Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹22.2 LAccepted-AOC | L-1 | Accepted-AOC Being Lowest bidder | |
| 2 | L-2₹23.2 L+₹93,860 (4.22%)Rejected-AOC | L-2 | Rejected-AOC Other than lowest bidder | |
| 3 | L-3₹26.3 L+₹4.1 L (18.3%)Rejected-AOC R O H NO 55 SEC D BHARAT NAGAR TALAB TILLO JAMMU 180002 | JAMMU | JAMMU AND KASHMIR | 180002 | L-3 | Rejected-AOC Other than lowest bidder | |
| 4 | L-4₹30.8 L+₹8.6 L (38.6%)Rejected-AOC | L-4 | Rejected-AOC Other than lowest bidder | |
| 5 | L-5₹35.0 L+₹12.8 L (57.5%)Rejected-AOC | L-5 | Rejected-AOC Other than lowest bidder |
Tender Value
₹48.9 L
EMD Value
₹97,900
Closing Date
12 Nov 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Sh Tanuj Bagla, IDSE
GE Kaluchak PIN-900673 C/O 56 APO
REPAIR REPLACEMENT OF MISC EM PLANTS PERIMETER LIGHTS AND EQPT INCLUDING SERVICING OF DISINFECTION PLANTS AND STANDBY SETS AT ZONE B AT MIL STN KALUCHAK UNDER GE KALUCHAK
2024_MES_679625_1
GE/KC-59/2024-25
Open Tender
Support/Maintenance Service
Item Rate
180 days
Kaluchak
Please refer Tender Documents
9 documents required · 9 mandatory
₹500
GE Kaluchak
₹97,900
Yes
14 Jan 2025
15 Oct 2024
14 Nov 2024
15 Oct 2024
12 Nov 2024
29 Oct 2024
Amount
Excavation in trenches not exceeding 1.5 metres wide and not exceeding1.5 metres in depth and getting out in any type of soft/loose soil complete all as specified.
Excavation in trenches n.exc 1.5 metre wide and exc. 1.5m in depth but n.exc 3.0 metre in depths for foundations and getting out in soft/ loose soil complete all as specified and as directed.
Returning, filling in, including spreading , leveling , watering and well ramming in layer not exceeding 25cm each layer all as specified.
Removing excavated material not exceeding 50M and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified.
Sand filling in trenches for cable protection provided with layer 8cm deep before laying of cable and 15 cm after laying including spreading and leveling watering and well ramming in layer not exceeding 25mm thick complete all as specified and directed.
Supply and laying in trenches Sub class ‘B’bricks well burnt locally available for covering to cable laid dry flat ,with width of brick perpendicular to the length of cable complete all as specified and as directed.
Material and labour for PCC 1:3:6 Type C-2 (Using 40 mm grade aggregate as in foundation of pole, stay and filling and mass concrete) including providing necessary form work complete all as specified and as directed
Material and labour for PCC 1:2:4 type B1 using 20 mm grade stone aggregate as in copping of electric pole at site including providing necessary form work complete all as specified and as directed.
Taking down and dismantling old u/s cable of any size complete all as
Supply and laying XLPE insulated, screened PVC bedded, galvanized steel strip or wire armoured, electric power cable (heavy duty) with aluminium conductor rating 1100 volts cross sectional area 25 Sq mm 3.5 core laid in trenches or passing through pipes/ducts or fixed to walls/poles incld taking out old unserviceable under ground cable from excavated trenches /pipes (Earth work, segragating cable cover measured separately).complete all as specified.
Supply and laying XLPE insulated, screened PVC bedded, galvanized steel strip or wire armoured, electric power cable (heavy duty) with aluminium conductor rating 1100 volts cross sectional area 35 Sq mm 3.5 core laid in trenches or passing through pipes/ducts or fixed to walls/poles incld taking out old unserviceable under ground cable from excavated trenches /pipes (Earth work, segragating cable cover measured separately).complete all as specified.
Supply and laying XLPE insulated, screened PVC bedded, galvanized steel strip or wire armoured, electric power cable (heavy duty) with aluminium conductor rating 1100 volts cross sectional area 50 Sq mm 3.5 core laid in trenches or passing through pipes/ducts or fixed to walls/poles incld taking out old unserviceable under ground cable from excavated trenches /pipes (Earth work, segragating cable cover measured separately).complete all as specified.
Supply and laying of LT cable in trenches or on poles / walls, XLPE Insulated screened, PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sq mm, 2 core, ISI marked complete all as specified and directed.
Supply and laying of LT cable in trenches or on poles / walls, XLPE Insulated screened, PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 sq mm, 2 core, ISI marked complete all as specified and directed.
Supply and fix Pole mounted bracket made out of GI pipe 40 mm dia medium grade of length 1.5 mtr with two clamps made out of 40x6 mm with suitable nuts, bolts and washers incld taking down old unserviceable GI bracket from pole complete all as specified and directed
M&L for GI tubing 40mm light grade with all necessary fittings laid in trenches under road crossing fixed on poles, walls under floor for cable protection complete all as specified and directed for 40mm dia.
M&L for of PVC insulated weather prof flat twin core Aluminium cable of size 2.5 Sqmm single core including with PVC conduit of all necessary suitable iron clamp(3 nos), nut and bolts of appropriate size from junction box to street light all as specified. .
Dismentaling &Taking down unserviceable street light fittings LED Fittings/ CFL Fittings,post top lantern,garden light, Pin /Holder type from pole or from Bldgs for repairs including replacement of unserviceable Lamp, holder, integral wiring with appropriate gauge copper conductor and refixing the same after repairs in original position properly using PVC insulation tape or where directed complete including replacement of any spares,cable connections from OH conductors,or from junction boxes to light fitting all as specified and as directed. Note : Spares items such as LED driver and cable etc, will be measured and paid separately under respective items.
S&F LED street light fitting of capacity 60 Watt (Efficacy :120LM/W) made up of pressure die cast aluminium housing with toughened glass cover and high power LED's and secondary lenses with IP66 protection with 10 KV inbuilt surge protector including taking down existing old unserviceable light fittings from the bracket of pole or any other place not more than 8.00 metres height from ground level complete all as specified and directed.
S&F Integral LED street light fitting of capacity 90 Watt (Efficacy :120LM/W) made up of pressure die cast aluminium housing with toughened glass cover and high power LED's and secondary lenses with IP66 protection with 10 KV inbuilt surge protector including taking down existing old unserviceable light fittings from the bracket of pole or any other place not more than 8.00 metres height from ground level complete all as specified and directed.
Supply and fix Integral LED security FLOOD light luminaire 120W LED 230 volts made of pressure die cast aluminium housing with high power LED’s lens & toughned glass IP-66 including GI pipe 50mm ,medium grade ,1.7mtr long mounting bracket and providing fixing clamps ,bolts,nuts of suitable sizecomplete all as specified and as directed.
Supply and fix Integral LED security light luminaire 35W LED 230 volts made of pressure die cast aluminium housing with high power LED’s lens & toughned glass IP-66 suitable for mounting existing bracket of size 32/40mm dia G I pipe, fixing clamps ,bolts, nuts of suitable size as required at site complete all as specified and as directed
Supply and fixing New generation, IP 65 LED post-top lantern family, energy saving, environmental friendly, long life aesthetically designed with symmetrical light distribution, spun aluminium landscape luminaire with high power LEDs as light source. Clear Cover offers bright illumination for different applications complete all as specified and as directed
Supply and fixing in replacement path light LED bollard 7W to 10W in cylindrical shape with opal acrylic diffuser and IP 65 & IK-10 protection with silent observer and giving light, diffuser at the upper portion acts a beacon of path guidance in a landscape enironment fixed on PCC block of size 450x450x600 mm with PCC 1:4:8 type D2 40mm graded all as specified and directed.
S&F Thermoplastic Cable Junction Boxes IP66/67 "weather proof" , for outdoor installation with knockouts for cable entry for streetlight with terminals suitable for 16-25 sqmm cable of Size 155 X 210 X 92 mm incl aluninium busbar and MCB SP 6 amps 1 No, for street light, including necessary clamps for fixing with street light pole, and connecting all incoming and outgoing cables with AL lugs of appropiate sizes complete all as specified and directed.
S&F in replacement LED Driver 60 Watt of Make Bajaj/Equivalent
S&F in replacement LED Driver 90 Watt of Make Bajaj/Equivalent
Repair to Voltage Stabilizer, servo type of capacity 20 KVA to 30 KVA at site including carrying out maintenance check along with the following other repairs: (i) Dismantling of voltage stabilizer by disconnecting incoming & outgoing connections, removing the top cover on site, replacing of consumble spare parts such as gasket, burnt PCBs etc unserviceable parts without lifting core assembly. (ii) Assembling of voltage stabilizer after replacement of unserviceable parts with new serviceable parts as ordered by Engr in Charge. (iii) Fixing of top cover after repair and testing up to entire satisfaction of Engr in Charge. Notes : (a) The parts required to be replaced will be measured and paid separately as 'Supply only' against appropriate item of schedule. However labour element and painting involved in replacement are included in quoted rate against this item. (b) Any minor repairs involved to make the voltage stabilizer functional if notified by the Engr-in-Charge shall be carried out by the contractor without any extra cost to the department. Notes : (a) The parts required to be replaced will be measured and paid separately as 'Supply only' against appropriate item of schedule. However labour element and painting involved in replacement are included in quoted rate against this item. (b) Any minor repairs involved to make the voltage stabilizer functional if notified by the Engr-in-Charge shall be carried out by the contractor without any extra cost to the department.
Servicing and cleaning of oil cooled servo voltage stabilizer of capacity 20 KVA to 30 KVA, 3 phase by transporting to workshop, carefully lifting of core from the tank by opening cover, cleaning of tank, removing of sediments, cleaning of coils/ electric connections, filtration of transformer oil, fixing the core back in the tank, making electrical connections by replacing the consumble spares such as gaskets, rubber oil seals complete etc but other spares as listed here-in-after shall be replaced and cost of spare parts 'Supply only' shall be measured and paid for separately under relevant item, transporting back to work site and reconnectiong with electrical connection, complete all as specified & directed by Eng-in-charge. Note : The parts required to be replaced will be measured and paid separately as 'Supply only' against relevant item of schedule. However labour element involved in replacement are included in quoted rate against this item.
Copper dimmer stat 20A.
Servo motor 3 KG with RC network
Carbon brush 28A with holder
Controlling circuit
Aluminium arm set 28A
Pipe bush
Current collector plate copper
Indicating lamps
Toggle switch
Voltmeter 0-500V
Input output connection busbar with bakelite
Fresh transformer oil for top up
Servicing of DG Set 62.5 KVA of any Make, checking entire system as per manufacturer's catalogue such as checking all parts for serviceeablility, taking down defective parts such as fuel filter assy, by pass filter assembly, lub oil filter assembly, air cleaner assy, flexible hose pipe, coolent etc and replacing the same with same size, make and capacity of parts, draining out the old used burnt engine oil from the sump cleaning all serviceable filters and oil sump with cleaning solution such as petrol/ diesel and refilling new engine oil upto required level and including testing to DG Set to entire satisfaction of Engr-in Charge. Note:- (i) Spare parts/ Engine oil/ check kit/ filter shall be measured and paid for saperately under respective items of BOQ (ii) Minimum 6 months gap/ 200 hrs of run whichever is earlier shall be considered for next service (iii) Repair Guarantee for replaced parts/servicing of DG Set shall be for six month/200 hrs from the date of service.
All as per item No 44 here-in-before but for DG set 40 KVA.
All as per item No 44 here-in-before but for DG set 30 KVA.
All as per item No 44 here-in-before but for DG set 25/20 KVA.
Supply only lubricant oil filter suitable for 62.5 KVA DG set
Supply only lubricant oil filter suitable for 40/50 KVA DG set
Supply only lubricant oil filter suitable for 30/25 KVA DG set
Supply only lubricant oil filter suitable for 20/15 KVA DG set
Supply only fuel filter with set of 'O' Ring for 62.5 KVA DG set.
Supply only fuel filter with set of 'O' Ring for 40/50 KVA DG set.
Supply only fuel filter with set of 'O' Ring for 30/25 KVA DG set.
Supply only fuel filter with set of 'O' Ring for 20/15 KVA DG set.
Supply only air filter inner & outer suitable for 62.5 KVA DG set
Supply only air filter inner & outer suitable for 40/50 KVA DG set
Supply only air filter inner & outer suitable for 30/25 KVA DG set
Supply only air filter inner & outer suitable for 20/15 KVA DG set
Supply only Gasket Set suitable for 62.5 KVA DG set
Supply only Gasket Set suitable for 40/50 KVA DG set
Supply only Gasket Setsuitable for 30/25 KVA DG set
Supply only Gasket Set suitable for 20/15 KVA DG set
Calliberation of FIP complete after replacement of defective worn out parts for DG Set 62.5 KVA (i) bearing bush (ii) plunger spring (iii)pump (iv) delivery valve and spring (v) banjo bolt and benjo (vi)sealing ring (vii) oil seal (viii) gasket (ix) overflow valve etc.
All as per item No 50 here-in-before but for DG set 40/50 KVA.
All as per item No 50 here-in-before but for DG set 30/25 KVA.
All as per item No 50 here-in-before but for DG set 20/15 KVA.
Supply and changing engine oil 15W/ 40, Make: Kirloskar / Castrol/ HP
Supply and fixing only pipe hose flexible with 2 Nos clamps of same size/ model/ capacity as per existing complete all as specified and as directed.
Supply and changing coolent all as specified and as directed. Make: Servo/ Shell/ Castrol/ HP
Supply and changing distilled water in for filling in batteries all as specified and as directed.
S&F in replacement automatic voltage regulator suitable for 15 to 62.5 KVA DG set including connections of AVR with panel with and including PVC insulated multistranded copper wires of suitablesize complete all as specified and as directed. Make: Kirloskar/ Crompton/AE
S&F in replacement maintenance free lead acid battery 12 volts 150 AH complete all as specified and as directed. Make : Exide / Boss/ Amron
S&F in replacement maintenance free lead acid battery 12 volts 90 AH complete all as specified and as directed. Make : Exide / Boss / Amron
S&F in replacement PVC transparent flexible pipe, superior quality, of 10mm dia approximate length 2 RM, tightening the same with two Nos of jublee clips on both ends,complete all as specified and as directed.
Servicing of self starter after disconnecting the same from DG sets, transporting to workshop, opening the same and replacing the defective parts/ winding including testing after repair/servicing and refixing in orginal position of capacity 15 KVA to 40 KVA complete all as specified and directed.
All as per item No 76 here-in-before but of capacity 50 KVA to 62.5 KVA
S&F in replacement on load change over switch, 63 Amp capacity, 3 phase, 4 pole, 415 volts, 50Hz, side handle operated, with and including MS sheet metal enclosure having advance neutral complete all as specified and as directed. Make:- C&S/ Havells/Standard
All as per item No 78 here-in-before but 100 Amp
All as per item No 78 here-in-before but 200 Amp
M&L for servicing/ cleaning of MS diesel tank of DG set 15 KVA to 62.5 KVA by draining out the diesel from tank, cleaning the tank with soap water/ suitable solution and painting the external surface with one coat of synthetic enamel paint of existing colour including repalcement of drain valve, outlet pipe complete all as specified and as directed.
S&F in replacement, indicator lamp assembly (set of three) red, yellow, blue complete all as specified and as directed.
S&F in replacement, battery leads copper conductor single core of length 2 x 1.5m of suitable size for 12volt/ 24volt DC with brass terminal heavy duty complete all as specified and as directed.
S&F in replacement of asbestos rope 20mm dia of good quality for exhaust manifold exhaust pipe complete all as specified and as directed.
Removing the old paint from surface of DG set and alternator upto 62.5 KVA capacity and cleaning the old surface with sand paper and painting complete DG set and panel board including canpoy with synthetic enamel paint (of colour as directed by Engg-in-charge) using spray gun with compressed air and writing the SM No/ MES No, in block letters, with white paint & size of letters n exc 3 cm high complete all as specified and as directed.
S&F in replacement, voltmeter of size 96 x 96mm complete all as specified and as directed.
S&F in replacement, amp meter of size 96 x 96mm complete all as specified and as directed.
Repair/Replacement of battery charger by replacing the worn out and defective items
S&F in replacement, battery charger with auto cut off indicater suitable for 24 volts DC complete all as specified and as directed.
Disconnecting and dismantling the alternator unit of 15/25/30/40/62.5 KVA DG Set from the base plate of the DG set and transporting to workshop for repair, dismantling the unit, further separating the armature from the startor carefully, cutting and taking out the burnt windings of the alternator carefully, cleaning the slots and , duly applying the insulation and assembling the stampings inserting in position in the startor including applying slot insulation and rewinding of the alternator startor winding with super enameled copper conductor of same gauge and same number of turns as that of existing one including replacement of carbon brushes tapping the windings and bringing out the coil conections for production of 3 phase 415 volt 50 HZ AC supply and preheating the windings and applying insulating varnish and drying the windings in oven and assembling the unit and transporting back to installation and fixing on base plate and coupling with the DG set and testing complete all as specified and directed.
Dismentling/ taking down complete radiator assembly of DG set 62.5 KVA and transporation to market for repair by :- (i) Opening the radiator assembly with brazing/ welding for repair/ services. (ii) Cleaning of all water tube with diluted solution of HCL & cleaning with water preasure & removing the sludge and dust from inside the tank by flushing out. (iii) Repair of fins by soldring/ brazing. (iv) Repair of bottom brass water tank by soldring/ brazing. (v) Repair of radiator hose assembly. (vi) Fixing the complete radiator assembly to its orignal position and testing complete
All as per item No 90 here-in-before but DG set 40/50 KVA.
All as per item No 90 here-in-before but DG set 15/25/30 KVA.
S&F in replacement, water temp gauge circular dial complete all as specified and as directed.
S&F in replacement, fan belt suitable for 62.5 KVA DG set complete all as specified and as directed.
All as per item No 81 here-in-before but suitable for 40/50 KVA DG set complete all as specified and as directed.
All as per item No 81 here-in-before but suitable for 30/25 .5KVA DG set complete all as specified and as directed.
Disconnection of electric connection from DG set control penal, dressing of cable including replacement of burnt out aluminium/copper lugs and fixing with new lugs, nuts bolt complete all as specified and as directed.
S&F in replacement, MCCB, three pole, 250 Amp 415 volts, 50 Hz breaking capacity not less than 35 kA with adjustable thermal and adjustable magnetic protection release with spreader links, Ics = 100% Icu complete all as specified and as directed.
All as per item No 98 here-in-before but four pole, 160 Amp breaking capacity not less than 25 kA .
All as per item No 98 here-in-before but four pole, 125 Amp breaking capacity not less than 25 kA .
Supply and Fixing in replacement of Self Starter of Capacity 24 Volt suitable for Kirloskar /Cummins Dg set all as specified and directed by Engineer in Charge.
Supply and Fixing in replacement of Self Starter of Capacity 12 Volt suitable for Kirloskar /Cummins Dg set all as specified and directed by Engineer in Charge.
M&L in repairs to AMF Panel/Control panel of DG Set by replacing following parts and commissioning and testing the panel complete all as specified and directed .
Relay 12 volt 8 Pin
Relay 24 Volt 8 Pin
On Relay Eloctronic Timer
Line voltage Monitoring Relay 3 Phase 415 Volt
Start/ Stop relay 12 Volt
Start / Stop Relay 24 volt
Energy Starting Relay 12 Volt
Repair/Replacement of start/Stop Switch
Replacement of Engine Control Unit
Replacement of solenoid switch
Repair/Replacement of worn out/defective part of Dynamo kit
Taking out old /unserviceable damaged existing steel/concrete poles of any size/length from existing position including necessary excavation and demolition of PCC foundation and removing the same from site complete all as specified and as directed.
Supply, erecting and fixing in proper position steel tubular swaged poles of type 410-SP-31 (9.0 mtr long) complete with CI base plate, finial taper plug, bolts, nuts ,screws and pole cap and inclusive of two coat of aluminium paint over a coat of red oxide primer including preparing the surface all as specified and as directed. ( Note:Excavation ,earth work and PCC shall be measured and paid separately )
Dismantling and taking down mild steel cross arms, bracings, supports, channels,angles,clamps etc from pole structure segregating serviceable portion and keeping in safe custody for reuse at site and removing unserviceable portion from site complete all as specified and as directed.
Dismantling ACSR conductor of any size from LT pole and setting a side the serviceable quantity for reuse and removing the unserviceable quantity from site complete all as specified and as directed.
Dismantling insulators of any size /type and setting a side the serviceable quantity for reuse and removing the unserviceable quantity from site.
S&F New Aluminium conductor, steel reinforced, of any size, type, fixed to poles and stretching properly drawn for overhead lines on poles including binding at site to insulator with suitable size of wire including 15mm dia PVC seperater at equal interval including removing old unserviceable ACSR conductor complete all as specified and directed.
Material and labour for cross arms, bracings, supports clamps and back plates fabricated from structural steel sections incl. nuts, bolts, washers, welding, bending cold or hot drilling holes for bolts in any shape or size as indicated or directed and inclusive of two coat of aluminium paint over a coat of red oxide primer including preparing the surface all as specified and as directed.
Material and labour for Shackle type insulator, porcelain, vitreous white / brown including galvanized mild steel straps (of size 31 mm x 3 mm) washers, insulator bolts ( 12 mm dia) washers and nuts per size of height 75 mm and dia 90 mm for working pressure 1100 Volts all as specified and as directed.
Material and labour for Pin type insulator , porcelain, vitreous white / brown including one galvanized mild steel spindle, two galvanized iron washers and one nut (galvanized iron) , for size of 100 mm height, 65 mm dia for 1100 volts grade insulator all as specified and as directed.
M&L for steel wire rope for high mast lights as per site requirement complete all as specified and directed.
S&F in repairs 11 watts LED aviation light having die cast aluminium housing with red polycarbonate dome for better illumination, integral LED driver, IP 65 protection, operating voltage range 100-270 V AC to be mounted on highmast pole only, with all connected accessories complete all as specified and directed.
Dismantling & Taking down the defective highmast light fittings from high mast pole not less than 16mtr height by mechanically/ manually by removing the unserviceable light fitting from the pole and S&F LED flood light 120 watt -4nos, lumen 20000 with 10KV surge protection inbuilt and reassembling the same pole and refixing at its original location including reconnection with suitable length and size of copper/aluminium as per sxisting and testing/commissioning all as specified and directed
M&L for overhauling of not less than 16 meters height high mast lighting system by degreasing and cleaning of double drum winch, gear box, wire rope, clamps, bobbin arrangement, power tool motor, mechanical torque limiter, lowering the mast head assembly, degreasing and cleaning the pulley, docking arm etc and applying new grease / lubricating oil for all mechanical moving / rotating parts, checking all the electrical parts such as timer panel, all cable connections in control panel, motor, junction box, flood light fittings and aviation obstruction light fitting etc, rectifying the defects, renewing the defective components etc including testing for proper functioning complete all as specified and directed. Note: Replacement of flood light fittings, aviation obstruction light, control cable, steel wire rope, timer panel components and rewinding of motor if required at site will be measured and paid seperately under respective items of Schedule 'A'.
S&F in replacement cable saperator heavy duty made of plastic with PVC clamps heavy duty three phase separator complete all as specified and directed.
Supply, installation, testing and commissioning of CPRI approved, factory made, LT Feeder Pillar Box cubical, Outdoor type, floor mounted double door, 3 phase 4 wire, 50 cycles, 415 Volts. The panel board shall be made of 3.15 thick CRCA sheet for load bearing members and 16 SWG (1.6 mm thick) for doors covers and internal partitions and shall be powder coated both side. Base frame of the panel shall be made of ICMC channel of size 50 x50 x 6mm, duly grouted on platform made of brick work in CM (1:2:4), 15mm thick plastering in CM (1:6) having minimum height of 450mm. The panel shall be provided with separate compartments for each switch gears with hinged door including interlocking with switch gears. The panel board shall be suitable for AC, 415 Volts, 50 Hz, 3 phase, 4 wire supply complete with epoxy insulated 250 Amps rated high conductivity aluminium bus bars, supported with DMC / SMC barriers and coluor coded, prewired with copper cable, the degree of protection is IP-54. the panel shall be complete with instrumentation such as LED phase indicating lamps and CT's, including extended aluminium strip of rating of Incomer and outgoing as per rating of MCCB’s, including aluminium lugs to connect the cable dismantled before etc., and comprising of the following:-
(a) MCCB 200 Amps, 4 pole with breaking capacity 25KA (Adjustable thermal & magnetic release) - 01 (b) MCCB 100 Amps, 3 pole with breaking capacity 25KA (Adjustable thermal & magnetic release) - 05 Nos(Spare) Nos(Incomer) (c) MCCB 63 Amps, 3 pole with breaking capacity 25KA (Adjustable thermal & magnetic release) - 01 Nos(Spare) (d) Digital Volt meter .Make Schneider Cat No DM3210 (e) Digital Ammeter meter .Make Schneider Cat No DM3110 (f) Indicator lamp RYB :01 Set, C&S (g) CT'S 200/5 01 Set Make Legrand
Supply, installation, testing and commissioning of CPRI approved, factory made, LT Feeder Pillar Box cubical, Outdoor type, floor mounted double door, 3 phase 4 wire, 50 cycles, 415 Volts. The panel board shall be made of 3.15 thick CRCA sheet for load bearing members and 16 SWG (1.6 mm thick) for doors covers and internal partitions and shall be powder coated both side. Base frame of the panel shall be made of ICMC channel of size 50 x50 x 6mm, duly grouted on platform made of brick work in CM (1:2:4), 15mm thick plastering in CM (1:6) having minimum height of 450mm. The panel shall be provided with separate compartments for each switch gears with hinged door including interlocking with switch gears. The panel board shall be suitable for AC, 415 Volts, 50 Hz, 3 phase, 4 wire supply complete with epoxy insulated 250 Amps rated high conductivity aluminium bus bars, supported with DMC / SMC barriers and coluor coded, prewired with copper cable, the degree of protection is IP-54. the panel shall be complete with instrumentation such as LED phase indicating lamps and CT's, including extended aluminium strip of rating of Incomer and outgoing as per rating of MCCB’s, including aluminium lugs to connect the cable dismantled before etc., and comprising of the following:-
(a) MCCB 200 Amps, 4 pole with breaking capacity 25KA (Adjustable thermal & magnetic release) - 01 Nos(Incomer) (b) OnLoad Changeover Switch, 200 Amp, 4 pole, 415 volt - 01 Nos(Outgoing) (c) MCCB 100 Amps, 3 pole with breaking capacity 25KA (Adjustable thermal & magnetic release) - 03 Nos (d) MCCB 63 Amps, 3 pole with breaking capacity 25KA (Adjustable thermal & magnetic release) - 01 Nos (e) Digital Volt meter .Make Schneider Cat No DM3210 (f) Digital Ammeter meter .Make Schneider Cat No DM3110 (g) Indicator lamp RYB :01 Set, C&S (j) CT'S 200/5 01 Set Make Legrand
Supply, installing, testing and commissioning LT Outdoor floor mounted Bus Bar box, powder coated, factory made and tested , platform mounted, suitable for 415 Volts 3 Phase and neutral, 4 wire, 50Hz AC supply system of size 750X750X450 MM (HXWXD) having bus bar chamber with insulated electrolytic Aluminium bus bars installed on DMC insulators . The panel shall be both side openable dust and vermin proof, protection class (IP-54) in accordance with IS-2147 and made of 3.15 mm thick CRCA mild steel sheet and mild steel angle iron frame work (made out of 40 mm x 40 mm x 5mm thick and 450 mm long), front & rear opening type with aprons for cable entry, with proper ferrule & cable gland, internal wiring with PVC insulated multistranded copper conductor FRLS cable of adequate size but not less than 1.5 sqmm complete. All steel metal works including frame shall be with anticorrosive coating with seven tank process and finally epoxy polyester powder coating of flint grey shade having instrument chamber with RYB indicator LED lamps. he scope of work also comprising of the following including taking down by disconnection of all incoming and outgoing UG cable and MCCB connections of existing UNSV LT bus bar box and making good the disturbed surface :- (A) Aluminium Bus bar chamber rating : 125 Amps, TPN, 415V (B) Incoming MCCB rating : 63 Amps, 4P, 10 KA - 01 NOTE : (i) Panel wiring for control circuit with copper flexible 1.5 Sq mm & power wiring minimum 4 Sqmm flexible or as per load rating of the feeder pillar box and provision of 300x300x2mm thick danger notice board on front side of the panel doors. (ii) Complete installation with civil work and making necessary incoming and outging connection with proper cable lugs and cable glands is deemed to be included in uit rate quoted by the Contractor. (iii) The final height of the LT panel from the normal ground level shall be 450 mm and necessary civil work included in quoted rate.
M&L Earthing complete with galvanised steel earth plate eletrode size 600 x 600 x 6.00mm thick buried directly in ground vertically in pit of depth not less than 2.25 mtr below normal ground level with top edge of the earth plate not less than 1.5 mtr below normal, ground level connceted to galvanised iron strip 32 x6 mm as earthing lead by means of bolts, nuts, check nuts and washers of GI (or) steel all as shown in electrical palte No. 3 connected to earthing test point and testing on completion with and including necessary excavation and earth work including necessary excavation and earth work including lying soil, earth electrode, earthing lead earth electrode to equipment/sub station/panel etc. adequate quantity of charcoal dust and common salt. test point PCC (1:2:6) type B-1 (using 20mm graded stone aggregate/40mm thick cover reinforced with 6 mm dia TMT bars. 3 Nos both way with 12mm dia round bar handle, GI light grade watering pipe 20mm dia with panel, wire mess all as shown in electrical plate No 3 of SSR part 1 of 2009 and 40mm dia GI light grade pipe for earth lead and protection complete all as specified and directed all as specified directed.
M/S RAJ ENGINEERS (BID ID -3157542)
M/S Chib Engineers (BID ID -3163740)
M/S PRAJAPATI ENGINEERS (BID ID -3163558)
VEE ESS ENGINEERS (BID ID -3157966)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .