Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹45.6 LAccepted-AOC 205 PARSHAV VIHAR PLOT NO 50 1 P EXTN PATPARGANJ DELHI 110092 | DELHI | EAST DELHI | DELHI | 110092 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹48.2 L+₹1.5 L (3.15%)Rejected-AOC | L2 | Rejected-AOC Not being L1 | |
| 3 | L3₹49.0 L+₹2.3 L (4.84%)Rejected-AOC | L3 | Rejected-AOC Not being L1 |
Tender Value
₹49.5 L
EMD Value
₹99,100
Closing Date
12 Jan 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer EM RR Hosp
Garrison Engineer EM RR Hosp RAO Tula Ram Marg Delhi Cantt-10
CA NO GE/H 31/2020 21 NAME OF WORK REPAIR/MAINTENANCE OF LT DISTRIBUTION LT BUSBAR SYSTEM AND ALLIED WORKS AT AHRR UNDER GE E/M R AND R HOSP DELHI CANTT10
2020_MES_401776_1
GE/H-31/2020-21
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE E/M RR HOSP DELHI CANTT 10
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE E/M RR HOSP DELHI CANTT 10
₹99,100
Yes
15 Feb 2021
8 Dec 2020
14 Jan 2021
8 Dec 2020
12 Jan 2021
21 Dec 2020
60 days
Amount
Excavation in trenches in soft / loose soil not exceeding 1.5 meter depth and not exceeding 1.5 meter wide and getting out complete all as directed.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick complete all as directed.
Removal of excavated material not exceeding 50 meters and depositing where directed at a level not exceeding 1.5 meter above the starting point complete all as directed.
M&L for sand cushioning with layer of sand 8cm thick before laying of cable and 15cm after laying of cable in trenches complete all as directeld and sand cover to under ground cable complete all as directed.
Supplying and laying reinforced precast concrete cable cover ,Class LV, Type I, flat, size 250mm x 150mm x 40mm for cable protection all as specified.
Taking out old defective under ground cable from trenches floor / road / wall / pipe/ pole of size and description, complete all as directed.
Material and Labour for relaying the serviceable part of cable taking out under above mention items after repairing defects / making joints etc in same trench or any other location, complete all as directed. Note : 1. The excacation, earth work, sand cushioning, protection cover, and cable joints etc will be measured and paid for seperately under respective items.
Supply & laying XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, in trench/ in pole/ in duct of follwing sizes:-
(a) 3.5 core x 50 sqmm.
(b) 3.5 core x 70 sqmm.
(c) 3.5 core x 95 sqmm.
(d) 3.5 core x 120 sqmm.
(g) 3.5 core x 400 sqmm.
Note for 8 :- 1. The cost of AI thimbles / lugs/clamps/fastner and cable gland etc are deemed to be included in quoted rate and no extra payment shall be made on this account
S&F of GI pipe of 80 mm bore light grade fixed to poles with clamps nuts, bolts and washers or laid under road crossing or fixed to wall including painting with two coats of aluminium paint over a coat of red oxide paint complete all as directed. Note : The cost of MS clamp, nut, bolt, washer and GI fittings etc shall be inclusive in the item rate.
All as per srl item No 9 here-in-before but for GI pipe of 50 mm bore size.
M&L for road cutting 60 mm wide and 900 mm deep, including excavation, returning filling in, spreading, leveling well ramming in layers,soling, WBM 7.5 cm thick coarse aggregate received from dismentling the existing road, premix, carpeting 25 mm thick using ready mix patch mate material, rolled and compacted for road patch repair work, complete all as directed.
M&L for complete control rewiring of 3x40 kVAR capacitor panel for automatic switching of capacitor banks using 2.5 sqmm, FRLS, multistranded PVC insulated unsheathed copper cable, also all power cables upto 25 sqmm, FR, multistranded PVC insulated unsheathed copper cable connecting to main incoming also with capacitor duty contactor and including cable tray for carrying the wires, din rail for melamine complete to the operation of APFC relay, ammeter, voltmeter, LED, indicator etc to make panel fully automatic switching of capacitor banks including taking out of old wiring, complete all as directed.
S&F in replacement of micro controller automatic power factor control relay, 415volts, 50Hz, three phase three wire, 08 stage suitable for APFC Panal off capacity and including taking down of unserviceable relay and making all electric connection, in existing panel, complete all as directed.
S&F in replacement of capacitor duty contactor, suitable for capacitor of 40 kVAR, 415V, AC, 3ph, 50Hz, with built-in-auxiliary contacts, with and including taking down of unserviceable contactor and making all electric connection, in existing panel, complete all as directed.
Ditto all as per Item No 14 but for 25 kVAR, 415V, AC, 3ph, 50Hz
Ditto all as per Item No 14 but for 20 kVAR, 415V, AC, 3ph, 50Hz
Supply, fixing, testing and commissioning, in replacement, of MPP heavy duty box type (resin filled) capacitor of 40 KVAr Capacity, 440 Volt, 50Hz, 3 phase.
All as per srl item No. 17 here-in-before but 20 KVAr capacity.
All as per srl item No. 17 here-in-before but 25 KVAr capacity.
S&F in replacement of LED type indicator lamp of red colour for phase indication with and including taking down of unserviceable indicator and making all electric connection, in existing panel, complete all as directed.
Ditto as per item No 20 above but for yellow phase.
Ditto as per item No 20 above but for Blue phase.
Ditto as per item No 20 above but for Green for indicating system is OFF.
Supply and fixing replacement of microprocessor based MCCB, 415 volts, four pole of capacity 100 Amps, 16 KA, ICS = 100% ICU, including spreader terminals, phase barriers, thimbles of suitable size etc and making electric connections and taking down old unserviceable MCCB, complete all as directed.
All as per items No. 24 here-in-before but 125 Amp capacity, 25 KA
All as per items No. 24 here-in-before but 160 Amp, 25 KA capacity
All as per items No. 24 here-in-before but 250 Amp, 25 KA capacity
All as per items No. 24 here-in-before but 400 Amp, 36 KA capacity
M & L Earthing complete with galvanized steel earth plate electrode 60cmx60cmx60xm thick buried directly in ground(earth) pit not less than 2.25 meter deep below normal ground level) with top edge of earth plate not less than 1.5mtr below normal ground level connected to galvanized earth strip of size 25 mm x 4 mm by means of bolts, nuts check nuts and washers of galvanized iron or steel all as shown in electrical palte No 3 of SSR Pt-I connected earthing test point/panel all as specified including GI PCC earth chamber using PCC(1:3:6) Type C-2 using, graded stone aggregate, 5mm thick cast iron frame, with CI cover ( size of cover 260x260mm x5 mm) including lifting handle, funnel and wire mesh necessary excavation and earth work complete all as specified and directed.
S&F bus bar chamber out door type 800 Amps rated colour coded insulated aluminium bsbar 4 Nos, suitable for one incoming and one outgoing of 400 Sqmm 3.5 core XLPE cable, and provn of phase identification RYB indication lamp and 02 Nos earth connection to the chamber, with angle iron legs size 40 x 40 x 6 mm, standard PCC foundation & copping, cable connection with suitable cable glands etc all as specified and directed by Engr-in-Charge. Note: (i) All busbar chambers shall be manufactured by CPRI approved LT panel manufacturer(ii) Busbar shall be in stepped manner in busbar chamber.
Ditto all as per item No 30 but for 630 Amps.
Ditto all as per item No 30 but for 400 Amps.
Ditto all as per item No 31 but for 320 Amps.
Ditto all as per item No 31 but for 200 Amps. .
Supply only Heat shrinkable LT 1.1 KV straight through joint suitable for aluminium cable of Size 400 Sqmm x 3.5 core all as specified .
Ditto all as per item No 36 but for 185 Sqmm to 240 sqmm x 3.5 core .
Ditto all as per item No 36 but for 120 Sqmm to 150 sqmm x 3.5 core .
Ditto all as per item No 36 but for 70 Sqmm to 95 sqmm x 3.5 core .
Ditto all as per item No 36 but for 35 Sqmm to 50 sqmm x 3.5 core .
S&F, in replacement, of tap off box enclosure, metal body type, with provision of interlock to prevent removal when outgoing device is in ‘ON’ position and with provision of interlock to prevent turned 'ON' MCCB When the tap-off unit cover is ‘OPEN’, suitable for aluminium busbar trunking 800 Amps, 3 phase, 4 wire including suitable neutral link & glands and suitable for all types of MCCBs i.e. 4 pole of ratings from 100 Amp 125 Amp, complete all as directed. Make : Legrand (Zucchini) Part No 50414002 or equivalent in Siemens/ GE. Note : The MCCB shall be measured & paid separately under respective items of schedule.
All as per srl item No. 40 here-in-above but for busbar trunking upto 800 Amp rating and suitable for all types of MCCBs i.e. 4 pole of ratings 250 Amp. Make : Legrand (Zucchini) Part No 50414004 or equivalent in Siemens / GE.
Servicing of ACBs by taking out Air circuit breaks of capacity 1250-2500 amps from LT panels cleaning all parts internally and externally checking of the proper tension of the springs mechanical mechanism, tightening of connection of moving, fixing contract, floating contacts, servicing of motor, and charging system and re-fixing it on its original position and testing including testing of control wiring of the respective ACBs complete all as directed by Engr In Charge. Note : Rate is deemed to include minor items ie. jelly, grease, s/c copper cable upto 1.5 sqmm, screws & locking system.
All as per above item No 42 but of capacity 630-1000 Amps.
Supply & Fixing LED Voltmeter 3 phase accuracy CI 0.5 50 to 520 Volts AC (96 mmx 96 mm).
Supply & Fixing LED Ammeter with 630 amps capacity Cts, 3 phase accuracy CI 0.5 AC ( 96 mmx96mm)
Ditto all as per item No 46 but capacity 1600 Amp.
Ditto all as per item No 46but capacity 1000 Amp.
S&F in replacement MCCB 200 Amps with Overload adjustable and short circuit adjustable , 4 pole, 415 volt, 50Hz, breaking capacity 25 KA, 200 Amp, XT4 MCCB, Cat pt No 1SDA068109R1, Rotary Handle Cat Pt No 1SDA054934R1, Spreaded terminals Cat Pt No 1SYN450210R0001, Separator Cat Pt No 1SYN850210R001 of make ABB or equivalent in L&T/ Legrand
Supply and fixing in replacement of automatic transfer switch (ATS) of 200 Amps capacity, 04 pole, 440 volt, 50 Hz having automatic/manual control with inbuilt time delay, protection against single phasing, over voltage, under voltage and inbuilt phase correction, with steel enclosure complete with all accessories, complete all as directed. Make: L&T/ABB/Legrand
Supply and fixing in replacement of change over switch off load type of capacity 400 Amps capacity, 04 pole, 440 volt, 50 Hz with steel enclosure complete with all accessories, complete all as directed.
Supply, fabricate, instll, test and commissioning LT control panel outdoor type powder coated, weather proof,dust proof,vermin proof made out of 3.15 mm thick CRCA sheet front and back openable door, angle iron frame and locking arrangement with pad lock, including suitable working space in bus bar chamber, cable box chamber with alley suitable for 3phase 4 wire system,415V, 50 Hz,AC supply including aluminium bus raisers with PVC sleeves/ tape RYB colours for phases identification,including all bus raiser shall be extend upto cable box chamber fixed on fibre insulation for RYB & neutral to all out going cable, confirming to IP-54 and fixed on raised PCC platform with PCC 1:2:4,type B1 (20mm graded aggregate) raised base with control wiring with comprissing cable gland brass, copper/brass lugs etc. including dismantling the unserviceable panel and compressing the following. Near AHPS
(i) 1000 A aluminium bus bar TPN system.
(ii) MCCB 4 Pole 440 volts AC 50 Hz 400 Amps 36 kA, microprocessor based thermal magnetic release Ics-100% Icu100% - 01 No
(iii) Change over switch ON load Open execution 400 Amps 4 Pole, AC 50 Hz 440 Volt -01
(iv) MCCB 4 Pole 440 volts AC 50 Hz 250 Amps 25 kA, microprocessor basedthermal magnetic release Ics-100% Icu100% - 01 No
(v) MCCB 4 Pole 440 volts AC 50 Hz 125 Amps 25 kA, microprocessor based thermal magnetic release Ics-100% Icu100% - 01 No
(vi) MCCB 4 Pole 440 volts AC 50 Hz 100 Amps 16 kA,microprocessor based thermal magnetic release Ics-100% Icu100% - 02 No
(vii) MCCB 4 Pole 440 volts AC 50 Hz 63 Amps 16 kA, microprocessor based thermal magnetic release Ics-100% Icu100% - 02 No
(viii) Indication lamp RYB for phase indication- 01 Set of three
(ix) Intelligent meter with all parameter as specified in Part No- CSM-A-M5-S3 of C&S with suitable capacity of 03 Nos CT's - 01
(x) Space for MCCB for future extension - 01 Nos
(xi) Space for installation of existing 3 phase energy meter -01
(ix) angle iron frame 40x 40x 6 mm for support of panel height as directed by Engr In Charge .
Ditto all as per items Ser No 53 here in before but comperising the following:- (Offr Mess)
(a) Aluminium busbar 400 amps TPN
(b) MCCB 4 Pole 440 volts AC 50 Hz 250 Amps 36 kA ,microprocessor based thermal magnetic release Ics-100% Icu100% - 01 No
(c) MCCB 4 Pole 440 volts AC 50 Hz 63 Amps 16 kA ,microprocessor based thermal magnetic release Ics-100% Icu100% - 02 No
(d) Indication lamp RYB for phase indication- 01 Set of three
(e) Intelligent meter with all parameter as specified in Part No- CSM-A-M5-S3 of C&S with suitable capacity of 03 Nos CT's - 01
(g) Space for installation of existing 3 phase energy meter -01
(h) angle iron frame 40x 40x 6 mm for support of panel height as directed by Engr In Charge .
Ditto all as per items Ser No 53 here in before but comperising the following:- (Near Combat Events & out gate )
(a) Aluminium busbar 200 amps TPN
(b) MCCB 4 Pole 440 volts AC 50 Hz 160 Amps 25 kA ,microprocessor based thermal magnetic release Ics-100% Icu100% - 01 No
(c) MCB TPN 415 volts AC 50 Hz 40 amps 15KA 'C' curve - 04 No
(d) Indication lamp RYB for phase indication- 01 Set of three
(e) Intelligent meter with all parameter as specified in Part No- CSM-A-M5-S3 of C&S with suitable capacity of 03 Nos CT's - 01
(f) Timer switch digital.
(g) Surge Protection Device 3P+N 4 module including control wiring.
(h) angle iron frame 40x 40x 6 mm for support of panel height as directed by Engr In Charge .
Ditto all as per items Ser No 53 here in before but comperising the following:- (behind Ashra)
(a) Aluminium busbar 400 amps TPN
(b) MCCB 4 Pole 440 volts AC 50 Hz 200 Amps 25 kA ,microprocessor based thermal magnetic release Ics-100% Icu100% - 01 No
(c) MCCB 4 Pole 440 volts AC 50 Hz 100 Amps 25 kA ,microprocessor based thermal magnetic release Ics-100% Icu100% - 01 No
(d) MCCB 4 Pole 440 volts AC 50 Hz 63 Amps 25 kA ,microprocessor based thermal magnetic release Ics-100% Icu100% - 02 No
(e) Indication lamp RYB for phase indication- 01 Set of three
(f) Intelligent meter with all parameter as specified in Part No- CSM-A-M5-S3 of C&S with suitable capacity of 03 Nos CT's - 01
(g) Space for MCCB for future extension -01
(h) angle iron frame 40x 40x 6 mm for support of panel height as directed by Engr In Charge .
Ditto all as per items Ser No 53 here in before but comperising the following:- (Near P-1)
(i) 400 A aluminium bus bar TPN system.
(ii) MCCB 4 Pole 440 volts AC 50 Hz 250 Amps 36 kA, microprocessor based thermal magnetic release Ics-100% Icu100% - 01 No
(iii) Change over switch Off load Open execution 250 Amps 4 Pole, AC 50 Hz 440 Volt -01
(iv) MCCB 4 Pole 440 volts AC 50 Hz 160Amps 25 kA, microprocessor based thermal magnetic release Ics-100% Icu100% - 01 No
(v) MCCB 4 Pole 440 volts AC 50 Hz 100Amps 25 kA, microprocessor based thermal magnetic release Ics-100% Icu100% - 01 No
(vi) Indication lamp RYB for phase indication- 01 Set of three
(vii) Intelligent meter with all parameter as specified in Part No- CSM-A-M5-S3 of C&S with suitable capacity of 03 Nos CT's - 01
(viii) Space for MCCB for future extension -01
(ix) angle iron frame 40x 40x 6 mm for support of panel height as directed by Engr In Charge .
Ditto all as per items Ser No 53 here in before but indoor type & comperising the following:- (Neuclear Medicine Switch Room)
(i) 630 A aluminium bus bar TPN system.
(ii) MCCB 4 Pole 440 volts AC 50 Hz 400 Amps 36 kA, microprocessor based thermal magnetic release Ics-100% Icu100% - 01 No
(iii) Change over switch Off load Open execution 400 Amps 4 Pole, AC 50 Hz 440 Volt -01
(iv) MCCB 4 Pole 440 volts AC 50 Hz 160 Amps 25 kA, microprocessor based thermal magnetic release Ics-100% Icu100% - 01 No
(iv) MCCB 4 Pole 440 volts AC 50 Hz 100 Amps 25 kA, microprocessor based thermal magnetic release Ics-100% Icu100% - 02 No
(v) Indication lamp RYB for phase indication- 01 Set of three
(vi) Intelligent meter with all parameter as specified in Part No- CSM-A-M5-S3 of C&S with suitable capacity of 03 Nos CT's - 01
(vii) Space for MCCB for future extension -01
(Viii) angle iron frame 40x 40x 6 mm for support of panel height as directed by Engr In Charge .
Note for ser Item No- 53to 58: (i) Make for Panel shall be CPRI approved OR CPRI license holder manufectutrer. (ii) Incoming / all outgoing MCCB's shall also be marked/ painted name of feeding to the place.
(iii) Size of LT Panel & Feeder Piller Boxes shall be depand upon the size of items fixing in side the panel/ Feeder Piller Box and suitable working space provided by the contractor.
M&L for cross arms, bracings, supports, clamps, angle iron, flats and back plates febricated from MS structural steel sections including nuts, bolts and washers of suitable sizes including welding, bending (cold or hot), drilling holes for bolts in any shape or size as indicated or directed and inclusive of two coats of aluminum paint over one coat of red oxide primer, complete all as directed.
M& L for danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for LT, 20x15cm size all as specified.
M&L for writing letter or figures( Block, Roman, Italic or indian) n.exc 6 cm by using stickers on panited surface of LT panels in various location in hosp complex as directed . (Note;Each letter or figure, shall be measured seperately as one unit)
M&L for writing letter or figures( Block, Roman, Italic or indian) n.exc 2 cm by using stickers on panited surface of LT panels in various location in hosp complex all as directed(Note;Each letter or figure, shall be measured seperately as one unit)
Supply installation testing and commissioning of straight length of 2500 A aluminium busbar trunking sandwich type of existing make and cat part number with 02 nos of aluminium earth strip of size 50x6 mm all as per site requirement & as directed by Engr In Charge and comfirming to IEC 61439 - 6(2012).
Supply installation testing and commissioning of flat bend of 2500 A having existing part No& 500mmx500 mmm for aluminium busbar trunking sandwich type of existing make and cat part number with 02 nos of aluminium earth strip of size 50x6 mm all as per site requirement & as directed by Engr In Charge and comfirming to IEC 61439 - 6(2012).
Supply & Fix jointing kit for SBA 150N2/2500 Amps all as speicfied and directed.
Supply & fixing joint adopter kit for 2500 amps BBT.
Ditto as per item Ser No 63 herein before but for 1000 amps.
Ditto as per item Ser No 64 here in before but for 1000 Amps
Ditto as per item Ser No 65 here in before but for 1000 Amps( 350x 350mm or 400x 400 mm
Ditto as per item Ser No 66 here in before but for 1000 Amps
Supply in replacement of canopy which shall be 1.6mm thick with Painted RAL-7035, in CRCA Sheet maximum length 1 Meter to 1.5mtr, with following louvers at side for Air circulation and heat dissipation purpose for aluminium busbar sandwich type /Air Insulated type of any rating where as required or as directed.
Taking shut down LT supply , opening of LT cubical panel , cleaning internally & externally, scrapping rusted surface/ preparation complete for painting clean surface of LT panels with 2 coat of synthetic enemalled paint over a coat of primer all as specified and directed
Taking LT supply shutdown, disconnecting electrical connection, taking down existing busbar from its position incl all accessories complete after connecting of suitable size LT cable for uninterrupted power supply all as directed by Engr In Chrage. Note : (i) Contractor shall be responsible for alternate arrangment of LT Supply with suitable capacity of LT cables. No exrtra cost will be given to the contractor.
M& L for fixing of LT busbar trunking in exisiting position after carried out the repairs ie. opening of bus bar trunking by unscrewing cover plate, cleaning with CRC, unscrewing cluster of nut, bolt and washer of bus bar assembly, removing the bus bar, unscrewing the insulators, and painting internally the bus bar cover plates which are in useable condition drilling holes to bus bar, removing of old sleeves, fixing of new sleeves heat shrinkable type (Make Denson or equivalent), fixing of new gasket, gasket to make the system intact IP 54 protection class connecting bus bar, joint plate, butt joint plate and cover plate after screwing with new screws to insulators etc complete including meggering the system before connecting the load to the entire satisfaction after that disconnecting the temporary electrical cable connection and raising the bus bar trunking to the hangers i.e. original position, re-assembling with nut bolt and washer assembly for all electrical, mechanical and earth connection, tightening and testing complete all as specified abd as directed by Engr-In-Charge. Note : (i) If busbar/insulator/ butt joint/ Tap off box are found unserviceable then supply new items ie. aluminium busbar/insulator/ butt joint/ Tap off box will be decided by Engr-in-charge and measured and paid saparately under susequent items in Ser No 3 (i) to 3 (vii). (iii) Contractor shall arrange the fall ceiling if damaged while taking down from the place where the busbar trucking located.
Supply & fixing the following items to made the LT bus bar made in healthy condition & as per ground requirement and all as directed by Engr-In-Charge.
(i) Busbar of 400 Amp rating including insulation complete all as directed.
(ii) Busbar of 600 Amp rating including insulation complete all as directed.
(iii) Busbar of 800 Amp rating including insulation complete all as directed.
(iv) DMC/FRP insulators over head busbar supports, suitable for 200 to 1600 Amps capacity having 4 Nos of slots for holding bus bar with MS locking plate both sides for busbar truncking.
(v) Butt Joint made of aluminium busbar with proper insulation incl nut bolts and washers suitable for 400 capacity busbar trucnking origin from LT panels all as specified and directed by Engr- in-Charge.
(vi) Ditto as per items 3 (v) but for 600 Amps
(vii) Ditto as per items 3 (v) but for 800 Amps
Supply & Fixing LED VAF + PF meter with RS 485, CI 1 50 to 520 Volts AC (96 mmx 96 mm).
S&F fully reflective sign board of size 1200 x 900 mm, made out of SS sheets of 18 guage surrounded by 80mm square pipe of grade SS-304 and computer printed letters in radium material of height not exc 30 cm each of any kind like block, Roman, Italic, Indian (approx letters exc 30 and not exceeding 100 in numbers), framed SS pipe embedded in ground 60 cm by making holes 70 cm deep and 150 mm dia fixed with using cement concrete 1:4:8, and 90 cm above GL (up to bottom of Board) including necessary excavation , RFR, removal of surplus soil, for HT Electrical installations whereas directed by Engineer-in-Charge. Note : 1.The rates quoted by the tenderer are also deemed to be included necessary Earth work, PCC etc and nothing extra shall be paid on this account.
S & F of Acrylic Sign board of dimension 300mmx 300mm and thickness not less than 5 mm ,including writing letter of height not exc 8 cm each ( Approx nos of letter exc 30 and not exc 80 of any kind like block, Roma Itlalic, Indian, Stop, Commas, Short line, dashes, hypens, brackets etc as directed by Engr-in-Charge) etc complete
Disconnecting of LT cable from both ends & bringing fault detector mahine with skill tradesmen to detecting the fault by inducing the high potential in LT cable of any sizes and marked the place where fault detected
ACR ENTERPRISES
CHAUHAN ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .