Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.6 LAccepted-AOC | L1 | Accepted-AOC Accepted | |
| 2 | L2₹15.0 L+₹42,110 (2.89%)Rejected-AOC | L2 | Rejected-AOC Rejected | |
| 3 | Not Admitted-Fee/PreQual/Technical NO 354 2ND CROSS VARADARAJNAGAR VIDYARANYAPURA POST BANGALORE 5600 097 | 5600097 | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification | |
| 4 | Not Admitted-Fee/PreQual/Technical 15 5 1ST MAIN 2ND CROSS K S TOWN BANGALORE BANGALORE RURAL KARNATAKA 560060 | BENGALURU URBAN | KARNATAKA | 560060 | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification | |
| 5 | Not Admitted-Fee/PreQual/Technical 101 1ST FLOOR JASOL RESIDENCY 14TH CROSS KANAKANAGAR R T NAGAR POST BANGALORE 560032 | BANGALORE | BANGALORE | KARNATAKA | 560032 | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
Refer Docs
EMD Value
₹30,000
Closing Date
19 Nov 2020, 6:00 pmClosed
GE NORTH BANGALORE
GARRISON ENGINEER NORTH BANGALORE T 64 MEANEE LINES MEG AND CENTRE BANGALORE 560042
REPAIRS REPLACEMENT OF INTERNAL WIRING ELECTRICAL FITTINGS FIXTURES RENEWAL OF EARTHING AND REPAIRS TO ACs AT DGQA OFFICE COMPLEX AREA IN THE AOR OF AGE EM NORTH UNDER GE NORTH BANGALORE
2020_MES_389480_1
8480
Open Tender
Electrical and Maintenance Works
Item Rate
90 days
BANGALORE
Class E Category b(i) and c(i)
7 documents required · 7 mandatory
₹500
Yes
GARRISON ENGINEER NORTH BANGALORE
₹30,000
Yes
4 Dec 2020
24 Oct 2020
21 Nov 2020
24 Oct 2020
19 Nov 2020
7 Nov 2020
25 Oct 2020 - 6 Nov 2020
Amount
Taking down carefully aluminium/ copper wiring/power point wiring (light, fan,call bell socket or power circuits) complete and making good the disturbed surface of walls, ceiling etc including painting with same colour of the back ground complete all as specified and as directed by Engineer-in-Charge.
Point wiring complete with 1.5 sq.mm single core PVC insulated unsheathed cable 1100 volts grade multi stranded with FRLS copper conductor cable conforming to IS 694 drawn through and including PVC casing & caping ISI marked with all accessories surface type wiring including MS terminal boxes fabricated with 1.6 mm thick MS sheet concealed mounted / on walls with laminated sheet top cover 3 mm thick fixed with cadmium plated iron screws for housing the switches, switch socket outlets, fan regulators etc., including provision of 1.5 sq.mm PVC insulated single core multi stranded copper conductor cable as earth continuity conductor and connecting to common earth dolly, all as specified and as directed for :- (a) One light point controlled by one switch.
(b) One fan point controlled by one switch/regulator.
(c) One light point controlled by two 2 way switches.
(d) One 3 pin socket out let 5 Amps on independent board.
(e) one 3 pin socket out let 5 A on same board
All as per Sl Item No. 1.02 here in before but concealed wiring drawn through existing conduit for one light point controlled by one switch.
All as per Sl Item No. 1.07 here in before but one fan point controlled by one switch/regulator
All as per Sl Item No. 1.07 here in before but one light point controlled by 2 way switch.
All as per Sl Item No. 1.07 here in before but one 3 pin socket out let 5 Amps on independent board.
All as per Sl Item No. 1.07 here in before but one 3 pin socket out let 5 Amps on same board.
Point wiring complete with 2.5 sq.mm single core PVC insulated unsheathed cable 1100 volts grade multi stranded with FRLS copper conductor cabe conforming to IS 694 drawn through and including PVC casing caping ISI marked with all accessories surface type run on walls/ ceiling including MS terminal boxes fabricated with 1.6 mm thick MS sheet surface mounted / concealed on walls with plastic laminated sheet top cover 3 mm thick fixed with cadmium plated iron screws for housing the switches, switch socket outlets, fan regulators etc., including provision of 2.5 sq.mm PVC insulated single core multi stranded copper conductor cable as earth continuity conductor and connecting to common earth dolly, all as specified and as directed.
Surface point wiring by using 1.5 sq.mm PVC insulated unsheathed FRLS multi strandedcopper conductor cable drawn in suitable sunken box and frame cover plate for mounting of modular switches /sockets as required at site and provn of PVCcasing and caping medium density ISI marked fixed with all fittings and all accessories for mounting of switches and socket complete for one light/fan/socket point controlled by one switch including MS Sunken boxes, modular cover frame and provn of 1.5 sq.mm PVC insulated copper conductor contineous as earth wire connected to earth dolly complete all as specified and directed for one light point controlled by one switch.
All as per Sl Item No. 1.13 here in before but one fan point controlled by one switch/regulator.
All as per Sl Item No. 1.13 here in before but one 3 pin socket out let 5 Amps on independent board.
All as per Sl Item No. 1.13 here in before but one 3 pin socket out let 5 Amps on same board.
All as per Sl Item No. 1.13 here-in-before but for 16 Amps socket outlet by using 2.5 sq.mm PVC insulated unsheathed multi stranded copper conductor cable on independent board including provn of 2.5 sq.mm PVC insulated solid copper conductor continus as earth wire. NOTE FOR SL ITEM NO:-1.02 to 1.17 :- (i) The earth wire for the points in the same circuit can be looped from point to point. (ii) Earth wire shall be taken inside the conduit. (iii) Cost of terminal box is deemed to be included in the item rate quoted for point wiring. (iv) Cost of a circuit of any length of cable from DB to any switch/ socket board to be included in point wiring.
LED batten fittings, 18 watts, 6000K, (4 feet long), suitable for indoor applications wall mounted with extruded aluminium heat shink provision, efficient heat dissipation and integrated electronic driver, industrial batten type, powder coated top cover, with connector block etc., complete all accessories internally pre wired all as per Bajaj, Cat No.BCLAB 18 WH LED P / Halonix Cat No. HLB-03-18-CW-AL or techno commercially equivalent makes specified in PS including connecting up twin core twisted flexible copper conductor cable including taking down the existing fitting all as specified and directed.
LED batten fittings, 20 watts, 6000K, (4 feet long), suitable for indoor applications wall mounted with extruded aluminium heat shink provision, efficient heat dissipation and integrated electronic driver, industrial batten type, powder coated top cover, with connector block etc., complete all accessories internally pre wired all as per Bajaj, Cat No.BCLAB 20 WH LED P / Halonix Cat No. HLB-03-10-CW-IP or techno commercially equivalent makes specified in PS including connecting up twin core twisted flexible copper conductor cable including taking down the existing fitting all as specified and directed.
LED tube light fittings, 10 watts, 6000K, (2 feet long), wall mounted with plycorbanate housing and integrated electronic driver, industrial batten type, powder coated top cover, with connector block etc., complete all accessories internally pre wired all as per Bajaj, Cat No.BCLSB 10 WH / Halonix Cat No. HLB-03-10-CW-AL or techno commercially equivalent makes specified in PS including connecting up with twin core twisted flexible copper conductor cable including taking down the existing fitting all as specified and directed.
2' x 2' Recess mounted LED Luminaire, 43 Watts white powder coated CRCA housing with LEDs, seamless front frame with flat white high transmission arcylic cover complete with all accessories internally pre wired all as per Bajaj, Cat No : BZRSQL 43W GZ1 WH or techno commercially equivalent makes specified in PS including connecting up with twin core twisted flexible copper conductor cable including taking down the existing fitting all as specified and directed.
2' x 2' Recess mounted LED Luminaire, 36 Watts white powder coated CRCA housing with LEDs, seamless front frame with flat white high transmission arcylic cover complete with all accessories internally pre wired all as per Bajaj, Cat No : BZRSQL 36W GZ1 WH or techno commercially equivalent makes specified in PS including connecting up with twin core twisted flexible copper conductor cable including taking down the existing fitting all as specified and directed.
Aluminium extruded suspended type LED light fitting indoor applications 40 Watts with suspension chain/rod including jointing kit and all accessories all as per Bajaj, Cat No : BPCS 40W LED 4F L WH or techno commercially equivalent makes specified in PS including connecting up with twin core twisted flexible copper conductor cable including taking down the existing fitting all as specified and directed.
Modular type switch 6 Amps, one way including taking down the existing switch complete all as specified and directed.
Modular type switch 16 Amps, including taking down the existing switch complete all as specified and directed.
Modular type Socket outlet, 6 Amps, including taking down the existing socket outlet complete all as specifiedand directed.
Modular type Socket outlet, 6/16 Amps, including taking down the existing socket outlet complete all as specifiedand directed.
Modular fan regulator electronic step type including taking down the existing regulator complete all as specifed and directed.
Switch Piano flush button single pole two way 5 Amps including taking down the existing switch all as specified and as directed.
Angle holder PVC / polycarbonate type including taking down the existing holder all as specified and as directed.
Switch Piano flush type single pole one way 5 Amps including taking down the existing switch all as specified and as directed.
Switch socket outlet combination 5 pin, 2 in 1, 5 Amps flush type including taking down the existing socket outlet complete all as specified and as directed.
Switch socket combination, 2 in 1, 5 pin, 5 and 15 Amps flush type universal type including taking down the existing socket out let all as specified and as directed.
MCB SPN 240 volts 40 Amps including taking down the existing MCB complete all as specified and as directed.
MCB single pole 240 volts 6 to 32 Amps including taking down the existing MCB complete all as specified and as directed.
MCCB four pole, 415 volts, 160 Amps, 36 KA, adjustable type including taking out old unserviceable MCCB complete all as specified and as directed.
MCCB four pole, 415 volts, 125 Amps, 16 KA, fixed type including taking out old unserviceable MCCB complete all as specified and as directed.
MCCB four pole, 415 volts, 100 Amps, 16 KA, fixed type including taking out old unserviceable MCCB complete all as specified and as directed.
MCB TPN 415 volts , 63 Amps including taking down the existing MCB complete all as specified and as directed.
MCB DB SPN, 8 way, double door type, 240 volts with 200 Amps rated busbar including taking down the existing MCB DB all as specified and as directed.
MCB DB TPN 4 way with double door type 415 volts with 200 Amps rated bus bar for housing MCBs including taking down the existing MCB DB all as specified and as directed.
Vertical DB TPN, 4 way, suitable for MCCB upto 125 Amps as incoming, double door type, 415 volts, IP : 54 protection, door earthing, isolated neutral bar, mechanical impact strength IK 09 with insulated bus bar assembly all as per INDOASIAN Cat No. 812040 or techno commercially equivalent makes specified in PS including taking down the existing MCB DB all as specified and as directed.
Vertical DB TPN, 6 way, suitable for MCCB upto 125 Amps as incoming, double door type, 415 volts, IP : 54 protection, door earthing, isolated neutral bar, mechanical impact strength IK 09 with insulated bus bar assembly all as per INDOASIAN Cat No. 812041 or techno commercially equivalent makes specified in PS including taking down the existing MCB DB all as specified and as directed.
Vertical DB TPN, 12 way, suitable for MCCB upto 250 Amps as incoming, double door type, 415 volts, IP : 54 protection, door earthing, isolated neutral bar, mechanical impact strength IK 09 with insulated bus bar assembly all as per INDOASIAN Cat No. 812048 or techno commercially equivalent makes specified in PS including taking down the existing MCB DB all as specified and as directed.
Ceiling rose, surface bakelite type 65 x 50 mm, 2 to 3 terminals including taking down the existing eiling rose all as specified and as directed.
Electronic fan regulator flush and stepped typetype including taking down the existing regulator all as specified and as directed.
Sub main wiring power/circuit using FR PVC insulated unsheathed, 1100 volts grade, multi stranded copper conductor cable two runs of 6 sq.mm, one run of earth continuity conductor of size 6 sq.mm green in colour drawn through and including PVC casing and caping of suitable size, medium grade in walls / roof / floors including taking down the existing complete all as directed. NOTE:- Two runs of 6 sq.mm and one run of 6 sq.mm and one run of PVC casing and caping shall be measured as one unit.
Sub main wiring power/circuit using FR PVC insulated unsheathed, 1100 volts grade, multi stranded copper conductor cable two runs of size 4 sq.mm, onec run of earth continuity conductor of size 4 sq.mm green in colour drawn through and including PVC casing and caping of suitable size, medium grade in walls / roof / floors including taking down the existing complete all as directed. NOTE:- Two runs of 4 sq.mm and one run of 4 sq.mm and one run of PVC casing and caping shall be measured as one unit.
Sub main wiring power/circuit using FR PVC insulated unsheathed, 1100 volts grade, multi stranded copper conductor cable four runs single core of size 10 sq.mm, two runs of earth continuity conductor of size 10 sq.mm green in colour drawn through and including PVC casing and caping of suitable size, medium grade in walls / roof / floors including taking down the existing complete all as directed. NOTE:- Four runs of 10 sq.mm and two runs of of 10 sq.mm and one run of PVC casing and caping shall be measured as one unit.
Sub main wiring power/circuit using FR PVC insulated unsheathed, 1100 volts grade, multi stranded copper conductor cable four runs single core of size 16 sq.mm, two runs of earth continuity conductor of size 16 sq.mm green in colour drawn through and including PVC casing and caping of suitable size, medium grade in walls / roof / floors including taking down the existing complete all as directed. NOTE:- Four runs of 16 sq.mm and two runs of of 16 sq.mm and one run of PVC casing and caping shall be measured as one unit.
Earthing complete with galvanised steel plate electrode 600mm x 600mm x 6mm thick buried directly in ground (earth pit not less than 2.25mtr deep below ground level) with top edge not less than 1.5 m below ground level connected to earth lead by GI wire 4 mm dia by means of bolts nuts, check nuts, washers made out of galvanised iron connected to main switch all as shown in elect plate No 3 of MES SSR Part -I includingn excavation and earth work in any type of soil,funnel, 20 mm dia light grade GI watering pipe with chamber of PCC 1:3:6 type C1 40mm thick of size 450mm x450mm (1:2:4) type B1 for cover slab reinforced with 8mm dia TMT bars 10cm c/c both ways and with 6mm MS hook etc complete all as specified including testing on completion all as specified and directed.
Removing the window type AC / split type AC of 1.0/1.5/2.0 ton capacity from location, servicing the AC, cleaning the condenser and evaporator coil by blower, checking the electrical wiring, repalcement of burnt out wiring terminals, cleaning the air filter, gas charging, adjusting relays etc., replacement of unserviceable spare parts and fixing back at location, testing and commissioning complete all as directed.
Removing the split type AC 1.5 ton capacity of any make from position transporting to a reputed workshop, cutting the suction and discharge line of unserviceable compressor and replace with new factory made hermatically sealed compressor of same make and type, connecting the suction and discharge line, vacuuming the entire system, arresting all leakages, charging of required quantity of refrigerant, adjusting relays, thermostat etc bringing back and installing in its original position including testing and commissioning complete all as directed.
Removing the split type AC 2.0 ton capacity of any make from position transporting to a reputed workshop, cutting the suction and discharge line of unserviceable compressor and replace with new factory made hermatically sealed compressor of same make and type, connecting the suction and discharge line, vacuuming the entire system, arresting all leakages, charging of required quantity of refrigerant, adjusting relays, thermostat etc bringing back and installing in its original position including testing and commissioning complete all as directed. NOTE FOR SL ITEM NO 1.52 to 1.54 :- (i) Gas charging will be measured and paid separately for item No 1.52 to 1.54 under relevent item of this schedule. (ii) Spares costing more than Rs 200 will be measured and paid seperately under relevent item of this schedule.
Labour only for charging of refrigrent gas (R-22/410A/134A) of required quantity for split/window type AC of 1.50 ton capacity including leak detection by using nitrogen gas and arresting leakages if any by necessary brazing and flushing the system complete and testing complete all as specified and as directed.
Labour only for charging of refrigrent gas (R-22/410A/134A) of required quantity for split/window type AC of 2.0 ton capacity including leak detection by using nitrogen gas and arresting leakages if any by necessary brazing and flushing the system complete and testing complete all as specified and as directed.
Removing the unserviceable blower motor from the window type AC /split type AC, removing the burnt out winding from slots, rewinding with superior quality copper winding wire of higher insulation level, varnishing drying the motor complete and fixing in position incudingl testing and commissioning for 1.5/2 ton capacity complete all as specified and as directed.
Removing the damaged / unserviceable fan blades from the condenser motor shaft and replace new fan blade of the same size and type for any capacity of window /split type AC all as specified and directd.
Thermostat suitable for split/window type AC 1.5 / 2 ton capacity as per existing make of any type including removing the unserviceable thermostate complete all as specified and as directed. (Make- Indfos/Danfoss)
Condenser unit suitable for split/window type AC of 1.5 / 2 ton capacity connecting to the discharge line, brazing, vaccumising and gas charging the unit with required quantity of refrigerant and testing complete including removing the unserviceable condenser unit complete all as specified and as directed.
Running capacitor of 40 MFD suitable for split/window type AC 1.5 ton capacity as per existing make of any type including removing the unserviceable capacitor complete all as specified and as directed. Make :- BHEL / EPCOS/ TDK/ TIBCON or equivalent.
Starting capacitor of 80 / 100 MFD suitable for split/window type AC 1.5 TR / 2.00 TR capacity as per existing make of any type including removing the unserviceable capacitor complete all as specified and as directed. Make :- BHEL / EPCOS/ TDK/ TIBCON or equivalent.
Over load protector suitable for split/window type AC of 1.5/2.0 TR capacity including removing the unserviceable Over load protector complete all as specified and as directed.
Supply and fill Refrigrent gas (R-22/410A/134A) for ACs all as specified and as directed.
Sensor/remote of indoor unit suitable for 1.5 ton split type AC of any make including disconnecting and taking out the unservicable sensor/remote completely all as specified and as directed. Make :-carrier/Bluestar/Voltas
Sensor/remote of indoor unit suitable for 2.0 ton split type AC of any make including disconnecting and taking out the unservicable sensor/remote completely all as specified and as directed. Make :-carrier/Bluestar/Voltas
PCB suitable for split AC / window AC 1.5 Ton capacity of any type and any make including disconnecting and taking out the unservicable PCB all as specified and as directed.
PCB suitable for split AC / window AC 2.0 Ton capacity of any type and any make including disconnecting and taking out the unservicable PCB all as specified and as directed.
Disconnecting the PCB circuit suitable for 1.5/2 Ton capacity AC of any make and type, taking out PCB from AC, repairing the same and refixing in original location after reapirs complete all as specified and directed all as directed.
Disconnect electrical connection, removing copper line, discharge line of split type AC up to 2 Ton capacity including indoor and out door units and all accessories and shifting / reinstalling and testing the whole unit of split type AC in new location with suitable size and length of copper pipe and making the holes in walls complete all as specified.
Removing the unservicable voltage stabilizer of 4 KVA capacity from position, open the outer covers, removing the burnt out winding of existing transformer and rewinding with super quality insulated copper winding wire of suitable size and insulating properly including replacement of boost / buck relays, assembling the stabilizer complete and fixing back in original position and testing and commissioning complete all as specified and as directed.
Removing the unservicable voltage stabilizer of 5 KVA capacity from position, open the outer covers, removing the burnt out winding of existing transformer and rewinding with super quality insulated copper winding wire of suitable size and insulating properly including replacement of boost / buck relays, assembling the stabilizer complete and fixing back in original position and testing and commissioning complete all as specified and as directed.
M.G. Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .