| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹94,193.91Accepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹99,026.66+₹4,832.75 (5.13%)Rejected-Finance | L2 | Rejected-Finance Stood L2 | |
| 3 | L3₹1.2 L+₹22,000.63 (23.4%)Rejected-Finance | L3 | Rejected-Finance Stood L3 | |
| 4 | Rejected-Technical | - | Rejected-Technical SCC PART 10 OF ELECTRICAL SUPERVISOR LICENSE NOT FOUND |
| Sl No | Description | Qty | Unit | ADHISHARM INDUSTRIALS L1 | M/S GRACIOUS ENGINEERING PROJECT L3 | SADHAN ELECTRICAL ENTERPRISE L2 |
|---|---|---|---|---|---|---|
| 1.00 | Distribution wiring in 1.1 KV single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit 'FR' (Precision make) with saddles incl. necy. fittings as required.
2 x 56/0.3 (4 sqmm) + 1 x 36/0.3 (2.5 sqmm) ECC | 39 | mtr | 153 ₹5,967 Lowest | 200 ₹7,800 | 155 ₹6,045 |
| 2.00 | Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes.2.5 sqmm | 3 | Set | 6 ₹18 Lowest | 6 ₹18 Lowest | 6 ₹18 Lowest |
| 3.00 | 4 sqmm | 6 | Set | 7 ₹42 Lowest | 7 ₹42 Lowest | 7 ₹42 Lowest |
| 4.00 | Supply & Fixing 240 V, 20 A plug socket (Brand approved by EIC), without plug top and switch in sheet metal switch board with bakelite/perspex top cover by screws after making housing for plug socket by cutting bakelite/perspex top cover and making necy. connections with PVC wire and earth continuity wire etc. | 1 | No. | 75 ₹75 Lowest | 125 ₹125 | 75 ₹75 Lowest |
| 5.00 | Supply & Fixing 240 V, 25 A, Modular type starter with 25A Modular switch type DP MCB (C Curve) and S&F 4 Module GI Modular type switch board flushed in wall incl. necy. connection as per GS.(Make: North west /Crabtree / Brand approved by EIC). | 1 | No. | 800 ₹800 Lowest | 1,500 ₹1,500 | 1,200 ₹1,200 |
| 6.00 | Supply & Fixing 240 V,25 A, 3 pin Modular type plug top with indicator & necy. connections.(Make: North west/ Anchor/ Crabtree) | 1 | No. | 130 ₹130 Lowest | 130 ₹130 Lowest | 130 ₹130 Lowest |
| 7.00 | Supply & Delivery of 2 Ton/2.2 Ton SPLIT type air conditioner having the following specification:-
(a)Star rating -3 star Non inverter type
(b) Rated voltage -230v+/-5% frequency-50Hz
(c) Compressor type -Rotary
(d)Cordless Remote arrangement with all modernize Provision of temerature setting, Fan speed option (low/midium/high), Auto Swing, Air direction Setting ,Timer facility ,Turbo operation setting , Air ventilation arrangement and others.
(e) Refigerant must be R410 A / R32 (make- Mitsubishi Heavy/ O-General/Mithsubishi Electric) and PCB Board must be placed inside suitable size of Metal enclosure as per direction of EIC. | 1 | No. | 62,280 ₹62,280 Lowest | 75,000 ₹75,000 | 65,000 ₹65,000 |
| 8.00 | Installation of 2 Ton / 2.2 Ton Split Type Room AC Mchines (both indoor & outdoor unit) by Co's own tools, tackles & manpower including Supply & Installation of MS Angle Iron Frame / Bracket made of 40 x 40 x 5 mm thick should be grouted / bolted on wall by cement morter for fixing 1.5 TR Split AC Machine.all complete as per direction of EIC. | 1 | No. | 2,200 ₹2,200 Lowest | 2,550 ₹2,550 | 2,500 ₹2,500 |
| 9.00 | Supply & Fixing 5/8" Cu pipe with Nitrile Rubber Insulation for Suction Line of Split AC Machine after Bending, Swerazing, Welding as required. This is with Al wrapper as required. (Extra after 3 Mtr.) | 6 | RM | 338 ₹2,028 Lowest | 650 ₹3,900 | 400 ₹2,400 |
| 10.00 | Supply & Fixing 1/4" Cu pipe with Nitrile Rubber Insulation for Liquid Line of Split AC Machine after Bending, Swerazing, Welding as required. This is with Al wrapper as required. (Extra after 3 Mtr.) | 6 | RM | 150 ₹900 Lowest | 150 ₹900 Lowest | 150 ₹900 Lowest |
Tender Value
Refer Docs
EMD Value
₹1,881
Closing Date
19 Mar 2025, 2:00 pmClosed
AE/AESD-II PWD
Office of the Assistant Engineer P.W.D. Asansol Electrical Sub- Division II Near Polo Ground Dist-Paschim Bardhaman
SITC of 1 one no A.C. machine at EVM warehouse, Kanyapur in the dist. of Paschim Bardhaman.
2025_WBPWD_824853_1
WBPWD/AE/AESD-II /eNIQ-16(2nd call)/2024-25
Open Tender
ELECTRICAL WORKS ORG
Item Rate
ASANSOL
Please refer Tender documents.
4 documents required · 4 mandatory
₹1,881
8 Sept 2026
7 Mar 2025
21 Mar 2025
7 Mar 2025
19 Mar 2025
12 Mar 2025
Amount
Distribution wiring in 1.1 KV single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit 'FR' (Precision make) with saddles incl. necy. fittings as required. 2 x 56/0.3 (4 sqmm) + 1 x 36/0.3 (2.5 sqmm) ECC
Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes.2.5 sqmm
Supply & Fixing 240 V, 20 A plug socket (Brand approved by EIC), without plug top and switch in sheet metal switch board with bakelite/perspex top cover by screws after making housing for plug socket by cutting bakelite/perspex top cover and making necy. connections with PVC wire and earth continuity wire etc.
Supply & Fixing 240 V, 25 A, Modular type starter with 25A Modular switch type DP MCB (C Curve) and S&F 4 Module GI Modular type switch board flushed in wall incl. necy. connection as per GS.(Make: North west /Crabtree / Brand approved by EIC).
Supply & Fixing 240 V,25 A, 3 pin Modular type plug top with indicator & necy. connections.(Make: North west/ Anchor/ Crabtree)
Supply & Delivery of 2 Ton/2.2 Ton SPLIT type air conditioner having the following specification:- (a)Star rating -3 star Non inverter type (b) Rated voltage -230v+/-5% frequency-50Hz (c) Compressor type -Rotary (d)Cordless Remote arrangement with all modernize Provision of temerature setting, Fan speed option (low/midium/high), Auto Swing, Air direction Setting ,Timer facility ,Turbo operation setting , Air ventilation arrangement and others. (e) Refigerant must be R410 A / R32 (make- Mitsubishi Heavy/ O-General/Mithsubishi Electric) and PCB Board must be placed inside suitable size of Metal enclosure as per direction of EIC.
Installation of 2 Ton / 2.2 Ton Split Type Room AC Mchines (both indoor & outdoor unit) by Co's own tools, tackles & manpower including Supply & Installation of MS Angle Iron Frame / Bracket made of 40 x 40 x 5 mm thick should be grouted / bolted on wall by cement morter for fixing 1.5 TR Split AC Machine.all complete as per direction of EIC.
Supply & Fixing 5/8" Cu pipe with Nitrile Rubber Insulation for Suction Line of Split AC Machine after Bending, Swerazing, Welding as required. This is with Al wrapper as required. (Extra after 3 Mtr.)
Supply & Fixing 1/4" Cu pipe with Nitrile Rubber Insulation for Liquid Line of Split AC Machine after Bending, Swerazing, Welding as required. This is with Al wrapper as required. (Extra after 3 Mtr.)
Supply & Fixing 3/4" PVC HEAVY DUTY drain water pipe line for Split AC Machine.
Supply & Fixing 4 core 2.5 sq. mm. round PVC unarmoured copper cable (Mk. Havell's / KEI / Polycab)
Supply & Fixing 3 core 4 sq. mm. round PVC unarmoured copper cable (Mk. Havell's / KEI / Polycab)
Supplying and fixing of 240V 32Amp SP MCB of Breakong capacity of 10KA & C characteristics on Din rail of existing DB and necessary connection(Make:Legrand/L&T/ Crabtree)
Supplying and fixing of 240V 63 Amp DP MCB Isolator on Din rail of existing DB and necessary connection(Make:Legrand/L&T/ Crabtree)
Add GST @18% On total from item no 1 to 13
Add LWC @1% On total from item no 1to 14
SADHAN ELECTRICAL ENTERPRISE (BID ID -6236021)
M/S GRACIOUS ENGINEERING PROJECT (BID ID -6244012)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .