| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.3 LAdmitted-Finance 112 21 A 2 K N MUKHERJEE ROAD P O TALPUKUR BARRACKPORE 24 PGS N | 24 PARAGANAS NORTH | WEST BENGAL | 700028 | L1 | Admitted-Finance | |
| 2 | L2₹2.4 L+₹10,002 (4.38%)Admitted-Finance | L2 | Admitted-Finance | |
| 3 | L3₹2.4 L+₹16,177 (7.08%)Admitted-Finance 159 KAILASH GHOSHI ROAD KOLKATA WEST BENGAL 700008 | KOLKATA | KOLKATA | WEST BENGAL | 700008 | L3 | Admitted-Finance |
| Sl No | Description | Qty | Unit | MIK ENTERPRISES L1 | POWER INDIA L3 | PASS TREAT L2 |
|---|---|---|---|---|---|---|
| 1.00 | Maintenance and overhauling of V.T. / inclined pumps as per manufacturers instruction manual with all tools, tackles etc. This job includes labour charges, consumables like O - ring, sundry cleaning material etc. This job includes dismantling of all sub-assemblies such as gear box, cooling pipes, bearing housing, stuffing box, discharge tee, muff couplings, shafts, column pipes, bowl assembly, bell mouth, strainer, line shaft enclosing tube etc. Reconditioning of all parts, inspection of all parts & replace these parts as per instructions (spares cost excluded) straightening of shafts & refitting of all parts & sub-assemblies with proper alignment including motor removing & refixing, test & trial for 24 hrs etc complete.Capacity up to 05 cusec pump | 1 | No. | 25,140 ₹25,140 Lowest | 26,186 ₹26,186 | 25,220 ₹25,220 |
| 2.00 | Cost of replacement of damaged line shaft / cleaning of jammed impeller of V.T./ inclined pumps as per manufacturers instruction manual with all tools, tackles, consumables such as gland packing etc. This job includes dismantling of pump assembly parts by parts and replacement of damaged parts, refitting of all parts & sub-assemblies with proper alignment including motor removing & refixing, test & trial for 24 hrs. etc. complete as per direction (spare cost excluded).Capacity upto 05 cusec pump | 1 | No. | 9,680 ₹9,680 Lowest | 9,720 ₹9,720 | 9,825 ₹9,825 |
| 3.00 | Maintenance and overhauling of C.I. non-return valve after dismantling it from delivery pipe line and checking part by part, cleaning, lubricating and thorough servicing the valve. This job includes labour charges, consumables like rubber gasket, sundry cleaning materials, lubricants & replace damaged parts as per instructions(spares cost excluded)&refitting of all parts with proper alignment as per direction | 3 | Nos. | 13,810 ₹41,430 Lowest | 14,380 ₹43,140 | 14,128 ₹42,384 |
| 4.00 | Maintenance and overhauling of isolating sluice valve after dismantling it from delivery pipe line and checking part by part, cleaning, lubricating and thorough servicing the valve. This job includes labour charges, consumables like rubber gasket, sundry cleaning material, lubricants & replace damaged parts as per instructions (spares cost excluded) & refitting of all parts with alignment. | 3 | Nos. | 13,814 ₹41,442 Lowest | 14,345 ₹43,035 | 14,300 ₹42,900 |
| 5.00 | Lowering, fitting and fixing of all types of valves in proper position and alignment using chain pully block or crane 250mm dia. | 6 | Nos. | 3,130 ₹18,780 Lowest | 3,415 ₹20,490 | 3,200 ₹19,200 |
| 6.00 | Taking out the L.T.sq.cage Induction Motor after disconnections of supply terminal connections including earthing terminal connection, from coupling end of 25/50 cusec vertical axial flow propeller pump after dismantling the same from the motor stool.The motor is to be kept on woodens leeper at a suitable distance from the floor without damaging the earthing strips and cables etc. as per direction of E.I.C | 1 | No. | 1,760 ₹1,760 Lowest | 2,010 ₹2,010 | 1,950 ₹1,950 |
| 7.00 | Preliminary checking of the whole motor (LT sq. cage IM) and testing of I.R. value, load currents, leakage factor of stator & rotor, terminal lead joints of stator connection ends, insulation of glass fibre terminal bar,double cage rotor end rings and all of motor bars and bar joints,housing of D.E.&NDE shield bearing housing etc. before work to detect fault. | 1 | No. | 5,011 ₹5,011 Lowest | 5,312 ₹5,312 | 5,120 ₹5,120 |
| 8.00 | Complete servicing and heat varnishing of 415Volt, 3 Phase L.T. sq. cage induction motor after cleaning the stator and heating it up periodically and varnishing by Dr. Beck’s graded insulating varnish to obtain stable IR value,cleaning up the rotor,including heating for demoisturisation, lacker coating on the surface of rotor stampings, cleaning and RO priming on the end shield covers, bearing housing and complete .Upto 75 KW LT sq.cage IM | 1 | No. | 20,100 ₹20,100 Lowest | 21,850 ₹21,850 | 21,000 ₹21,000 |
| 9.00 | Refitting the pump motor(LT sq.cage IM)set with all its necessary coupling and accessories to its original position including fitting fixing with bearing housing non-reversable rachet unit and pump shaft with proper tolerance and clearance and reconnection of terminal points the overhauling work i.e. cleaning of contracts sliping etc.(all connection strips,cable end are to be refitted in proper way including good damages of strip terminals) and satisfactory 2 hours trial run of the pump as per direction of E.I.C. for all pumping stations. | 1 | No. | 2,740 ₹2,740 Lowest | 2,900 ₹2,900 | 3,010 ₹3,010 |
| 10.00 | Supply and delivery of Cotton Impregnated with lubricant- Hydraulic Gland Packing (Style-376), Thickness- 13 to 25mm, Make- Champion | 10 | Kg | 656 ₹6,560 Lowest | 928 ₹9,280 | 780 ₹7,800 |
Tender Value
Refer Docs
EMD Value
₹4,650
Closing Date
16 Sept 2026, 1:00 pmClosed
Executive Engineer, GAP-I, EM, KMDA
Office of the Executive Engineer, GAP-I, EM, KMDA, 83 1A Vivekananda Road, 3rd floor, Kolkata-700006
Repairing, servicing, overhauling of 1 No VNC Pump and allied Electro-mechanical works at Serampore LS-III under GAP-I, EM, KMDA
2026_KMDA_1039909_1
07/EE(E/M)/GAP-I/ EM/KMDA/T-07(E)/2026-27 Dt. 25/08/2026
Open Tender
Electrical Work/ Equipment
Item Rate
15 days
Serampore
Please refer Tender documents.
4 documents required · 4 mandatory
₹0
₹4,650
Office of the Executive Engineer, GAP-I, EM, KMDA
28 Sept 2026
8 Sept 2026
18 Sept 2026
8 Sept 2026
16 Sept 2026
8 Sept 2026
10 Sept 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Maintenance and overhauling of V.T. / inclined pumps as per manufacturers instruction manual with all tools, tackles etc. This job includes labour charges, consumables like O - ring, sundry cleaning material etc. This job includes dismantling of all sub-assemblies such as gear box, cooling pipes, bearing housing, stuffing box, discharge tee, muff couplings, shafts, column pipes, bowl assembly, bell mouth, strainer, line shaft enclosing tube etc. Reconditioning of all parts, inspection of all parts & replace these parts as per instructions (spares cost excluded) straightening of shafts & refitting of all parts & sub-assemblies with proper alignment including motor removing & refixing, test & trial for 24 hrs etc complete.Capacity up to 05 cusec pump | 1 | No. | - | - |
| 2 | Cost of replacement of damaged line shaft / cleaning of jammed impeller of V.T./ inclined pumps as per manufacturers instruction manual with all tools, tackles, consumables such as gland packing etc. This job includes dismantling of pump assembly parts by parts and replacement of damaged parts, refitting of all parts & sub-assemblies with proper alignment including motor removing & refixing, test & trial for 24 hrs. etc. complete as per direction (spare cost excluded).Capacity upto 05 cusec pump | 1 | No. | - | - |
| 3 | Maintenance and overhauling of C.I. non-return valve after dismantling it from delivery pipe line and checking part by part, cleaning, lubricating and thorough servicing the valve. This job includes labour charges, consumables like rubber gasket, sundry cleaning materials, lubricants & replace damaged parts as per instructions(spares cost excluded)&refitting of all parts with proper alignment as per direction | 3 | Nos. | - | - |
| 4 | Maintenance and overhauling of isolating sluice valve after dismantling it from delivery pipe line and checking part by part, cleaning, lubricating and thorough servicing the valve. This job includes labour charges, consumables like rubber gasket, sundry cleaning material, lubricants & replace damaged parts as per instructions (spares cost excluded) & refitting of all parts with alignment. | 3 | Nos. | - | - |
| 5 | Lowering, fitting and fixing of all types of valves in proper position and alignment using chain pully block or crane 250mm dia. | 6 | Nos. | - | - |
| 6 | Taking out the L.T.sq.cage Induction Motor after disconnections of supply terminal connections including earthing terminal connection, from coupling end of 25/50 cusec vertical axial flow propeller pump after dismantling the same from the motor stool.The motor is to be kept on woodens leeper at a suitable distance from the floor without damaging the earthing strips and cables etc. as per direction of E.I.C | 1 | No. | - | - |
| 7 | Preliminary checking of the whole motor (LT sq. cage IM) and testing of I.R. value, load currents, leakage factor of stator & rotor, terminal lead joints of stator connection ends, insulation of glass fibre terminal bar,double cage rotor end rings and all of motor bars and bar joints,housing of D.E.&NDE shield bearing housing etc. before work to detect fault. | 1 | No. | - | - |
| 8 | Complete servicing and heat varnishing of 415Volt, 3 Phase L.T. sq. cage induction motor after cleaning the stator and heating it up periodically and varnishing by Dr. Beck’s graded insulating varnish to obtain stable IR value,cleaning up the rotor,including heating for demoisturisation, lacker coating on the surface of rotor stampings, cleaning and RO priming on the end shield covers, bearing housing and complete .Upto 75 KW LT sq.cage IM | 1 | No. | - | - |
| 9 | Refitting the pump motor(LT sq.cage IM)set with all its necessary coupling and accessories to its original position including fitting fixing with bearing housing non-reversable rachet unit and pump shaft with proper tolerance and clearance and reconnection of terminal points the overhauling work i.e. cleaning of contracts sliping etc.(all connection strips,cable end are to be refitted in proper way including good damages of strip terminals) and satisfactory 2 hours trial run of the pump as per direction of E.I.C. for all pumping stations. | 1 | No. | - | - |
| 10 | Supply and delivery of Cotton Impregnated with lubricant- Hydraulic Gland Packing (Style-376), Thickness- 13 to 25mm, Make- Champion | 10 | Kg | - | - |
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.29 MB
BOQ_2553827.xls
BOQ • 0.33 MB
Form.pdf
Tender Documents • 0.66 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .