Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.0 LAccepted-AOC | L1 | Accepted-AOC lowest | |
| 2 | L2₹18.0 L+₹2.0 L (12.3%)Rejected-Finance RCP GURUDWARA ROAD WARD NO 29 SURATGARH SRI GANGANAGAR 335804 | SURATGARH | SRI GANGANAGAR | RAJASTHAN | 335804 | L2 | Rejected-Finance not being lowest |
Tender Value
Refer Docs
EMD Value
₹30,000
Closing Date
18 Oct 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
LT COL PRIYESH SRIVASTAVA
GE (AF) SURATGARH
PROVN OF STANDBY POWER SUPPLY FOR HQ COMPLEX OF 2209 SQN AND CERTAIN MINOR WORKS AT AF STATION SURATGARH
2022_MES_553224_1
8995/E8
Open Tender
Civil Works
Item Rate
180 days
GE (AF) SURATGARH
AS PER TENDER DOCUMENTS
10 documents required · 10 mandatory
₹500
GE (AF) SURATGARH
₹30,000
20 Dec 2022
20 Sept 2022
20 Oct 2022
20 Sept 2022
18 Oct 2022
4 Oct 2022
Amount
BOQ (PROVN OF STANDBY POWER SUPPLY FOR HQ COMPLEX OF 2209 SQN AND CERTAIN MINOR WORKS AT AF STATION SURATGARH)
Supply, install, testing and commissioning of silent Diesel Engine Generating set factory assembled , floor mounted 415 volts, 3 phase, 4 wire engine as per IS : 10001/10002 and alternator as per IS : 13364 of capacity 35 KVA at site complete with relay panel for automatic starting on mains failure, control panel having meters, sound proof canopy etc including neccessary Foundation & plinth work of DG set all accessories as per manufactures standard and as per the details given below :- AC Generator should be suitable for ambient conditions at Suratgarh and confirming to IS. Make of Engine : - CUMMINS/Cropmtion Greaves/Ashok Leyland/ Kirloskar Green/Mahindra. Make of Alternator -:Jyoti/Stamford/Cromption Greaves/ Kirloskar Green/Mahindra. Note : The capacity of generater set shall be net after all derating factor as per relavent IS design.
(a) Alternator : Synchronous alternator for continuous opeartion at 1500 RPM generating 415 volt at 0.8 PF suitable for 50 hz ,three phase 4 wire system .The alternator shall be brushless,single bearing ,self excited & self regulated with an AVR .The alternator will be suiatble for tropiacal climate and shall generally conform to IS : 4722. The salient faetures of the alternators are :-(i) +- 1% voltage regulation (max) in static conditions. (ii) IP 23 protection with H insulation (iii) Permanent lubricating bearing (iv) Permissible overload 10 % for one hour in 12 hours of operation. (b) Diesel Engine : Having adequate capacity for 35 KVA alternator, BHP not less than capacity for 35 KVA alternator, water cooled to drive alternator with cold starting with an over load capacity of 10 % for one hour in any 12 hours continuous running complete with all standard accessories all as specfied. 12 V ,180AH battery starting system or as recommended by manufacturer, Maintanance free battery with initial charging , residential type exhaust silencer complete with exhaust pipe, hour meter, water temp gauge, oil pressure gauge, Fuel tank with capacity for full load non-stop 8 hrs running.
(c) Sound proof Canopy : All as per stipulated in CPCB norms & the Govt of India. (d) AMF Panel : Supply, install, testing and commissioning of AMF Panel outdoor type, cubical body, dust and vermin proof made up of CRCA sheet 3 mm thick painted with two coats of synthetic enamelled paint over a coat of red oxide primer confirming to IP 45 with front and rear opening with louvers and mounted on floor with PCC pedastal pillars with a clearence of atleast 0.3 m above ground level with glands sockets etc with provision of cable entry from bottom all pre wired and connected complete with following accessories:- (i) PLC - 01 No (ii) Power Contactor heavy duty suitable for generator and mains (iii) Over load relay for Genset (iv) Suitable rating isolating switch MCCB for both DG & main supply. (v) Multi functioning meter to indicate voltage, current, frequency, P F, KW & KWH etc (vi) Emergency stop push button.
Specification: Air intake system (i) Air intake manifold (ii) Dry type air cleaner (iii) Vacuum Indicator Exhaust System (i) Expansion below (ii) Exhaust manifold Cooling system (For Air cooled ) (i) Blower fan in built engine (ii) Exhaust fan For Water cooled (i) Engine water pump (ii) Coolant (iii) Radiator with pusher type fan Lubricating System (i) Lube Oil cooler (ii) Lube oil Filter "Spin -on" type Fuel System (i) Filter "Spin -on" type (ii) 12 V DC solenoid coil (iii) Inline fuel injection pump and fuel feed pump Starting System (i) 12 Volt starter (ii) 12 volt DC solenoid coil (iii) 12 Volt DC Battery charging Alternator Instrument Panel : (i) Start/Stop Push Buttom (ii) Lube oil pressure indication (iii) water temperature indication (iv) RPM indication (v) Engine running hour indication (vi) Low lube oil trip indication (vii) High Engine temperature trip indication (viii) Battery Charging Indication (ix) Over /under Speed trip indication (x) Low Fuel level indication (xi) Over load trip Indication Safety Controls : (i) Low lube oil pressure trip (ii) High Engine temp trip (iii) Low fuel level trip (iv) Overload trip (v) Over /under speed trip
DG set shall be inspected in factory premises before dispatch by representative of the Accepting officer.
Note:- (i) The engine of DG set shall be suitably designed to give output of 35 KVA including 10% overload. (ii) The quoted rate for DG set shall be inclusive of PCC foundation .The foundation for DG set shall be made of PCC as per OEM recommendations . The size of platform shall be as per manfacturers recommendations complete all as specified and directed. (iii) THE DHPP (fuel ) required for testing of DG set shall be arranged by the contractor and the cost of the same shall deemed to be included in the unit rate quoted for DG set . (iv) Phase -1 test shall be carried out by ENGINEER -IN -CHARGE for no load for 1 hour and phase - II test shall be carried out in presence of IEM /EI for a period not less than 12 hours continuously out of which at least half an hour each on NO load and 25% load ,two hours on 50% load and four on 75% load, four hours on rated full load and one hour on 10% excess of rated full load. (v) DG set shall be comosite type with control panel , primer mover ,alternator and allied accesories in one enclosure.
Supply laying and testing cable XLPE insulated screended PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 95 sqmm 3.5 core all as specified and as directed.
Supply laying and testing cable XLPE insulated screended PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 35 sqmm 3.5core all as specified and as directed.
M&L earthing complete with GI earth plate electrode 600mmx600mmx6mm thick buried in ground vertically to a depth not less than 2.25 mtrs below ground level with top edge of earth plate not less than 1.5 mtrs below ground level connected with GI earth strip 32mmx6mm thick and GI bolts, nuts, etc and protected by GI pipe light grade 40mm bore and 20 mm dia GI tubing light grade with funnel for watering, connection to main control board/earth dolly all as shown in electrical plate No.3 of SSR Part I incl necessary earth work and excavation in any type of soil, PCC earth chamber with RCC cover slab, salt, charcoal and MS hook complete all as specified and as directed.
Supply,installing testing and commissioning LT cubicle panel CPRI approved feeder pillar box outdoor type platform mounted,suitable for accomodating all MCCBs with input volatge 415 3 phase 4 wire ,50 hz AC supply system complete all as specified and directed having aluminium bus bar installed on DMC/Epoxy insulator. The panel shall be dust and vermin proof,IP65 class protection and made of 3.15mm thick CRCA MS sheet with front and rear opening type with double door shutter and locking arrangement (incl provn of lock with 2 key ) powder coated finish over a coat of red oxide ,primer on outside and two coats of red oxide primer on inside surface. The panel is installed over a platfoam of suitable size withPCC 1:3:6 type C-2 using 40 mm crushed stone aggregate 20 cm thick in foundation and height upto 0.5 m all as directed at site.All interconnection between the main bus bar as well as outgoing feeders shall be carried out with TPN aluminium bus bar of rating 1.5 times the incoming main MCCB and should be insulated with shrinkable PVC sleeves. The MCCB should be adjustable type. The scope of work includes provision of following. Note: All MCCBs should have adustable thermal and magnetic settings. INCOMING (a)MCCB, 4 pole,125 Amps 36KA Adjustable thermal setting 80-100% - 01 No OUTGOING (b) MCCB, 4 pole,100 Amps 25KA - 01 No (c) MCCB, 4 pole, 63 Amps 25 KA - 02 No (d) Onload changover switch 125 amp -01 No (e) Digital type Amp meter 0 to 500 Amps with adequate size CTs - 01 (f) Digital type volt meter 0 to 500 volts - 01 No(g) Indicating lamp LED type for 3 phase electric system - 01 Set(h) Spare MCCB space -01 NoNote : Cable glands and lugs of suitable size shall be provided for each cable. MAKE of MCCB/MCB/Contactor /Changover switch -L&T/Schneider /Havells
Excavation in trenches not exc 1.5m depth and not exc 1.5m wide in for foundation of poles/laying of cable/stay/strut not exceeding 10 sq m on plan and getting out in soft/loose soil complete all as specified and directed.
Returning & filling in including spreading, leveling and well raming in layers not exc 25cm thick at a level complete all as specified and directed.
M & L for removing excavated material n.exc. 50m and depositing where directed at a level n.exc. 1.5 m above the starting point complete all as specified and directed.
M& L for Sand cushioning to cables with a layer of sand 8 cm deep before laying the cable and 15 cm depth after laying of cable, complete all as specified. NOTE : Punned down thickness shall be measured.
M&L un-reinforced precast concrete cable cover class LV ,type I flat ,size 250 mmx 150 mm x 40 mm all as specified and directed.
M&L for 50mm bore galvanised steel tubing light grade (ISI marked) protection of cable fixed to pole /walls or laid in floors ,road crossing ducts with all necessary fitting and fixed with clamps ,bolt,nuts and washer etc complete all as specified and as directed.
Supply and laying testing cable XLPE insulated screended PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 70 sqmm 3.5 corecomplete all as specified and as directed.
Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC)complete all as specified and as directed.
M&L for point wiring with 2.5 sqmm (nominal area) in stove enameled steel conduit insulated PVC single core unsheathed multistandred copper conductor cable in FRLS and including fittings and accessories with continuous stove enameled steel conduit 20 mm dia medium grade ISI marked insulated copper cable with copper conductor of same size as in phase/netural/earth cable connecting to common earth dolly including (enameled steel conduit/wooden box of suitable size with laminated sheet cover of 3mm thick mounting swiches, socket,regulator), complete all as specified and directed by Engr-in-Charge.
One light point controlled by one switch 16 A.
M&L for point wiring with 4.0 sqmm (nominal area) in stove enameled steel conduit insulated PVC single core unsheathed multistandred copper conductor cable in FRLS and including fittings and accessories with continues stove enamelled steel conduit 25 mm dia medium grade ISI marked insulated copper cable with copper conductor of same size as in phase/netural/earth cable connecting to common earth dolly including (enameled steel conduit/wooden box of suitable size with laminated sheet cover of 3mm thick mounting swiches, socket,regulator), complete all as specified and directed by Engr-in-Charge.
One light point controlled by one switch 16 A independent.
S&F for flame proof rotary type switch with termination box in LM-6 capacity 16 Amp 250 Volts 50 Hz, complete all as specified and directed by Engr-in-Charge.
S&F for flame proof -weather proof switch socket & plug 16 Amp 250 Volts (2P+EARTH), complete all as specified and directed by Engr-in-Charge.
S&F for LED light fitting 2x16 watt flame proof, CMRI certified recommended for gas/vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum housing with heat resistant toughened glass with LED tube light fixtures driver, holders connector etc. Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size, complete all as specified and directed by Engr-in-Charge.
S&F for Sub main wiring (concealed ) with two single core 6 sq mm (nominal area) FRLS PVC insulated unsheathed stranded copper conductor cable drawn through including chasing cutting in any type of masonary including 25 mm dia non-metallic PVC conduit fixed in wall including 4 sq mm copper earth continuity wire, accessories and connecting to earth dolly, complete all as specified and directed by Engineer-in-Charge. Note :- 2 run of 6 Sqmm, 1 run of PVC conduit & 1 run of 4.0 Sqmm cable shall be measured as single unit length.
Supply and fix FLP/WP switch /isolator 16 Amp double pole on/off complete all as specified and directed.
Supply and fix FLP/WP switch /isolator 10 Amp single pole on/off complete all as specified and directed.
Supply and fixing flame proof weather proof MCB DB SPN 12 way double door IP 42 CRCA sheet powder coated factory made suitable for incorporating MCB as outgoing connecting incoming and outgoing cables and blanking plate as required complete all as specified and as directed.
Supply and fixing flame proof weather proof MCB DB TPN 4 way double door IP 42 CRCA sheet powder coated factory made suitable for incorporating MCB as outgoing connecting incoming and outgoing cables and blanking plate as required complete all as specified and as directed.
Supply laying and testing cable XLPE insulated screended PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 16 sqmm 4 core complete all as specified and as directed.
M&L for brick protection cover of UG cable by old size bricks common burnt clay bbuilding bricks sub class "B" laid dry and flat abutting each other with widthequal to length of brick and gap between adjacent brick not exceeding 10mm complete all as specified and directed.
M&L Earthing complete with G I earth plate electrode 600 mm x 600 mm x 6 mm burried directly in ground vertically in pit of depth not less than 2.25 metre below normal ground level with top edge of the earth plate at a depth not less than 1.5 metre below normal ground level surrounded from all sides with mixture of charcoal and common salt in alternate layers and electrode connected to G I earth strip 4 dia G I wire by means of brass bolts, nuts, check nuts and washers, earth strip protected by galvanized steel pipe 40 mm bore (light grade) connected to main switch board or any other electrical equipment all as shown in electrical plate No. 3 of SSR-2009 Part I and including necessary excavation and earth work in any type of soil, 20 mm bore medium grade GI pipe for watering, funnel with wire mesh, PCC (1:3:6), type C-1 chamber, pit cover of precast RCC (1:2:4), type B-1, reinforced XPM of weight not less than 4 kg/ Sq.m and MS frame etc. including replacment of old unserviceable earthing, complete all as specified and as directed by Engineer-in-Charge. Note :- (i) The unit rate includes earth lead and protection pipe up to maximum 7.5 metre from earth plate to earth point/test point. (ii) Earth pit shall be constructed minimum 0.5 metre away from earth.
Supply and fixing flame poof weather proof MCB DB SPN 4 way double door IP 42 CRCA sheet powder coated factory made suitable for incorporating MCB as outgoing connecting incoming and outgoing cables and blanking plate as required complete all as specified and as directed.
Excavation in post hole (or similar holes) each n exc 0.5 cum, getting out, returning filling in and ramming earth or broken rubble mixed with earth around in layers not exceeding 25cm, thick watering, and removing surplus soil to a distance n.exc 50m and making good surface in soft/loose soill, complete all as specified and directed.
M&L for cement concrete 1:3:6 type C1 (Using 20mm graded stone agrregate ) as in foundation of posts, railing and similar work complete all as specified and directed by Engr-in-Charge
S & F Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161-1979 grade St.-240 complete all as specified and directed by Engr-in-Charge.
S& F rolled mild steel work as in Compound girders and stanchions, lattice girders, aerial masts, staging for water tanks and the like including caps, bases, splices etc. built up from two or more beam or channel sections or angles with plates, including all lattice bars,stiffeners, gusset plates, etc.FE-410-W (GDE E-250 ) quality -A complete all as specified and directed by Engr-in-Charge.
M&L for two coats of synthetic enamel painting to steel and steel based surfaces of any description, not otherwise described over 10cm width or girth over one coat of red oxide primer including preparation of new surfaces, complete all as specified and directed.
S&F pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws, complete all as specified and directed.
S&F mild steel work confirming to Fe 290 grade E-165 flat iron as in wind tie for roof including necessary drilling for securing bolts etc, complete all as specified and directed.
S&F aluminum anodised coloured powder coated door shutter single/double leaf side hung type without sash bars including jointing cleats aluminium anodised snap beading ,screws ,aluminium anodised fittings such as pair of D type handlee (decorative type) tower bolts 150 mm long 2 Nos for each shutter 100 mm size butt hinges aluminium beading PVC packing locking arrangement with mortice lock of best quality complete all as specified and directed.
S&F Anodised aluminium coloured powder coated frame for doors,windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified and directed.
S&F 5.5 mm thick Sheet glass,ordinary quality and glazing with oil putty in aluminum door ,partition in square exc 0.5 sq. m in each pane complete all as specified and directed.
S&F Door closer hydraulically regulated, designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg complete all as specified and directed.
S&F Door seal of polyfibre /EPDM fixed at bottom rail of the door complete all as specified and directed.
Supply and fixing sound proof / sound reduction PVB laminated glass that is made by sandwiching a laminated sheet between two pieces of tempered and digo glass and the mained sheet is polyvinyl (PVB ) sheet glass should be (6 mm glass + 12 to 24 mm argon gap + 1.6 mm glass ) fixed with powder coated aluminium window using 95.6 mm X 44.8 MM X 1.6 MM chowkhats with 63 mm X 38 mm X 1.6 mm etc with necessary fixing arrangement on wall including taking down existing window with complete all as specified and as directed.
Contract Amount shall be in General Summary on serial page No 17 of tender documents.
SRI SAI CONSTRUCTION COMPANY
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .