GE (Central) Pune
Garrison Engineer (Central) Pune Arjun Marg Pune 411001
8230 SPECIAL REPAIR TO BLDG NO T-35 AT 13 FD SUB GP UNDER GE (CENTRAL) PUNE
2021_MES_447807_1
8230 SPECIAL REPAIR TO BLDG NO T-35 AT 13 FD SUB G
Open Tender
Civil Works
Item Rate
150 days
GE (Central) Pune
As per tender documents
9 documents required · 9 mandatory
₹500
GE (Central) Pune
₹49,000
Yes
22 Jul 2021
2 Jun 2021
25 Jun 2021
2 Jun 2021
23 Jun 2021
16 Jun 2021
Amount
Demolition of Cement concrete (unreinforced) in ground floor or paving n.exc 15 cm thickness (below or above ground level) and removing rubbish off the premises complete all as directed
Dismantling of plain or corrugated, steel sheeting, any gauge, thickness and removing off the premises complete all as directed.
Dismantling wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, including cover fillets and removing u/s materials off the premieses complete all as directed
Dismantling of structural steel work including doors,gates but excluding framed Truss etc complete inlcuding removing off the premises complete all as directed.
Excavating in trenches, n.exc 1.5m wide and n.exc 1.5m in depth for fdn, etc or for shafts, wells, cesspits, manholes, pierholes etc and n.exc 10 sqm on plan and n.exc 1.5m in depth and getting out in hard / dense soil complete all as specified and directed.
Returning filling in including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and directed.
Removing excavated soil n.exc 50m and depositing where directed at a level n.exc 1.5 m above the starting point complete all as specified and directed.
M&L for plain cement concrete type D2 1:4:8 (using 40mm graded aggregates) in foundation, filling and mass concrete complete all as specified and directed.
M&L for precast cement concrete block masonry exceeding 10cm in width with solid blocks of PCC (1:5:8) grade C-5 and setting in CM 1:6 complete all as specified and directed.
S&F MS structural steel work, framed as in trusses, purlins, rafter, post etc. conforming to grade E-250 (Fe-410W, quality A) including shaped washers including necessary cutting required length, notching drilling, riveting and or welding or connecting with nut bolts with angle cleats, fish plat, gusset plate and also erecting in true position complete as specified and directed.
S&F prepainted galvalume aluminium zinc coating GI based corrugated steel sheet 0.5 mm thick profie bent to curve as required at site and directed of any colour as approved by GE having tensible strengh 500 MPA as in roof covering/clouding to wall fixed with self tapping screws complete all as specified and directed.
M&L for 25 mm thick PCC (1:2:4) type B0 using x12.5 mm graded stone aggreate as levelling course in floor complete all as specified and directed.
M&L Non skid ceramic colored tiles 7to8mm thick, (square/ rectangular) area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm in floor etc.set and jointed in neat cement slurry & pointed in white or coloured cement to match over and above including 15mm thick screed bed or bedding layer in CM 1:6 complete all as specified and directed.
All as per item No 14 here-in-before but area of each tile exe 0.18 sqm but n 0.38 sqm.
M&L for 15mm thick rendering in CM 1:6 over brick / conc wall surfaces and sagol finished for internal wall surfaces complete all as specified and directed.
M&L for preparation of newly plastered surface of all and applying two coats of oil bound distemper over a coat of primer of same make over 2 mm thick wall care putty, to obtain the true line to achieve smooth surface complete all as specified and directed
M&L for preparation of new steel surfaces exc 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
Taking down existing unserviceable point wiring of any description/type/ size of light/fan/tube/power/two way/bell etc on TW batten/conduit including removal of batten / conduit / gutties / wooden boards / switches / sockets / regulators/ light fittings etc and removal of unserviceable material out of site and making good the disturbed surfaces of wall/ceiling so as to match with the existing finishes all as specified.
Taking down the existing unserviceable main switch / cut out / DBs of any type / capacity / description as existing at site including MCBs any type and capacity making good the disturbed surfaces to match with the existing finishes all as specified.
Taking down the existing unserviceable sub main wiring of any type / description as existing at site including making good the disturbed surfaces to match with the existing finishes all as specified.
Taking down ceiling fan/ exhaust fan of any sweep, keeping with safe custody and refixing the same with replacement of unsv 3 core PVC insulated PVC sheated 3 core multistranded copper conductor cable of size 23/ 0.193 from ceiling rose to fan terminal over hauling the fan and Painting of ceiling fans complete, in situ with synthetic enamel paint by spraying including filling cavities with filler, after cleaning all dust etc complete all as specified and as directed..
M&L for point wiring of any length using approved colour coding as per IS, with stranded copper conductor 1.5 Sq.mm (Nominal area), single core, PVC insulated and unsheathed stranded FRLS cable 1100 volts grade, ISI - 694 marked, in PVC conduits 20 mm dia or above, ISI marked including all accessories etc. with Modular PVC boxes, frame, cover suitable for mounting switches/sockets etc. and PVC insulated stranded copper conductor 1.5 Sq.mm single core cable as earth and connecting to common earth dolly complete all as specified for the following:- (Note:- Making good of disturbed surfaces will be done by contractor without any extra claims.)
(a) One light point controlled by one, one way switch
(b) One ceiling fan/ exhaust fan point controlled by one, one way switch and regulator.
(c) One 3 pin socket outlet,5 Amps on same board with other switches, cables 1.5 sqmm size
(d) One 3 pin socket outlet,5 Amps on independent board with cables, 1.5 sqmm size
All as per Item No. 23 above but with stranded copper conductor 2.5 Sq. mm (nominal area), single core, PVC insulated and unsheathed multistranded FRLS cable 1100 Volt grade ISI-694 marked for 3 pin, 15 Amp socket outlet, independent board, including PVC insulated multistranded FRLS copper conductor 2.5 Sqmm (nominal area) single core as earth continuity conductor to common earth and connecting to earth dolly.
S & F modular switch 6A SP one - way 230V white ivory finish complete all as specified
S & F modular switch 16A SP one - way 230V white ivory finish complete all as specified
S & F modular socket outlet 2/3 pin 6 amps, multipurpose 2 module 230 Volts, single pole one way suitable for plug tops, complete all as specified.
S & F modular socket outlet 2/3 pin 16 amps, multipurpose 2 module 230 Volts, single pole one way suitable for plug tops, complete all as specified.
S & F stepped type modular fan regulator electronic type for ceiling fan two module with white ivory finish complete all as specified.
S & F for celling rose 2/3 terminals, PVC/ polycarbonate, isolated body ISI marked complete all as specified.
S&F MCB TPN DB 4 way double door with 200 amps rated busbar, MCB TPN as incomer and MCB DP/SP as outgoer, fixed on wall and making good to disturbed surfaces, and connecting with existing cable complete all as specified and directed.
S & F for MCB DB, SPN, sheet metal enclosure, 8 way with 200 amps rated bus bar double door, fixed on wall good to disturbed surfaces, and connecting with existing cable complete all as specified and directed.
S & F for MCB four pole of rated capacity 63 amps, 415 volts breaking capacity 10 KA, C-curve complete all as specified and directed.
S & F for MCB double pole of rated capacity 32 amps, 240 volts breaking capacity 10 KA, C-curve complete all as specified and as directed.
S & F for MCB Single pole rated capacity 6 to 32 amps, 240 V breaking capacity 10 KA ,C- curve complete all as specified and as directed.
Supply and fix LED Tube light fittings wall mounted, 18 W LED 6500K with Opal white Poly Carbonate diffuser provided with high efficient integral constant current LED Driver 230 V etc. complete with mounting batten including all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size from ceiling rose to connector Conforming to Cat Part No. BLRB DB 118 & BLRB18 W CW LED Make :- Bajaj or Equivalant in model Philips/ Havells/Wipro
Supply and fix LED energy efficient security light 30 Watt Luminaire in pressure die cast housing along with prismatic polycarbonate diffuser and LEDs with secondary optics and IP 65 Protection including MS angle GI pipe of 40 mm dia of suitable length as per site requirement with nut bolts and allied accessories for mounting complete all as specified. Make - Bajaj Cat Part No. BCLST 30W LED I or equivalent in other approved makes.
M & L for Submain wiring with 2 runs of single core 4 sqmm PVC insulated unsheated multistranded 1100 volts grade with copper conductor drawn through and including non-metalic PVC, ISI marked and its accessories in Conduit in wall/ roof/floor including one run of single core 4 sqmm PVC insulated unsheated multistranded 1100 volts grade with copper conductor cable as earth continuty conductor along with the wiring and connected from DB to DB/ main board complete all as specified and as directed. Note: 3 runs of 4 sqm cable and 1 of PVC conduit shal be measured as one unit.
M & L for Earthing complete with galvanised steel earth plate electrode 60cm x 60 cm x 6 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0 mm as earth lead wire by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in Electrical plate No 3, SSR Part I- 2009 with 15 mm dia medium grade GI pipe as a protection and 20 mm dia medium grade GI pipe for watering purpose inlcuding funnel, wire mesh, RCC pit with cover complete and connected to earthing test point all as specified or indicated including testing on completion.
Parhar Enterprise
M/s Akshay Contruction
Suma Construction
SHAH BUILDERS
ganesh electricals and airconditioners
L.T Associate
M/s Asrani and sons
TRINITY ENGINEERS
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .