Loading…
Loading…
| # | Company | Offered Item | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹29,000Qualified Make: microtek
Model: MICROTECK 5.0KVA CHANDRASEKHARPUR BHUBANESWAR ODISHA 751016 INDIA | KHORDHA | ODISHA | 751016 | Make: microtek
Model: MICROTECK 5.0KVA | L1 | Qualified |
Tender Value
Refer Docs
EMD Value
Exempted
Closing Date
10 Jul 2018, 10:00 amClosed
Inverter with sine wave output Experience with Gov. Required 5 Year (s) Inverter With Sine Wave Output ( 1 ) Technical Specifications Specification Specification Name Values Allowed Values GENERIC Inverter Governing specification Generally conforming to IS:13314 - Rating in KVA & Min. VAH Capacity of Battery 5 KVA/21600 VAH 5 KVA/21600 VAH Technology IGBT-PWM MOSFET-PWM
IGBT- PWM Energy Star Rating 3 Star 3 Star
4 Star
5 Star Trolley without trolley with trolley
without trolley Type of Battery Tubular battery confirming to IS:13369 Tubular battery confirming to IS:13369
VRLA battery confirming to JISC:8702(Pt.I
II&III) Backup time (Minutes) Minimum 180 Minutes - CONSTRUCTIONAL Thickness of sheet for trolley (in mm) minimum 1.2 - Trolley Material CRCA Steel - Type of enclosure CRCA Steel - Thickness of sheet for 1.2 - 1/3 enclosure ( in mm) minimum Inverter shall have by pass facility Yes - FUNCTIONAL Total Harmonic distortion </=5% - Input Single Phase sine wave(120 to 260 V) - Output Single Phase sine wave 230 V - Inverter Efficiency (%) >/=87% - Overload Time (in Minutes) >/=10 - Overload of rated load (in %) >/=10 - PROTECTION Battery cut-off voltage to protect from overdischarge (in Volt) >10.5 - Degree of protection IP 21 - METERING AND INDICATIONS The inverters shall be provided with output voltage and current meters conforming to IS 2419 : 1979 and of an accuracy class not inferior to 2.5 in accordance with IS 1248 : 1983 Yes - CERTIFICATIONS Availability of the Type Test Report from Central Govt. NABL/ILAC Accredited lab Yes - Climatic test report as per clause 7.10.1 of IS 13314 yes - Type Test Certificate No. 96000159 - Name of Lab BIS - Type Test Certificate date 02.07.2012 - Address of Lab Banaglore - Inverter shall have valid BIS CRS certifications for </= 10 KVA Yes - * Bold specifications are the golden parameters. 2/3 Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Rajkumar 152116
No 1 Battalion Abohar Military Station 1 15 Required No ePBG Required No
276287
GEM/2018/B/39229
Inverter with sine wave output
15 days
Punjab; Fazilka
PRODUCT
| Item | Delivery Location | Qty | Delivery |
|---|---|---|---|
| Inverter with sine wave output Experience with Gov. Required 5 Year (s) Inverter With Sine Wave Output ( 1 ) Technical Specifications Specification Specification Name Values Allowed Values GENERIC Inverter Governing specification Generally conforming to IS:13314 - Rating in KVA & Min. VAH Capacity of Battery 5 KVA/21600 VAH 5 KVA/21600 VAH Technology IGBT-PWM MOSFET-PWM | - | - | - |
| IGBT- PWM Energy Star Rating 3 Star 3 Star | - | - | - |
| 4 Star | - | - | - |
| 5 Star Trolley without trolley with trolley | - | - | - |
| without trolley Type of Battery Tubular battery confirming to IS:13369 Tubular battery confirming to IS:13369 | - | - | - |
| VRLA battery confirming to JISC:8702(Pt.I | - | - | - |
| II&III) Backup time (Minutes) Minimum 180 Minutes - CONSTRUCTIONAL Thickness of sheet for trolley (in mm) minimum 1.2 - Trolley Material CRCA Steel - Type of enclosure CRCA Steel - Thickness of sheet for 1.2 - 1/3 enclosure ( in mm) minimum Inverter shall have by pass facility Yes - FUNCTIONAL Total Harmonic distortion </=5% - Input Single Phase sine wave(120 to 260 V) - Output Single Phase sine wave 230 V - Inverter Efficiency (%) >/=87% - Overload Time (in Minutes) >/=10 - Overload of rated load (in %) >/=10 - PROTECTION Battery cut-off voltage to protect from overdischarge (in Volt) >10.5 - Degree of protection IP 21 - METERING AND INDICATIONS The inverters shall be provided with output voltage and current meters conforming to IS 2419 : 1979 and of an accuracy class not inferior to 2.5 in accordance with IS 1248 : 1983 Yes - CERTIFICATIONS Availability of the Type Test Report from Central Govt. NABL/ILAC Accredited lab Yes - Climatic test report as per clause 7.10.1 of IS 13314 yes - Type Test Certificate No. 96000159 - Name of Lab BIS - Type Test Certificate date 02.07.2012 - Address of Lab Banaglore - Inverter shall have valid BIS CRS certifications for </= 10 KVA Yes - * Bold specifications are the golden parameters. 2/3 Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Rajkumar 152116 | - | - | - |
| No 1 Battalion Abohar Military Station 1 15 Required No ePBG Required No | - | - | - |
Exempted
10 Jul 2018
1 Jul 2018
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_276287.pdf
GEM_BID
termsCondition.pdf
OTHER
2657c7ca70287299b5181580fdb5a7ab.pdf
OTHER
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .