Design, Installation and Commissioning of Permanent Cathodic Protection (PCP) System for Underground Steel Pipeline Networks of Haldia GA (Group G)
2026_BD_190217_7
BD/CONT/26-27/040
Open Tender
Electrical Works
Works
730 days
IOCL BD
As per tender Documents
5 documents required · 5 mandatory
₹34,000
IOCL BD through WEB
16 Jul 2026
12 Jun 2026
14 Jul 2026
12 Jun 2026
13 Jul 2026
26 Jun 2026
22 Jun 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 10PCP Works (Group-G) Haldia GA | |||||
| 10.01 | Soil Resistivity and Chemical analysis | - | - | - | - |
| 10.02 | "Conducting ""Soil Resistivity Survey"" at anode bed location after ascertaining its suitability for installation of Anode Bed (dee p / shallow / distributed), as per the specification, approved procedures and instructions of Site Engineer /Engineer-in-Charge. Note : At each CP station location soil resistivity shall be measured upto 100 m depth for 3 plots, for selection of the anode bed f or the lowest resistivity plot." | 3 | EA | 32,749.38 | ₹98,248.14 |
| 10.03 | Soil Chemical analysis as per specification | 3 | EA | 27,973.17 | ₹83,919.51 |
| 10.04 | Design | - | - | - | - |
| 10.05 | Design, Detailed Engineering for Permanent Cathodic Protection system as per the specification | 1 | LS | 2,59,468.63 | ₹2,59,468.63 |
| 10.06 | "Transformer Rectifier Unit TRU" | - | - | - | - |
| 10.07 | "Supply, Installation,Testing & Commissioning of the below rated dual input (230 V AC & 48 V DC) type Cathodic Protection Smart Tra nsformer Rectifier Unit with built in GSM Modem, RTU and display unit of approved make, complete in all respects as given in the sp ecification and directions of Site Engineer/ Engineer—in-Charge with all its accessories to ensure trouble free operation: Transformer Rectifier Unit - 25V/25A , single phase or three phase, Air cooled, Indoor type with remote monitoring through Pipelin e’s SCADA facility." | 1 | EA | 4,35,314.44 | ₹4,35,314.44 |
| 10.08 | "Supply, Installation,Testing & Commissioning of the below rated input (230 V AC) type Cathodic Protection Smart Transformer Rectif ier Unit with built in GSM Modem, RTU and display unit of approved make, complete in all respects as given in the specification and directions of Site Engineer/ Engineer—in-Charge with all its accessories to ensure trouble free operation: Transformer Rectifier Unit - 25V/25A , single phase or three phase, Air cooled, Indoor type with remote monitoring through Pipelin e’s SCADA facility." | 2 | EA | 4,20,539.58 | ₹8,41,079.16 |
| 10.09 | Anode Ground Bed | - | - | - | - |
stage.html
html • 0.02 MB
cancelled_1.pdf
pdf • 0.24 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 1.08 MB
Tender-Acceptance-Format.pdf
Additional Documents • 0.08 MB
FAQs-IOCL-Online-EMD.pdf
Additional Documents • 0.55 MB
Bidders_help_Document_for_Preferencial_Bidding_20230207_v1.pdf
Additional Documents • 0.82 MB
Special_Instructions_to_the_Bidders_Version_5_dated_30_June_2025.pdf
Additional Documents • 2.80 MB
TenderDocuments.pdf
Tender Documents • 28.29 MB
BOQ_200511.xls
BOQ • 0.39 MB
Datecorrigendum040.pdf
PDF • 0.03 MB
PreBidClarifications.pdf
PDF • 1.32 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .