| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.3 CrAccepted-AOC | ₹6.3 Cr Quoted ₹6.6 Cr | L1 | Accepted-AOC Awarded |
| 2 | L2₹7.3 Cr+₹73.8 L (11.2%)Rejected-AOC HOUSE NO 3000 SECTOR 15 HOUSING BOARD COLONY SONIPAT 131001 | SONIPAT | SONIPAT | HARYANA | 131001 | ₹7.3 Cr+₹73.8 L (11.2%) | L2 | Rejected-AOC Rejected |
Tender Value
₹6.3 Cr
EMD Value
₹12.6 L
Closing Date
6 Jul 2023, 3:00 pmClosed
AMIT KUMAR SANDILA
EE PHE Division No. 3 Palwal
Supplementary estimate for providing sewerage system in village khambi, Tehsil Hodal and District Palwal (under Mahagram Yojna) Supplementary estimate for providing sewerage system in village khambi, Tehsil Hodal and District Palwal (under Mahagram
2023_HRY_292601_1
20230AE30F70 920D 4AFA 92C6 FD87C70091EF561PUH
Open Tender
Civil Works
Works
240 days
KHAMBI KHAMBI KHAMBI
Refer to Tender Documents
3 documents required · 3 mandatory
₹20,000
₹12.6 L
Yes
11 Sept 2023
22 Jun 2023
6 Jul 2023
22 Jun 2023
6 Jul 2023
22 Jun 2023
Amount
Provision for restoration of water connection damaged due to laying of sewerage network complete in all respect
Provision for HT metriing Panel with GO switch, H Pole VCB / ACB and all other required electrical items AT M.P.S.
Provision for making foundation for machinery complete in all respect AT M.P.S.
Provision for pipe / Valve / Specials for Pumping machinery
Provision for construction of MS truss bridge of 1 mtr. wide on distributory for laying and crossing of 200 mm i/d DI K-9 rising main from IPS/1 to manhole N/1 through pumping complete in all respect.
Construction of HT/LT Panel room, PLC room, Centrifue house, blower room and Lab cum office building including doors, windows and fitting etc. at STP site covered area with RCC framed structure of brick work vitrified glazed tiles flooring, powder coated aluminium frame of size 100mm × 45mm of 10 guage for chowkhat, 75mm × 45mm of 10 guage for door frame, 45mm × 45mm of 10 guage for window frame with 5mm thick glass AIS/Saint Gobin/Modi Float.
Providing and installation of 6 No. CCTV cameras (2 at MPS and 4 at STP ) including cost of Wiring DVR, cable, lens etc. complete in all respects... Suitable for 6000 LPM 45 M Head
SEWAGE TREATMENT PLANT Design, construction, erection, testing and commissioning of 2.00 MLD capacity Sewage Treatment Plant based on Sequential Batch Reactor (SBR) Technology complete in all respect including Landscaping MCC Panel room and all other contingent Electrical, Mechanical, Electromagnetic Flow Measurement Device, Real Time Water Quality Monitoring with Data Collection System(Online analyzer), Piping and Instrumentation works. With PLC and SCADA Arrangement for STP and MPS along with Synchronizing it with each other including furniture and laboratory equipments as per detail given in the bid document and including following components including OandM of 5 Years after 12 months defect liability period after 3 months trail run period. 2 No. High Mast of 9 mtr GI Octagonal pole of 4 mm thickness (T=100 mm, B=200mm, Base Plate = 320 x 320 x 20 mm), Window at 500 mm from Base Plate with 6 No. LED energy outdoor suitable size reputed make efficient lamps on each pole, including 20 no. LED outdoor lights with GI poles 7 mtr high including all accessories along the road and path complete in all respect. Supply and installation of 1 No. Main Gate of (MS) 12 ft. wide main gate and 4 ft. wide wicket gate (total weight not less than 500 kg) at STP site. as per satisfaction of Engineer-in-charge. Providing and installing 2 No. centrifuges (1Working plus 1 Stand bye) including centrifuge feed pump, all fittings, instrumentations, electric panel board etc. as per design complete in all respect of the NIT, including packing dry sludge in 20Kg Bag and supplying the same Market Kisan Sewa Kendra or as directed by Engineer-in-charge within lead as posited as clause 4.4.5 of NIT including operation and maintenance of 5 Years after 12 months defect liability period after 3 months trail run period. Providing and installation of 2 nos. pumping sets of suitable size (1 working and 1 standby) with head 15 mtrs. in chlorination tank to disposed off the treated effluent including all fittings, instrumentations, electric panel board etc. as per design complete in all respect including operation and maintenance of 5 Years after 12 months defect liability period after 3 months trail run period. Supply, Installation, Testing, Commissioning, operation and Comprehensive Annual Maintenance of effluent quality monitoring system at 2.00 MLD STP for Online (Continuous) measuring of PH, total Suspended Solids (TSS) Chemical Oxygen Demand (COD), Biological Oxygen Demand (BOD) by single analyzer with various sensors (spectral measurement in the UV-VIS range 200-720mm) performing reagent and chemical free analysis with automatic cleaning of censor, signal cables and power cable, local data acquisition and display the data of continuous basis for up linking the data of CPCB, HSPCB and PHED, TUV Board approved complete in all respect as per Central Pollution Control Board (CPCB) guidelines for online continuous monitoring system for effluents and as contained in scope of work in the notice inviting tender:Multi-parameter measuring converter, for connecting up to 18 intelligent seniors Scope including 8 analog inputs/Outputs(4 Inputs and 4 outputs) (o/4-20Ma), wide range power supply optical COD/BOD and TSS probe with spectral processing of the UV-VIS range for measurement plant of 2.00 MLD STP with integrated with automatic cleaning.Robust digital pH/ORP sensor for pH/ORP electrodes, with built-in pre-amplifier and temperature sensor with Automatic Temperature Compensation (ATC) Cable length 100 Meter (minimum).Sensor adapter cable for all intelligent sensors, with IP68 water proof connection to intelligent sensors net system cable length 100 Meter (Minimum) Data Transfer to CPCB, HSPCB and PHED Servers during 1 year of OandM after commissioning after 3 months trail period (including 1 year of defect liability period). Providing GSM 3G, 4G Modem with mobilenetwork connectivity including network charges for 5 year of OandM after commissioning after 3 Months trail run (after 1 year defect liability period)
Providing ,lowering in trenched to correct gradient and alignments, jointing with tyton rubber joint and cutting of RCC S/S pipes having inside HDPE lining ISI marked as per IS code IS:458-2003 into trenches for all depths and laying out the same to correct alignment, gradients, levels etc cutting of concrete beds and joints holes, supporting the pipes and specials in correct position in a suitable rigid manner while the same are being jointed and until the surroundings benchings, haunches and envelopes are completed. The pipe shall rest on the beds at all joints through their lengths and to ensure this, testing the pipes for leakage and all defects to the entire satisfaction of the Engineer in charge including all cartage etc complete in all respect
MAIN PUMPING STATIONS Design, construction, erection, testing and commissioning of MPS and following components including OandM for 5 years after 1 year defect liability period after 3 months trial run period. Panel room of 30 sqm. covered area and PLC room including toilet block of 20 Sqmtr. covered area with RCC framed structure of brick work vitrified glazed tiles flooring, Powder coated aluminium frame of size 100mm x 45mm of 10 gauge for chowkhat, 75mm x 45mm of 10 gauge for door frame, 45mm x 45mm of 10 gauge for window frame, 5mm thick glass AIS/Saint Gobin/Modi Float, The toilet block shell be with one half staff urinal and One European W/C, one wash hand basin as per approved drawings. RCC Inlet chamber, Screen Chamber, rectangular collecting tank suitable for 2.00 MLD average flow with peak factor of 3.00 land scaping of the campus complete in all respect. K9 DI pipe of suitable dia at MPS Including welding and screwing of flanges, ISI marked D.I. fittings, Sluice valve, non return valves as per requirements even for bye-pass arrangements complete in all respect. 3 nos. CI Gear Operated Sluice Gate with SS Spindle (SS 410) and seats (SS 304) (2 nos. for screen and 1 no. for partition of collecting tank) as per design. Supply installation of 2 nos. mechanical course screens of minimum length 6 mtrs. for 2.00 MLD average flow with peak factor of 3.0.1. The connecting sewer of same diameter and material of construction, laid at adequate depth between existing sewers to newly constructed structures is included in scope of work. 2. All the infrastructure except construction of staff quarter, and path ways/ roads required to be executed at site to make the MPS functional is included in the scope of work for lump-sump job. 3. All the pumping machinery, panel board, Level sensor etc. shall be controlled by PLC and SCADA and shall be synchronized with PLC panels at MPS and STP site through broadband internet facility. 4. The size and quantities of all the above components will be as per approved structural /Hydraulic /Mechanical /Electric design to be approved by Department before actual execution of work including OandM of 5 Years after 12 months defect liability period after 3 months trail run period. ........
Bidder Name
Amount
Lakhan Consturction(GSTN-06CNRPK6783J1Z6)
Jaiveer Singh Contractor(GSTN-06ATQPS8420H1Z8)
Jaiveer Singh Contractor
Jaiveer Singh Contractor
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .