wall etc. and connected to common earth dolly and making good the disturbed surfaces walls by applying two coats of white / colour washing / distempering etc. to match the existing complete all as specified & directed. Note:-One meter length of casing capping, 4 runs of 10 sq mm stranded copper conductor cable and 02 runs of 6 sq mm stranded copper conductor cable as in earth shall be measured as one unit length.
Taking down carefully sub main wiring of any type and size and making good disturbed surfaces complete all as specified and directed.
S&F in replacement armoured copper conductor cable PVC insulated, 3 core, 4.0 Sqmm with stranded copper conductor, 1100V grade complete all as specified and as directed
S&F in replacement armoured copper cable PVC insulated single core 16.0 Sqmm with stranded copper conductor, 1100V grade, complete all as specified and as directed
S&F in replacement PVC insulated cable, 2 core, stranded copper conductor, 0.5 sqmm, FRLS, complete all as specified and directed.
S&F in replacement PVC insulated cable, 2 core, stranded copper conductor, 1 sqmm, FRLS, complete all as specified and directed.
Supply, installation, commissioning and testing of chemical earthing for GI pipes one inside the other with proper galvanization. The outer dia shall be of 88 mm & inner dia shall be of 48 mm and the cavity filled with highly conductive, non-corrosive material with additional copper coating on the outer surface including with supply of fast electrode earth enhancement compound (2 bags of 25 Kg Each) which is highly hygroscopic, non-corrosive & good PH value certified by NABL approved lab and including copper earth plate 90x60 cmx5 mm and copper earth strip 32x6 mm (with nuts, bolts & check nuts) and riveted to earth electrode at one end and connected to metallic bodies of equipment’s etc at the other, earth strip encased in and including 40mm bore GI pipe medium grade including with all fittings & fixtures from top of electrode to body of equipment fixed with and including 40 x 6mm flat iron clamps, bolts, nuts and washer complete with earth pit in PCC 1:2:4 type B-O using 12 mm graded crushed stone aggregate, RCC cover, funnel, wire mesh including necessary excavation and earth work etc. complete all as specified and directed by Engr-in-charge. Note : 1. The earthing result should not be less than 1 ohm and testing equipment shall be provided by contractor without any extra cost to the Department. 2. The cost of GI strip and GI pipe 40mm bore medium grade for encasing GI strip up to 7.50m length per earthing shall be deemed to be included in unit quoted rates.
M&L for Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit / pipe or fixed to poles or any other indicated situation for loop earthing etc as required for 32x6 galvanized iron strip, complete all as specified and directed.
M & L For fixing earth continuity conductor or main earth lead fixed to wall or buried in ground or drawn in GI pipe with 4 sqmm GI Wire complete all as specified and directed.
S&F in repair, Metal plug and socket -2 pin and earth plug and socket including with 20 Amps MCB SP concealed / surface on wall as per site requirement including all cutting holes in or through walls, making good the disturbed surfaces walls by applying two coats of white / colour washing / distempering etc. to match the existing complete all as specified & directed. Make - L&T or equivalent in Legrand/ABB/Schenider
S&F in repair, triple pole and earth enclosure with a three pin and earth plug with socket complete with one triple pole, 32 Amps, MCB TP concealed / surface on wall as per site requirement including all cutting holes in or through walls, making good the disturbed surfaces walls by applying two coats of white / colour washing / distempering etc. to match the existing complete all as specified & directed. Make - L&T or equivalent in Legrand/ABB/Schenider
S&F in replacement factory made epoxy powder coated Distribution Board TP & N 4 way double door (VTPN MCCB DB) MCCB as In comer, and MCB as outgoing with metal door (IP-43 protection) fabricated from CRCA sheet and fixed semi flush to wall and suitable for universal mounting and including 200 Amp copper bus bar, neutral bar, standard DIN rail, Earth bar and cable ties for cable management, top and bottom removable gland plates with Knockout semi flush to wall and making good the disturbed surfaces walls by applying two coats of white / colour washing / distempering etc. to match the existing complete all as specified & directed. Note:- MCCBs and MCBs will be measured and paid separately under respective BOQ.
All as per item no 49 above but TP & N 8 way double door (VTPN MCCB DB), complete all as specified & directed.
All as per item no 49 above but TP & N 12 way double door (VTPN MCCB DB), complete all as specified & directed.
S&F in repair IP-43, protection metal double door Vertical TPN -DB rated bus bar, 415 volts, 50 HZ complete with interconnection links, blanking plates, cable ties, identification labels TPN 4 ROW of 10 modules suitable for accommodating up to 40 nos. SP/ TP/ TPN MCB as Incoming / outgoing and concealed /surface on wall as per site requirement including all cutting holes in or through walls, making good the disturbed surfaces walls by applying two coats of white / colour washing / distempering etc. to match the existing complete all as specified & directed.
S&F in replacement MCB DB sheet metal enclosure factory made suitable for MCB DB's 240 volts with 200 amp rated bus bar, neutral & earthing link bar, flush / surface mounting complete including taking down the existing DB of any type & size by removing from existing circuits and S&F of new 04 way SPN DB (double door) and circuits complete as required at site making good the disturbed surfaces walls by applying two coats of white / colour washing / distempering etc. to match the existing complete all as specified & directed.
All as per item no 53 above but 08 way SPN DB (Double door), complete all as specified & directed.
All as per item no 53 above but 12 way SPN DB (Double door), complete all as specified & directed.
S&F in replacement MCCB with rating of 63-100 Amps, 415 Volts, 4 pole with 16kA breaking capacity, thermal magnetic adjustable of overload & short circuit release as per IS-13947 & IEC 60947-2 & the service short circuit breaking capacity (Ics) should be equal to ultimate breaking capacity (Icu), MCCB should be with suitable spreaders and phase barriers for each terminals, complete all as specified & directed.
All as per item no 56 above but MCCB 125 Amps, 16 KA, 4 Pole,415V, complete all as specified & directed.
All as per item no 56 above but MCCB 160 Amps, 25 KA, 4 Pole,415V, complete all as specified & directed.
All as per item no 56 above but MCCB 200 Amps, 25 KA, 4 Pole,415V, complete all as specified & directed.
All as per item no 56 above but MCCB 250 Amps, 25 KA, 4 Pole,415V, complete all as specified & directed.
S&F in replacement MCB SP 6-32 Amps,10KA,'C' series complete all as specified and as directed.
S&F in replacement MCB SPN 20-40 Amps, 10KA, 240V, 'C' series complete all as specified and as directed.
S&F in replacement MCB TP 40/63 Amps ,10KA, 415 V, 'C' series complete all as specified and as directed.
S&F in replacement MCB TPN 40/63 Amps ,10KA, 415V, 'C' series complete all as specified and as directed.
S&F in replacement RCCB 40 Amps, 100mA, 2 Pole, 240V, complete all as specified and as directed.
Supply and fixing in replacement PVC fresh air fan 250mm sweep complete all as specified and as directed. (Make :- Bajaj / cromptan / Havells /Usha )
S&F in replacement white cover plate with frame 2 module, complete all as specified and as directed. Make:- As per the sample held with AGE office.
S&F in replacement white cover plate with frame 3 module, complete all as specified and as directed. Make:- As per the sample held with AGE office.
S&F in replacement white cover plate with frame 4 module, complete all as specified and as directed. Make:- As per the sample held with AGE office.
S&F in replacement white cover plate with frame 6 module, complete all as specified and as directed. Make:- As per the sample held with AGE office.
S&F high speed wall mounted fan of sweep 400 mm, copper winded motor, auto thermal overload protection, compact style and powder coated guards & pull cord switch for speed regulation and oscillation control including connecting up the power cord to the socket with necessary fixing accessories complete all as specified and directed.
Taking down ceiling fan / exhaust fan of any sweep for servicing / repairing / maintenance, opening up, identifying and replacing the defective parts, cleaning, greasing etc. complete and reassembling and hanging up / fixing back at its original position and making all electric connections after testing to ensure smooth functioning of the same complete all as directed by Engr-in-charge. Note :- Spares parts such as capacitors, bearings etc. will be measured and paid for separately under respective Item of BOQ as “Supply only”
Supply only bearing No.6201/6202/6203 or any other No. matching to the existing size and suitable for ceiling fan / exhaust fan / wall mounted fan, complete all as directed by Engr-in-charge. Make:- SKF or equivalent make.
Supply only capacitor of 2.5 mfd suitable for ceiling fan / exhaust fan, complete all as directed by Engr-in-charge. Make:- Tibcon/Epcos/Havells
Supply only capacitor of 4 mfd suitable for ceiling fan / exhaust fan, complete all as directed by Engr-in-charge. Make:- Tibcon/Epcos/Havells
M&L for replacement of burnt winding of Ceiling fan 1200/1400mm sweep, working on 230 volts AC supply and re-winding complete with super enamelled copper wire of same gauge and weight, replacement of insulation paper, varnishing, heating up and testing complete including taking down and re-fixing the fan at its original position, complete all as directed by Engr-in-charge.
Al as per item no. 76 above but Exhaust fan upto 250/300/450 mm sweep working on 230 volts AC supply, complete all as directed by Engr-in-charge.
All as per item no. 76 above but Wall mounting fan of any 230/450 mm size, working on 230 volts AC supply, complete all as directed by Engr-in-charge.
S&F in repairs of fan blade (set of 3) suitable for 1200 mm ceiling fan of existing make complete all as specified and as directed.
S&F high speed pedastal fan of sweep 400 mm, copper winded motor, complete all as specified and directed.
Supply and fix in replace anchor bolt & nut 8 mm dia suitable for fixing of geyser on walls in a suitable way and making good the distrubed area complete all as specified and directed
Supply only self adhesive PVC electrical Insulation tape 7 mtr long, ISI mark with superior quality complete all as specified and as directed.
Supply and fix in replacement MS clamp with rubber reel, nuts, bolts, split pin etc. suitable for 1200/1400 mm sweep ceiling fan complete all as specified and as directed.
S&F in replacement down rod, 2 feet long suitable for 1200/1400 sweep ceiling fan, made out of GI pipe medium grade 15mm dia with fan clamps including drilling cutting threding etc complete all as directed.
All as per item no. 84 above but 3 ft long, complete all as directed.
All as per item no. 84 above but 4 ft long, complete all as directed.
Disconnecting and taking down of existing unserviceable geyser of 25 ltrs capacity of any make / brand, taking it to civil workshop for repairing, servicing, cleaning etc, replacement of thermostat, heating element, indicator lamp and thermal cut out including fixing of PVC cable, sheathed, three core with stranded copper conductor of size 2.5 sqmm and re-fixing the geysers at its original location, complete all as directed by Engr-in-charge. Note:- Heating element, thermostat, indicator lamp & thermal cut out etc. shall be measured and paid separately as “Supply only” under respective items of BOQ.
Supply only heating element 2 KW, 230 volt round/ triangular in shape, ISI marked, complete all as specified and as directed.
Supply only Indicating lamp (red/green/yellow) complete suitable for geyser of any capacity complete all as specified and as directed.
Supply only thermostat and cut out set electronic type, temperature adjustable from 0-80⁰C suitable for geyser of 25 ltrs capacity, complete all as specified and as directed.
S&F in replacement GI mesh hot water connection 600/900 mm long including necessary washers suitable for geysers of various capacities complete all as specified and directed.
S&F in repairs cable PVC insulated 3 core 2.5 Sqmm with stranded copper conductor 1100V grade from socket / switch to geyser complete all as specified and as directed.
Supply & fix in replacement 15A plug top and connection complete all as specified and as directed.
S & F in repairs LED indoor driver suitable for LED fitting 10 to 35 Watts of the existing make including connection etc. complete all as specified and directed.
S & F in repairs LED indoor driver sutable for LED pannel recess mounted 2'x2' and 36 watts light of the existing make including connection complete all as specified and directed
S & F in repairs LED indoor Surge Protection Device suitable for LED panel recess mounted -2'x2' - 36 watts light of the existing make including connection complete all as specified and directed
Supply only retrofit 4 pin, 18/20 watt LED PL-L with direct plug and play suitable for installation in existing 2G11 lamp holders, complete al as directed.
S&F in replacement recess mounted 2' x 2' LED Panel lights 40 W LED 5700K, 240Volts and glare free symmetrical illumination suitable for Armstrong / Grid ceiling opeings, Environmental friendly, new generation, energy saving, high power LED as a light source with clear diffuser and separate replaceable electronic driver including connecting with twin core wire and also matching the disturbed ceiling surfaces and to the adjacent ceiling surfaces carefully complete all as specified and directed. Make:- Havells Cat part No.PLUTONEO 2X2 PLR42W LED 8575 / PHILIPS CAT PART NO. RC380B LED 365-6500GAL60 W60 PSD OD WHDC / LUKER CAT PART NO. LKM2240"
S&F in replacement of 18/20 watt, 230V surface and wall mounted LED batten, extruded aluminium housing with polycarbonate diffuser and integrated electronic driver including connecting up with twin core twisted flexible copper conductor cable from ceiling rose complete all as specified and directed.
S&F in replacement 1x10 watt, 230V surface and wall mounted LED batten suitable for mirror light with polycarbonate housing and integrated electronic driver including connecting up with twin core twisted flexible copper conductor cable from ceiling rose complete all as specified and directed. Make:- Bajaj Cat part No. BCLAB20WWHLEDP / Havells act part No. ENDURA LINEAR NEOBS 20W LED 865SPCWH / LUKER CAT PART NO. LTSM20"
Supply & fix in replacement LED recess mounting down lighter with ceiling cut out of 153mm dia of wattage 12 watt with LED backlit round down lighter made of PDC AL with high efficient LEDs & glare free opal diffuser, IP20 including taking down old unserviceable light complete all as specified and directed.
Supply & fix in replacement LED fixture 30 watt environment friendly, energy efficient, aesthetically designed, surface mounted ceiling light with diffuser to give glare free light, complete all as specified & directed. Make:- Havells Cat part No.PLUTOSURFACE 2X2 PLR42W LED 8575 / PHILIPS CAT PART NO. SM365 LED 32-6500 PSU OD WH / LUKER CAT PART NO. LNPSRS 30"
S&F in replacement recess type LED ceiling lights 20 W LED with ceiling cut out of Ø 160 - 200 mm Environmental friendly, energy saving, recess mounted down lighter with separate replaceable electronic driver including connecting with twin core wire, including cutting the existing false ceiling in required dia and also matching disturbed surfaces to the adjacent false ceiling surfaces carefully complete all as specified and directed. Make:- Jaquar LARV G R018xC / LUKER CAT PART NO. LDR 20 / Havells EDGE PRO"
S&F in replacement recess mounted 2' x 2' LED clean room lights 36-42 W LED 5700K, 240Volts and glare free symmetrical illumination, Environmental friendly, new generation, energy saving, high power LED as a light source with clear diffuser and separate replaceable electronic driver including connecting with twin core wire and including making good the disturbed surfaces of ceiling to the adjacent ceiling surfaces carefully complete all as specified and directed.
shiva traders
KESARI AND SONS
PROLINK COMPUTERS
UNIQUE ENGINEERS
TULAJA ENTERPRISES
Anand Trading Co
M/S - SUJIT ELECTRICALS
ANUSHKA BUILDERS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .