Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance GRAM AEMANPUR DISTRICT BULANDSHAHR UTTAR PRADESH | BULANDSHAHR | BULANDSHAHR | UTTAR PRADESH | Admitted-Finance |
| 3 | Not Admitted-Fee/PreQual/Technical | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
| 4 | Not Admitted-Fee/PreQual/Technical | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
₹5.2 L
EMD Value
₹5,200
Closing Date
13 May 2020, 12:00 pmClosed
SE EUCC V LESA LUCKNOW
Lesa Bhawan Near Residency, Lucknow
Construction of 33 KV Bay at 33/11 KV S/S Sampurnanand Jail Road, Alambagh and 33/11 KV S/S R.P.H. for giving an additional source to 33/11 kv S/S Sampoornanand by interlinking 33 KV line in between R.P.H. S/S and Sampoornanand S/S
2020_MVVNL_462186_1
44/EUCC V/2019-20
Open Tender
Electrical Works
90 days
Sampoornanand S/S
As per tender documents
2 documents required · 2 mandatory
₹1,180
A/c. No.10101985364 IFSC CODE No. SBIN0003347 SBI
₹5,200
15 May 2020
24 Apr 2020
13 May 2020
24 Apr 2020
13 May 2020
24 Apr 2020
Amount
Dragging, loading, carriage and unloading of following store materials with proper stacking from ESC Daliganj to JE dumps store and from JE dump store to work site within municipal area.
Cost of 33 KV 3x300sqmm XLPE Cable
33 kv line Isolator
33 kv bus Isolator
33 kv CT 400/200/1A
33 kv VCB 800A
Control Pannel Single feeder
33 KV Jointing Kit 3x300 sq mm Cable Outdoor
33 kv lightining arrester
Panther Conductor
MS channel 100x50 mm
MS Channel 125x65mm 3.5m long 2 Nos. 7M @ 13.1 Kg. Mtr.
MS Angle 75x75x6 2.6M long 2 Nos. [email protected] Kg./M
MS Channel 125x65mm 3.5m long 4 Nos Pieces [email protected] Kg. Mtr. With wastage
Cutting shaping, laying and welding of riser GI strip of size 50x6 mm in between earth mat/boring type earthing and equipments/structure/body of T/F for earthing. Two nos Riser for each structure equipment individually (Required GI strip will be provided by contractor).
Construction of masonry type plinth for 33KV VCB of size 1.6x1.6x1 M brick, sand, cement and stone grit including grouting of 4 Nos foundation of bolts for erection of 33KV VCB.
Isolator Structure-Fabrication of Isolator structure minimum 3.5 mtr overall height and 2.5 mtr above ground level as per RESSPO drawing, with help of M.S channel 125x65 mm two pieces of M.S channel joined to each other by M.S flat 50x6 mm, diagonally at the interval of 0.5 mtr and top & bottom of the structure. Grouting of Isolator structure in CC (cement ,coarse sand and stone grit of 20 mm gauge) including supply of necessary T&P and painting of structure complete.(only M.S channel and angle provided by the deptt)
Fabrication of lightning arrestor/CT structure as per RESSPO drawing with the help of 2 nos M.S channel 125x65 mm minimum 3.5 mtr long grouting 1 mtr deep from ground level in cc in ratio 1:4:8. complete in all respect.
Painting of all structures equipment (new and existing).
Mounting of accessories/equipment on fabricated structure complete work with making proper alignment and tightening the work including fabrication work if required for proper operation of equipment
33 KV VCB
33 KV Current Transformer 400/200/1 A
33KV lightning Arrestors
Bus/Line Isolator
Dragging of following panels from unloading place upto control room and placement, erection, grouting, commissioning and testing of the same as per RESPO Norms
33 KV control pannel single feeder
Jumpering of complete line bay with ACSR panther Cond. with required clamp, nut & Bolts from 33 KV existing bus bar & 33 KV cable complete work.(1 no. line bay)(required PG clamps will be provided by contractor).
Laying of single circuit 33 KV 3x300 sq mm XLPE cable in normal soil in switch yard as per norms. Cable trench should filled by fine sand.
Making heat & shrinkables joints of following sizes and types (Jointing kit will be provided by deptt.)
Outdoor Jointing kit for 33 KV, 3x300 sqmm XLPE cable
Hoisting, jumpering, clamping of 33 KV 3x300 sq mm XLPE cable on cable stand/structure with proper jumpering with help of PG clamps (required PG clamps will be provided by contractor).
Construction of cable trench of size 150 mm wide 300 mm deep with brick work along with provision trench cover M.S strip at the interval of 0.30 M and M.S angle at both the edge of the trench.
Construction and fixing of trench cover0.5 M wide 0.75 mm thick with cement, coarse sand & stone grit in ratio 1:2:4 for covering of cable trench150 mm wide with provision of M.S Angle and MS Bar as per RESPO Norms
Laying of copper control cable of following sizes its proper dressing, ferruling and connection with the system (cable will be provided by contractor).
2x2.5 sq mm
4x2.5 sq mm
6x2.5 sq mm
Pipe boring type earthing minimum 20 mtr deep from ground level or upto water level with B class G.I. pipe 2 " dia. Connection of equipment with earthing included in the job as per specification/norms for CT/LA and other.
High pressure testing of cable
ARIHANT ELECTRIC COMPANY
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid