Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance OFFICE NO 206 D WING EXTENSION RAIKER CHEMBER DEONAR VILLAGE ROAD GOVANDI EAST MUMBAI 88 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400088 | Admitted-Finance |
Tender Value
₹47 L
EMD Value
₹94,000
Closing Date
3 Jan 2023, 3:00 pmClosed
Chief Engineer GSS
3rd Floor North Wing V.S.Bhavan, Anushaktinagar, Mumbai-94
Maintenance contract for substation HT/LT switchgear panels, attending cable breakdown and associated works, rewinding/repairing of 1-ph/3-ph motors under DCSEM Mumbai
2022_DCSEM_728210_1
DCSEM/CQD/QSC/GSS/22-23/NIT-37
Open Tender
Electrical Works
Item Rate
548 days
Anushaktinagar include W.S, New mandala, OYC, Colaba
Please refer Tender Documents
8 documents required · 8 mandatory
₹0
₹94,000
31 Jan 2023
14 Dec 2022
4 Jan 2023
14 Dec 2022
3 Jan 2023
14 Dec 2022
14 Dec 2022 - 20 Dec 2022
Amount
PART A : Preventive maintenance
PART B : Supply of spares
PART C : Earthing system
PART D:Job works
PART E : Job works :
Description of Work / Item(s)
Amount
Preventive maintenance of Substation equipments as per tender specifications including taking shutdown with necessary work permit issued by shift in charge and giving line clearence certificate, submission of maintenance report, supply of all the required materials like panel locks,gaskets,void filling silicon paste,consumables,tools & testing equipement,ladders etc. required for maintenance and as instructed by E.I.C
11kV MOCB ( M/s Eswaran make)
11kV VCB HWX panel with VCB of M/s Schneider Electric(Areva) make
11kV VCB HWX panel with VCB of M/s Schneider Electric(Areva) make
Substation LT switchgear panels consisting of Main LT panel ,Battery charger & APFC panels
Testing of protection relays
Testing and Recalibration of over current, earth fault, under voltage and other protective relays of English Electric make -type-CDG-31/CDAG-53/CDG-53/CAG-14 numeric relay of M/s Ashida make/DPX/Micom P127 rlays installed in HT panels/LT panels/DG sets by secondary injection method to ascertain the healthiness of the relays in confirmation with the designed characteristics as per I.S standard and electricity code of practice, including the recalibration in case any deference in timing & load characteristics beyond the permissible limit to the maximum extend possible and as instructed by E.I.C
Testing of protection microprocessor based relases Micrologic 6E/6P/6A/MTX3.0/SR18 electronic release of ACBs/MCCB with test kits of respective manufacturers at site and submit the test reports as instructed by EIC
Breakdown maintenance of following distribution substation equipments shall be attended immedialty but not later than 01day including testing of circuit breaker contact resistance,HV test and opening and closing time etc. as instructed by EIC
11kV,RMU(RM6/FBX) of M/s Schneider Electric Make
1600A/2000A/4000A LT ACB (M-PACT series of M/s EE /U-power of L&T/NW of M/s Schneider Electric)
11kV MOCB ( M/s Eswaran make)
11kV VCB (HWX) M/s.Schnider Electric(Areva)make
Breakdown maintenance of battery charger of M/s Chabbi Electric Make/Universal make/Antronix make including supply required HRC fuses,contactors,indiaction lamps,annuciation windows etc. and as instrcuted by EIC
Transformer repair works
Arresting of minor oil leakages:Arresting of oil leakage by replacement of gaskets of transformer main tank cover, HT disconnection chamber, HT/LT terminal box covers, buccholz relay, valves, tap changers as required including replacement of faulty bushings if required with new HT/LT bushings of transformer capacities ranging from 250kVA to 1250kVA with necessary oil seals, gaskets, etc. replacement of oil seals of HT/LT bushings of transformers of capacities ranging from 250kVA to 1250kVA. Supply of material required for arresting oil leakage is included in the scope of work. No material will be supplied by dept. Note: i)Bushings required for attending will be separately paid. ii)The work done shall be guaranteed for a period of one year.
Replacement of gaskets of transfromer tank,radiator flanges,Bucholz relays,conservator,neutral bushing on tank,LV bushings,HV bushing with required thickness of good quality cock sheets, oil seals,rubber gaskets etc. including lowering of transformer oil into empty oil durms, refilling same after replacment of gaskets etc., replacement of faulty parts like glass indiactor on conservator,diaphragm of explosion vent,damaged check nuts of bushing if required,welding of flanges,joints of connecting MS pipes as required and as instructed by EIC i)Scope of work also includes providing torpolin sheet on whole area of transfomer yard. ii)Lifting of tranformer cover with hydralic lifter as required iii) Experienced technicians and service Engineer shall be deputed for the work. iv) The scope of the work also icludes supply of the materail required except bushing/radiators
Transformer oil related works
DGA test of transformer oil at any NABL accredited lab including sample collection from site and submission of test report all as per instruction of EIC.
Physical properties test of transformer oil at any NABL accredited lab including sample collection from site and submission of test report all as per instruction of EIC.
Online filtration of transformer oil of various size of transformers through streameline high vaccum filtering machine till the dielectric strength and other values in accordance with latest I.S specification are achieved, transportation of filtering machine from one place to another in Anushaktinagar, New Mandala colonies & OYC building,Colaba all as directed by the Engineer in-charge.
Supply of I.S specified fresh transformer oil with seal. The scope also include of transportation of oil from one place to another including topping of oil in transformer at Anushaktinagar & New Mandala colony all as instructed by the Engineer in-charge.
Description of Work / Item(s)
Amount
VCB panles of M/s Siemens make
Spring charging motor 220V DC/AC
Space heater (100/200W) plate type
Thermostats of Reputed make
Pin type panel locks
RMUs (FBX/RM6/MOCB of Ms Schneider Electric/Areva/MS.Eshwaran make)
110V,DC, shunt trip coil
48V,DC,shunt trip coil
Ashida numeric relay ADR241S
VAJH13,110-130V/48-50V DC relay(master trip relay)of M/S Alstom make
ACB spares(NW series of M/s Schneirder/M/s EE make)
110V,DC shunt trip coil
Sping charging motor(230V,AC)
Release for Ms/ Schneider Electric make ACB Micrologic 6E
Transfromers
1kg breathers for transformers with required coupler
Silica gel
Radiator for transformer upto 1250kVA capacity
APFC spares
25kVAR,MPP,heavy duty,3ph,440V,50HZ cylindrilcal type capacitor similar to VarPlus Can (H Duty) 440V Range of M/s Schnedier make
OFF delay timer 0-60sec
Capacitor duty contactor for 25kVAR with side add on block ( 1NO+ 1 NOC) similar to M/s Schneider make
Capacitor duty contactor for 60kVAR with side add on block ( 1NO+ 2 NC) similar to M/s Schneider make
Panel accessories
25A, 2NO+2NC,TNC switch
48V,DC/110V,DC/230V,AC LED indication lamp(green/red/Yellow/amber)
48V,DC/110V,DC/230V,AC LED indication lamp(White/Blue)
Battery charger spares
Digital Volt meter AC(48 X96/96X96)
Digital Volt meter DC (48 X96/96X96)
Digital Ammeter AC(48 X96/96X96)
Digital Ammeter DC(48 X96/96X96)
110V battery charger UIP make
Announciation window (Red Lens 24V DC)
Relay electronic type, 3C/O, 240 V AC coil with socket(R-OVR)
Relay Electronic type, 3C/O , 24V DC coil with socket(R-UVR)
SCR controller
SSA-3 (snubber ckt)
Pulse transformer Ckt (PTC)
Under voltage Ckt(DC UV)
Auto float boast Ckt(BR41)
Fuse monitor (FM)
Single phase preventor
Current transducer I/P: 0-75mV, O/P: 0-10V DC, Aux. supply.230V AC
Power supply, SMPS, IP: 90-270V AC/DC, O/P=24V, 2.5A (PS-41)
SMPS, I/P:24V DC, O/P=19-0-19V(PS-42)
Timer (TM-21) (24hrs. Coil supply:240VAC/DC
Buck regulator, I/P:160V DC to110V DC, O/P:110V/10A
48V battery charger UIP make
Announciation window (Red Lens 24V DC)
Realay electronic type, 3C/O, 240 V AC coil with socket
Relay Electronic type, 3C/O , 24V DC coil with socket
SCR controller
SSA-3 (snubber ckt)
Pulse transformer Ckt (PTC)
Under voltage Ckt(DC UV)
Auto float boast Ckt(BR41)
Earth fault relay Ckt.(ELR-41)
Fuse monitor (FM)
Single phase preventor
Power supply, SMPS, IP: 90-270V AC/DC, O/P=24V, 2.5A (PS-41)
SMPS, I/P:24V DC, O/P=19-0-19V(PS-42)
Timer (TM-21) (24hrs. Coil supply:240VAC/DC
Buck regulator, I/P:66V DC to 48V DC, O/P:48V/10A
Safety gears
LV hand gloves of M/s Raychem make or equivalnet for working voltage 440V
HV hand gloves of M/s Raychem make or equivalnet make for working volatges upto 11kV
Supply of Do not operate tag
Supply of caution danger text barricade tape 3 inch x 250 meter
Supply of Mutli functional meter similar CONZERV EM6436H with Class accuracy 1.0, 01 RS485 port of M/s Schneider make
Description of Work / Item(s)
Amount
Supply, installation, testing and commissioning of earth station with heavy dipped GI earth plates electrode 600 x 600 x6.0 mm in size at the depth minimum of 2.5 m below ground level (bottom of Plate) confirming to IS 3043 complete withall required materials like coke / charcoal, salt, G.I nut bolts, washers, 19 mm dia GI pipe (B class), 150 mm thick concrete wall chamber of suitable size duly plastered, heavy duty (minimum 6 mm thick) M.S chequred plate cover associated materials like 40 x 40 x 5 mm angle iron frame work, hinged locking arrangements, complete with funnels, GI test links (50 x 6 mm), two runs of 25 x 6mm G.I strips for connecting G.I plate & test link etc. including excavation of ground in all types of soils, refilling & removal of excess earth within a radius of 3000 m etc. all as required as per thedrawing specifications & instructed by Engineer-in-charge. Note:- The chamber cover & frame shall be got approved by Department & painted with two coats of red oxide & one coat of enamel paint.
Supply, installation of heavy dipped following GI strip fixed to wall / slab / column / beam with 2mm thick GI saddle or in ground at a depth of 750 mm below ground level including excavation in all type of soil, refilling and removal of excess earth within a radius of 500 mtrs., temporary reinstatement and back filling of trench, interconnection of earth strip by welding,applying cold zinc spary, painting with two coats of black bituminous compound for earth strip in ground and green colour enamel painting strip on surface etc. all as required & instructed by the Engineer-in-charge
25X 6mm in ground
25X 6mm on Wall/coloum/beam/bus ducts
50 X 6mm in ground
50X 6mm on Wall/coloum/beam/bus ducts
Cutting of asphalt road / concrete flooring /drain by using hydraulic drilling machine as required and stacking of rocks, refilling and consolidation of the surface. Disposing the excess earth within a 3000 meter radius as directed by engineer-in-charge
Excavation in soft soil including shorting or dewatering, removing of bricks/tiles etc. refilling and consolidation of the surface, disposing the excess earth within a 3000 meter radius as directed by engineer-in- charge.
Providing Plain cement concrete 1:3:6 using graded stone aggregate of 20 mm maximum size including consolidation, stacking, soling, frame work, shuttering as required, finishing, curing etc. Complete all as directed by Engineer in charge. Complete all as per specification & as directed by EIC.
Fabrication,supply & installtion of MS chequred plate of 6mm thick including painting with two coats of red oxided paint etc as per the site requirement.
Fabrication,supply,fixing of MS angles/flats supprots of required sizes & as per site requirement including painting with 1 coat of systhetic enamel paint over two coats of red oxide pain including fixing with suitable size of anchor fastner/coach screws on wall/ceiling etc. for electrcal installtions/cables etc.
Fabrication,supply,fixing of MS enclsoure made up of MS CRCA sheet including providing hinges/covers/gaskets etc as required including metal treament ,powder coating and as instructed by E.I.C
Supply, installtion and termination of G.I wire of 8SWG/14SWG/16SWG along with existing cable. As per instruction of EIC
Providing earth pit chamber made up of 150 mm thick concrete wall chamber of suitable size duly plastered, heavy duty (minimum 6 mm thick) M.S chequred plate cover associated materials like 40 x 40 x 5 mm angle iron frame work, hinged locking arrangements etc. Scope of work also includes breaking of existing earth pit chamber and disposing of debries.
Filling up of trench with M-sand / stone dust all as required and instructed by Engineer in charge.
Providing M.S. aldrops of 250 mm long with necessary hardwares by drilling & threading / welding in LT panel room / electric shaft doors including painting of welded area with red oxide paint to avoid corrosion in Malayagiri & Udayagiri buildings at Anushaktinagar all as per instruction of Engineer – in – Charge.
Replacement of door hinges set(02nos) in MDB/LT panel/feeder piller/LT cable chamber covers with necessary drilling/threading with tap/ welding, etc. all as per instruction of Engineer in-charge.
Measurement of earth pit resistance with earth resistance tester and letter painting of measured value with date and name of earth pit on the cover including painting of earthpit chamber all as per the instruction of EIC.
stage.html
html • 0.02 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .