Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹22.3 LAccepted-AOC 6 2 B 1 SHASTRI NAGAR KHANDARI AGRA UTTAR PRADESH 282002 | AGRA | UTTAR PRADESH | 282002 | 1 | Accepted-AOC due to credit | |
| 2 | 2₹26.9 L+₹4.1 L (17.8%)Rejected-Finance | 2 | Rejected-Finance Being other than L-1 | |
| 3 | 3₹28.8 L+₹6.0 L (26.1%)Rejected-Finance | 3 | Rejected-Finance Being other than L-1 |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
13 Oct 2022, 6:00 pmClosed
GE (AF) Adm Area Agra 282008
GE (AF) Adm Area Agra 282008
REPAIR AND MAINT OF INTERNAL WIRING INCL FITTING FIXTURE AND OTHER CONNECTED WORK IN CERTAIN OFFICERS MD ACCN AND IN SMQS AT DSML ML DSNP AREA UNDER GE AF ADM AREA AGRA
2022_MES_552667_1
8000-2001/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
AF Station Agra
Class D
Cat b i
8 documents required · 8 mandatory
₹500
GE AF Adm Area Kheria Agra
₹60,000
Yes
4 Nov 2022
17 Sept 2022
15 Oct 2022
17 Sept 2022
13 Oct 2022
1 Oct 2022
17 Sept 2022 - 30 Sept 2022
Amount
Taking down copper/ aluminium point wiring (light, fan, socket or power) complete including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc. removing materials to store for keeping in safe custody or for taking credit and making good disturbed surfaces of walls, floors etc. to match the existing complete all as specified and directed. NOTE: Credit for this items shall be made as per conditions separately.
M&L for point wiring complete for one light/fan/ exhaust fan point controlled by one, one way 5 Amp switch with PVC (FRLSH) insulated unsheathed multistranded copper conductor of size 1.50 sqmm nominal cross sectional area single core drawn in and including minimum 20 mm dia 'medium grade' PVC concealed conduits ISI marked and fittings, including anodised pressed steel concealed terminal switch boxes not less than 1.20 mm thick of reqd size factory made duly painted inside and outside with one coat red oxide primer, 3mm thick plastic laminated bakelite sheet top cover (ISI Marked) fitted with chromium plated brass screws & washers complete including 1.50 sqmm nominal cross sectional area PVC(FRLSH) insulated unsheathed multistranded copper conductor green as earth wire connected to earth dolly with all accessories including cutting chases for concealed piping and making good disturbed surface to match the existing surface complete all as specified and directed.
All as per item No. 02 above but for One bell/ buzzer point on an independent board controlled by one bell push
All as per item No. 02 above but for one 5 pin 5 Amp socket outlet point on an independent board.
All as per item No. 02 above but for one 5 pin 5 Amp socket outlet point on the same board with other switch.
All as per item No. 02 above but for one light point controlled by two Nos. two way switch 5 Amp socket outlet point on the same board with other switch.
All as per Item No 02 above but for one 6 pin 15/16 amps socket outlet point on an independent board with cables of size 2.50 Sqmm and green colour earth cable of size 2.50 Sqmm.
M&L for point wiring complete with PVC (FRLSH) insulated unsheathed multistranded copper conductor of size 4 sqmm nominal cross sectional area single core drawn in and including not less than 20 mm dia 'medium grade' PVC concealed conduits ISI marked and fittings, complete including 4 sqmm nominal cross sectional area PVC(FRLSH) insulated unsheathed multistranded copper conductor green as earth wire connected to earth dolly with all accessories including cutting chases for concealed piping and making good disturbed surface to match the existing surface complete all as specified and directed.
S&F Switch piano, flush type, single pole, one way 5/6 Amp 230 Volts complete all as specified and directed.
S&F Switch piano, flush type, single pole, two way 5/6 Amp 230 Volts complete all as specified and directed.
S&F bell push, flush type, single pole, one way 5/6 Amp, 230 volt flush type complete all as specified and directed.
S&F Switch piano, flush type, single pole, one way 15/16 Amp 230 Volts complete all as specified and directed.
S&F socket outlet, flush type, single pole, 2 in 1, 5 pin 5/6 Amp, 230 volts complete all as specified and directed.
S&F socket outlet, flush type, single pole, multipurpose 2 in 1, 6 pin 5/6 and 15/16 Amp, 230 volts complete all as specified and directed.
S&F call bell, ding dong type, AC single pole, 230 volt complete all as specified and directed.
S&F ceiling rose, 3 terminal, PVC/ Polycarbonate, insulated body, surface bakelite sheet 63.50 mm dia complete all as specified and directed.
S&F ceiling fan regulator, electronic, socket type, 5 speed 230 volts suitable for 1200/1400 mm sweep ceiling fan including necessary connection complete all as specified and directed.
S&F Lamp holder/ angle holder PVC/ Polycarbonate type with back plate suitable for batten fittings complete all as specified and directed.
M&L for point wiring complete for one light/fan/ exhaust fan point controlled by one, one way 5 Amp switch with PVC (FRLSH) insulated unsheathed multistranded copper conductor of size 1.50 sqmm nominal cross sectional area single core drawn in and including minimum 20 mm dia 'medium grade' PVC concealed conduits ISI marked and fittings, including concealed terminal switch boxes for modular switches, modular plate and cover of suitable size for fixing switchs, sockets, regulators etc. including 1.50 sqmm nominal cross sectional area PVC(FRLSH) insulated unsheathed multistranded copper conductor green as earth wire connected to earth dolly with all accessories including cutting chases for concealed piping and making good disturbed surface to match the existing surface complete all as specified and directed. Note- (i) Rates include the cost of modular plate modular boxes and covers of suitable modules as required at site. (ii) Modular box, plate and cover shall be of same make as of switch//socket/regulator.
All as per item No. 19 above but for one 5 pin 5/6 Amp socket outlet point on an independent board.
All as per item No. 19 above but for one 5 pin 5/6 Amp socket outlet point on the same board with other switch.
All as per Item No 19 above but for one 6 pin 15/16 amps socket outlet point on an independent board with cables of size 2.50 Sqmm and green colour earth cable of size 2.50 Sqmm.
S&F modular type switch one way 6 Amps with led indication lamp 240 Volt, 1 Module complete all as specified and directed.
S&F modular type switch one way 16 Amps with led indication lamp 240 Volt, 1 Module complete all as specified and directed.
S&F modular type socket 5 Pin, 6 Amps, 240 Volt, 2 Module complete all as specified and directed.
S&F modular type socket 3-Pin combined , 6/16-Amps, 240 Volt, 2 Module complete all as specified and directed.
S&F modular type fan requlator, Step type, 240 Volt, 2 Module complete all as specified and directed.
S&F in replacement existing U/S light fitting with energy saving decorative LED batten 20 watt (4 Feet), 230 voltas, energy efficient tube light fitting extruded aluminium housing provided for efficient heat dissipation with polycarbonate diffusre & integrated electronic driver complete with all accessories prewired and includeing making connections with 3 core twisted flexible copper cable of size 23/.0076 from ceilling rose/PVC connector to light fittings complete all as specified and directed. Note:- Power factor should not be less thtn 0.95 Make- Havells Cat part No- LUMILINE+BS20WLED865SPCSS , ORIENT Cat part No-LBLN-20-C-AL /Phlips Cat part No- BN021C LED22S PSU CW GR
S&F in replacement of old U/S tube light fitting with energy saving decorative batten type 10 watt energy efficient tube light fitting (2 Feet) highly durable surface mounted LED batten constructed of fire retardent engineering grade extruded plastic and decorative end caps with all accessories prewired and making connection with 3 core copper flexible cable of size 23/.0076 from ceilling rose/PVC connector to light fittings complete all as specified and directed. Make- ORIENT Cat part No-LBLN-10-C-SQ/Phlips cat part- BN021LED12S6500PSUGR, Havells Cat part No- LUMILINE+ BS10WLED865SPCSS
S&F decorative wall mounting light fittings with opal glass diffuser and stainless steel body suitable for LED lamp 12 Watt (E-27 base) including one number 12 Watt LED lamp complete all specified and directed. Make: Phlips Model No 58184/Havells LHFOFAID1TZ1I040 or equivalent in Bajaj.
S&F in replacement recess mounted LED luminaire 36W 2'x2', 6500K, fully diffused, CCT, luminous efficacy of not less than 120 lm/watt designed for metric false ceiling type or alongwith frame suitable for Armstrong/ US Gypsum or similar mounting system with concealed or exposed 'T' sections, Glare free light alongwith electronic driver complete with all accessories prewired and connecting up with three core twister flexible copper conductor cable with suitable size complete removing unserviceable fittings all specified and directed. Make: Philips Cart Part No. RC380B LED36S-6500G5L60W60 PSU OD SG/ HavellsCat Part: PLUTONEO2X2PLR34WLED840S/ BAJAJ Cat ref - BZRSQL 43L LED GX PRO WH
S&F in replacement of Lithium based Energy Efficient integrated Solar street lights of 24 Watt in Single FRP Body with duly polylurethane coating (Camouflage color), encases with Monocrystalline solar PV Panel of 53/55Wp, lithium battery 11.1/12.8 V, 28.6 AH with inbuilt BMS, IP65, high brightness W-LED 160-180 lm/watt) lamp with Aluminium reflector for better light distribution, CRI>70, Colour Tempeture 5700K-6500K micro controller based charge controller curm driver automatic dimming function (first fou hours at full brightness & rest of the time at lower light level with PIR Motion sensor), dust to dawn operation, suitable to working temperature; -100C to +550C, weight more than 12-14 Kg with adjustable MS clap suitable for pole/wall mounting etc s complete all as specified and directed. Protection : Short circuit over load reverse plolarity and battery protections. firm should provide Vital parameters test report from NABL accredited lab and should be of made in India CE & ROHS compliant. Make - Axxon /Okaya power Pvt Ltd/Havells/Halonix
S&F in replacement of Lithium based Energy Efficient integrated Solar street lights of 18 Watt in Single FRP Body with duly polylurethane coating (Camouflage color), encases with Monocrystalline solar PV Panel of 53/55Wp, lithium battery 11.1/12.8 V, 28.6 AH with inbuilt BMS, IP65, high brightness W-LED 160-180 lm/watt) lamp with Aluminium reflector for better light distribution, CRI>70, Colour Tempeture 5700K-6500K micro controller based charge controller curm driver automatic dimming function (first fou hours at full brightness & rest of the time at lower light level with PIR Motion sensor), dust to dawn operation, suitable to working temperature; -100C to +550C, weight more than 12-14 Kg with adjustable MS clap suitable for pole/wall mounting etc s complete all as specified and directed. Protection : Short circuit over load reverse plolarity and battery protections. firm should provide Vital parameters test report from NABL accredited lab and should be of made in India CE & ROHS compliant. Make - Axxon /Okaya power Pvt Ltd/Havells/Halonix
Supply & Fix in replacement recess mounted LED luminaire 36W 1'x4', 6500K, fully diffused, CCT, luminous efficacy of not less than 100lm/watt designed for metric false ceiling type or alongwith frame suitable for Armstrong/ US Gypsum or similar mounting system with concealed or exposed 'T' sections, Glare free light alongwith electronic driver complete with all accessories prewired and connecting up with three core twister flexible copper conductor cable with suitable size complete removing unserviceable fittings all specified and directed. Make:- Phillips Cat Ref RC380B LED30S-6500 G5 L3W12 PSU OD/ Havells Cat Ref PLUTONEO4X1PLR30WLED840S/ BAJAJ Cat Ref BZRSLL 30L LED GX WH SD
S&F in replacement exisitng unsv Lamp with LED Lamp 9 watt, 6500 K, 230 volts B-22 Base complete all as specified and directed. Make: Havells/ Philips/ Bajaj
S&F in replacement 20 W LED tube with in built driver complete all as specified and directed Make :- Havells Cat part No-LHLDDCXCML8Q020 or equivalent in Philips/Bajaj/Orient
M&L for taking down carefully existing ceiling fan/exhaust fan for greasing / oiling of ball bearings / bushes and making it smooth and noise free operation and painting with one coat of Hi-Gloss synthetic enamel paint of approved shade by spray painting after filling cavaties and re-fixing after providing new fan clamp, nuts/bolts, washers and provision of 3 core copper flexible cable of size 1.0 Sqmm from ceiling rose to fan connector complete with writing of MES No. on the fan surface all as specified and directed.
Dismantling of existing meter panel board removing existing energy meter keeping safe custody and Design, Supply, installation, testing and commissioning of indoor type wall mounting size min (980X 650X245), Polycarbonate CPRI approved OEM made Meter Panel. The panel shall be made of modular POLYCARBONATE THERMOPLASTIC ENCLOSURES which should be UV resistance in accordance with IEC 61439-1, clause 10.2.4: The panel type wall mounted on mounting structure RAL 7016. The meter panel should be anti-acid & anti corrosive & fully transparent Door for meter vision. Degree of protection against mechanical load should be IK08 (5 Joule) in accordance with IEC 62262. The manufacturer of panel shall submit a copy of CPRI test report in polycarbonate only degree of ingress protection IP65 in accordance with IEC 60529. The gasket should be internally embedded made of polyurethane and enclosure make. The manufacturer of board/panel shall submit a copy of type test report of a board made out of Polycarbonate thermoplastic panel in accordance with IEC 60439-1.
The CPRI test report shall have mention of following tests performed and passed out satisfactorily: Temperature Rise, Dielectric Properties, Short circuit withstand current – Rated peak & short time withstand current and Rated Conditional Short Circuit Current, Effectiveness of Protective Circuits. The board manufacturer must submit the copy of type test reports for Polycarbonate Thermoplastic Board only. Test Reports submitted of other material of construction like MS, SS will not be applicable.. The panel should passed glow wire test 960oC in accordance with 60695-2-11 flame retardant and self-extinguishing complete all as directed with and incl the following (a) Provision for existing electric energy meter - 04 nos in separate chamber with locking arrangement. (a) Four pole MCCB 63 Amps with breaking capacity 16 KA having fixed thermal and fixed magnetic release and spreader link at both incoming and incoming side - 01 No. (b) MCB DP 32 Amp 10 KA , C Curve - 4 Nos (To be connected with 4 Nos Meters) (c) MCB DP 06 Amp 10 KA, C Curve - 1 No (For common lighting + Bldg Security Lights) (d) Ten Nos terminal blocks provided for output supply. (e) MCCB/MCB Nos Operated by flip Cover
(g) LED Indicating lamp - 03 Nos. (j) Internal wiring with 1100Volt grade 6.0 Sqmm FRLS PVC insulated multi flexible copper wire of sizes duly crimped with copper lugs of suitable size & type . Note : Re-fixed the energy meter in this new meter cabinet including all necessary electrical connection. Make :- Hansel / Schneider/ L&T/Siemens
Supply and fix in replacement of single phase 2 wire pre payment electricity meter 230 V , IP 54, Marked BIS-15884 /16444 Digital Energy Meter, current range 5-60 Amps, 240 Volts, accuracy class-1.0 optical port for local communications BLE for remote access, LED display, inbuilt load control switch including vending system through server, mapping of consumers complete all as specified and directed. Make :- Liberty 170 of Secure equivalent L&T/HPL Note:- Old Electric meter shall be deposited at E/M store yard.
Supply, instrallation testing & commissioning of 3 Phase, 4 Wire, LTCT operated 0.5s accuracy Prepaid Energy Meter along with set of 4 nos, 400A/5A LT CTs, BIS 16444 Marked in existing Meter Board / Floor Panels with Pre payment shock proof capacitive touch Keypad (Similar as IOS and android phone technology), Bluetooth, based Digital along with inbuilt load control switch, containing provision for TOD & RTC, inbuilt feature sense for data transfer (wireless, without DCU, USB, Pen drive) no other extra equipment required for data transfer, meter itself capable for data transfer) capable to define 4 tariff slabs, happy hour & hoilday definition , when user go outside of the home, user can punch recharge token on meter kaypad and manually and automatic via mobile app. Meter should support the following data's :- 30 minutes instantaneous data for voltage, current, power factor, power, cumulative energy and frequency, 30 load survey data for energy, monthly billing survey for Cumulative Energy and Max Demand. Meter should have connect / disconnect remotely remotely, functionality operable for prepaid/ post-paid billing software Make :-Secure/ L&T/ Havells Note:- Old Electric meter shall be deposited at E/M store yard.
S&F in replacement sheet metal enclosure MCB distribution board, double door with IP-43 protection single pole and neutral 240 volts, 8 way, including suitable size copper bus bar and neutral link, epoxy powder coated, factory made complete without MCB and with enclosure blank plates for unused way fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces complete all as specified and directed.
S&F in replacement sheet metal enclosure MCB distribution board, double door with IP-43 protection single pole and neutral 240 volts, 4 way, including suitable size copper bus bar and metal door, epoxy powder coated, factory made complete without MCB and with enclosure blank plates for unused way fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces complete all as specified and directed.
S&F in replacement sheet metal enclosure MCB distribution board, double door with IP-43 protection single pole and neutral 240 volts, 12 way, including suitable size copper bus bar and metal door, epoxy powder coated, factory made complete without MCB and with enclosure blank plates for unused way fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces complete all as specified and directed.
S&F in replacement sheet metal enclosure MCB distribution board, double door with IP-43 protection TPN 415 Volts, 6 way, including suitable size copper bus bar and metal door, epoxy powder coated, factory made complete without MCB and with enclosure blank plates for unused way fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces complete all as specified and directed.
S&F in replacement sheet metal enclosures distribution boards, double door three phase 415 volts 4 ways vertical TPN DB for comprising three phase four wire 200 Amp rated copper strip bus bar of appropriate capacity complete all as specified and directed and comprising of the following (a) MCCB four pole 100 Amps AC 415 Volts 25 KA - 01 No. as incoming (b) 12 Nos. MCB SP 40 Amps, C curve rupturing capacity 10 KA as outgoing Note :- (i) The DB shall be flush fixed and making good the disturbed surface matching with existing specifications. (ii) All connection of the MCCBs/ MCBs with cable shall be made through appropriate size pin /bottle type thimble -properly crimped. (iii) All vacant holes of the DB shall be provided with blank plates of appropriate size. (iv) Double continuous earth wire shall be provided for each three phase DB from earthing mains dolly (v) MCB's should have a same make as of DB.
S&F in replacement MCB single pole 240 volts, 'C' curve of rating from 6 to 32 amps, with rupturing capacity 10 KA, including providing thimble for out going cables complete all as specified and directed.
S&F in replacement MCB SPN 240 volts, 'C' curve of rating 6 to 32 amps, with rupturing capacity 10 KA, including providing thimble for out going cables complete all as specified and directed.
S&F in replacement MCB TPN 415 volts, 'C' curve of rating from 40 to 63 amps, 50 Hz with rupturing capacity 10 KA, including providing thimble for out going cables complete all as specified and directed.
M&L in replacement of existing unsv MCCB 63 Amps current carrying capacity 16 KA, AC 415 Volts four pole, 50 Hz with magnetic/ thermal fixed setting including providing thimble complete all as specified and directed.
M&L in replacement of existing unsv MCCB 100 Amps current carrying capacity 16 KA, AC 415 Volts four pole, 50 Hz with magnetic/ thermal fixed setting including providing thimble complete all as specified and directed.
S&F in repair sub main wiring with two single core PVC insulated (FRLS) unsheathed multistranded copper conductor of size 4 sqmm nominal cross sectional area and one run of 4 sqmm nominal cross sectional area PVC insulated (FRLS) unsheathed multistranded copper conductor green colour as continuous earth wire drawn in and including not less than 20 mm dia 'medium grade' PVC concealed conduits (ISI marked) and fittings including cutting chases to walls for laying conduit and making good the disturbed wall surfaces to match with existing specification complete all as specified and directed.
S&F in repair sub main wiring with two single core PVC insulated (FRLS) unsheathed multistranded copper conductor of size 6 sqmm nominal cross sectional area and one run of 6 sqmm nominal cross sectional area PVC insulated (FRLS) unsheathed multistranded copper conductor green colour as continuous earth wire drawn in and including not less than 20 mm dia 'medium grade' PVC concealed conduits (ISI marked) and fittings including cutting chases to walls for laying conduit and making good the disturbed wall surfaces to match with existing specification complete all as specified and directed.
S&F in replacement sheet metal enclosures, single pole with socket, plug top and one single pole MCB 20 Amps, 240 V complete all as specified and directed.
M&L for earthing complete with galvanised steel plate electrode 600mm x 600mm x 6mm thick buried directly in ground (earth pit not less than 2.25 Mts deep below ground level with top edge of the plate not less than 1.50 Mtrs below ground level connected to glavanised iron Wire 4.0 mm dia by means of bolts, nuts check nuts and washers of galvanised iron or steel connected to earthing test point all as specified incl 15 mm GI tubing medium grade and necessary fitting for protection of GI wire incl laying of charcoal dust and common salt in alternate layer, PCC Pit (1:3:6) type C-1 using 20 mm graded stone aggregate, RCC cover 40mm thick (1:2:4) type B-0 using 12.5 mm graded stone aggregate reinforced with 6 mm dia round bar @ 75 mm C/C both ways with MS handle 8 mm dia, plastering 15 mm thick CM (1:6) externally upto 150mm below ground level , GI funnel with 20mm dia medium grade GI pipe for watering and wire mesh incl excavation and earth work and disposal of surplus soil complete all as specified and shown on electrical plate No 3 of SSR Part (2009) and connected to earth test point incl testing and marking Bldg Nos and writing Test Results on a 3.0 mm thick painted M.S. earth pit marking Plate (200mm x 100mm) duly welded with a 450 mm long 10 mm dia round M.S. rod, fixed with the earth pit chamber by grouting complete including taking out old unserviceable earthing system including demolishing old earth pit chambers and removing of debris from the site with levelling the ground all as specified an directed.
M/s Pooran Singh and Company
Balaji Associates
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .