Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.5 LAccepted-AOC PLOT NO 14 SHIV COLONY KATI GHATI RAJGARH ROAD ALWER RAJ | ALWAR | ALWAR | RAJASTHAN | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹26.8 L+₹3.5 L (14.9%)Rejected-Finance | L2 | Rejected-Finance Being L2 | |
| 3 | L3₹29.8 L+₹6.4 L (27.6%)Rejected-Finance | L3 | Rejected-Finance Being L3 | |
| 4 | L4₹31.5 L+₹8.2 L (35.2%)Rejected-Finance | L4 | Rejected-Finance Being L4 | |
| 5 | L5₹32.4 L+₹9.1 L (38.8%)Rejected-Finance | L5 | Rejected-Finance Being L5 |
Tender Value
₹38 L
EMD Value
₹76,000
Closing Date
16 Feb 2025, 6:00 pmClosed
CWE
CWE HISAR
REPAIR/ MAINTENANCE OF DG SETS STREET LIGHT SIGN BORAD AND ALLIED WORKS OF CITY AREA ALWAR MIL STN
2025_MES_693475_1
CWE/HSR/ALW-64/2024-25
Open Tender
Civil Works
Item Rate
180 days
Alwar
As per Notice Inviting Tender (NIT)
7 documents required · 7 mandatory
₹500
GE ALWAR
₹76,000
11 Mar 2025
16 Jan 2025
18 Feb 2025
16 Jan 2025
16 Feb 2025
30 Jan 2025
17 Jan 2025 - 24 Jan 2025
Amount
Repair and maintenance/ servicing of DG sets of different capacities Located at different pockets at Mil Stn Itarana/city area by carryout the following tasks for following capacities DG sets :- (i) Cleaning of air filters (ii) Checking tightening of all nuts and bolts (iii) Greasing Generator (iv) Checking of batteries, flexible coupling, injectors, thermostats, monitoring functions, compression, turbo charger clearance of bearings, air and water hoses pipings, zinc protective pipes, coupling disc of fuel pump drive, 'V' Belts (v) Lubricate the raw water pump. (vii) Checking and seting of speed governor and engine shut down for proper functioning (viii) Cleaning of crankcase ventilation, cooling water spaces, inter cooler (ix) Checking carbon brushes and starter pinion (x) Checking carbon brushes of generator and lubricating the bearings (xi) Testing of FIP timing by fuel out of method. (xii) Checking of supply & return fuel pipes from fuel tank to engine. (xiii) Self & charging alternator cleaning and testing, checking of working & minor fault remover. (xiv)Testing & checking of AC & DC wirings. (xv) supply and fix of engine oil and lubricating oil as required for dg set of different capacity given below (xvi) Repair/ Rewiring of unserviceable AMF Panel making fully functional all as specified and directed by Engr-in-Charge
400 KVA Make CG Greaves
160 KVA Make Kirloskar/Cummins
125 KVA Make Kirloskar
20 to 62.5 KVA Make-Cummins/Kirloskar/Ashok Leyland/Greaves
7.5 to 15 KVA Make-Kirloskar
Supply and filling in sump / topping up engine oil, multi grade 15W40 / 20W40 in engine or relpacement of engine oil Make :- Indian oil / Hindusthan petrolium / BPCL/ Castrol/Shell complete all as specified and directed by Engineer-in-Charge.
Repairs to exhaust piping including cleaning and replacing asbestos rope 6/12 mm or as required at site
Supplying and filiing of coollent and all as specified and directed by Engineer-In-Charge. Make- Castrol/HP/Ind mobil/ TATA
S & F in replacementof Fuel filter element suitable for diesel engine of following capacities all as specified and directed by Engineer-In-Charge.
160 KVA Make Cummins
125 KVA Make Kirloskar
20 to 62.5 KVA Make-Cummins/Kirloskar/Ashok Leyland/Greaves
7.5 to 15 KVA Make-Kirloskar
400 KVA Make CG Greaves
S & F in replacementof lub oil filter element suitable for diesel engine, of following capacities and all as specified and directed by Engineer-In-Charge.
160 KVA Make Cummins
125 KVA Make Kirloskar
20 to 62.5 KVA Make-Cummins/Kirloskar/Ashok Leyland/Greaves
7.5 to 15 KVA Make-Kirloskar
400 KVA Make CG Greaves
S & F of air filter suitable for diesel engine, of following capacities and all as specified and directed by Engineer-In-Charge.
160 KVA Make Cummins
125 KVA Make Kirloskar
20 to 62.5 KVA Make-Cummins/Kirloskar/Ashok Leyland/Greaves
7.5 to 15 KVA Make-Kirloskar
400 KVA Make CG Greaves
S & F in replacement of 'V' belt suitable for diesel engine, of following capacities and all as specified and directed by Engineer-In-Charge.
160 KVA Make Cummins
125 KVA Make Kirloskar
20 to 62.5 KVA Make-Cummins/Kirloskar/Ashok Leyland/Greaves
7.5 to 15 KVA Make-Kirloskar
400 KVA Make CG Greaves
S & F of exhaust silencer suitable for DG set of any capacity as requireddiesel engine and as specified and directed by Engineer-In-Charge.
Supplying and filling of distilled water and all as specified and directed by Engineer-In-Charge.
M&L for scraping the peeled oil Paint on DG set of following capacity including alternator, engine and fuel tank, preparing the surfaces, cleaning the dust, dirt and applying the two coat of synthetic enamel paint of approved shade all as directed by Engineer-In-charge.
160 KVA Make Cummins
125 KVA Make Kirloskar
20 to 62.5 KVA Make-Cummins/Kirloskar/Ashok Leyland/Greaves
7.5 to 15 KVA Make-Kirloskar
S & F in repair fuel pipe hand feed pump to fuel suitable for diesel engine, of following capacities and all as specified and directed by Engineer-In-Charge.
160 KVA Make Cummins
125 KVA Make Kirloskar
20 to 62.5 KVA Make-Cummins/Kirloskar/Ashok Leyland/Greaves
7.5 to 15 KVA Make-Kirloskar
400 KVA Make CG Greaves
M&L for servicing of self starter 12/24 volts DC from DG set, dismantling complete and replacement of solonide field coil
M&L for in replacement, turbo kit of DG Set of following capacities:-
160 KVA Make Cummins
125 KVA Make Kirloskar
20 to 62.5 KVA Make-Cummins/Kirloskar/Ashok Leyland/Greaves
7.5 to 15 KVA Make-Kirloskar
400 KVA Make CG Greaves
Repairs of radiator assembly by dismantling from engine and removing the sediments and scales, corrosion etc by means of descaling chemical cleaning and high pressure water washing and air cleaning, gas welding / soldering with good quality material for stopping the leakage etc, re-assembling the same with new gaskets, fixing to the engine with hoses, clips complete to the entire satisfaction of engineer-in-charge as required for following capacity DG sets:-
160 KVA Make Cummins
125 KVA Make Kirloskar
20 to 62.5 KVA Make-Cummins/Kirloskar/Ashok Leyland/Greaves
7.5 to 15 KVA Make-Kirloskar
400 KVA Make CG Greaves
M&L for rewinding of alternator field coil with super enamelled copper winding wire insulated complete of suitable size of copper wire with following DG set:-
20 to 400 KVA Make-Cummins/Kirloskar/Ashok Leyland/Greaves
7.5 to 15 KVA Make-Kirloskar
M&L for rewinding and refixing of armature winding with super enamelled copper winding wire insulted complete of suitable size of copper wire with following DG sets
20 to 400 KVA Make-Cummins/Kirloskar/Ashok Leyland/Greaves
7.5 to 15 KVA Make-Kirloskar
M&L for alternator bearing suitable for following capacity DG sets, all as specified and directed.
160 KVA Make Cummins
125 KVA Make Kirloskar
20 to 62.5 KVA Make-Cummins/Kirloskar/Ashok Leyland/Greaves
7.5 to 15 KVA Make-Kirloskar
400 KVA Make CG Greaves
S&F in repair of engine start relay, 12/24 V DC for Gen Set 3 cranks on & off 0-30 sec each stable
M&L for repair/overhauling of self starter ic, replacement of carbon brushes, bearing, bushes, rewinding of armature and field etc and warnishing complete all as directed of the following capacity:-
12 Volts
24 Volts
S&F battery lead with brass terminals for 7.5 to 400 KVA DG set complete,
S&F in repair, replacement of self charging maintenance free bty of 12V, DC 150-180 Ah.of existing make and size. Make: exide,amron,luminous
S&F in repair, replacement of self charging maintenance free bty of 12V, DC 120-130 Ah.of existing make and size Make: exide,amron,luminous
S&F in repair, replacement of self charging maintenance free bty of 12V, DC 88-90 Ah.of existing make and size Make: exide,amron,luminous
M&L for calibrating of diesel engine by disconnecting, dismantling of FIP, injector nozzles including connected accessories and refixing after required repairs, etc. complete all as specified and as directed. Notes: (i) Injector nozzle, plunger, delivery valves only if found unserviceable and are replaced for proper functioning, (Ii) All any other items required for making the FIP serviceable shall be deemed to be included in the quoted rate
160 KVA Make Cummins
125 KVA Make Kirloskar
20 to 62.5 KVA Make-Cummins/Kirloskar/Ashok Leyland/Greaves
7.5 to 15 KVA Make-Kirloskar
400 KVA Make CG Greaves
M&L for repair/overhauling of battery charging alternator 12/24 Volts, replacement of carbon brushes, bearing, bushes, rewinding of armature and field etc and warnishing complete all as directed of the following capacity:-
160 KVA Make Cummins
125 KVA Make Kirloskar
20 to 62.5 KVA Make-Cummins/Kirloskar/Ashok Leyland/Greaves
7.5 to 15 KVA Make-Kirloskar
400 KVA Make CG Greaves
Supply & fix Hose pipe set & Clips of water / coolant cooled radiator system etc all as specified and as directed
160 KVA Make Cummins
125 KVA Make Kirloskar
20 to 62.5 KVA Make-Cummins/Kirloskar/Ashok Leyland/Greaves
7.5 to 15 KVA Make-Kirloskar
400 KVA Make CG Greaves
S&F in repair push button start/stop with NONC, all as specified and as directed
S&F in repair starting key switch in three positions, all as specified and as directed
S&F in repair AVR for suitable DG sets as specified and as directed
S&F in repair power diode for DG sets , all as specified and as directed
S&F in repair oil pressure meter
S&F in repair water temperature meter& RPM meter
S&F in repair oil temperature meter
S&F in repair oil pressure pipe
S&F in repair fuel pressure pipe
S&F in repair DG set gasket set incl head gasket
S&F in repair fuel pipe
S&F in repair 12/24 V DC stop solonoid
S&F in repair 12/24 V DC on line solonoid
M&L for DG set control wiring of existing gauge with lugs and connecting accessories complete all as specified and directed
Material and labour for renewal of Earthing complete with GI earth plate electrode of size 900x600x6mm thick buried directly in ground (earth pit should not less than 4 mtr deep below normal ground level ) with top edge of the plate not less than 2.95 mtr deep below normal ground connected to and included GI earth strip 32mmx 6mm by means of bolts nuts check nuts and washer returning and filling the pits with excaviated vsoil mixing with charcoal 250 kg, crystal salt 200 kg ,magnisiun sulphate of 100 kg and vegitable soil all around the plate up to 350 mm above from top edge of plate and balence portion filling with excaviated soil in layers not exc 25 mm thick 25 mm bore galvanised iron medium grade watering pipe up to top of plate 50mm bore galvanised iron light grade pipe for earth strip protection including all excavation earth work in any type of soil pcc 1;3;6 type c1 ....for chamber of internal size 300mmx 300mmx300mm with 120mm thick wall and 700mmx700mmx150mm thick bed concreat RCC 1:2:4 ,type b1 for precast chamber cover 50mm thick reinforced with welded steel wire fabric orxPM jali (weight not less than 4.00 kg/sqmm) ,funnel,with wire mesh complete all as specied and directed. Note (i) Quoted rate shall be deemed to include for earth strip with protection pipe up to 7.5 M length
S&F radiator fan blade of diesel engine as per required
S&F in repair feed pump kit
Material and labour for renewal of Earthing complete with copper earth plate electrode of size 600x600x3.15mm thick buried directly in ground (earth pit should not less than 4 mtr deep below normal ground level ) with top edge of the plate not less than 2.95 mtr deep below normal ground connected to and included copper earth strip 20mmx 3mm by means of bolts nuts check nuts and washer returning and filling the pits with excaviated vsoil mixing with charcoal 250 kg, crystal salt 200 kg ,magnisiun sulphate of 100 kg and vegitable soil all around the plate up to 350 mm above from top edge of plate and balence portion filling with excaviated soil in layers not exc 25 mm thick 25 mm bore galvanised iron medium grade watering pipe up to top of plate 50mm bore galvanised iron light grade pipe for earth strip protection including all excavation earth work in any type of soil pcc 1;3;6 type c1 ....for chamber of internal size 300mmx 300mmx300mm with 120mm thick wall and 700mmx700mmx150mm thick bed concreat RCC 1:2:4 ,type b1 for precast chamber cover 50mm thick reinforced with welded steel wire fabric orxPM jali (weight not less than 4.00 kg/sqmm) ,funnel,with wire mesh complete all as specied and directed. Note (i) Quoted rate shall be deemed to include for earth strip with protection pipe up to 7.5 M length
S&F controller suitable for 7.5 KVA to 125 KVA DG set, CPCB -I, slilent type as per existing complete all as specified and directed
S&F controller suitable for 160 KVA to 400 KVA DG set, CPCB -I/CPCB-II, slilent type as per existing complete all as specified and directed
S&F in repair/replacement of DG Set Actuator as per capacity of DG Set complete all as directed by Engineer-in-charge.
S& F Battery link lead made out with 25sqmm copper conductor PVC insulated with Bty terminal of +/- terminal 0.3 mtr long
S& F Battery link lead made out with 25sqmm copper conductor PVC insulated with Bty terminal of +/- terminal 1.50mtr long
Dismantling of UNSV self starter of capacity 12/24 volts from engine and shifting to civil workshop for repair/overhauling of the self starter by rewinding of field coil, repair and rewinding of armature and fixing it to the existing place after repairing, complete all as specified and directed by Engr-in-Charge.
Supply and fixing contactor 4 pole 100 Amps, 415 Volts, conforms to IS/IEC 60947-4-1 & IEC 60947-4-1 in and including providing auxilary conactors NO/NC complete all as specified and directed by Engr-in-Charge
Supply and fixing contactor 4 pole 130 Amps, 415 Volts, conforms to IS/IEC 60947-4-1 & IEC 60947-4-1 in and including providing auxilary conactors NO/NC complete all as specified and directed by Engr-in-Charge
Supply and fixing contactor 4 pole 160 Amps, 415 Volts, conforms to IS/IEC 60947-4-1 & IEC 60947-4-1 in and including providing auxilary conactors NO/NC complete all as specified and directed by Engr-in-Charge
Supply and fixing contactor 4 pole 200 Amps, 415 Volts, conforms to IS/IEC 60947-4-1 & IEC 60947-4-1 in and including providing auxilary conactors NO/NC complete all as specified and directed by Engr-in-Charge
Supply and fixing contactor 4 pole 255 Amps, 415 Volts, conforms to IS/IEC 60947-4-1 & IEC 60947-4-1 in and including providing auxilary conactors NO/NC complete all as specified and directed by Engr-in-Charge
Repair & Maintenance of existing canopy of eco friendly DG Set of any capacity, cleaning of internal & external parts, tightening of loose parts, painting of rusted inside area, replacing of unserviceable door locks and keys, replacing of damaged or burned inside sponge insulations, Replacement/Welding of damaged MS hinges suitable for Canopy door etc complete all as specified and directed .
Dismantling the fly wheel coupling between engine and alternator and Supply and replace complete set of rubber bushes, coupling nuts & bolts including proper alignment of engine & alternator for smooth running for DG set of capacity complete all as specified and directed by Engineer-in-Charge
S&F in repair, PCB assy complete with display and update software including wiring work suitable for DG Set of capacity 7.5 to 15 KVA.
S&F in repair, PCB assy complete with display and update software including wring work suitable for DG Se of capacity 15 to 63 KVA.
S&F in repair, PCB assy complete with display and update software including wring work suitable for DG Se of capacity 63 to 160 KVA.
S&F in repair, PCB assy complete with display and update software including wring work suitable for DG Se of capacity 400 KVA.
M&L for servicing of alternator of any make suitable for DG set by opening the end cover, cleaning the dust and rust formed over the terminals, cleaning with CTC liquid, checking of diodes, winding, isolating transformer and AVR panel and applying Dr. beck paint for insulation improvement over the strips/ winding and drying till getting sasfactory insulation resistance complete, refixing the covers including testing complete all as specified and directed.
Supply & fix in repair/replacement MCB 6 to 32 Amps, SP, suitable for 240 volts, 50 Hz, AC all as directed by Engineer-in-charge Make: L&T,Shnider,Havells,Indo Asian.
Supply & fix in repair/replacement MCB 32 Amps, SPN, suitable for 240 volts, 50 Hz, AC all as directed by Engineer-in-charge Make: L&T,Shnider,Havells,Indo Asian.
S&F in repair, MCCB TPN 250 Amps 36 KA complete all as specified and directed by Engineer-in-charge.Make : L&T,shnieder,Legrand/ Havells
S&F in repair, MCCB TPN 160 Amps 36 KA complete all as specified and directed by Engineer-in-charge.Make : L&T,shnieder,Legrand/ Havells
S&F in repair, MCCB TP 125 Amps 16 KA complete all as specified and directed by Engineer-in-charge. Make : L&T,shnieder,Legrand /Havells
S&F in repair, MCCB TP 25 to 100 Amps 16 KA complete all as specified and directed by Engineer-in-charge. Make : L&T,shnieder,Legrand/ Havells
Supplying, Fixing, jointing and testing OFF LOAD change over switch 4 pole, 415 volts of current rating 100 Amps. Make ABB / L & T / C&S / Havells
Description all as per item No. 45 above but of current rating 200 Amps
M&L in repair Flexible rubber coupling star type alongwith accessories suitable for Dg set of capacity 20 to 50 KVA
M&L in repair Flexible rubber coupling star type alongwith accessories suitable for Dg set of capacity 62.5 to 100 KVA
M&L in repair Flexible rubber coupling star type alongwith accessories suitable for Dg set of capacity 125 to 400 KVA
M&L for shifting of DG set of any capacity by means of dismantling and lifting and transportaion, including all required T&P such as lifting crane etc and transporting to plant and installation including PCC platefarm structure as required for DG set capacity all as specified and directed.
Supply, laying XLPE insulated PVC FRLS, screened , PVC bedded and PVC tape sheathed galvanised steel strip or wire armoured electric power cable (heavy duty) 1100 volts grade with stranded aluminium conductor of size 4 core 10 Sq mm including taking out old un-serviceable cable complete all as specified and directed.
Description all as per item No 76 but for Cable size 4 core 16 Sq mm
Description all as per item No 76 but for Cable size 4 core 25 Sq mm
Description all as per item No 76 but for Cable size 3.5 core 50 Sq mm
Description all as per item No 76 but for Cable size 3.5 core 70 Sq mm
Description all as per item No 76 but for Cable size 3.5 core 95 Sq mm
Description all as per item No 76 but for Cable size 3.5 core 120 Sq mm
Excavation in trenches not exc 1.5 m in depth and not exc 1.5 m wide for taking out/laying LT UG cable, Stay wire and LT pole/post holes etc and getting out in hard/disintegrated layer complete all specified/directed
Removing excavated soil at a distance not exc 50 m and deposited where directed complete all as directed
Returning,filling in including spreading, leveling, watering and well ramming in layers not exc 25 cm complete all as directed
Supply & laying sub class B bricks, locally available un-burnt bricks suitable for LT cable protection cover all as specified and as directed by Engineer-in-Charge
M &L local river sand for bedding ang sand cushioning of all LT UG cable all as specified and directed by Engr-in-Charge
supply and fix of ^lithium based Energy Efficient Integrated solar street light of 40 watt ^ in single FRP body with duly polyurethane coating(camouflage colour),encases with monocrystalline solar PV panel of 65-67 Wp ,lithium battery 11.1/12.8 v 33 AH with inbuilt BMS IP 65 high brightness W-LED (160/180 lm /watt) lamp with aluminium reflector for better light distrubtion CRI>70 colour temperature 5700-6500K . microcontroller basedcharge controller cum driver automatic diming function (frist four hour at full brightness and rest of the time at lower light level with PIR motion sensor dusk to dawn operation sutiable to working temperature -10 to 55 C .weight not more than 14-16 kg with adjustiable MS clamp sutiable for pole wall mounting etc complete as requirer protection-short circuit overload reverse polarity and battery protection firm should provide vital parameter test report from NABL accredited lab and should be made in india with CE and ROHS complaint Make-Axxon/crompton/bajaj
M&L for painting aluminium coat over Steel tubular pole and cross arms any size and height including preparration of metallic surface with sand papers and applying one coat of metallic primer before applying two coat of aluminium paint all as specified and as directed by Engineer-in-Charge
S&F glow sign board of white polished transparent acrylic cover of minimum 2mm thick, unbreakable, heat resistive etc including M&L of steel fabrication of angles and supports of thickness not less than 2mm thick (thickness shall be variable upto 5mm as per site conditions) rectangular box type of size minimum 180cm x 90cm x 20cm thick, computerised letter of blue colour of size 30cm high and 3 to 5cm width or small as per site requirement having glue on backside to stick permanently, including all kind of securing, welding, assembling with proper allignment and height with fine look, including PCC, cement work, excavation if required, LED tube light fittings 1x 20Watt(6 NOS), including light point 2.5 sqmm (up to 15 m length as required)and switch independent one way 15Amp suitable for exposing at all weathers including taking down of old UNSV sign board etc complete all as specified and as directed by Engineer-in-Charge.
S&F glow sign board of white polished transparent acrylic cover of minimum 2mm thick, unbreakable, heat resistive etc including M&L of steel fabrication of angles and supports of thickness not less than 2mm thick (thickness shall be variable upto 5mm as per site conditions) rectangular box type of size minimum 400cm x 60cm x 20cm thick, computerised letter of blue colour of size 30cm high and 3 to 5cm width or small as per site requirement having glue on backside to stick permanently, including all kind of securing, welding, assembling with proper allignment and height with fine look, PCC(up to 1 cum), cement work,putti and paint excavation if required, LED tube light fittings 1x 20Watt(10 NOS), including light point 2.5sqmm and switch independent one way 15Amp up to 15 m length as reuired all as specified suitable for exposing at all weathers including taking down of old UNSV sign board etc complete all as specified and as directed by Engineer-in-Charge.
S&F in repair LED street light fittings with excellent thermal management of 90 Watt IP-65 with complete accessories on MES installation bldgs at itarana cantt including taking down the old UNSV street light and connecting up the lights to the nearest point by using 1sqmm copper wire 2 run(up to 15 m) and including brackets 1.2 m and clamps 25x4 mm with nut bolts and washer , drilling holes on stone masonry etc complete all as specified and as directed by Engineer-in-Charge.
M & L replacement in repair for PVC insulated and sheathed weather proof two core 2.5 sqmm single stranded aluminium conductor service cable for connection all complete as specified and directed incl taking down UNSV cable. Make Polycab/ Havells
M & L replacement in repair for PVC insulated and sheathed weather proof two core 4 sqmm single stranded aluminium conductor service cable for connection all complete as specified and directed incl taking down UNSV cable. Make Polycab/ Havells
M & L replacement in repair for PVC insulated and sheathed weather proof two core 6 sqmm single stranded aluminium conductor service cable for connection all complete as specified and directed incl taking down UNSV cable. Make Polycab/ Havells
Supply and fixing in replacement of unserviceable garden lights with LED landscape luminaires 10 Watts pressure die cast powder coated housing with PC diffuser,Efficient high output COB for garden, Pathway lightning, IP 66 protection complete all as specified and directed.
S&F in replacement of unserviceable 35W LED Post top made in cast aluminium spigot housing with decorative opal acrylic diffuser and IP65 protection complete with all accessories suitable for connection of copper wires complete all as specified and directed. Make : Crompton, Model - Maple, Cat Part No.: LPT0 - 40 - CDL, 40W LED or Equivalent type in Bajaj / Havells/ Philips / Wipro
Supply and fixing in replacement reflection tape in alternate coloured (04 Step) of width 6" on LT/HT poles between 1.5 to 1.8 Mtr above the ground level all as directed.The tape colour shall be as directed by Engr-in-charge.
Supply and fix in replacement Intelligent, flexible & smart outdoor lighting control unit for automatic switch ON at dusk automatic switching OFF at Dawn with Astronomical Time Switch, high voltage and low voltage protection, 3 Pole / 230V For 12 KW load equally distributed over 3 phases. Minimum IP54 Degre of Protection. Make - IndoAsian, Model - TimeLite, Cat Ref TL065AS0 or Equivalent as Approved by GE.
Supply and fixing in replacement of U/S flood light luminaire of HPSV/MH,with LED flood light fitting consist of PDC aluminium houseing in powder coated dia costing power coted in gray finish,high power LED with IP 66 protection, fins are provided on housing ,heat resistant tempered glass for protection with 5 kv surge protection of 150 W LED as specified and directed.
Supply and fixing in replacement of U/S flood light luminaire of HPSV/MH,with LED flood light fitting consist of PDC aluminium houseing in powder coated dia costing power coted in gray finish,high power LED with IP 66 protection, fins are provided on housing ,heat resistant tempered glass for protection with 5 kv surge protection of 120 W LED as specified and directed.
Disconnection of street light fittings and refixing,Material and labour in replacement for circuit /sub main wiring from junction box to street light fitting complete with 1.5 sqmm 3 core PVC insulated and PVC round sheathed multistranded copper conductor flexible industrial cable 1100 V grade drawn through PVC conduit in street light poles complete all as specified and directed. NOTE :- Cost of Necessary tools and plants such as ladders, hydra for connection to street light fittings etc should be deemed to be included in the unit rate quoted.Make:- Finolex/Havells/Polycab
LT Cable junction box outdoor shall be made out of Polycarbonate with glass fiber reinforced and size should be not less than 225mm x 295mm x 122 mm(upto Cable Size 35/50sq.mm). The Polycarbonate Junction Box shall be environment friendly, recyclable, halogen & silicon free, anti acid & anti corrosive. The Junction Box shall be rated for Degree of ingress Protection IP 66/69 in accordance with IEC 60529.Weatherproof, UV-resistant, rainwater-proof, temperature-resistant. The gasket material of junction box shall be Polyurethane and the gasket shall be internally embedded. The Junction Box shall be complies with requirements of the standards IEC 60998 - 1, IEC 60670 - 22 & IEC 60670 - 2 - 5. The Junction Box with Connectors or Terminal Trip or Bus Bar. The manufacturer of Junction Box / Enclosure shall submit a copy of IEC Certificate . For better safety the Polycarbonate enclosure and shall be fire retardant & self - extinguishing in accordance with IEC 60695 - 2 - 11, DIN VDE 0304 Part - 3, UL Subject 94 for Flammability V-2. It should be tested at Glow Wire test for 960 degree Centigrade & Current Carrying Capacity upto 102Amps. The impact strength of Polycarbonate enclosure / boards i.e. the Degree of protection against mechanical load shall be in accordance with EN 50298 - 98 for IK 08 including one No. 4 pole connector and one no. MCB SP 'B' curved 6-32 Amp and chromium plated clamps and nut bolts, Glands complete all as per manufacturer’s instructions. Make : Cat Part :- KF 3500 B of Hensel/Siemens/GE Power/Rittal or equivalent.
Material & Labour in rectification of LT cable/street light fault, fault existing / as and when occurs with diagonising equipments as applicable, and by joining with suitable LT cable joint kit. Note: (a) Diagonising equipments, Skilled labour, Machinaries for excavation and refilling earth work are to be provided / arranged by the contractor at his expenses. (b) If LT cable fault occurs in Road crossing then Road cut surface to be made good after rectification work. (c) GI pipe utilized fo cable protection under Road/ Over wall will be measured and paid separately.(d) SPD and driver for LED street light utilized for repair will be measured and paid separately
Supply only surge protector 10 kA with IP 65 protection, as per IS
Supply only driver suitable for 45 watt LED with IP 65 protection, as per IS
Supply only driver suitable for 60 watt LED with IP 65 protection, as per IS
Supply only driver suitable for 90 watt LED with IP 65 protection, as per IS
Supply only driver suitable for 120 watt LED with IP 65 protection, as per IS
Supply only driver suitable for 150 watt LED with IP 65 protection, as per IS
Note for above item: - (i) Contractor should depute Electrician and helper and other required equipments such as transportation,hydra,minor excavation etc to attend the Faults / Complaints on daily basis as per complaint trace out and no extra payment will be made out on this account and as directed by Engineer-in-charge. (ii) Contractor / Supervisor will collect complaint of Electric faults,cable faults,Security light faults,No light faults from concern JE on daily basis and will complete them the same day. (iii) Contractor should provide equipments like Excavation Tools, Discharge rod, Tester, Test lamp, Multi meter, Side plier & related essential tools, Industrial Safety helmet, Hand gloves,safety materials etc on his own arrangement as per site requirement for rectifying the complaint and no other payment will be made for the same.
Supply and fixing energy efficient LED street light fitting of 45 Watt , epoxy powder coated pressure die cast aluminium housing to act as heat sink for efficient dissipation of heat and toughened glass with IP 66 degree of protection, system luminous efficency more than 100 lumens / watt individual LED's should have lenses for better throw across and along road, PF>0.9 with voltage range 140 to 270 Volt, fitting should be provided wih inbuilt 10 KV minimum surge protection, short circuit and over voltage protection facility for Driver and fiiting including making electrical connection all as directed by Engr-in-Charge including bracket of suitable size upto 1.5 mtr long & MS Flat clamp of suitable size. Make- Polycab/ havells/ Halonix/ Crompton/ C & S
Supply and fixing of 45watt Inverter LED Street Light with IR Sensor for automatic On-Off of street light and shall have inbuilt Li-on battery for 90mins power backup in case of power failure. Housing of fixture shall be presurre die cast and system efficacy >100LPW, CRI >70, CCT 5700K, PF>0.9, THD<15%. Make: Halonix Cat. Ref. HLSLD-ML04-45-CWL-INV-DIMM-IRSEN-R or equivalent
Supply and fixing energy efficient LED street light fitting of 60 Watt , epoxy powder coated pressure die cast aluminium housing to act as heat sink for efficient dissipation of heat and toughened glass with IP 66 degree of protection, system luminous efficency more than 100 lumens / watt individual LED's should have lenses for better throw across and along road, PF>0.9 with voltage range 140 to 270 Volt, fitting should be provided wih inbuilt 10 KV minimum surge protection, short circuit and over voltage protection facility for Driver and fiiting including making electrical connection all as directed by Engr-in-Charge including bracket of suitable size upto 1.5 mtr long & MS Flat clamp of suitable size. Make- Polycab/ havells/ Halonix/ Crompton/ C & S
Supply and fixing contractor 4 pole 500 AMPS, 415 Voltas, Conforms to IS/IEC 60947-4-1 & IEC 60947-4-1 in and including providing auxilary contractors NO/NC complete all as specified and directed by Engr-in-Charge
Anshu electrical and works (BID ID -3228879)
DEMROT ELECTRICAL WORKS (BID ID -3235570)
ARUN ENTERPRISES (BID ID -3235562)
M/S GAURI CONSTRUCTION (BID ID -3241105)
J.P. Enterprises (BID ID -3240295)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .