Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.4 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹30.2 L+₹1.2 L (4.21%)Rejected-AOC | L2 | Rejected-AOC L2 |
Tender Value
₹43 L
EMD Value
₹86,000
Closing Date
13 Sept 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Bharatpur
GE Kanjoli line Bharatpur-321026
Spl Rep of ESHs No 8 and ESHs No -28 at 1ASD of 39 FAD under GE Bharatpur
2024_MES_667695_1
8413/E8
Open Tender
Civil Works
Item Rate
180 days
GE Bharatpur
As per NIT
7 documents required · 7 mandatory
₹500
Yes
GE Bharatpur
₹86,000
Yes
3 Oct 2024
24 Jul 2024
16 Sept 2024
24 Jul 2024
13 Sept 2024
8 Aug 2024
25 Jul 2024 - 7 Aug 2024
Amount
M&L for removal of existing treatment by taking out loose/spalled out waste material by chiselling chippings etc from beam, wall, columns,ceiling, band etc. including use and waste of form work and providing steel wire fabric mesh of size 75mm X 75mm of dia 3.15mm fixed by L shaped mild steel shear key welded with existing reinforcement and providing 75mm thick concrete (1:1.5:3) type 0 using graded stone aggregate of 10mm maximum size mixed with polymeric admixture with pressure nozzle (guniting) and finishing the surface in CM (1:3) surface finished even and smooth without using extra cement and removing the debris outside MD land complete all as specified and directed. Note:- Quoted rates shall deemed to be inclusive of all form work and scaffolding or other handy T&P required to make up proper shape and size of columns/ Pillars, beam and wall partition etc.
M&L for preparing surfaces for roof treatment by removing all loose gravel, dirt,oil, grease and foreign matter by jet of dry air and clean the surfaces mechanically or by grinding to make it smooth before application , rerpair all cracks by cutting V groove and fill with PMC mortar (polymer modified cement mortar ) prepared in ratio as per manufacturers specification provide 75mm x 75mm coving made out of PMC mortar as above on all joints of vertical upstand to ensure that moisture content in the prepared surfaces does not exceed 5% immediately before application of liquid membrane. Material incorporation & PROTECTION BE PROVIDED AS TERRASHEILD FIRST APPLY WITH WATER ( RATIO TERRASHEILD: WATER will be 4 : 1) as primer with coverage area 0.1kg per Sqm. After 2-3 hours later, second step apply directly first coat of terrasheild 0.30 to 0.40 mm thickness coverage area 0.5 to 0.75 kg per Sqm with roller. spread non woven geo textile of 40/50gsm with overlap of 50mm in both direction when the surface is still tacky. After 4-6 hours later, apply third step apply directly second coat of terrasheild 0.30 to 0.40 mm thicknbess coverage area 0.5 to 0.75 kg per Sqm with roller. Final thickness of complete treatment should be min 1.0mm. water tank and khurra location one additional coat of terasheild .30 to .40 mm thickness coverage area 0.5 to 0.75 kg per Sqm be provideds. after complete application will be done authorised applicator from manufacturer and manufacturer's application.
M&L for screed bed or bedding layer of cemnt mortar 1 : 4, 20mm thick finished even and smooth without using extra cement complete all as specified and directed.
Demolition of cement concrete (un-reinforced) in ground floors and pavings n.exc 15 cm thickness (below or above GL) complete all as specified and directed.
M&L for 100mm thick Cement concrete type B-1, 1 : 2 : 4 (20mm graded aggregate) as in floors, pavings etc and finishing even and smooth ( without using extra cement ) complete all as specified and directed.
M&L for preparation and two coat of synthetic enamel paint over any type of steel & iron Surfaces of any description, over 10cm in width or girth,complete all as specified and directed.
M&L for rendering 10 mm thick in CM (1:6) on other than fair faces (internal wall) of brick masonary or concrete surface of wall, finished even & smooth, without using extra cement, including taking down, raking out joints, hacking for key, scrubbing down with water etc of cement plaster, complete all as specified and directed.
M&L for rendering 15 mm thick in CM (1:4) mixed with WPC but fair faces of brick wall (External wall) , finished even & smooth, without using extra cement , including taking down, raking out joints, hacking for key, scrubbing down with water etc of cement plaster, complete all as specified and directed. complete all as specified and directed. Note:- Water proofing compound shall be measured and paid separately.
Supply only Integral WPC.
M&L for preparation of new plastered surfaces and applying thouroughly wetted surface to ensure better sticking including sand paper gentle rubbing to obtain smooth surfaces, including all necessary arrangement for execution of work and applying two coats of exterior weather proof paint(APEX) in camouflaging pattern with roller application over one coat of water based white pigmented akali resistant priming paint for external wall , complete all as specified and directed.
Complete removal of existing treatment on Wall including washing rubbing down and stopping of distempered and painted surface and preparing old surface applying thouroughly wetted surface to ensure better sticking including sand paper gentle rubbing to obtain smooth surfaces, including all necessary arrangement for execution of work and applying two coats of exterior weather proof paint(APEX) in camouflaging pattern with roller application over one coat of water based white pigmented akali resistant priming paint for external wall , complete all as specified and directed.
M&L preparation of new plastered surface and applying two coat of distemper oil emulsion over one coat of water based white pigmented alkali resistant priming paint over 1 mm thick internal wall care putty conforming to IS:109-1968 white or tinted on ceiling & wall complete all as specified and directed.
Complete removal of existing treatment on walls including washing rubbing down and stopping of distempered and painted surface and preparing old surface applying two coats of oil bound over one coat of alkali resistant primer over 1 mm thick internal wall care putty incl preparing by rubbing etc complete with roller application
Complete removal of existing treatment on ceiling including washing rubbing down and stopping of distempered and painted surface and preparing old surface applying two coats of oil bound over one coat of alkali resistant primer over 1 mm thick internal wall care putty incl preparing by rubbing etc complete all as specified and directed.
M&L for greasing and easing of rolling shutter of size not exc 13 Sqm alongwith the guide channel, helical spring, anchoring and all other as to work the shutter in eary way complete all as specified and directed.
M&L for Framed work as in doors or gates, vent, etc of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for fixing hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete all as specified and directed.
S&F in repair for galvanised mild steel wire cloth, 0.63 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with tinned tacks or galvanised wire staples complete all as specified and as directed .
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed.
Excavation in trenches in soft/loose soil not exceeding 1.5m wide and not exceeding 1.5 metre in depth and getting out for laying of cable etc. complete all as specified and directed.
Returning, filling in soft/loose soil including spreading, levelling, watering and well ramming, in layers not exc 25 cm complete all as specified and directed.
Removing of surplus soil to a distance not exc. 50 metre and depositing where directed at a level not exc.1.5 metre above the starting point complete all as specified and as directed.
Taking out of old unsv earthing from existing position , dismantling the same complete all as specified and directed. Note Only Earthing material goes to schedule of credit except GI strip
Material and labour for bore well earthing with the help of mechanical boring machine of 150mm dia 30mtr depth, supply and fix 150 mm bore , UPVC pipe 6 kg/sqcm rating, 06 mtr long with the help of suitable size clamp with nut bolt and washer -01no including charcoal dust, salt fill in bore well for achieve earth conductivity less than 1 ohm. M&L for covering of bore well mouth with PCC (1:2:4) type B-1/Brick masonry pit of size 45x45x45 cm complete and give the mimimum earth test result below 1 ohm complete all as specified and directed by Engineer-in-Charge. Note :- (i) The earth pit shall be refilled by boulders free from vegetable soil.(ii) Earthing shall be tested by contractor in presence of Engr-in-charge. Record shall be maintained.Payment shall be admissible only after satisfactory test results. (iii) GI pipe electrode and GI strip shall be measured & paid separately.
Supply & lowering of GI tubing 50mm dia medium grade in incl necessary fittings for lowering in borewell of depth upto 30 mtr and providing necessary holes in pipe to achieve good earth conductivity complete all as specified and directed.
Taking down old Unserviceable aluminium strip from roof and wall of ESHs any size and position including making good to disrurbed surface of wall and roof complete all as specified and directed.
Refixing of serviceable aluminum strip 25x3 mm complete as obtain from above item 7 with on new saddle / insulators, including straightning and fixing screws/accessories for roof and down conductor complete all as specified and directed. Note: 1.Fixing of serviceable insulators will be deemed to be included with quotade rate. 2. Rate of new insulators shall be deemed included in quated rate .
S&F aluminium strip of size 25x3 mm complete with insulator/saddle and fixing with screw/accessories for roof and down conductor complete all as specified and directed. Note: Rate of insulators shall be deemed included in quated rate .
Taking down old Unserviceable GI strip from wall or buried in ground or any other indicated situation including making good to disrurbed surface complete all as specified and directed.
Refixing of serviceable GI Strip 32x6mm as obtain from above item 11 fixed on wall or buried in ground or any other indicated situation complete all as specified and directed.
S&F GI Strip 32x6mm fixed on wall or buried in ground or any other indicated situation complete all as specified and as directed Note:- Extra GI strip consider for borewell earthing which for existing earthing location
Taking down old Unserviceable air termination rod of any size and capacity complete all as specified and directed.
Refixing of serviceable Air termination rod as obatin from Item No 4 above including new threading and grinding of tip of air termination as per site requirnment complete all as specified and directed.
S&F single pointed air termination aluminium rod 12 mm dia and 300 mm long complete all as specified and directed.
M&L for Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw complete all as specified and directed.
Taking down old Unserviceable GI pipe of 40mm size complete all as specified and as directed.
S&F GI pipe light grade 40 mm dia for protection of GI strip complete all as specified and directed. (for strip protection)
S&F GI pipe medium grade 40 mm dia for protection of GI stripcomplete all as specified and directed. (For ACSR conductor pole)
S&F in replacement of old unserviseable porceiline insulator for conductor for 25 X 3/3.15 mm strip with one meter intervel secured with suitable screw complete all as specified and directed.
S&F in replacement of old unserviseable porceiline insulator for 32 X 6 mm strip with one meter intervel secured with suitable screw complete all as specified and directed.
Supplying and stringing Aluminium conductor, steel reinforced (ACSR) any type of ACSR conductor for airtermination points supported by GI tubing on the roof of the ESHs to inner connect the all termination points including taking down of existing conductor complete all as specified and directed. (Notes : (i) The ACSR conductors shall be conforming to IS-398 and as specified in SSR Part-I.(ii) The unit rate quoted shall also be deemed to include for supply & fixing of aluminium binding wire, aluminium tapes etc which shall not be included in the weight of conductors.(iii) Weight of conductors shall be determined by measuring true horizontal distance between centers of two adjacent poles and compounding the weight of conductors of that size and length and 3% extra added for sag, jointing, jumpers etc. (iv) Weight of the conductors shall be calculated from the nominal weights given in tables in the relevant IS.)
M & L for stay assembly to support GI pipe for Air Termination by providing 4mm dia GI wire 15 RM, 16mm MS Rod 1.35 RM and PCC block 1:3:6 size of 0.6x0.6x0.15M including earth work in sof soil including dismantling old Stay assembly complete all as specified and directed.
S&F in replacement Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint complete all as specified and directed.
Tulsi Enterprises (BID ID -3093333)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .