Tender Value
₹8 L
EMD Value
₹16,000
Closing Date
21 Jun 2024, 3:00 pmClosed
Executive Officer
Town Panchayat Harur
Providing New Bore well with Power Pump arrangement and Pumping line to Peechankottai SLUM Housing Unit in Harur Town Panchayat.
2024_DTP_454578_1
1427/2023/A1
Open Tender
Civil Works
Works
30 days
Harur
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
₹16,000
28 Jun 2024
14 Jun 2024
21 Jun 2024
14 Jun 2024
21 Jun 2024
14 Jun 2024
Amount
Geo physical survey chargesAmount payable to Geology survay report for locating of bore point including all labour and materials etc complete.
Drilling of 150mm (6") dia vertical clear bores in hard rode in any habitation to required depth on directed by the offices concred including labour charges for insuting PVC casing pipes as per standard specification.Drilling of 150mm(6") dia Vertical clear bores in Hard rock in any habitation any where in Erode District to any required depth as directed b y the officers concerened including labour charges for inserting M.S/P.V.C Casing pipes to any reauired depth , assembilling in the drilled hole including welding joints if necessary Grouting the cassing pipes including conducting proper yield test at final depath (by provinding 90 ' V' Notch fitted in a formed channel and the correct yield at the time of free flow in the channel while flushing the bore after completion of drilling process should be ascertained of and reported )including Bore cover transportation. crew and fuel charges for rigs and supporting Vechicles from one place to another etc Complete and as directed by officers Concernedupto 150m Pipe depth
Above 150 m Pipe depth
Supply of 200mm OD PVC 6 KSC casing pipe as per standard specification
Supply and delivery of wet type 75LPMx225m Headx3.00HP submersible pumpset with motor and confirming to IS8034/2002 and IS 9283/79 with ISI marking as per standard specification
Three phase panel board with two level guard and auto atrot as per standard specification. The pump set should be supplied with 5M flat submersible copper cable.
Supply and delivery of 4.00 sq mm Flat type Copper Water Proof cable conforming to IS 694/1990 including all cost of metrials and labour etc as per std specification
Supply and delivery of following pipe pipe line materials(with ISI mark) etc complete. 50 mm GI pipe with B class
50mm dia G.I Elbow
50mm G.I Coupling
50mm G.M Non Retrun valve
50mm dia G.I union
65mm GI pipe with coupler medum class
75mmDia 6KSC PVC Pipe
75mm Dia PVC Bend 6KSC
80mm Air Valve
50mm Dia Flange Set
65mmX90mm PVC THREADED COUPLER
Labour charge for the erection of submersible pump set in bore well including fixing and joint submersible cable with proper clamps upto stater to require depth and also fixing of raiser pipes to the required depth valve erection clamp pressure gauges upto the exterior wall of pump room and erection of panel board consisting of TPICN switches starter Voltmeter, Ammeter, three pilot(indicating) lamps capacitor single phase preventor, water level guard and laying and jointing the cable and twin earthing as per IS rules etc complete.
Supply and fixing of following electrical materials S& Fixing of M.S bore well Dummy
S&F M.S bore clamp
50MM GI Pipe Cutting
50mm GI Pipe Threading
65mm GI Pipe Cutting
65mm GI Pipe Threading
Supply and delivery of MS Kiosk of size 0.75m x 0.45m x 0.75m made up of MS angle of size 50mm x 50mmx 4mm alround covered with 16 gauge MS sheet and kiosk door made up of MS plates of size 25 mm x 3 mm including cutting, welding, grinding, locking arrangements and labour charges etc
Supply and Run of 2x4 sq.mm(84/0.3) PVC insulated Sc unsheathed Cu.Conductor of 1100V grade in 25mm dia G.I pipe (Bclass) suitable bend at both ends with necessary angle iron up right and end supports for mains.
Supply and run of 2 of 6 sq.mm. (84 / 0.3) PVC insulated SC unsheathed copper conductor of 1100V on 7 / 20 GI bearer wire for service connection mains SC 66
Earth work excavation for foundation in all soils andSub soils and to full depth as may be directed hardRock requiring blasting inclusive of shoring,Shuttering and celing out water wherever necessaryRefilling the sides of foundation with excavatedEarth in layers of 15cm thick well rammed andConsolidated, depositing the surplus earth withinThe compound in places shown by the departmentalOfficers with initial lead and lift and clearing and Levelling the site etc., complete
Plain Cement Concrete 1:4:8 Mix (one part cement, Four part M.sand and Eight part of aggrigate) using 40mm size ISS HBG metal machine crushed from approved quarry including cost and conveyance of all materials to site, loading and unloading charges and labour charges for mixing, laying and curing etc. complete. Complying with std. specifications.
Brick Work in Cement Mortor 1:5 Mix (one cement, five sand ) using new best country Bricks of size 8 ¾” x 4 ¼” x 2 ¾” from approved quarry including cost and conveyance of all materials to site. loading and unloading charges and labour charges for mixing, laying and curing etc. complete. complying with std. specifications.
Plastering with cement mortar 1: 5 ( one cement and five P.Sand) mix to 12mm thick including cost and conveyance of all materials to site including curing etc.,complete as per standard specification – 10m2
Cement paint two coats of approved colour and quality including preparation of plastering wall surface , finishing neatly and all other labour ,materials cost etc complete as per std specification.
Refilling the trench with excavated earth other than sand including cost and conveyance of all other labour and material charges to site etc., complete complying with standard specifications.
Kumaresan Contractor
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .