Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.7 LAccepted-Finance | L1 | Accepted-Finance L1 | |
| 2 | L2₹27.7 L+₹6.0 L (27.7%)Accepted-Finance | L2 | Accepted-Finance L2 | |
| 3 | L3₹29.7 L+₹8.0 L (37.0%)Accepted-Finance | L3 | Accepted-Finance L3 | |
| 4 | L4₹34.0 L+₹12.2 L (56.4%)Accepted-Finance | L4 | Accepted-Finance L4 | |
| 5 | L5₹64.5 L+₹42.8 L (197.0%)Accepted-Finance | L5 | Accepted-Finance L5 |
Tender Value
Refer Docs
EMD Value
₹65,000
Closing Date
23 Jul 2019, 3:00 pmClosed
The Director
CSIR-CLRI
Supply, Erection, Installation, Commissioning, Operation and Maintenance of Co-Digestion plant for Organic Fraction of Leftover Food Waste, Vegetable Peels and Fruit Peels for Biogas Generation from Hotel Industry on Turnkey Basis
2019_CSIR_27136_1
28(01)/2019/Pur
Open Tender
Miscellaneous Goods
Turn-key
180 days
CLRI Chennai
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
₹65,000
Yes
B.M Das Hall,
3 Jan 2020
8 Jun 2019
26 Jul 2019
8 Jun 2019
23 Jul 2019
20 Jun 2019
8 Jun 2019 - 13 Jun 2019
18 Jun 2019
Supply, Erection, Installation, Commissioning, Operation and Maintenance of Co-Digestion plant for Organic Fraction of Leftover Food Waste, Vegetable Peels and Fruit Peels for Biogas Generation from Hotel Industry on Turnkey Basis
Feed Preparation tank (with removable cover) of size 1.5mx1.5x1.2m (LD) + 0.3 m FB MoC: MS ( minimum 6 mm thickness with minimum FRP coating of 1 mm thickness) MS should satisfy IS 2602 code Suitable concrete foundation is to be provided
Anaerobic Digester (with Scum breaking mechanism), as per GA drawing, of size 3.6 Diameter x 3.6m LD +0.6 Gas space MoC: MS ( minimum 6 mm thickness with minimum FRP coating of 1 mm thickness) MS should satisfy IS 2602 code. Digester should be provided with Suitable concrete foundation
Gas Holder enclosure MoC: Epoxy coated MS frame with sheeting. Must be provided over Suitable concrete foundation
Digestate Collection tank ( with removable cover) of size 1.0 mx1.0 x1.2m (LD) + 0.3 m FB MoC: MS ( minimum 6 mm thickness with minimum FRP coating of 1 mm thickness) MS should satisfy IS 2602 code Suitable concrete foundation is to be provided
Supernatant Collection tank (with removable cover) of size 1.0 mx1.0 x1.2m (LD) + 0.3 m FB MoC : MS ( minimum 6 mm thickness with minimum FRP coating of 1 mm thickness) MS should satisfy IS 2602 code Suitable concrete foundation to be provided
Gas Flare MoC : SS 316
Gas Flare Platform and derrick structure- of Height: 6m above GL . To suit the gas flare MoC : Mild Steel platform with hand rails, safety and access arrangements, suitable support structure and concrete foundation should be provided.
Pump Pads- To suit the size of the pumps- Moc: concrete
Sorting Table- MoC : Sorting table shall be of MS with Epoxy and top surface shall be of SS
Shredder/ Mincer to Mince total waste of 500 kg/day. Minimum Capacity of Mincer required is : 250 kg/hr MoC shall be of: • Cutter Blades : Tool Hardened Steel • Impeller : Tool Hardened Steel • Teeth Ring : Tool Hardened Steel
Agitator- Feed Preparation Tank Type: Turbine MoC of Shaft and Propeller: SS 304 Motor HP: 1.5 Motor RPM: 1440
Agitator- Digestate Collection Tank Type: Turbine MoC : SS 304 Motor HP: 1.5 Motor RPM: 1440
Feed Pumps To feed from Feed Preparation tank to Digester Type of Pump: Submersible Pumps Capacity: 2 m3/hr Head requirement: 8 m Qty - 2 (1W+ 1S)
Digestate Withdrawal pumps Type of Pump: Centrifugal Pumps Capacity: 1m3/hr Head requirement: 5 m Qty - 2 (1W+1S)
Chamber Filter press with filter feed pumps and other accessories
Gas balloon for collection of biogas of capacity 50 m3 MoC : Polyamide 1670 dtx; Weight in g/m2 1350
Gas burner Assembly with necessary piping for connection to the Kitchen for utilization of biogas
Biogas Flaring System with safety arrangements
Pressure Gauges
Pressure Relief Valves
Gas Flow Meter range required: 15 to 25 liters/min
Piping and Valves
Electrical Works: including provision of power feeding panels, distribution boards, UG cables, motor starters, etc., with required cabling, wiring and connections.
Trail runs, Commissioning and Stabilization Period (3 months)
Operation and Maintenance (3 months)
XEON WASTE MANAGERS
Knowledge Integration Service India Pvt Ltd
B-SUSTAIN ENERGY PROJECTS PRIVATE LIMITED
Aruna Green Ventures Pvt Ltd
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .