Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.3 LAccepted-AOC | L1 | Accepted-AOC Being lowest bidder | |
| 2 | L2₹29.0 L+₹7.1 L (32.3%)Rejected-Finance BOOTH NO 56 MAIN MARKET SECTOR 40 C CHANDIGARH U T 160036 | CHANDIGARH | CHANDIGARH | CHANDIGARH | 160036 | L2 | Rejected-Finance Being not lowest tender | |
| 3 | L3₹30.0 L+₹8.1 L (36.9%)Rejected-Finance 303 GHS 888 SECTOR 20 PANCHKULA 134116 HARYANA | PANCHKULA | PANCHKULA | HARYANA | 134116 | L3 | Rejected-Finance Being not lowest tender | |
| 4 | L4₹33.9 L+₹12.0 L (54.6%)Rejected-Finance 901 GH 83 SECTOR 20 PANCHKULA 134116 | PANCHKULA | HARYANA | 134116 | L4 | Rejected-Finance Being not lowest tender |
Tender Value
₹32 L
EMD Value
₹64,000
Closing Date
16 Nov 2019, 6:00 pmClosed
GE
GE AF MC CHANDIGARH
REPAIR/MAINT TO VARIOUS SIZES OF UNSERVICEABLE PUMP SETS, MOTOR AND STARTER PANELS AT 3BRD AF STN CHANDIGARH
2019_MES_287490_3
GE(AF) MC CHD-36/2019-20
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
CHANDIGARH
Please refer Tender documents.
10 documents required · 10 mandatory
₹500
Yes
GE AF MC CHANDIGARH
₹64,000
Yes
CHANDIGARH
31 Jan 2020
5 Nov 2019
18 Nov 2019
5 Nov 2019
16 Nov 2019
7 Nov 2019
6 Nov 2019 - 7 Nov 2019
7 Nov 2019
Amount
M & L for opening and servicing of BPI pump of capacity 7.5 HP of dismantling of existing platform/location by disconnecting electric and fuel connection of pump set , decoupling pump & motor transportation to civil work shop motor & pump opening the body of motor, oiling greacing of motor & pump set ,replacement of bearing, cleaning of stator, cleaning the slot, of both bearing as size ,opening of fuel pump ,servicing of reparing of pump compete ,replacement of mechanical seals of pumps, replacement of bearing, overhaling of pump proper alignment of pump including all necessary nut, bolts ,welding works and rubber coupling L-110 & L-90 if required for setting of pump & motor complete all as directed and specified Engineer in charge.
Material and Labour opening of BPI self priming fuel pump from BPI pump house foundtion after disconnecting from fuel line and closing the line with dummy plate with nut bolts and dismantling the same for assesing and carring out the repairs at civil work shop replacemet of u/s parts (i.e, silica seal, gasket, bushes, nut bolts, gear oil) servicing of pump complete and making good in serviceable condition, reassembling the same on the foundation and testing complete all as directed by Engr-in-charge.
All as per item No 7.00 but centrifugal pump capacity 15 HP
All asper item no 7.00 but monoblock pump capacity up to 5 HP
All as per item no 5.00 but capacity 45 HP.
Taking out defective sewage submercible motor & pump sets of 12.5 HP/9.37 KW from Sewage well by disconnecting electricaly and water connection, decoupling pump & motor by the help of chain pully block & transportation to work shop, opening the body of motor, taking out burnt/defective winding wire carefully without damaging the stator, cleaning the slot, rewinding the stator with super enamelled copper winding wire of existing gauge alongwith the following parts as under and reconnected the motor from same location by help of chain pully block and making all connection of motor and testing on load complete all as specified and as directed . Mechanical seal upper- 01 No, Mechanical seal Lower- 01 no, Impeller lock nut-01 no, Impeller lock nut washer -01 no, Neck ring gun metal - 01 no, O ring-1 nos.
M&L for taking out pump set 45 to 65 HP along with column pipe flanged 100/150 mm bore with submersible cable from bore hole of tube well of any depth using crane and sufficient man power, plugging / covering of open well by means of dummy plate, dismantling joints of flanged pipes in position including removing old rubber board gaskets , bolts , nuts , washers, gasket for 150 mm dia flange and any spare parts required for smooth functioning of bore well after repair complete including lowering of submersible pump set 45 to 65 HP complete set capacity by means of cranes, connecting, testing complete all as directed by Engineer in charge.
M&L for transportation of submersible pump & motor 65 HP to local work shop for repair and replacing of unserviceable burnt parts / burnt copper winding like winding wire 2.3 mm, motor housing bush, thrust bearing pad , S S Shaft (per stage), slot straighter & filling , seal bush GM, GM neck ring, SS sleeve, Suction Chamber, blasing works ,bowl bush, stain less key, nut bolt and washers, Gasket ,two coat paints and any spare parts required any type of polishinh any type of grinding for smooth functioning of pump and back to site after repair , connecting, testing complete all as directed by Engineer -in- charge at site . Note- Any type of grinding, polishing, brazing, ball, motor bush pump repair studs nut,bolts, gasket, any accessories, submersible motor cable up to 3 mtr lead 02 nos replaced if required to be replaced works are included in quoted rates not any type of extra payment given to contractor all as directed by EIC at site and workshop.
All as per item no 11.00 hereinbefore but size 25 sqmm 3 core.
M & L for opening and servicing of Monoblock pump of capacity 7.5 HP to 10 HP of dismentling of existing platform/location by disconnecting electric and water connection of pump set , decoupling pump & motor transportation to civil work shop motor & pump opening the body of motor, oiling greacing of motor & pump set ,replacement of bearing, cleaning of stator, cleaning the slot, of both bearing as size ,opening of fuel pump ,servicing of reparing of pump compete ,replacement of mechanical seals of pumps, replacement of bearing, overhaling of pump proper alignment of pump including all necessary nut, bolts ,welding works and rubber coupling if required for setting of pump & motor complete all as directed and specified Engineer in charge.
M&L for earthing complete with galvanized steel earth plate electrode 600 mm x 600 mm x 6 mm thick buried directly in ground vertically in a pit of depth not less than 2.25 metre below ground levels with top edge of the earth plate not less than 1.50 metre below normal ground level surrounded from all sides by mixture of charcoaland common salt and electrode connected to and including galvanized iron earth strip, 32 x 6 mm by means of bolts, nuts check nuts and washers of galvanised steel including GI pipe light grade 40mm dia for protection pipe and GI pipe medium grade 20mm dia bore for watering funnel with wire mesh. 80mm thick precast RCC 1:1.5:3 type A1 cover with frame duly reinforced with XPM (weight not less than 3kg/sqm), PCC chamber pit with PCC 1:3:6 type C-2 excavation and earth work all as shown in electrical plate No 3 connected to earthing test point complete all as specified and directed by Engineer-in-Charge. Note : The unit rate includes for protecton pipe 40mm and GI earth strip 32 x 6mm from top of earth plate upto 7.50 metre above ground level.
Taking out damaged /unservicable submersible 3 core 35 sq mm cable, Supply, laying and testing PVC insulated & PVC sheathed industrial 3 core 35 sq mm flat submersible cable with bare bunched copper conductor for submersible pump & motor with voltage grade 1100 volts generally conforming IS :694. complete incoming and out going connection including 35 sqmm copper lugs all as directed by Engr in charge. Make: Plaza/havells/Finolex.
All as per item no 13.0 but size 10 sqmm 3 core.
All as per item no 13.0 but size 6 sqmm 4 core.
Taking out damaged /unservicable PVC unarmoured 3 core 16 sqmm cable ,Supplying, laying and testing PVC insulated & PVC sheathed industrial 3 core 16 sqmm unarmoured copper cable with bare bunched copper conductor for sewage pump & motor with voltage grade 1100 volts generally conforming IS : 7098 Part 1 - 1988 with up to date amendments complete incoming and out going connection including 16 sqmm copper lugs all as directed by Engr in charge. Make: Plaza/havells/Finolex.
All as per item no 13.0 but size 4 sqmm 4 core.
Taking out brunt copper lugs from panel and supply and fixing copper lugs of size 35 Sq mm to 25 Sq mm, refreshing of cable if required replaced the suitable size of copper lugs and connecting properly including disconnecting power supply from existing switch gears complete all as specified and directed by the Engr -in -charge at site.
All as per item no 17.0 but size 10 to 16 sqmm.
Taking out unservicable DOL Starter of any capacity Supply, installation, testing and commissioning of DOL straters in sheet metal steel enclosure single phase starter type MK-I, 6-10 Amps, 220 Volts completeall as directed by EIC. Make:- L&T/BCH/C&S
All as per item no 19.0 but capacity 3 phase, 415 Volts, Relay rating 18-25 Amp, 25/18HP/KW.
Taking out unservicable Reverse starter any capacity & Supply, installation, testing and commissioning of 3 Phase, 415 Volts, 20/15HP/KW, Relay rating 23-32 Amps including steel metal enclouser grounting in wall making all in coming & out going connections and testing all as directed by EIC. Make:- C&S/BCH/L&T
Taking out u/s Ammeter from diffrent location supply and fix Ammeter square flush mounted digital LED type of range 0-200 Amps complete all as specified and directed by the Engr -in -charge.Make:- C&S/L&T/AE
Taking out u/s Volt meter from diffrent location supply and fix Voltmeter square flush mounted Digital LED type of range 0- 500 Volts, complete all as specified and directed by the Engr -in -charge. Make:- C&S/L&T/AE.
Supply installation, testing and commissioning of pressure gauge of range pressure capacity 0 - 300 kg/cm2 capacity up to 10 kg/sq cm pressure ISI marked including dismantling existing one complete all as specified and directed by Engineer-in-Charge .MAKE -BAUMER/WARRIES/H-GURU.
Desilting/ cleaning of sewage storage well of depth 10.00 Mtr and 4.85 Mtr dia taking out sludge in the form of solid manually and getting out and removal to a distance n. exc 500 mtr and burried the same in low laying area as directed by Engineer-in-Charge
Dismantling and taking down solar water heater system after disconnecting electric and water supply connection and Opening of 200 ltrs cap solar water heating system made up of 2 Nos 100 ltrs capacity solar collector and opening and separating each collector of 100 ltrs cap from the existing frame by unscrewing the flange joint , dismantling and taking out top cover made out of toughened glass from the top of the solar collector for cleaning the inner copper tube with the help of electric driven mono block pump set by using descaling chemical solution and giving adequate pressure of water till the deposited silt is thrown out from the tubes and drying out with the help of blower and finally removing the dust particles with the help of vacuum cleaner including replacement of unserviceable nut bolts, dead flanges, gasket etc and refitting the same in original pattern and testing complete all as specified and as directed by Engineer-in-Charge .
Disconnecting and taking out the old unserviceable heating element of capacity 3 KW with thermostat from the hot water tank by opening the outer frame of the tank, draining out the hot water and replacement of heating element of capacity 3 KW with thermostat complete all as specified and as directed by Engineer-in-Charge
Dismantling the hot water tank 400/500 ltrs from the unit and taking out the inner tank for de-scaling and necessary welding for checking leakages including providing fresh lagging and outer aluminum sheet cover of original gauge and sill complete all as specified and directed
Dismantling the hot water tank 200 ltrs from the unit and taking out the inner tank for de-scaling and necessary welding for checking leakages including providing fresh lagging and outer aluminum sheet cover of original gauge and sill complete all as specified and directed
Taking down unserviceable flat plate collector based on indirect transfer of heat and M & L for replacement of flat plate collector based on indirect transfer of heat suitable for 100 LPD capacity solar water heater ISI MARKED complete all as specified and directed by Engr-in-Charge. Make- Tata BP solar india/Technologies Pvt Lt or equivalent.
Taking down unserviceable flat plate collector based on indirect transfer of heat and M & L for replacement of flat plate collector based on indirect transfer of heat suitable for 200 LPD capacity solar water heater ISI MARKED complete all as specified and directed by Engr-in-Charge.Make- Tata BP solar india/Technologies Pvt Ltd or equivalent. .
Taking down unserviceable submain wiring and Supply and fixing submain wiring for phase and neutral with 2 x 6 sqmm and 1 x 4 sqmm earth wire in PVC conduit ISI MARKED complete all as specified and directed by Engr-in-Charge .Make Havell/finolex/polycab or equivalent
Taking up or down steel tubing 20 mm bore of solar water heater and connections including cleaning for re-fixing with connected items complete all as specified and directed by the Engr-in-Charge.
Supply and fixing hot water pipe duly insulated with glass wool and aluminum cladding 20 mm bore ISI MARKED complete all as specified and directed by Engr-in-Charge.Make-Tata/jindal/kalinga or equivalent
S & F GI tubes medium grade 20 mm bore of solar water heater with all fittings and fixed complete to walls and ceiling or laid in floors ISI MARKED complete all as specified and directed by Engr-in-Charge. Make-Tata/jindal/kalinga.
M & L for Gun metal globe or gate valves of solar water heater with iron wheel head , screwed both ends for iron pipes for 20 mm bore pipe confirming to IS 778 class 1 cu-alloy screwed in bonnet inside screw non rising stem cu alloy body complete all as specified and as directed by Engr-in-Charge.Make-Bir/sant/jolota/leader or equivalent-
M&L for Bib tap cast copper alloy chromium plated fancy type of bore 15 mm (in repair) confirming to IS 778 class 1 cu-alloy complete all as specified and as directed by Engineer-in-Charge. Make-Bir/sant/jolota/leader or equivalent- .
Replacement of unserviceable solar collector glass made out of toughened glass ISI MARKED as per original pattern and size of capacity 500/200 ltrs complete all as specified Make- Tata BP solar india/Technologies Pvt Lt or equivalent.
Replacement of unserviceable temperature gauge on hot water tank as per original pattern and size (in repair) complete all as specified Make- Tata BP solar india/Technologies Pvt Lt or equivalent.
M & L for replacement of rubber hose pipe (in repair) of 25 mm bore, 300 mm long ISI MARKED complete all as specified and directed by Engr-in-Charge Make- Tata BP solar india/Technologies Pvt Lt or equivalent.
Taking down unserviceable geyser of capacity 25 / 50 Ltrs from site and opening for repair of leakage transporting for welding at local welding shop and checking for any other problem and refixing back complete all as specified and directed by Engr-in-Charge .
M & L for replacement of Heating element of 2 KW (in repair) ISI MARKED complete all as specified and directed by Engr-in-Charge Make- Leader or equivalent.
M & L for replacement of Heating element of 1.5 KW (in repair) ISI MARKED complete all as specified and directed by Engr-in-Charge. Make- Leader or equivalent.
M & L for replacement of thermostate for 25/50 ltrs geyser (in repair) ISI MARKED complete all as specified and directed by Engr-in-Charge Make- Leader or equivalent.
M & L for replacement of indicating lamp for 25/50 ltrs geyser (in repair)ISI MARKED complete all as specified and directed by Engr-in-Charge Make-Secure meters , GE, simens or equivalent
Disconnecting and taking out the old unserviceable PVC Hot water pipe from existing geyser, supply and fixing flexi connection Hot water pipe 15 mm dia up to 2 Meter length complete all as specified and as directed by Engineer-in-Charge
Disconnecting and taking out the old unserviceable PVC Hot water pipe from existing geyser, supply and fixing flexi connection Hot water pipe 15 mm dia up to 1 Meter length complete all as specified and as directed by Engineer-in-Charge
Disconnecting and taking out the old unserviceable safty valve of existing geyser of any capacity ,supply and fixing safty vlave of geyser of capacity 25 to 50 ltrs complete all as specified and as directed by Engineer-in-Charge
Disconnecting and taking out the old unserviceable damaged tank of 25 Ltr Geyser and supply and fixing os SS tank of 25 ltr geyse of all as specified and as directed by Engineer-in-Charge
Disconnecting and taking out the old unserviceable damaged tank of 50 Ltr Geyser and supply and fixing os SS tank of 50 ltr geyse of all as specified and as directed by Engineer-in-Charge
Taking out U/S preventer supply, fixing and testing 3 Phase 4 Wire, over votage/under voltage preventor supply, fixing and tesing on load 3 Phase & nuetral voltage & over voltage onitoring device AC control of 415 volts suitable 3 Phase 4 Wire, frequency range 45-55 HZ suitable size copper cable and connection with new copper lugs, nut bolts including taking out old unserviceable 3 phase preventor from existing LT panel of pump house, complete all as specified and directed by the Engr -in -charge. Make:- BCH/ LEGRAND/ SCHNIDER/L&T (GIC)
S&F new power contactor 3 pole ML- 2 of L& T with DC coil of AC-3 rating 60 Amps suitable for motor including connection with suitable size copper cable and removing unsv cable and connection with new coper lugs, nut bolts including taking out old unserviceable contactor form existing LT panel of pump house complete all as specified and directed by the Engr -in -charge. Make :- Equivalent to BCH/Siemens/Schieneider
All as per Item no 52 but capacity 3 pole ML 4 of L& T.
All as per Item no 52 but capacity 3 pole ML 6 of L& T.
All as per Item no 52 but capacity 3 pole MNX 50 of L& T.
All as per Item no 52 but capacity 3 pole MNX 70 of L& T.
All as per Item no 52 but capacity 3 pole MNX 80 of L& T.
All as per Item no 52 but capacity 3 pole MNX 95 of L& T.
All as per Item no 52 but capacity 3 pole MNX 140 of L& T.
All as per Item no 52 but capacity 3 pole ML 1.5 of L& T.
Takingh out u/s Add on block supply and fix Front mounting Add on block aux contact block 415 volts 2NO+2NC type suitable for 60 to 62 Hp pump motor including connection with suitable size copper cable and connection with new copper lugs, nut bolts including taking out old unserviceable contactor relays from existing LT panel of pump house complete all as specified and directed by the Engr -in -charge
All as per item no 61 herein before but 415 volts1NO+1NC.
Taking out u/s CI stainer supplyand replaced of cast iron Y-type stainer,screwed/bolted cover ,flanged type used in water supply/compressed line of size 100mm dia, body SS screen, including all fixing arrangement of stainer all as directed at site by the Engr-in-Charge. Make :- Sant/Leader/Zoloto/Bir
All as per item No 63.0 herein before but size 80 mm dia.
Taking down u/s foot valves supply and fixing Gun metal foot valve of 100 mm dia including all necessary fitting arangement all as directed by Eng -in -Charge. Make:- Sant/Leader/Zoloto/Bir
All as per Item No 65 herein before but Size 80 mm Dia.
Taking out u/s MCCB, S&F of MCCB 200 Amps, 4 pole with breaking capacity 25 KA, 415 volts from existing LT panel complete all as specified and directed by Engr-in-Charge. Make- Indoasian/L&T/ HAVELLS/CG/HPL/SCHNEIDER
All as per item No 67 But size 200 Amps 4 Pole.
All as per item No 67 but size 160 Amps 4 Pole.
All as per item No 67 but size 100 Amps 4 Pole.
Taking out old unserviceable plug top and socket, supply and fixing, and testing complete 15 amps plug & socket all as specified and directed by the Engr -in -charge.Make - Anchor/C&S /Havells.
To attending day to day complaints of any nature of solar water heater ,Geysers ,motorised hanger door ,water supply section LT Panels with connected accessories like MCCB,s starter ,relays ,single phase preventor ,lugs ,copper cables, meggering of cable, checking of pump / motor at any pump house /sub station , MCBs, Contactors, relays, , pvc cable, lugs, ferruls, loose nut bolts etc at any location and locating the fault and rectification on working days except sunday and holiday from 0800hrs to 1600 hrs by employing technician for day to day complaints,rectify faults as and when occured ,replacement of small spares lugs,screw,wire etc is included in quoited rates as require complete all as specified and directed by Engr in Charge.
Cleaning/washing the pump set (pump & motor) of capacity 1 to 3 HP scrubing the old peep out paint with emery paper/wire brushes, preparing the surface, painting the same with one coat of synthetic enamel spray paint of approved colour/tint complete all as directed at site by EIC.
Supply in replacement MS nut bolts(hard fastner) of suitable sizes for both glands, flanges on both ends and top canopy,for fixing of gyser and sollar pannel also as require at site of sutable sizes complete all as directed by Engineer-in-Charge.
Taking out u/s GUNMETAL valve ,Supply, installation, testing and commissioning/welding any addition alteration for fixing of wall of gun metal gate valve pressure class rating CLASS-2 gun metal body ,screwed in bonnet outside screw , conforming to IS-778 heavy duty for operation on 10 kg/ cm2 pressure complete with jointing material like rubber sheet nut and bolts including dismantling existing gate valve complete all as specified and directed by Engineer-in-Charge of the following sizes
(a) 40 mm dia
(b) 25 mm dia
(c) 20 mm dia
(d) 15 mm dia
Taking out ETH cooling tower from site servicing of existing cooling tower such asextenction of hight of leg up 2mtr from ground lenel with welding mechine welding the damaged part of colling tower , replacement of complete fins,replacement of fiber sheet cpmplete bottom part of colling tower ,the fiber sheet will be fixed by screwing nut bolt of suitable size ,suitable size of strip welding with help of welding mnachine to extra support for fiber ,cleaning of complete inside and out side portion of the cooling tower with cleaning chemical properly ,spray painting with two coat of paint in side & out side after scraping old/pild paint , electricaly disconnected of electric motor overhauling and servicing of cooling tower motor,stripping out and coupling ,bearing ,taking out armature, cleaning slots ,replacement of bearing /bushes of suitable size ,painting of motor ,reassembling the complete motor into position testing on full load and welding works for coling tower for cutting & fixing of cooling tower works requirede at site is the responcibility of contractor all as directed by EIC at site.
Taking down unserviceable MS pipe 150 mm dia bore M&L for stainless steel welded pipes flanged type grade (ASTM specification: SA312 TP 304) of thickness 3 mm to 3.25 mm with stainless steel fittings(i.e, elbow, bends, reducer stainless Nut & bolts & connector) of same grade as per stainless steel pipe non reactive with ATF, water & WATER RUST /CORROSION PROOF,duly TIG (argon) welding and fixed with gasket suitable for ATF K-50 compatible rubberised gasket/sealant non reactive for ATF line of 150 mm at site all the flanged joints shall be brought at same potential by interconnecting pipes/ fittings on either side of the flanged joint with a filling point lid of the respective BPI tank complete all as directed by Engineer in charge. Make - Om India Stainess steel Tube/Jundal/TATA
All as per item No 77.00 here in before but size 63.50 mm dia.
All as per item No 77.00 here in before but size 100 mm dia.
Taking down unserviceable MS Gate valve 100 mm dia bore Supply and fixing stainless steel gate valve of grade TP 304, 100 mm nominal dia flanged type suitable for fuel line, Pressure rating 150, complete all necessary welding works ,nut bolt & packing material all as reqired at site and testing of line. Make- Universal/BIR/ZOLOTO
All as per item No 80.00 here in before but size 63.5 mm dia.
Taking down old unserviceable MH/Sodiuom vapour light fittings 150/250 watts from pump/sewage/over head tanks supply and fixing of energy saving LED street light fittings, 45W capacity, high pressure die cast aluminium housing with seal toughened glass cover light source should be multi LED SMD array with individual secondary lenses, colour temperature 6000K ± 500K, SYSTEM Efficiency should be minium 100 Lumens/watt and minium system lumen package of 4500 lumens as LM9 complete all as directed. Make- CG/Havells/Philips
Supply and fix in replacement of MCB SPN 32 Amp complete all as specified and as directed. Make: ABB/Siemens/Havells
M&L in replacement PVC insulated weather proof and sheathed flat twin core cable with aluminium conductor cable of size 10.00 sqmm drawn through conduit pipe/bracket and making connection to the fittings complete all as directed and speciifed by EIC.
M & L for servicing the Air compressor Make - Atlas Copco (Model - GA 55 VSDFFA) and Taking out the unseviceable / repairable parts from the compressor with due care, and supply / fixing of the following new and original spare parts including carrying out all related minor and periodical maintenance and ovehauling works as and when required all as directed and specified by Engineer in Charge.
Air Filter (1613800400)
Safety Cartridge (2914931100)
Oil filter spare 8000 Hrs (2903752600)
Oil separator Kit (3002600140)
Clean System (9095143000)
Oil Can 20 Litre (2901170100)
L-7 Primewave Communications
R D Bansal
HARISH SALES CORPORATION
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .