| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.4 LAccepted-AOC 274 A 5TH LANE NISHATGANJ LUCKNOW UP PIN 226007 | LUCKNOW | LUCKNOW | UTTAR PRADESH | 226007 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹25.1 L+₹70,064 (2.87%)Rejected-Finance 307 SADAR BAZAR LUCKNOW UP 226002 | LUCKNOW | UTTAR PRADESH | 226002 | L2 | Rejected-Finance Being L2 | |
| 3 | L3₹26.3 L+₹1.9 L (7.60%)Rejected-Finance | L3 | Rejected-Finance Being L3 | |
| 4 | L4₹28.5 L+₹4.1 L (16.8%)Rejected-Finance | L4 | Rejected-Finance Being L4 | |
| 5 | L5₹36.3 L+₹11.9 L (48.9%)Rejected-Finance HN 2 PREETI NAGAR PHASE II FAIZULLAGANJ LUCKNOW UTTAR PRADESH 226020 | LUCKNOW | UTTAR PRADESH | 226020 | L5 | Rejected-Finance Being L5 |
Tender Value
₹38.7 L
EMD Value
₹77,400
Closing Date
21 Oct 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE E/M Lucknow
Garrison Engineer E/M, 36 LBS Marg, Lucknow Cantt, Lucknow (U.P.) PIN 226002
PROVN OF AREA LIGHTING INCL CONNECTED ITEMS AT CERTAIN AREAS OF BS MARG AND HM MARG UNDER GE E/M LUCKNOW
2023_MES_620632_1
GE/EM/LKO/EXT(ELECT)/T-41 OF 2023-2024
Open Tender
Electrical and Maintenance Works
Item Rate
90 days
Lucknow
As per NIT
8 documents required · 8 mandatory
₹500
GE E/M Lucknow
₹77,400
Yes
1 Dec 2023
26 Sept 2023
23 Oct 2023
26 Sept 2023
21 Oct 2023
9 Oct 2023
Amount
Excavation in trenches not exc. 1.5 m wide and not exc 1.5 mtr deep in soft/loose soil for laying / taking up/ taking down of cables and getting out and levelling of bottom suface to required level all as specified and directed by Engineer- in- Charge.
Returning filling in,. Including spreading, levelling,. Watering and well ramming excavated soil in layers not exceeding 25 cm thick all as specified and directed.
Removing excavated soil from site to a distance n. exc 50 mtrs away and depositing where directed at a level n. exc. 1.5 mtr above the starting point all as specified and directed by Engineer-in-Charge.
M&L for providing dry river sand as in sand cushioning below and above cable thickness as specified in SSR to under ground cable including punning down of sand in layer all as specified and directed by Engg-in-Charge. Note: for measurement purpose punned thickness of sand will be consider.
Supply and Laying of bricks well burnt sub class B (old size) laid flat for cable protection width equal to the length of bricks complete all as specified and directed by Engineer-in-Charge.
Boring of hole under road / pavement / hard standing or any other situation by manual means and suitable for passing of GI pipe 40 mm bore and making good both ends all specified and directed
S&F GI Pipe (light grade) with necessary accessories/ fittings for cable protections / pole for crossing of culverts / nallah of 40 mm bore
Material & Laying, jointing and testing LT under ground electric power cable crossed linked polyethylene ( XLPE) insulated, galvanised steel strip or wire armoured, ISI-7098 Marked, with aluminium conductor multi stranded , heavy duty 1100 Volts grade of size 16 sqmm cross sectional area, 2 core ,complete all as specified laid in trenches/ laid under floor or fixed naked with walls / on poles/ in ducts /in GI pipes etc. with and including MS Clamps, nuts , bolts, washers complete all as specified and directed. Note :- Excavation, earth work, sand cushioning, protection bricks/ tiles/ block and pipe shall be measured and paid separately under appropriate items.
Earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below normal ground level surrounded from all sides by 15 cm thick packed layer of charcoal dust and common salt filling in alternate layers and electrode connections by mean of GI wire 4 mm dia by means of bolts, nuts check nuts and washers of GI or steel and connecting to earthing test point, main switch board, testing on completion including PCC cover and frame, PCC (1:3:6) type C-2 as in earthing pit, MS funnel with wire mesh GI pipe 20 mm dia light grade for watering and GI pipe 15 mm dia light grade for the protection of GI wire from earth pit to earth point complete including necessary excavation and earth work in any type of soil, returning, filling in approved soil and disposal of surplus soil to a distance n.exc 50 m all as specified as shown in electrical plate No 5 SSR Part-I. PCC chamber shall be constructed at least one metre away from the earth pit and GI pipe fittings for watering shall be provided up to chamber and cost of the same is deemed to be included in the rate of earthing. Note :- If the desired earth resistance is not found, earthing shall be redone by the contractor at no extra cost to the department.
Supply drawing, connecting and testing 3 core, 1.5 Sqmm PVC insulated and PVC round sheathed` copper conductor (flexible ) industurial cable, 1100 Volts conforming to IS 694 in steel tubular poles from Junction box to street light fitting including providing suitable copper lugs all as specified and directed by Engr-in-charge.
S&F of Cast aluminum heavy pole designer leg and broader designer base finished with polyurethane paint (with prior treatments) diameter of one leg is approx 76 mm outer dia for spigot entry approx 60mm, 03 Nos 'T' shaped bolts with nuts & washers provided for concrete foundation total length of the pole including base and legs not less than 2463 mm , bracket made of fully cast aluminum finished with polyurethane paint (with prior treatments) with square junction having max projection breadth of 625 mm suitable & including two numbers post top lanterns, 02 x post top lanterns made of fully Cast aluminium body finished with polyurethane paint (with prior treatments ) paint with acrylic window cover having approx length 533 mm , breadth 228 mm , suspended mode including 02 Nos x brass holder provided with aluminum cover and fitted with 02 x 20 W LED bulb complete all as specified and directed by -in -Charge.
Note:- 1. Cost of designer pole, bracket , post top fitting including LED bulb as specified above shall have deemed to be incuded in quoted rates. 2. Cost of material and labour for construction of PCC foundation as per manufacturing design for pole including earth work shall have deemed to be included in the quoted rates. 3. Design of pole shall be as per sketch No 1 attached with PS clause on serial page No 43
Supply & fix automatic street light timer panel 5 KW switch using Infrared Sensor based for automatic switching of street lights based on LUX level of natural light. Required illuminance for switching ON is < 30 Lux and for switching OFF > 10 Lux level. The sensor (nature switch) alongwith suitable power contactors, Input (supply) MCB and output (load) MCB(s), support terminals should be enclosed in pole/ wall mountable enclosure made of rust proof, electric shock proof, termite proof and FR graded SMC junction box conforming to IP-54 degree of protection including mounting bracket, cable glands, openable doors with lock complete all as specified & directed by Engr-in-Charge.
M/s Vatsh Raj and co
Prime power system
m/s allied enterprises
Ajanta Associates
ANKIT SHIP REPAIRERS AND SUPPLIERS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .