Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.2 LAccepted-AOC | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹12.1 L+₹3.9 L (48.1%)Rejected-Finance | L2 | Rejected-Finance Quoted other than lowest rate | |
| 3 | L3₹14.6 L+₹6.4 L (78.8%)Rejected-Finance GROUND FLOOR TRACTOR MARKET KAITHAL ROAD ASSANDH KARNAL HARYANA 132039 | KARNAL | HARYANA | 132039 | L3 | Rejected-Finance Quoted other than lowest rate | |
| 4 | L4₹16.5 L+₹8.3 L (102.2%)Rejected-Finance | L4 | Rejected-Finance Quoted other than lowest rate |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
4 Mar 2021, 6:00 pmClosed
Shri Sachin H Chavan IDSE
Garrison Engineer (North) Bathinda Mil Stn
MAINT/REPAIR TO CEILING FAN AND OTHER FANS UNDER GE NORTH BATHINDA AT BATHINDA MIL STN
2021_MES_419811_1
8935/NIT-56/20-21
Open Tender
Electrical and Maintenance Works
Item Rate
184 days
GE North Bathinda Mil Stn
Class E
9 documents required · 9 mandatory
₹500
GE (North) Bathinda
₹50,000
Yes
10 Mar 2021
6 Feb 2021
6 Mar 2021
6 Feb 2021
4 Mar 2021
20 Feb 2021
6 Feb 2021 - 12 Feb 2021
Amount
Disconnecting electric connection and taking down carefully defective/unserviceable ceiling fan/exhaust fan/wall mounted fan/cabin fans/table fans etc ( of any size/make) from site as directed and deposit in AGE E/M Store yard complete all as specified and as directed by Engineer-in-charge. Note :- (i) The T & P/vehicles will be arranged by the contractor and the cost deemed to be included in the quoted unit rates.
Collecting serviceable/repaired ceiling fan and exhaust fans (any size/make) from E/M store yard and hanging/fixing at site as directed including electric connection with new flexible copper cable, including supply and fixing new mild steel clamp complete with rubber reel, GI nut bolts, split pin and lock washer (all heavy duty as per sample) for hanging of ceiling fan and nut bolts/steel fastners 10mm dia 100mm long for hanging of exhaust fan and screw, PVC gutties etc as per site requirement complete all as specified and as directed by Engineer-in-charge. Note : (i) Cost for new flexble cable (make: FINOLEX/ Polycab/HPL/Anchor/ PARAGON/ HAVELLS/Plaza), mild steel clamp, rubber reel, GI nut bolt, split pin, washer, steel fastners, screw, PVC gutties etc shall deemed to be included in the quoted unit rates nothing shall be paid extra on this account.
Collecting serviceable/repaired wall mounted fan / air circulator fan / cabin fans / pedestral fans / table fans etc (any size/make) from E/M store yard and hanging/fixing/deposit to users site as directed including electric connection with existing electric system including fixing material as required complete all as specified and as directed by Engineer-in-charge.
Material and labour for collecting unserviceable ceiling fan 1200mm sweep, single phase, any make/model from E/M store yard of GE(N) Bathinda, Dismantling the ceiling fan and taking out complete burnt winding, thoroughly cleaning the core and all other components of the fan, rewinding the motor with super enamelled Copper winding wire of suitable turn and gauge as per the original, using insulating material paper sleeves and varnish class ‘B’ for insulation, well drying, replacement of rusted /unserviceable nuts, bolts, machine screws etc including oiling/greasing and replacement of defective / unserviceable parts/spares i.e. ball bearing, gun metal bush as required, including any kind of repair work in shaft, reassembling the fan as per original and testing the fan on-load for two hours and deposting the complete repaired fan to E/M store yard of GE(N) Bathinda complete all as specified and as derected by Engineer-in-charge. Make for varnish : Dr Beck Insulating Varnish/HI-GRADE/LUREX/FINE FINISH/JYOTI Polyester Varnish/N S SHAH & Co.
All as per above Srl item No. 04 but for ceiling fan 1400mm sweep complete all as specified and as directed by Engineer-in-charge.
All as per above Srl item No. 04 but for exhaust fan 400/450mm sweep complete all as specified and as directed by Engineer-in-charge.
All as per above Srl item No. 04 but for exhaust fan 200 to 380mm sweep complete all as specified and as directed by Engineer-in-charge.
All as per above Srl item No. 04 but for air circulator any sweep complete all as specified and as directed by Engineer-in-charge.
All as per above Srl item No. 04 but for table fan or pedestal fan any sweep complete all as specified and as directed by Engineer-in-charge.
All as per above Srl item No. 04 but for wall mounting fan or cabin fan any sweep complete all as specified and as directed by Engineer-in-charge.
Note for item No.04 to 10 above :- (i) Copper winding wire and all defective/ unserviceable parts/items like bush, bearing, condenser shall be measured and paid separetaly under appropriate item of BOQ as supply only. (ii) Counting record of all supply only material issued to contractor as on required basis /demands by contractor for replacement shall be maintain properly on seprate register by concerned JE and counter signed by Engineer-in-charge monthly. (iii) The contractor will make arrangement for re-winding of fan at MES AGE E/M Store yard. The store/space for workshop will be provided by the department. (iv) MES No. of fan and GE (N) if missing, re-write the same as directed with sy-enamel paint and the cost deemed to be included in the quoted unit rates nothing shall be paid extra on this account. (v) The necessary winding machine/T & P/vehicles shall be arranged/brought by the contractor and the cost deemed to be included in the quoted unit rates nothing shall be paid extra on this account.
Supply only super enamelled Copper winding wire suitable for motor winding of ceiling fans/exhaust fans/wall mounted fan/cabin fans/pedestral fans/table fans etc complete all as specified and as derected by Engineer-in-charge. (Make for winding wire :- Devidyal/HTP Thulax/Chetak/Atlas
Material and labour for collecting unserviceable ceiling fan / exhaust fan and other fan any make/model from E/M store yard of GE(N) Bathinda for replacement of ball bearing and bush only (except winding ) , Dismantling the fan and taking out complete parts, thoroughly cleaning the all components, replacement of ball bearing, gun metal bush and minor parts i.e. sleevs, nuts, bolts, machine screws etc including oiling/greasing, reassembling the fan as per original and testing and deposting to E/M store yard of GE(N) Bathinda complete all as specified and as derected by Engineer-in-charge. Note : (i) Bush, bearing, condenser shall be measured and paid separetaly under appropriate item of BOQ as supply only (ii) Counting record of all supply only material issued to contractor as on required basis /demands by contractor for replacement shall be maintain properly on seprate register by concerned JE and counter signed by Engineer-in-charge monthly. (iii) MES No. of fan and GE (N) if missing, re-write the same as directed with sy-enamel paint and the cost deemed to be included in the quoted unit rates nothing shall be paid extra on this account.
Material and labour for lath work to any type of fan for taking out/cutting by machine bush/bearing from the body part of ceiling fan and replacing it with suitable size of ball bearing/bush as per matching size to shaft making necessary bearing boring, polishing of shaft Complete all as specified and as directed by Engineer-in-charge. Note : - Bearing/bush (supply only) shall be measured and paid separately under respective item of BOQ.
Supply only ball bearing suitable for ceiling fan / exhaust fan or any other fan (like bearing size / No 6201 / 6202 / 6203 etc or as per exisiting size and No) complete all as specified and as directed by Engineer-in- Charge. Make :- SKF/NBC/TATA/FAG/NSK
Supply only gun metal bush suitable for any type and sweep of fan complete all as specified and as directed by Engineer-in- Charge. Make :- SKF/NBC/TATA/FAG/NSK
Supply only dry capacitor/condenser of capacity 2.5 Mfd (ISI marked) complete all as specified and as directed by Engineer-in-charge. Make :- Tesla/Asian/Epcos/MTC/ Usha/ Siemens/Jyoti
Supply only capacitor/condenser of capacity 3.15/4.00/6 Mfd (ISI marked) complete all as specified and as directed by Engineer-in-charge. Make :- Tesla/Asian/Epcos/MTC/ Usha/ Siemens/Jyoti
Supply and fixing in replacement mild steel fan blade set suitable for ceiling fan of sweep 1200mm (any make/model) duly painted as per sample or as directed by Engineer-in-charge.
Supply and fixing in replacement mild steel fan blade set suitable for ceiling fan of sweep 1400mm (any make/model) duly painted as per sample or as directed by Engineer-in-charge.
Supply and fixing in replacement PVC canopy (top or bottom) suitable for suitable for ceiling fan of 1200 / 1400 mm sweep any make/model complete all as specified and as directed by Engineer-in-charge.
Supply and Fixing in replacement fan blade (mild steel) set suitable for exhaust fan of sweep 300 to 450mm (any make/model) duly painted, as per sample or as directed by Engineer-in-charge.
Supply and Fixing in replacement fan blade (mild steel) set suitable for exhaust fan of sweep 200 to 250mm (any make/model) duly painted, as per sample or as directed by Engineer-in-charge.
Supply and Fixing in replacement frame and louvers made out of GI sheet, size suitable for exhaust fan of sweep 200 to 250mm (any make/model), as per sample or as directed by Engineer-in-charge.
Supply and Fixing in replacement frame and louvers made out of GI sheet, size suitable for exhaust fan of sweep 300 to 450mm (any make/model), as per sample or as directed by Engineer-in-charge.
Supply and Fixing in replacement fan blade set (PVC) suitable for exhaust fan of sweep 200 to 250mm (any make /model) as per sample or as directed by Engineer-in-charge.
Supply and Fixing in replacement PVC frame and louver suitable for exhaust fan of sweep 200 to 250mm (any make /model), as per sample or as directed by Engineer-in-charge.
Supply and Fixing in replacement fan motor (ISI marked) suitable for PVC exhaust fan of sweep 200 to 250mm (any make /model), as per sample or as directed by Engineer-in-charge.
Disconnecting electric connection of ceiling fan (any size/make) at any site as per complaint given by JE for minor repair/lose connection/replacement of capacitor if required, replacement of connection wire if required, cleaning, replacement of nut bolts etc., and after that make the connection properly and testing the fan upto entire satisfaction of users complete all as specified and as directed by Engineer-in-charge. Note :- (i) Fan shall be repaired at site and shall not be taken away of user's permisses. Fan if required taking down/re hanging the cost for the same shall be included in the unit rate nothing shall be paid extra on this account. (ii) Connection wire if required (fan to connector/ceiling rose ) the cost for the same shall be included in the unit rate nothing shall be paid extra on this account. (iii) Capacitor if required (if burnt/unserviceable), the same shall be measured and paid separetaly under appropriate item of BOQ. Counting record of all supply only material issued to contractor as on required basis /demands by contractor for replacement shall be maintain properly on seprate register by concerned JE and counter signed by Engineer-in-charge monthly. (iv) MES No. of fan and GE (N) if missing, re-write the same as directed with sy-enamel paint and the cost deemed to be included in the quoted unit rates nothing shall be paid extra on this account.
Material and labour for painting to ceiling Fan of any sweep/size/make, checking nut bolts and replace if required, painting the fans (at store yard of AGE E/M or as per direction of Engineer-in-charge) complete including fan body, blades, canopies, down rod etc. with synthetic enamel paint by spray gun after scraping down old paint, cleaning all dust / spoil and greasy spots and including using filler for filling cavities, painting to fan in white/Black/Grey paint or as approved by Engineer-in-charge. After painting MES No and GE (N) shall be marked with red colour synthetic enamel paint using stencil as per existing alloted number complete all as specified and as directed by Engineer-in-charge.
Supply and fixing in replacement stepped type (1-4), electronic Fan regulator (one module), 100 watt, 250 volts, in existing switch board as per existing make and shape including making elctric connection and testing, including screw for fixing as required, fixing at any site as directed complete all as specified and as directed by Engineer-in-charge. Make :- ANCHOR/LEGRAND/PHILLIPS/HAVELLS
Supply and fixing in replacement stepped type (1-4), electronic Fan regulator (two module), 100 watt, 250 volts, in existing switch board as per existing make and shape including making elctric connection and testing, including screw for fixing as required, fixing at any site as directed complete all as specified and as directed by Engineer-in-charge. Make :- ANCHOR/LEGRAND/PHILLIPS/HAVELLS
Supply and fixing in replacement switch piano flush type, 5/6Amps, 250 volts, single pole, one wayin existing switch board as per existing make and shape including making elctric connection and testing, including screw for fixing as required, fixing at any site as directed complete all as specified and as directed by Engineer-in-charge. Make : ANCHOR/ SSK/ HAVELLS/ Vinay/ LEGRAND
Note:- (i) The penalty shall be applicable to the contractor if the delay is noticed to attend the complaints by the EIC. (ii) The contract sum shall be calculated by deducting the amount shown in Credit Schedule attached to this tender, from total amount of Schedule 'A'/BOQ
NASIB ENGINEERS AND CONSTRUCTION
swarn singh and co.
M/S SODHI ASSOCIATES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .