Tender Value
₹3.1 Cr
EMD Value
₹6.3 L
Closing Date
25 Aug 2026, 3:00 pmDue tomorrow
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
65 days
Expenditure
Capital (Works)
Above/Below/Par
SIGNAL
15 conditions · 2 needing a document upload
The tenderer must have minimum average annual contractual turnover of V/N or 'V' whichever is less; where V= Advertised value of the tender in crores of Rupees N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure-VIB, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet.
The tenderer must have successfully completed or substantially completed any one of the following categories of work(s) during last 07 (seven) years, ending last day of month previous to the one in which tender is invited: (i) Three similar works each costing not less than the amount equal to 30% of advertised value of the tender, or (ii) Two similar works each costing not less than the amount equal to 40% of advertised value of the tender, or (iii) One similar work costing not less than the amount equal to 60% of advertised value of the tender.
Work experience certificate from private individual shall not be considered. However, in addition to work experience certificates issued by any Govt. Organisation, work experience certificate issued by Public listed company having average annual turnover of Rs 500 crore and above in last 3 financial years excluding the current financial year, listed on National Stock Exchange or Bombay Stock Exchange, incorporated/registered at least 5 years prior to the date of opening of tender, shall also be considered provided the work experience certificate has been issued by a person authorized by the Public listed company to issue such certificates. In case tenderer submits work experience certificate issued by public listed company, the tenderer shall also submit along with work experience certificate, the relevant copy of work order, bill of quantities, bill wise details of payment received duly certified by Chartered Accountant, TDS certificates for all payments received and copy of final/last bill paid by company in support of above work experience certificate.
Defination of Similar Work :- Signalling works of RRI or PI or EI indoor works with or without outdoor works with supply of EI or relay and other signalling equipment. Special condition:- The successful bidder shall submit an undertaking from RDSO approved El OEM (i.e Siemens Rail Automation Pvt. Ltd), before the supply of material, to confirm compliance with extant RDSO guidelines and to meet contract specific requirements.
42 conditions · 5 needing a document upload
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
GST Registration details should be attached
Tenderers will examine the various provisions of The Central Goods and Services Tax Act, 2017(CGST)/ Integrated Goods and Services Tax Act, 2017(IGST)/ Union Territory Goods and Services Tax Act, 2017(UTGST)/ respective state's State Goods and Services Tax Act (SGST) also, as notified by Central/State Govt & as amended from time to time and applicable taxes before bidding. Tenderers will ensure that full benefit of Input Tax Credit (ITC) likely to be availed by them is duly considered while quoting rates.
The successful tenderer who is liable to be registered under GST/IGST/ UTGST/SGST Act shall submit GSTIN along with other details required under CGST/IGST/ UTGST/ SGST Act to railway immediately after the award of contract, without which no payment shall be released to the contractor. The contractor shall be responsible for deposition of applicable GST to the concerned authority.
In case the successful tenderer is not liable to be registered under GST/IGST/UTGST/ SGST Act, the railway shall deduct the applicable GST from his/their bills under reverse charge mechanism (RCM) and deposit the same to the concerned authority.
Every tenderer shall state in the tender his postal address fully and clearly. Any communication sent in time to the tenderer by post at the said address shall be deemed to have reached the tender duly and in time. Important documents shall be sent by Registered post.
The provision of Construction and Demolition Waste Management Rule 2016 issued by Ministry of Environment Forest and Climate Change dated 29.03.2016 and published in the Gazette of India, Part - II, Section -3, Subsection (ii) are binding upon the Contractor. Contractor shall implement these provisions at worksites, for which no extra payment will be payable.
Before submitting a tender, the tenderer will be deemed to have satisfied himself by actual inspection of the site and locality of the works, that all conditions liable to be encountered during the execution of the works are taken into account and that the rates he enters in the tender forms are adequate and all inclusive to accord with the provisions in Clause-37 of the Standard General Conditions of Contract for the completion of works to the entire satisfaction of the Engineer
The Railway reserves the right to verify all statements, information and documents submitted by the bidder in his tender offer, and the bidder shall, when so required by the Railway, make available all such information, evidence and documents as may be necessary for such verification. Any such verification or lack of such verification, by the railway shall not relieve the bidder of its obligations or liabilities hereunder nor will it affect any rights of the railway there under.
The following documents should be submitted by the tenderer on issue of LOA and before signing Contract Agreement:-.
The documents pertaining to Deployment of Qualified Engineers at Work Sites by the Contractor.
EPF & ESI Registration certificate should be submitted before signing of Contract Agreement.
Price variation clause (PVC) shall be applicable only in tender having advertised value above Rs. 2 crore provided further that, in a tender document PVC is applicable.
All the Terms and Conditions in this contract is as per Indian Railways Standard General Conditions of Contract updated with correction slips issued up to date of inviting tender or as otherwise specified in the tender documents
If the tenderer(s) expire(s) after the submission of his / their tender or after the acceptance of his / their offer, the Railway shall deem such tender cancelled. If a partner of a firm expires after the submission of their tender or after the acceptance of their tender, the Railway shall deem such tender as cancelled, unless the firm retains its character.
Contractor is to abide by the provisions of Payment of Wages act & Minimum Wages act in terms of clause 54 and 55 of Indian Railways General Condition of Contract. In order to ensure the same, an application has been developed and hosted on website 'www.shramikkalyan.indianrailways. gov. in'. Contractor shall register his firm/company etc. and upload requisite details of labour and their payment in this portal. These details shall be available in public domain. The Registration / updation of Portal shall be done as under:-
Contractor shall apply for onetime registration of his company/firm etc. in the Shramikkalyan portal with requisite details subsequent to issue of Letter of Acceptance. Engineer shall approve the contractor's registration in the portal within 7 days of receipt of such request.
Contractor once approved by any Engineer, can create password with login ID(PAN No.) for subsequent use of portal for all Letter of Acceptances (LoAs) issued in his favour.
The contractor once registered on the portal, shall provide details of his Letter of Acceptances (LoAs) / Contract Agreements on shramikkalyan portal within 15 days of issue of any LoA for approval of concerned Engineer. Engineer shall update (if required) and approve the details of LoA filled by contractor within 7 days of receipt of such request.
After approval of LoA by Engineer, contractor shall fill the salient details of contract labours engaged in the contract and ensure updating of each wage payment to them on shramikkalyan portal on monthly basis.
It shall be mandatory upon the contractor to ensure correct and prompt uploading of all salient details of engaged contractual labour & payments made thereof after each wage period.
While processing payment of any 'On Account Bill' or 'Final Bill' or release of 'Advances' or 'Performance Guarantee / Security deposit', contractor shall submit a certificate to the Engineer or Engineer's representatives that "I have uploaded the correct details of contract labours engaged in connection with this contract and payments made to them during the wage period in Railway's Shramikkalyan portal at 'www.shramikkalyan. indianrailways.gov.in' till Month, Year."
Associate signalling works in connection with provision of Track Machine Siding at KTX, JMRA, LLBR, SIBR, HLX, BHRB & JRBM station of Lumding Division.
SNT-25-LMG-2026-27~NFR
SNT-25-LMG-2026-27
Open
Works - General
365 Days
Hojai, Assam
₹0
₹6.3 L
3 Aug 2026
3 Aug 2026
11 Aug 2026
306 items across 2 schedules
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 2,06,92,681.31 | ||
| — | 6.00 | — | — | ||
| Electric point machine (Rotary Locking Type) as per IRS-S: IRS:S 24-2025 (Revision 3.0) or latest 110V DC, 143 mm stroke as per TS | — | — | — | 6,46,798.02 | |
| — | 6.00 | — | — | ||
| Ground connections complete set for Point Machines as per TS. | — | — | — | 54,729.12 | |
| — | 6.00 | — | — | ||
| P o i n t machine ground connection insulation complete set as per technical specification. | — | — | — | 5,024.76 | |
| — | 6.00 | — | — | ||
| Gauge Tie Plate (GTP) insulation complete set as per technical specification. | — | — | — | 2,266.92 | |
| — | 6.00 | — | — | ||
| Point's william stretcher bar insulation complete set as per technical specification. | — | — | — | 794.22 | |
| — | 5.00 | — | — | ||
| Key Lock Checking Relay working on 24V DC Neutral Relay (AC Immunised) along with 1 Key & 3 ward plates (Shape A to Z, each shape 1 KLCR), contact configuration 4F/4B, metal to metal as per RDSO specification No. RDSO/SPN/219/2016 (Ver.1.0) or latest and conforming to firm specification TMA 1144/116 IM-OLO . | — | — | — | 41,065.5 | |
| — | 5.00 | — | — | ||
| Siemens Point Contactor Unit with base plates and connectors working on 24 V DC conforming to IRS: S-46 and Drg No.RS SK 21/0001B or latest. | — | — | — | 1,67,829.75 | |
| — | 2.00 | — | — | ||
| Supply of Relay Pug in type style QL1 magnetically latched, neutral line 24 V DC 11F/4B contact, front and back contact metal to carbon complete with plug board, retaiing clip and connectors conforming to BRS 935A, IRS:S:23 (As Applicable) | — | — | — | 12,626 | |
| — | 3.00 | — | — | ||
| Supply of Relay AC immunised plug in type style QBCA1 DC based point contractor 24 V 2F (HD), 4B contacts metal to carbon complete with plug board, retaining clip and connectors conforming to BRS:943, IRS:S:34 & IRS:S:23 (As Applicable) | — | — | — | 17,696.46 | |
| — | 10.00 | — | — | ||
| AC Immune Plug-in-type QSPA1, DC slow to pick up, Neutral Line relay 24V DC, 8F-4B contacts, front and back contacts metal to carbon with plug board, retaining clip and connectors conforming to BRS:933A with interlocking pin code ABDEJ. | — | — | — | 61,028.7 | |
| — | 15.00 | — | — | ||
| AC Immune Plug-in-type QNA1, DC Neutral Line relay 24V DC, 8F-8B contacts, front and back contacts metal to carbon with plug board, retaining clip and connectors conforming to BRS:931A with interlocking pin code ABDGH. | — | — | — | 79,292.25 | |
| — | 15.00 | — | — | ||
| AC Immune Plug-in-type QNA1, DC Neutral Line relay 24V DC, 12F-4B contacts, front and back contacts metal to carbon with plug board, retaining clip and connectors conforming to BRS:931A with interlocking pin code ABDFH. | — | — | — | 79,292.25 | |
| — | 10.00 | — | — | ||
| Relay ACI, Plug-in-type, Style QTA2, Neutral Track, 9 ohms, 2F/1B , conforming to BRS: 939A & 966 (Appendix F2) IRS:S 34 & IRS:S 23 as applicable (interlocking pin code FGHKX). | — | — | — | 45,303.3 | |
| — | 400.00 | — | — | ||
| Disconnect Terminal block for 4 (four) conductor (2 IN & 2 OUT) screw less with tin plated knife edge type disconnect link as per RDSO Specification No. RDSO/SPN/189/2004 version 3.0, each conductor size up to 2.5 sq mm (with or without lug) 16 Amp rated current and each block shall be equipped with two markers on top and bottom, an end plate for each block, 2 end clamps & adequate length rails for fitting terminal blocks. | — | — | — | 51,476 | |
| — | 5.00 | — | — | ||
| Shunt signal position light post as per specification No. IRS:S-6/81, complete with bracket, Post as per IRS-S-6 of 1981 having 4.5mm thickness & minimum 1m length, surface base, etc. | — | — | — | 1,45,460.6 | |
| — | 5.00 | — | — | ||
| Shunt signal position light unit non metalic complete as per RDSO Specification RDSO/SPN/194/2006 or latest consisting of signal unit, bracket, terminals etc. but without lenses, lamps and lamp holders | — | — | — | 1,05,735.3 | |
| — | 5.00 | — | — | ||
| Off set bracket for colour light signal with fixing U clamps & nuts etc (Shunt /Co-On) | — | — | — | 6,292.5 | |
| — | 10.00 | — | — | ||
| Automatic change over system of Track Feed battery Charger model No. BE-TFBC or similar as per TS | — | — | — | 69,224.5 | |
| — | 15.00 | — | — | ||
| Battery charger -Track Feed self mounting type (10 Amp) as per Specn. No.IRS:S- 89/2013 (Ver.1) or with latest amendment/specification. | — | — | — | 1,07,323.95 | |
| — | 30.00 | — | — | ||
| Secondary cells - Low Maintenance 2V/80 AH as per specification no. IRS: S-88/2004 or latest complete with inter cell connectors, nuts & bolts with washer, micro porous vent-cum- sealed float guide etc. | — | — | — | 1,17,934.2 | |
| — | 15.00 | — | — | ||
| TRACK FEED RESISTANCE - (Porcelain Base), 30 Ohm as per Drg. No.SA-20161-66/M or latest. | — | — | — | 4,816.5 | |
| — | 20.00 | — | — | ||
| Choke Coil for Single Rail Track Circuit on 25 KA 50 Hz AC Electrified Section as per specification No. IRS-S-65/83 (Amd.3) or latest | — | — | — | 1,09,574.4 | |
| — | 1.00 | — | — | ||
| PVC insulated Rly Signalling Indoor cables of size 60 core x 0.6 mm as per IRS(S) 76/89 (amendment 3) or with latest amendment as per technical specification. | — | — | — | 2,28,595.94 | |
| — | 5.00 | — | — | ||
| 16/0.2 mm dia (0.5 sqmm) multistrand tinned single core indoor wire as per IRS : S- 76/89 Amend. No. 3 or with latest amendment/specification, PVC coated in different colours. (1 Box= 1 Coil of 100 mtr) | — | — | — | 3,881.35 | |
| — | 5.00 | — | — | ||
| 32/0.2 mm (1.0 sqmm) PVC insulated unsheathed single core bright annealed bare copper conductor flexible cables for voltage grade upto 1100V conforming to IS:694/1990 or latest in different colour appended in technical specification and to be supplied in 100 meters coil. (1 Box= 1 Coil of 100 mtr) | — | — | — | 7,370.9 | |
| — | 4.00 | — | — | ||
| 2.5 sqmm ( 36/0.30 mm dia ) PVC insulated unsheathed single core bright annealed bare copper conductor flexible cables for voltage grade upto 1100 v conforming to IS:694/1990 as per TS. (1 Box= 1 Coil of 100 mtr) | — | — | — | 9,730.64 | |
| — | 3.00 | — | — | ||
| 84/0.3 mm (6.0 sqmm) PVC insulated unsheathed single core bright annealed bare copper conductor flexible cables for voltage grade upto 1100 V conforming to IS:694/1990 as per technical specification and to be supplied in coils of 100 meters. (1 Box= 1 Coil of 100 mtr) | — | — | — | 24,184.44 | |
| — | 2.00 | — | — | ||
| 140/0.3 mm (10.0 sqmm) PVC insulated unsheathed single core bright annealed bare copper conductor flexible cables for voltage grade upto 1100 v conforming to IS:694/1990 as per technical specification and to be supplied in coils of 100 meters. (1 Box= 1 Coil of 100 mtr) | — | — | — | 27,285.84 | |
| — | 200.00 | — | — | ||
| 226/0.3 mm (16 sqmm) PVC insulated unsheathed single core bright annealed bare copper conductor flexible cables for voltage grade upto 1100 v conforming to IS:694/1990 as per technical specification and to be supplied in coils of 100 meters. | — | — | — | 37,792 | |
| — | 1.00 | — | — | ||
| 354/0.3 mm (25 sqmm) PVC insulated unsheathed single core bright annealed bare copper conductor flexible cables for voltage grade upto 1100 V conforming to IS:694/1990 as per technical specification and to be supplied in coils of 100 meters. (1 Box= 1 Coil of 100 mtr) | — | — | — | 33,696.4 | |
| — | 1.00 | — | — | ||
| 495/0.3 (35 sqmm) PVC insulated unsheathed single core bright annealed bare copper conductor flexible cables for voltage grade upto 1100 V conforming to IS:694/1990 as per technical specification and to be supplied in coils of 100 meters. (1 Box= 1 Coil of 100 mtr) | — | — | — | 47,103.55 | |
| — | 15.00 | — | — | ||
| Track lead junction Box as per Drg. No.RST-11509 made of FRP materials conforming to RDSO/SPN/151/97 or latest complete with terminal blocks & links along with FRP Stump for mounting FRP assembly made of FRP Angle 30 x 30 x 4 mm - 1 mtr long (2 Nos) & 12 inch long (1 No.) along with Hardware as per TS. | — | — | — | 30,522 | |
| — | 100.00 | — | — | ||
| Double walled corrugated (DWC) HDPE duct (Pipe) of size 90 mm / 67 mm (min), standard length 6 mtr ± 1% each as per RDSO specification No. RDSO/SPN/204/2011/Version: 1.1 or with latest amendment, detail as per technical specification. | — | — | — | 26,448 | |
| — | 5.00 | — | — | ||
| Supply of Apparatus Case (Large) as per RDSO Drg. No.RDSO/S-11500 or latest fitted with key lock (E-Type) with Key of ward No.11 conforming to specification IRS:S/30 and Drg. No. S 3376/M & S 3377/M or latest. | — | — | — | 99,493.1 | |
| — | 5.00 | — | — | ||
| Hylam sheet 10 mm thick (Grade-P3) of size 1.22 m x 1.22 m as per IS 2036 of 1974 or latest. | — | — | — | 21,130.85 | |
| — | 26.00 | — | — | ||
| Under Ground Railway Signalling cable 12 core x 1.5 sq. mm Copper Conductor PVC insulated Armoured Unscreened, Under Ground cable to spec. no. IRS:S-63/2014 (Rev.4) or latest | — | — | — | 61,05,320 | |
| — | 2.00 | — | — | ||
| Underground Railway Signalling cable 2 core 2.5 sq. mm Copper Conductor PVC insulated, Armoured, Unscreened, as per spec. no. IRS:S-63/2014 (Rev.4) or latest | — | — | — | 2,74,940 | |
| — | 15.00 | — | — | ||
| Shunt LED signal lighting unit , 110V AC, retrofittable in existing CLS housing and compatible with AC LED ECR as per RDSO specification No. RDSO/SPN/153/2011 Rev.4.1(Draft) or latest | — | — | — | 95,580 | |
| — | 8.00 | — | — | ||
| Universal Plug-in-type AC Lamp Proving Relay 110V AC, Metal to Carbon contact 4F.4B, style QECX as per specification No. BRS:941A & STS/E/Relays/AC Lit LED signal/09-2002 Amdt.1 or latest with plug board, retaining clip interlocking pin code ABDHK. | — | — | — | 51,920 | |
| — | 4.00 | — | — | ||
| Supply pad locks (NAV TAL) Godrej , 65 mm 7 levers - long shackle (2 keys) as per product code 3290, Bann code LKYLPN662 or latest all with common keys. | — | — | — | 2,737.6 | |
| — | 5.00 | — | — | ||
| Design, preparation and supply of modified Circuits like SIP, PD, RCC, CTR particulars etc as per TS. | — | — | — | 12,50,000 | |
| — | 5.00 | — | — | ||
| Installation of Electric Point Machine including supply of G.I. Pipe, termination of cable, wiring and adjustment as per technical specification. | — | — | — | 57,955.9 | |
| — | 15.00 | — | — | ||
| Installation of TLJB as per TS | — | — | — | 3,361.5 | |
| — | 3538.00 | — | — | ||
| Excavation of trench 1.2 mtr deep, 0.3 mtr wide at the bottom along railway track in all type of soils (except rocky area), including clearing of bushes, trees, temporary obstruction, bailing out water from the trench etc. and refilling of the trench by excavated soil and ramming after laying of the required quantity of cables as per instruction of Engineer at site. | — | — | — | 2,47,836.9 | |
| — | 1000.00 | — | — | ||
| Digging of 1.00 Meter deep and 0.3 Meter wide trenches including clearing of roots of trees and bushes and temporary obstruction on rocky/ballast filled soil/Road crossing/track crossing/platform crossing as per technical specifications. | — | — | — | 5,58,490 | |
| — | 1100.00 | — | — | ||
| Execution of HDD boring as pe TS | — | — | — | 15,37,767 | |
| — | 28000.00 | — | — | ||
| Laying of Signalling Cables of various cores/pairs in trnch/GI /RCC /DWC HDPE pipes/trunking as per Technical specifications. | — | — | — | 1,33,840 | |
| — | 5.00 | — | — | ||
| Excavation, ramming, casting cement concrete foundation for position light shunt signal post in the ratio of 1:3:6 aggregate not exceeding 3:8 cm, as per Drg. No. CSTE/CON/SK/06/99 and technical specifications using standard size galvanized anchor bolts & nuts ( also referred to as foundation bolts) conforming to IRS Drg. no. SA-116A/M, for erection of colour light signal post, plastering with 1:4 cement-sand mixture all the surfaces up to 75 mm below ground level, complete with contractor's materials including cement, sand aggregate anchor bolts and nuts and curing of casted foundation, refilling & ramming of loose siol around foundation and disposal of loose dugged soil from site. | — | — | — | 21,627.75 | |
| — | 5.00 | — | — | ||
| Assembling, errection, installation of Independent Shunt signal taking of cable inside unit through post, termination and wiring of Colour light shunt signal complete with all accessories of shunt signal unit, post, base, hoods including fixing & wiring of LED units lamps with contractor's wiring material. | — | — | — | 18,534.9 | |
| — | 15.00 | — | — | ||
| Installation of earth electrode (pipe) as per technical specification. All required materials (3 meters long perforated G.I. pipe 50mm dia, charcoal, normal salt, earthing lead, nut & bolts etc. to be supplied by contractor). | — | — | — | 17,601.9 | |
| — | 5.00 | — | — | ||
| Cement concrete work for miscellaneous items in the ratio 1 : 3 : 6, aggregate not exceeding 3 : 8 cm including excavation,raming, curing and plastering with 1 : 4 cement - sand mixture complete with contractor's material including cement, sand, aggregate and curing of casted foundation, refilling & ramming of loose soil around foundation and disposal of loose dugged soil from site. | — | — | — | 15,740.2 | |
| — | 10.00 | — | — | ||
| Taking the all types of cables inside station relay rooms, location hut at both end and sealing of cable entry pit etc. as per Technical specifications, complete with contractors's material. | — | — | — | 81,181.1 | |
| — | 5.00 | — | — | ||
| Supply, installation of wooden crank handle lock up box for fixing of EKT/KLCR on wooden board inside box for installing KLCR/EKTs in the same including supply of all materials like board , handle, hinges, godrej type pad lock glass sheet of 5 mm thickness / supporting bracket, nuts, bolts etc , drilling holes in MS angles, MS plates etc for fixing relays/EKT/KLCR and its wiring in ASM room as per TS. | — | — | — | 16,754.6 | |
| — | 5.00 | — | — | ||
| Installation & wiring of key locked rotary relay (KLCR) inside box in ASM room as per TS | — | — | — | 7,691.45 | |
| — | 200.00 | — | — | ||
| Digital signal wiring of dataloggers between relay to intermediate tag block and intermediate tag block to datalogger tag block in Relay room including supply of 16/0.2 mm dia hook up wires as per IRS:S-76/89 (Amd.3) or latest. The work shall be done as per technical specification. (Nos.= Nos of input) | — | — | — | 51,194 | |
| — | Breakup | for details. | — | ||
| Excavation, ramming, Casting Cement Concrete foundation for Apparatus cases/Location boxes in the ratio of 1:3:6 Aggregate not exceeding 3 : 8 cm, as per Drg. No. CSTE's Drg. No. SK/12/00021 and technical specifications using standard size galvanized Anchor bolts & nuts also referred to as foundation bolts conforming to IRS Drg No. SA-116 A/M for erection of apparatus case/location box , plastering with 1:4 cement sand mixture all the surface up to 75 mm below ground level complete with contractor's materials including cement , sand, stone, anchor bolts/nuts and curing of casted foundation, refilling and ramming of loose soil around foundation and disposal of digged soil from site. | — | — | — | 24,690.5 | |
| — | Breakup | for details. | — | ||
| Installation of Apparataus cases/Location Boxes on CC foundation on grouted bolts, including filling the space enclosed below the location box with contractor's sand, as per technical specifications. | — | — | — | 7,407.15 | |
| — | Breakup | for details. | — | ||
| Termination of cables including fixing of hylam sheet and supporting on string rod, with supply and providing identification tags/ferrules/tapes with letters on each cable conductor, as per technical specifications. | — | — | — | 7,407.15 | |
| — | 10.00 | — | — | ||
| Installation & wiring of Track Relay (TR) as per technical specification. | — | — | — | 2,392.3 | |
| — | 5.00 | — | — | ||
| Validation, testing and networkinging of data loggers with additional inputs as per echnical specification. | — | — | — | 96,786.3 | |
| — | Breakup | for details. | — | ||
| Charging of secondary cells with contractor's own charging equipments including supply of sulphuric acid conforming to IS:266-1977, distilled water conformiong to IS:1069-1964, all activities as per technical specification and according to standard adopted for initial charging and installation of charged batteries as per instruction of Engineer at site. | — | — | — | 6,040.2 | |
| — | Breakup | for details. | — | ||
| Installation and commissioning of DC track circuits including drilling of bond holes, supply and fixing of continuity GI wire bonds on rail joints after drilling bond-hole of 7.2 mm dia (9/32"), channel pin & making rail connections of lead wires, installation & fixing of track lead junction box on MS angle grouted on concrete and cable taken through DWC Pipe for track feed end, track relay end and feed end Jumpers, connections to tail cable, termination of tail cables on TLJB terminals etc., insertion of insulated block joints and also fixing jumper cables as per insulation diagram/track bonding plan, charging & adjustment of track circuit, all activities as per standard practice and technical specifications. | — | — | — | 68,558.1 | |
| — | 10.00 | — | — | ||
| Installation, wiring, testing & commissioning of the Automatic change over system as per TS | — | — | — | 980.7 | |
| — | 10.00 | — | — | ||
| Supply and Installation of Signal number Plates as per Technical Specification. | — | — | — | 8,992.8 | |
| — | 3.00 | — | — | ||
| Modification in design of Electronic Interlocking system at station as per TS. | — | — | — | 19,50,000 | |
| — | 3.00 | — | — | ||
| Alteration in wiring, installation, testing and commissioning of EI at stations as per TS. | — | — | — | 13,50,000 | |
| — | 3.00 | — | — | ||
| Activity of FAT as per TS | — | — | — | 6,90,000 | |
| — | 3.00 | — | — | ||
| Supply of As Made document as per TS | — | — | — | 2,25,000 | |
| — | 3.00 | — | — | ||
| Activity of SAT as per TS | — | — | — | 7,82,775 | |
| — | 3.00 | — | — | ||
| Supply of additional wiring materials | — | — | — | 1,91,700 | |
| — | 1.00 | — | — | ||
| Portable report monitoring device for central location to monitor the progress of the work from HQ as per TS | — | — | — | 58,573.94 | |
| — | 1.00 | — | — | ||
| Network Communication Switch Suitable for Siemens Electronic Interlocking system as per RDSO Specification RDSO/SPN/192/2019 | — | — | — | 1,64,290.7 | |
| — | 1.00 | — | — | ||
| Embedded Operator's Console (1 Nos. Embedded PC with 2 nos 55" VDU as per TS. | — | — | — | 4,72,435 | |
| — | 1.00 | — | — | ||
| — | Breakup | for details. | — | ||
| — | 2.00 | — | — | ||
| — | 2.00 | — | — | ||
| — | — | — | 1,95,750.46 | ||
| — | 2.00 | — | — | ||
| — | — | — | 5,12,304.94 | ||
| — | — | — | 1,07,96,278.36 | ||
| — | 2.00 | — | — | ||
| Electric point machine (Rotary Locking Type) as per IRS-S: IRS:S 24-2025 (Revision 3.0) or latest 110V DC, 143 mm stroke as per TS | — | — | — | 2,15,599.34 | |
| — | 2.00 | — | — | ||
| Ground connections complete set for Point Machines as per TS. | — | — | — | 18,243.04 | |
| — | 3.00 | — | — | ||
| P o i n t machine ground connection insulation complete set as per technical specification. | — | — | — | 2,512.38 | |
| — | 3.00 | — | — | ||
| Gauge Tie Plate (GTP) insulation complete set as per technical specification. | — | — | — | 1,133.46 | |
| — | 4.00 | — | — | ||
| Point's william stretcher bar insulation complete set as per technical specification. | — | — | — | 529.48 | |
| — | 2.00 | — | — | ||
| Key Lock Checking Relay working on 24V DC Neutral Relay (AC Immunised) along with 1 Key & 3 ward plates (Shape A to Z, each shape 1 KLCR), contact configuration 4F/4B, metal to metal as per RDSO specification No. RDSO/SPN/219/2016 (Ver.1.0) or latest and conforming to firm specification TMA 1144/116 IM-OLO . | — | — | — | 16,426.2 | |
| — | 2.00 | — | — | ||
| Siemens Point Contactor Unit with base plates and connectors working on 24 V DC conforming to IRS: S-46 and Drg No.RS SK 21/0001B or latest. | — | — | — | 67,131.9 | |
| — | 2.00 | — | — | ||
| Supply of Relay Pug in type style QL1 magnetically latched, neutral line 24 V DC 11F/4B contact, front and back contact metal to carbon complete with plug board, retaiing clip and connectors conforming to BRS 935A, IRS:S:23 (As Applicable) | — | — | — | 12,626 | |
| — | 2.00 | — | — | ||
| Supply of Relay AC immunised plug in type style QBCA1 DC based point contractor 24 V 2F (HD), 4B contacts metal to carbon complete with plug board, retaining clip and connectors conforming to BRS:943, IRS:S:34 & IRS:S:23 (As Applicable) | — | — | — | 11,797.64 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
Tender Document
ATTACHMENT
BankGuaranteee-
ATTACHMENT
TenderDocumentSNT-25-LMG-2026-27TMSatBPBsection.pdf
ATTACHMENT
Acceptanceofe-BankGuaranteee-BGinWorksContracts.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].