| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.2 LAdmitted-Finance NO 1 4 56 Y SRI BHARATHI NAGAR OPP PARVATHI THEATER CUMBUM ROAD THENKARAI PERIYAKULAM THENI DT 625 601 | PERIYAKULAM | THENI | TAMIL NADU | 625601 | L1 | Admitted-Finance | |
| 2 | L2₹30.8 L+₹2.6 L (9.17%)Admitted-Finance | L2 | Admitted-Finance | |
| 3 | L3₹30.9 L+₹2.7 L (9.58%)Admitted-Finance 101 1ST FLOOR JASOL RESIDENCY 14TH CROSS KANAKANAGAR R T NAGAR POST BANGALORE 560032 | BANGALORE | BANGALORE | KARNATAKA | 560032 | L3 | Admitted-Finance | |
| 4 | L4₹34.1 L+₹5.8 L (20.7%)Admitted-Finance | L4 | Admitted-Finance | |
| 5 | L5₹36.1 L+₹7.8 L (27.7%)Admitted-Finance KG 115 SABIRA MANZIL HBR 2ND STAGE VENKATESH PURAM BANGALORE 560 045 | BENGALURU URBAN | KARNATAKA | 560045 | L5 | Admitted-Finance |
| Sl No | Description | Qty | Unit | GS TRADERS L5 | Vasavi Electricals L3 | PRIYADARSHINI CONSTRUCTIONS L1 | S S BUILDERS L6 | M S K CONSTRUCTION L4 | NRN GROUP L2 |
|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Taking down carefully aluminium/ copper point wiring/power point wiring, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. complete and making good the disturbed surface to match adjoining surfaces complete all as specified and as directed. | 1,686 | Per Point | 15 ₹25,290 | 8 ₹13,488 | 7 ₹11,802 | 50 ₹84,300 | 2 ₹3,372 Lowest | 40 ₹67,440 |
| 2.00M & L for Point Wiring with PVC insulated unsheathed 1.5 Sqmm single core 1100 volts grade multi stranded FRLS copper conductor cable conforming to IS 694 drawn through and including non-metalic rigid PVC conduit medium grade ISI marked with accessories concealed in walls including MS terminal boxes fabricated with 1.6 mm thick MS sheet concealed in walls with laminated sheet top cover 3 mm thick fixed with cadmium plated iron screws for housing the switches, switch socket outlets, fan regulators etc., including 1.5Sqmm PVC insulated single core multi stranded copper conductor cable as earth continuity conductor and connecting to common earth dolly, .for the following all as specified and as directed :- | |||||||||
| 2.10 | One light point controlled by one switch | 220 | Per Point | 625 ₹1,37,500 | 545 ₹1,19,900 | 600 ₹1,32,000 | 740 ₹1,62,800 | 650 ₹1,43,000 | 450 ₹99,000 Lowest |
| 2.20 | One fan point controlled by one switch/regulator | 110 | Per Point | 625 ₹68,750 | 545 ₹59,950 | 600 ₹66,000 | 740 ₹81,400 | 550 ₹60,500 | 450 ₹49,500 Lowest |
| 2.30 | One light point controlled by 2 way switch | 9 | Per Point | 750 ₹6,750 | 645 ₹5,805 | 650 ₹5,850 | 780 ₹7,020 | 650 ₹5,850 | 550 ₹4,950 Lowest |
| 2.40 | One 3 pin socket out let 5 Amps on independent board | 35 | Per Point | 625 ₹21,875 | 545 ₹19,075 | 600 ₹21,000 | 750 ₹26,250 | 700 ₹24,500 | 450 ₹15,750 Lowest |
| 2.50 | One bell/buzzer point controlled by bell push | 25 | Per Point | 625 ₹15,625 | 545 ₹13,625 | 600 ₹15,000 | 740 ₹18,500 | 400 ₹10,000 Lowest | 450 ₹11,250 |
| 2.60 | One 3 pin socket out let 5 Amps on same board with other switches | 55 | Per Point | 100 ₹5,500 Lowest | 100 ₹5,500 Lowest | 100 ₹5,500 Lowest | 200 ₹11,000 | 300 ₹16,500 | 195 ₹10,725 |
| 3.00M & L for Point Wiring with PVC insulated unsheathed 1.5 Sqmm single core 1100 volts grade multi stranded with FRLS copper conductor conforming to IS 694 drawn through and including non-metalic rigid PVC conduit medium grade ISI marked with accessories concelaed type wiring including GI/ MS branded sunken boxes of suitable module concealed on walls including modular frame and cover of suitable module fixed with cadmium plated iron screws for housing modular type switches, switch socket outlets, fan regulators etc., including PVC insulated single core multi stranded copper conductor cable 1.5 Sqmm as earth continuity conductor and connecting to common earth dolly, for the following all as specified and as directed :- | |||||||||
| 3.10 | One light point controlled by one switch | 160 | Per Point | 675 ₹1,08,000 | 575 ₹92,000 | 600 ₹96,000 | 740 ₹1,18,400 | 850 ₹1,36,000 | 450 ₹72,000 Lowest |
Tender Value
₹42 L
EMD Value
₹84,000
Closing Date
13 Jan 2026, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE (ARMY) BANGALORE
CWE (ARMY) BANGALORE, 101, DICKENSON ROAD, BANGALORE - 560042
REPAIR/REPLACEMENT OF INT WIRING, ELEC FITTING AND FIXTURES, RENEWAL OF BLDG EARTHING AND OTH CONNECTED ITEMS, REPAIR/REPLACEMENT CEILING FANS, EXHAUST FANS, GEYSERS AND OTHER CONNECTED ITEMS IN OTM/MD ACCN AT DGQA AND NAVY AREA UNDER GE(N) BANGALORE
2025_MES_745846_1
86466/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
CWE (ARMY) BANGALORE
AS PER TENDER
8 documents required · 8 mandatory
₹500
GE (NORTH) BANGALORE
₹84,000
27 May 2026
23 Dec 2025
20 Jan 2026
23 Dec 2025
13 Jan 2026
6 Jan 2026
23 Dec 2025 - 30 Dec 2025
Taking down carefully aluminium/ copper point wiring/power point wiring, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. complete and making good the disturbed surface to match adjoining surfaces complete all as specified and as directed.
M & L for Point Wiring with PVC insulated unsheathed 1.5 Sqmm single core 1100 volts grade multi stranded FRLS copper conductor cable conforming to IS 694 drawn through and including non-metalic rigid PVC conduit medium grade ISI marked with accessories concealed in walls including MS terminal boxes fabricated with 1.6 mm thick MS sheet concealed in walls with laminated sheet top cover 3 mm thick fixed with cadmium plated iron screws for housing the switches, switch socket outlets, fan regulators etc., including 1.5Sqmm PVC insulated single core multi stranded copper conductor cable as earth continuity conductor and connecting to common earth dolly, .for the following all as specified and as directed :-
One light point controlled by one switch
One fan point controlled by one switch/regulator
One light point controlled by 2 way switch
One 3 pin socket out let 5 Amps on independent board
One bell/buzzer point controlled by bell push
One 3 pin socket out let 5 Amps on same board with other switches
M & L for Point Wiring with PVC insulated unsheathed 1.5 Sqmm single core 1100 volts grade multi stranded with FRLS copper conductor conforming to IS 694 drawn through and including non-metalic rigid PVC conduit medium grade ISI marked with accessories concelaed type wiring including GI/ MS branded sunken boxes of suitable module concealed on walls including modular frame and cover of suitable module fixed with cadmium plated iron screws for housing modular type switches, switch socket outlets, fan regulators etc., including PVC insulated single core multi stranded copper conductor cable 1.5 Sqmm as earth continuity conductor and connecting to common earth dolly, for the following all as specified and as directed :-
One light point controlled by one switch
One fan point controlled by one switch/regulator
One light point controlled by 2 way switch
One 3 pin socket out let 5 Amps on independent board
One bell/buzzer point controlled by bell push
One 3 pin socket out let 5 A on same board
All as per item No 2 herein before but concealed wiring drawn through existing PVC conduit for following :-
One light point controlled by one switch
One fan/Exhaust point controlled by one switch/regulator
One light point controlled by 2 way switch
One 3 pin socket out let 5 Amps on independent board
One bell/buzzer point controlled by bell push
One 3 pin socket out let 5 A on same board with other switches
M & L for Point Wiring with PVC insulated unsheathed 2.5 Sqmm single core 1100 volts grade multi stranded with FRLS copper conductor cable conforming to IS 694 drawn through non-metalic existing PVC conduit run on walls/ ceiling incl MS terminal boxes fabricated with 1.6 mm thick MS sheet surface mounted/ concealed on walls with plastic laminated sheet top cover 3 mm thick fixed with cadmium plated iron screws for housing the switches, switch socket outlets, fan regulators etc., including PVC insulated 2.5 Sqmm single core multi stranded copper conductor cable as earth continuity conductor and connecting to common earth dolly, all as specified and as directed.
M & L for Sub main wiring with two runs of 4 Sqmm single core PVC insulated FRLS copper multistranded cable 1100 volts grade with one run of 4 sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable as earth continuity conductor, drawn through existing non metallic rigid PVC conduit and conduit accessories all as specified and as directed.
M & L for surface Point Wiring with PVC insulated unsheathed 1.5 Sqmm single core multi stranded FRLS copper conductor cable 1100 volts grade conforming to IS 694 drawn through and including PVC Casing & Caping ISI marked with accessories surface type wiring including 1.6 mm thick MS sunken boxes concealed in walls including laminated sheet top cover 3 mm thick fixed with cadmium plated iron screws for housing the switches, switch socket outlets, fan regulators etc., including PVC insulated single core multi stranded copper conductor cable 1.5 Sqmm as earth continuity conductor and connecting to common earth dolly for the following all as specified and as directed :-
One light point controlled by one switch
One fan point controlled by one switch/regulator
One light point controlled by 2 way switch
One 3 pin socket out let 5 Amps on independent board
One bell/buzzer point controlled by bell push
One 3 pin socket out let 5 A on same board
M & L for Point Wiring with PVC insulated unsheathed 2.5 Sqmm single core multi stranded FRLS copper conductor cable 1100 volts grade conforming to IS 694 drawn through and including non-metalic PVC conduit medium density ISI marked with accessories concealed type run on walls/ ceiling including MS terminal boxes fabricated with 1.6 mm thick MS sheet concealed on walls with plastic laminated sheet top cover 3 mm thick fixed with cadmium plated iron screws for housing the switches, switch socket outlets, fan regulators etc., including PVC insulated single core multi stranded copper conductor cable 2.5 Sqmm as earth continuity conductor and connecting to common earth dolly, all as specified and as directed.
M & L for Point Wiring with PVC insulated unsheathed 2.5 Sqmm single core multi stranded FRLS copper conductor cable 1100 volts grade conforming to IS 694 drawn through and including PVC casing caping ISI marked with accessories surface type wiring run on walls/ ceiling including MS terminal boxes fabricated with 1.6 mm thick MS sheet concealed on walls with plastic laminated sheet top cover 3 mm thick fixed with cadmium plated iron screws for housing the switches, switch socket outlets, fan regulators etc., including 2.5Sqmm PVC insulated single core multi stranded copper conductor cable as earth continuity conductor and connecting to common earth dolly, all as specified and as directed. Note for Item No 2 to 9:- (i) The earth wire for the points in the same circuit can be looped from point to point (ii) Earth wire shall be taken inside the conduit (iii) Cost of terminal box is deemed to be included in the item rate quoted for point wiring (iv) Cost of a circuit of any length of cable from DB to any switch/ socket board to be included in point wiring. (v) Quoted rate to be included cutting chases for conduits and making good to walls wherever item described.
S&F LED batten with luminaire suitable for indoor applications 20 Watts capacity, 4 feet long with extruded aluminium housing & integrated LED channel complete with all accessories all as specified and directed. (Make: Bajaj, Cat No.BCLAB 20 WH LED P or equivalent Makes specified in P S herein after)
S&F LED batten with luminaire suitable for indoor applications 10 Watts capacity, 2 feet long with polycarbonate housing & integrated LED channel with white arcylic cover complete with all accessories all as specified and directed. (Make: Bajaj, Cat No.BCLSB 10 WH or equivalent Makes specified in P S herein after)
S&F Recess mounted LED Luminaire of size 2' x 2', capacity 36 Watts, white powder coated CRCA housing with LEDs seamless front frame with flat white high transmission arcylic cover complete with all accessories as specified and directed. ( Make: Bajaj, Cat No : BZRSQL 36W GZi WH or equivalent Makes specified in P S herein after)
S&F Surface mounted LED Luminaire of size 1' x 1', capacity 24 Watts, white powder coated CRCA housing with LEDs seamless front frame with flat white high transmission arcylic cover complete with all accessories all as specified and directed. (Make: Bajaj, Cat No : BZSSQL 24W LED WHI or equivalent Makes specified in P S herein after)
S&F Wall mounted Bulkhead LED luminaire 10 watt capacity, powder coated pressure die-cast aluminium alloy housing with IP 65 protection as specified and directed. (Make: Bajaj, Cat No : BIBWP10WLED or equivalent Makes specified in P S herein after)
S&F Modular switch 1 way 6Amps, 1 module all as specified and directed.
S&F Modular switch 1 way 16Amps , 1 module all as specified and directed.
S&F Modular switch 2 way 6Amps, 1 module all as specified and directed.
S&F Modular Bell push 6Amps 1 module all as specified and directed.
S&F Modular Socket, 6Amps - 2/3 pin combined, 2 module all as specified and directed.
S&F Modular Socket 6Amps /16Amps - 2/3 pin combined 2 module, all as specified and directed.
S&F Modular type fan step regulator, 120W - 2 module all as specified and directed.
S&F Switch piano type, flush button single pole, two way 5 Amps all as specified and as directed.
S&F Angle holder PVC/polycarbonate type all as specified and as directed
S&F Switch piano type, flush type single pole one way 5 Amps all as specified and as directed
S&F switch socket combination 5 pin 2 in 1, 5 Amps Flush type all as specified and as directed
S&F Switch socket combination 2 in 1, 3 pin 5 and 15 Amps flush type universal all as specified and as directed
S&F socket outlet 2 in 1, 3 pin 5 Amps all as specified and as directed
S&F Bell push flush type 5Amps all as specified and as directed .
S&F in replacement MCB SPN 32/40 Amps 240 volts C curves complete all as specified and as directed
S&F in replacement MCB single pole 10/16/20/32 Amps 240 volts C curves complete all as specified and as directed
S&F in replacement MCB TPN 415 volts, 10KA 'C' curve 63 Amps complete all as specified and as directed
S&F in replacement MCB TPN 415 volts, 10KA 'C' curve 100 Amps complete all as specified and as directed
S&F in replacement of MCB Distribution board SPN 4 way, double door type, 240 volts with 200 Amps rated busbar as specified and as directed.
S&F in replacement of MCB Distribution board SPN 8 way, double door type, 240 volts with 200 Amps rated busbar as specified and as directed.
S&F in replacement MCB Distribution board TPN 4 way, double door type, 415 volts with 200 Amps rated busbar for housing MCBs as specified and as directed.
S&F Ceiling rose, surface bakelite type 65 x 50 mm, 2 to 3 terminals all as specified and as directed
S&F Stepped type electronic fan regulator, flush type, Switch/socket type all as specified and as directed
S&F in replacement Ding Dong bell AC 230 volts single pole all as specified and as directed
S&F in repair sub main wiring 1100 volts grade multistranded FRLS copper conductors, two runs of single core 6 Sqmm along with 6 Sqm PVC insulated single core multistranded copper conductor cable as earth continuity conductor run along with PVC conduit all as specified and as directed (Note : Three run of 6sqmm cable and one run of PVC conduit altogether measured as one unit)
S&F in repair sub main wiring 1100 volts grade multistranded FRLS copper conductors, two runs of single core 4 Sqmm along with 4 Sqm PVC insulated single core multistranded copper conductor cable as earth continuity conductor run along with PVC conduit all as specified and as directed (Note : Three run of 4sqmm cable and one run of PVC conduit altogether measured as one unit)
S&F in repair sub main wiring 1100 volts grade multistranded FRLS copper conductors, two runs of single core 2.5 Sqmm along with 2.5 Sqm PVC insulated single core multistranded copper conductor cable as earth continuity conductor run along with PVC conduit all as specified and as directed (Note : Three run of 2.5sqmm cable and one run of PVC conduit altogether measured as one unit)
M & L for earthing with galvanized steel earth plate electrode 60 cm x 60 cm x 6mm thick buried directly in ground vertically to a depth not less than 2.25 mtr below ground level with top edge of earth plate at a depth not less than 1.5 mtr connected to galvanized earth lead wire 4 mm dia as earth lead up to 7.5 mtr long by means of nuts, bolts, thimbles,check nuts and washers etc made of galvanized iron connected to earthing test point all as shown in electrical plate No 3 of SSR Part-I 2010 and as specified or indicated and testing on completion including earth work and excavation in any type of soil, PCC (1:3:6) type C1 chamber, pre cast slab 40mm thick in cement concrete (1:2:4) type B1 with 8 mm dia TMT bars reinforced at 10 cm centre to centre both ways, funnel with watering pipe wire mesh and lugs, test point complete all as specified and as directed.
S&F in repairs LED lamp suitable to fit in angle holder of capacity 09 watts all as specified and as directed.
S&F in repairs bldg security light fitting of capacity 30 Watts LED luminaire with pressure die cast housing along with prismatic polycarbonate difuser with IP 66 protection all as specified and as directed
S&F in repairs Luminaire Bracket made out of G I tubing medium grade 25 mm bore , approx length 1.5 m long including MS clamps made out of MS flat iron 25 x 6 mm, nuts, bolts, washers etc and applying two coats of aluminum paint over a coat of red oxide primer complete all as specified and directed.
S&F in repairs Storage type water heater 25 Ltrs capacity BEE 5 star rated including steel wired pipe connection for hot/cold water supply for inlet and out let water, storage type steel body with copper inner tank and heating element upto 2 KW capacity with all accessories such as safety valve, thermostate, NRV etc complete all as specified and directed.
S&F in repairs ceiling fans with complete accessories, 230Volts, SP 1200 mm Sweep with BEE 3 Star rating complete, fixing the fan from ceiling rose with 3 core flexible copper wire 24/0.20 sqmm, etc all as specified and as directed
S&F in repairs Exhaust fans AC single phase 230/ 240 Volts of size 300 mm sweep, steel body AC single Phase. 230Volts with, blades, and frame and louvers fixed outside with all accessories and fixing the exhaust fan from ceiling rose with 3 core flexible copper wire 24/0.20 sqmm , etc all as specified & directed.
S&F in repairs PVC Fresh air fan of 250mm sweep 1200/1400 RPM with louver, and fixing the fan from ceiling rose with 3 core flexible copper wire 24/0.20 sqmm etc complete all as specified & directed.
S&F in repairs PVC Fresh air fan of 200mm sweep 1200/1400 RPM with louver, and fixing the fan from ceiling rose with 3 core flexible copper wire 24/0.20 sqmm etc complete all as specified & directed.
S&F in repairs PVC Fresh air fan of 150mm sweep 1200/1400 RPM with louver, and fixing the fan from ceiling rose with 3 core flexible copper wire 24/0.20 sqmm etc complete all as specified & directed.
S&F in repairs Motor for BAHAR METALLIC GREY exhaust fans 280/300 mm sweep, heavy duty, 1400 RPM, AC single phase 230/240 Volts with blades complete all as specified and directed.
S&F in repairs Motor for exhaust fans 300/230 mm sweep, heavy duty, 1400 RPM, AC single phase 230/240 Volts with blades complete all as specified and directed.
S&F in repairs outer frame suitable for exhaust fan holding exhaust fan motor upto 280 mm sweep with supporting angle complete all as specified and directed.
S&F in repairs outer frame suitable for exhaust fans holding exhaust fan motor upto 300/230 mm sweep with supporting angle complete all as specified and directed.
S & F in repairs louver suitable for exhaust fan 300/230 mm sweep with accessories all as specified and directed
S & F in repairs louver suitable for exhaust fan 450 mm sweep with accessories all as specified and directed
S&F in repairs of Single pole & neutral sheet metal enclosure 20 Amps & 240 Volts with two pin and earth plug and socket complete with one single pole MCB 20 Amps C curves all as specified & directed.
Inspection, taking down, dismantling of geysers of any type/capacity, cleaning, descaling, including hydraulic pressure test of container with hand operated hydraulic pump, brazing inner tank, internal wiring and re-assembling & reinstallation on the original place after necessary repair/replacement of old parts all as specified & as directed. (Note : Replacement of old parts shall be measured as supply only & paid separately.)
Supply only stainless inner tank of capacity 25 ltrs including internally assembly of any type complete all as specified & as directed.
Supply only internal assembly/apparatus rod unit of any type of capacity 25 ltrs complete all as specified & as directed.
Supply only heating element of 2 KW rating triangular / round type as per existing size and type including rubber washers all as specified & as directed.
Supply only heating element of 2 KW rating Hexagonal spiral/bend type as per existing size and type including rubber washers all as specified & as directed.
Supply only Thermostat auto cut off of suitable size and type for 25/50 Ltrs capacity of any type all as specified & as directed.
Supply only Indicator lamp red and green colour square/round all as specified & as directed.
Supply only Safety valve / high pressure valve / NRV of exisitng type, ISI marked, all as specified & as directed.
Supply only PVC insulated Copper cable flexible 3 core of size 40/0.0076 ISI marked.
Supply only outer cover of geyser of capacity 25 ltrs complete with all fitting and fixtures as specified & as directed.
Supply only PVC flexible pipe 16mm dia 450mm long with 2 Nos of brass ferrule & rubber washer for hot and cold water all as specified & as directed.
M&L for taking down the geyser of 25/50ltr capacity, preparation old painted surface of Geyser & spray painting with one coat of synthetic enamel paint using spray gun including writing MES No and refixing back in same or other place complete all as specified & as directed.
Taking down ceiling fan 1200mm/1400mm sweep duly disconnecting electric lines, preparing the surfaces, filling cavities with filler, cleaning all dust and spray painting one finishing coat of synthetic enamel paint including writing MES NO and replacing the split pin, rubber pulley etc., including refixing and connecting the same complete all as specified and as directed.
Taking down wall mounted fan 300/450 mm sweep duly disconnecting electric lines, preparing the surfaces, filling cavities with filler, after cleaning all dust, spray painting with one finishing coat of synthetic enamel paint including writing MES NO etc., including refixing and connecting the same complete all as specified and as directed.
Inspection, disconnecting electric connection and dismantling of ceiling fan/exhaust/wall mounted fan of any type/size, cleaning including oiling and greasing the bearing, tightening of nuts and bolts, re-winding if required, and refixing on the old place after necessary repair / replacement of old parts all as specified & as directed. (Note : Replacement of old parts shall be measured as supply only & paid separately.)
Supply only ball bearing of various sizes / make as required for ceiling fans/wall mounting/exhaust fan including greasing complete all as specified and as directed.
Supply only Gun metal bush of any size/make suitable for ceiling fans all as specified and as directed.
Supply only capacitor 2.5 Mfd suitable for ceiling / exhaust /wall mounting fans complete all as specified and as directed.
Supply only capacitor 4.0 Mfd suitable for ceiling / exhaust/wall mounting fans complete all as specified and as directed.
Supply only PVC flexible cable twin twisted core of 23/0.0076 size multi stranded copper conductor suitable for connecting ceiling fans / exhaust /wall mounting fans complete all as specified and as directed.
Supply only Rubber bush with MS bolts, nuts & washers with 'U' clamps for ceiling fans complete all as specified and as directed.
Supply only motor rotar ring for ceiling fans complete all as specified and as directed.
Supply only motor stator for ceiling fans complete all as specified and as directed.
Supply only down rod of 30/45 cm with nut, bolts and safety pin for ceiling fans complete all as specified and as directed.
Supply only plastic cup with screw for ceiling fans complete all as specified and as directed.
Dismantling / opening the ceiling fan of 1200 mm sweep of any make and type, removing the old defective winding carefully, cleaning the inner parts and rewinding with the same gauge supper enamelled copper conductor of good insulation, varnishing, drying and re-assembling complete all as specified and as directed.
Dismantling /opening the ceiling fan of 1400 mm sweep of any make and type, removing the old defective winding carefully, cleaning the inner parts and rewinding with the same gauge supper enamelled copper conductor of good insulation, varnishing, drying and re-assembling complete all as specified and as directed.
Dismantling /opening the wall mounted fan of 300 mm sweep of any make and type, removing the old defective winding carefully, cleaning the inner parts and rewinding with the same gauge supper enamelled copper conductor of good insulation, varnishing, drying and reassembling complete all as specified and as directed.
Taking down exhaust fans 230 mm/300mm / 450mm sweep from position duly disconnecting electric lines, preparing the surfaces, filling cavities with filler, cleaning all dust, spray painting with one finishing coat of synthetic enamel paint including writing MES NO, re-winding if required, and replacing the split pin, rubber pulley etc., refixing and connecting complete all as specified and as directed.
Dismantling /opening the exhaust fan of 230 mm/300 mm sweep of any make and type, removing the old defective winding carefully, cleaning the inner parts and rewinding with the same gauge supper enamelled copper conductor of good insulation, varnishing, drying and re-assembling complete all as specified and as directed.
Dismantling /opening the exhaust fan of 450 mm sweep of any make and type, removing the old defective winding carefully, cleaning the inner parts and rewinding with the same gauge supper enamelled copper conductor of good insulation, varnishing, drying and re-assembling complete all as specified and as directed.
M&L for Extension of down rod for ceiling fan upto 1.5 mtr including nut, bolts , washers complete accessories all as specified and as directed.
Removing the window type AC/Split type AC of 1.0/1.5/2.0 ton capacity from location servicing the AC, cleaning the condenser and evaporator coil by blower, checking the electrical wiring, repalcement of burnt out wiring terminals, cleaning the air filter, gas charging, adjusting relays etc., replacement of unserviceable spare parts and fixing back at location, testing for smooth functioning and commissioning complete all as directed.
Supply and fix PVC insulated 3 core 2.5 Sqmm multi stranded copper conductor cable complete all as directed.
M & L for taking down the split type Air Conditioner of any make from position transporting to a reputed workshop, cutting the suction and discharge line of unserviceable compressor and replace with new factory made hermatically sealed compressor of same make and type, connecting the suction and discharge line, vacuuming the entire system, arresting all leakages, charging of required quantity of refrigerant, adjusting relays, thermostat etc bringing back and installing in its original position including testing for smooth functioning and commissioning for the following capacities complete all as directed :-
1.5 ton capacity
2.0 ton capacity Note for item No 70 :- (i) Charging of Gas & supply of Gas will be measured and paid separately under relevent items of this schedule. (ii) Spares will be measured and paid seperately under relevent item of this schedule.
Labour only for charging of refrigrent gas (R-22/410A/134A) of required quantity for split/window type AC including leak detection by using nitrogen gas and arresting leakages if any by necessary brazing and flushing the system complete and testing complete for the following capacities:
Supply only fan blades from the condenser motor shaft of same size and type for any capacity of window type AC and water coolers all as specified and directd.
Supply only thermostat of same make and type for Split/window type AC 1.5/2 ton capacity all as specified and directd.
Taking down blower motor from the window type AC/Spilit type AC, removing the burnt out winding from slots, rewinding with superior quality copper winding wire of higher insulation level, varnishing drying the motor complete and fixing in position incl testing and commissioning for 1.5/2 ton capacity Air conditioner all as specified and directd.
Supply only condenser unit connecting to the discharge line, brazing, vaccumising & gas charging the unit with required quantity of refrigerant for Split/window type AC of 1.5/2 Ton capacity and testing complete all as specified and directd.
Supply only running capacitor of 40 MFD suitable for 1.5 ton AC all as specified and directd.
Supply only starting capacitor of 80/100 MFD for 1.5 TR / 2 TR AC all as specified and directd.
Supply only over load protection for split/window type AC of 1.5/2.0 TR capacity all as specified and directd.
Supply only refrigrent gas (R-22/410A/134A) for domestic cooling appliance all as specified and directd..
Supply only sensor unit of indoor unit of AC of following capacities to suit the AC Makes carrier/Bluestar/Voltas all as specified and directd :-
1.5 Ton Split type AC
2 Ton Split type AC
Supply only PCB for split AC of following capacities any type and make all as specified & directed :-
1.5 Ton Split type AC
2 Ton Split type AC
Taking out PCB from split type Air Conditioner 1.5/2 Ton capacity and repair the same and refixing in original position, testing for smooth functioning complete all as specified and directed.
Disconnect the all electrical connection, removing copper line, discharge line of split type Air conditioner upto 2 Ton capacity alongwith indoor and out door units and all accessories and shifting/reinstalling the whole unit of split type AC in new location with suitable size and length of copper pipe and making the holes in walls etc and testing for smooth functioning complete all as specified & directed.
Supply and fix plastic / coir filter suitable for Split/window type AC 1.5/2 Ton capacity including taking down old unserviceable filter etc complete all as specified and as directed.
Supply and fix voltage stabilizer suitable of following capacity for Split/window type AC 1.5/2 Ton capacity, operate input range 130 volt to 280 volts, automatic voltage regualation, surge protection etc complete all as specified and as directed :-
S&F in replacement of brass angle valve for gas charging for split Air conditioner of capacity 1.5/2 ton compete all as specified and as directed.
S&F in replacement of brass flare nuts suitable for 1.5/2 ton of Split AC complete all as specified and directed.
S&F in replacement of swing motor of existing capacity and type for indoor unit of split Air conditioner fins complete all as specified and as directed
S&F in replacement of Mild steel fabricated clamps for hanging fan including hook as per existing complete all as specified and as directed
Supply and fix Refrigerator electric driven (single phase), capacity 310 Litres, double door BEE 5 star rated, inverter compressor, frost free, toughened glass shelfs, complete all as specified and as directed.
Supply and install Hi wall split units indoor / outdoor with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality with minimum 3 star rating and EER 3.2 of capacity 1.5 TON Air Conditioner complete all as specified and as directed.
S&F in replacement of Nitrile rubber insulation for suction and dischaged pipe of split type AC of size 15/19 mm dia complete all as specified and as directed.
S&F in replacement of Soft copper tubing 15mm/19 mm dia with nitrile rubber insulation for split type AC complete all as specified and as directed.
S&F in repair capacitor 2.5 Mfd suitable for ceiling / exhaust /wall mounting fans complete all as specified and as directed.
M&L for groove cutting in wall/floor and making good of distrubed wall/floor with PCC (1:2:4) type B-0 and finishing as per adjoining surfaces all as specified and directed.
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
cancelled_1.pdf
pdf • 0.29 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.50 MB
tender86466.pdf
Tender Documents • 1.18 MB
BOQ_835156.xls
BOQ • 1.11 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .