Superintending Engineer, PWD
O/o. Superintending Engineer, PWD, Buildings Maintenance Circle, Chepauk, Chennai-5.
Sub Work Repair and renovation of Administrative Building with Rewiring and Renewal of Fittings, Fans, Computer plugs and Power mains in 1st floor of Madras Veterinary College Vepery Chennai 07
2023_PWD_400226_1
PWD/16/BMC/2023-2024
Open Tender
Electrical and Maintenance Works
Lump-sum
60 days
Vepery
refer tender documents
8 documents required · 8 mandatory
₹0
₹15,000
6 Mar 2024
19 Dec 2023
29 Dec 2023
19 Dec 2023
29 Dec 2023
19 Dec 2023
Amount
Re-Wiring with 2 x1.5 sq.mm. (22/0.3) PVC insulated single core unsheathed copper conductor of 1100 V grade in suitable PVC rigid pipe on wall and ceiling with PVC accessories with Module Plastic surface mounting switch box on wall with 6A one way module switch with module front plate with painting of Suitable colour for Open PVC Light point / fan point (for electronic regulator) ( 4 points / Coil)
Re-Wiring with 2 x 1.5 Sqmm. (22/0.3) PVC insulated SC unsheathed cu. Conductor with of 1100V grade in suitable PVC rigid pipe on wall and ceiling with PVC accessories with 6A Modular switch with surface box and covered with modular plates with suitable colour for open PVC light point (Anchor roma/equ) (5 points per coil)
Re-Wiring with 2 x1.5 sq.mm. (22/0.3) PVC insulated single core unsheathed copper conductor of 1100 V grade in suitable PVC rigid pipe on wall and ceiling with PVC accessories with Module Plastic surface mounting switch box on wall with 6A one way module switch with module front plate with painting of Suitable colour for Open PVC Light point / fan point (for electronic regulator) ( 6 points / Coil)
Renewal by supply and Run of 2 of 2.5 sq.mm. (36/0.3) PVC insulated SC unsheathed copper conductor of 1100 V grade in suitable PVC rigid pipe on wall and ceiling with continuous earth wire connection by 2.5 sq.mm. PVC insulated SC unsheathed copper wire with painting of suitable colour.
Renewal by supply and Run of 2 of 4 sq.mm. (56/0.3) PVC insulated SC unsheathed copper conductor of 1100 V grade in suitable PVC rigid pipe on wall and ceiling with continuous earth wire connection by 2.5 sq.mm. PVC insulated SC unsheathed copper wire with painting of suitable colour.
Renewal by supply and Run of 4 of 10 sq.mm. (140/0.3) PVC insulated SC unsheathed copper conductor of 1100 V grade in suitable PVC rigd pipe on wall and ceiling with continuous earth wire connection by 4 sq.mm. PVC insulated SC unsheathed copper wire with painting of suitable colour.
Renewal by supply and fixing of cable management box (50 x 50 mm) with cover and allied accessories viz divider, cover joint, end cap bottom and top joint part suspended from ceiling with threaded rod with anchor fasteners and with bolt and nut.
Renewal by supply and fixing of 20W, 4 feet LED fitting on wall or ceiling with PVC unsheathed copper leads from terminals to the fitting
Labour Charges for Removing and Re-fixing of Exisiting 20W, 4 feet LED fitting on wall or ceiling with PVC unsheathed copper leads from terminals to the fitting
Renewal by supply and fixing of 20W, 4 feet LED fitting with conduit pipe suspension from the wall or ceiling with PVC unsheathed copper leads from terminals to the fitting
Renewal by supply and fixing of 24W LED 2x2 square type Recessed fitting with LED (Higher end) on false Ceiling with suitable hanging support from ceiling with PVC unsheathed copper leads from terminals to the fitting.
Labour Charges for Removing and Re-fixing of Exisiting 24W LED 2x2 square type Recessed fitting with LED (Higher end) on false Ceiling with suitable hanging support from ceiling with PVC unsheathed copper leads from terminals to the fitting.
Renewal by supply and fixing of 18W LED Round type Recessed fitting with LED (Higher end) on false Ceiling from ceiling with PVC unsheathed copper leads from terminals to the fitting.
Labour Charges for Removing and Re-fixing of Exisiting 18W LED Round type Recessed fitting with LED (Higher end) on false Ceiling from ceiling with PVC unsheathed copper leads from terminals to the fitting.
Renewal by supply and fixing of 1200mm (48") sweep AC ceiling fan complete ( Higher end) with 2 module 100W fan step regulator (Higher end) with 300mm down rod with fan clamp
Renewal by supply and fixing of 18" A/C Wall Mount Fan, HSN Code - 84145910, Make - ALMONARD / Equivalent along with PVC unsheathed Copper leads from terminals
Renewal by supplysupply and fixing of 300mm (12") sweep (heavy duty) AC exhaust fan complete with necessary wall opening and making good of the wall
Renewal by supply and fixing of BH with 10W LED lamp with PVC unsheathed copper leads from terminals to the fitting
Renewal by supply and fixing of 3nos.6A two module 5 pin socket , 3 nos. 6A one module switch with module cover plate (plastic) on suitable module concealed Box (GI ) in flush with wall with connections.
Renewal by supply and fixing of 1 no.6A two module 5 pin socket , 1 no. 6A one module switch with module cover plate (plastic) on suitable module concealed Box (GI ) in flush with wall with connections. Higher End.
Renewal by supply and fixing of 2nos.6/16A two module socket , 2 nos. 16A one module switch with module cover plate (plastic) on suitable module concealed Box (GI ) in flush with wall with connections.
Renewal by supply and Fixing of 20A DP plug and Socket in sheet steel enclosure with 32A DP MCB in flush with wall with earth connection (For AC Plug)
Renewal by supply and Fixing of 9W LED Mirror Light (Make Philips Astra line /Equivalent)On wall with necessary Connections.
Renewal by supply and fixing of AC/DC Call bell suitable for 230 volts 50 C/s Single phase AC supply on suitable Box with modualr switch.
Renewal supply and fixing of 4 way Vertical Triple pole and neutral MCB sheet steel enclosure distribution board with double door (metal) with 1 no. 63A 4P MCB switch as incoming and 12 nos. 6A to 32A SP MCB as outgoing in flush with wall with earth connection only. The MCB DB and MCB’s should be with ISI mark. (Hager / legrand / Equivalent Make)
Renewal by supply and fixing of 8 way single pole and neutral MCB sheet steel enclosure distribution board with double door (metal) with 1 no. 32A DP MCB switch as incoming and 6 nos. 6A to 32A SP MCB as outgoing in flushwith wall with earth connection only. Higher End
Renewal by supply and fixing of 12 way single pole and neutral MCB sheet steel enclosure distribution board with double door (metal) with 1 no. 32A DP MCB switch as incoming and 10 nos. 6A to 32A SP MCB as outgoing in flush with wall with earth connection only. The MCB DB and MCB’s should be with ISI mark. (Hager/ Legrand/ Equivalent make)
Renewal by supply and clamping of 3-1/2 x 25 sq.mm. PVC LTUG armoured LTUG cable on post or on wall with MS Clamps
Renewal by supply and fixing of brass cable gland for 3-1/2 x 25 sq.mm. PVC armoured LTUG cable with earth connection
Renewal by supply and providing cable end termination of 3-1/2 x 25 sq.mm. PVC LTUG aluminium armoured cable with necessary aluminium cable sockets by crimping etc with electrical connection complete
Renewal by supply and clamping of 3-1/2 x 70 sq.mm. PVC LTUG armoured LTUG cable on post or on wall with MS Clamps
Renewal by supply and fixing of brass cable gland for 3-1/2 x 70 sq.mm. PVC armoured LTUG cable with earth connection
Renewal by supply and providing cable end termination of 3-1/2 x 70 sq.mm. PVC LTUG aluminium armoured cable with necessary aluminium cable sockets by crimping etc with electrical connection complete
Renewal by supply, erection, testing and commissioning of 5"x5"x2" 125A floor/Wall mounted MV cubical panel board suitable for operation on 415 V3 phase, 50 Hz A.C supply,dust and vermin proof and accommodating the following Switches as Incomer unit with the following items of work complete to satisfy the latest IE rules and CEIG guidelines with Bus bar chambers, Main switches chambers and cable entry chambers. Bus bar chambers: supply and fixing of suitable bus bar chamber made up of 16SWG MS sheet steel ( 1.8mm) with 4Nos. 1” x ¼ tinned copper Main bus bar for 3 phases and neutral ,1”x 1/8” for 63 Amps Interconnection copper bus bars and 2Nos of earth bus size 1” x 1/8” tinned copper bus bar on suitable bus bar insulator ( Epoxy insulator) with colour coding of phases and neural indication. maximum creepage distance and supported on MS Base channel frame work of size 4” x 2” x1/4” - 1 Set Main Switches Chamber: Incoming 1) supply and fixing of 1No. 125A 4pole 433 V LT MCCB confirming to IS13947-2 IEC 60947- with suitable capacity and breaking capacity of 70KA breaking capacity with all
V Suresh
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_477479.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .