Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹25.3 LAccepted-AOC | L-1 | Accepted-AOC Lowest Bidder | |
| 2 | L-2₹29.8 L+₹1.5 L (5.14%)Rejected-Finance | L-2 | Rejected-Finance Other than lowest bidder | |
| 3 | L-3₹34.3 L+₹5.9 L (20.8%)Rejected-Finance | L-3 | Rejected-Finance Other than lowest bidder | |
| 4 | L-4₹34.6 L+₹6.2 L (21.9%)Rejected-Finance | L-4 | Rejected-Finance Other than lowest bidder | |
| 5 | L-5₹35.8 L+₹7.4 L (26.0%)Rejected-Finance | L-5 | Rejected-Finance Other than lowest bidder |
Tender Value
Refer Docs
EMD Value
₹90,000
Closing Date
23 Apr 2022, 6:00 pmClosed
GE Jammu
GE Jammu c/o 56 APO Pin-900277
REPAIR / REPLACEMENT OF INTERNAL WIRING WITH REPLACEMENT OF FITTING AND FIXTURES AND CONNECTED WORKS, CEILING FANS, EXHAUST FANS, DBs SUB MAIN WIRING, METER BOXES AND SERVICE CABLES AT MIRAN SAHIB UNDER GE JAMMU
2022_MES_516597_1
GEJC-03/2022-23
Open Tender
Electrical and Maintenance Works
Item Rate
240 days
AoR of GE Jammu
Please refer Tender Documents
9 documents required · 9 mandatory
₹500
GE Jammu
₹90,000
Yes
30 Jun 2022
5 Apr 2022
25 Apr 2022
5 Apr 2022
23 Apr 2022
18 Apr 2022
Amount
Charges for attending day to day / E/M petty complaint in respect of repair / rectification of fault in electric fitting MCB DB's, internal wiring, LT Panel and fixture and rectify the faults and replacement of unserviceable any type of fitting / fixture, MCB's, any type, bakellite sheet, restore the electric supply and made the item functionable light point, fan point, socket point 5A/15A, switches, sockets, fan regulator, light fixtures any type of lamp, MCB DB's and all electrical accessories and day to day / door to door maintenance, making the points / accessories serviceable in all respect with replacement of any minor parts like small length of wires (not more than 1 metre) and other connected minor accessories. Work shall also include to check and removal of leakage in service connection / submains of houses all as specified and as directed. The scope also include cutting of existing bakellite sheet to accommodate new wiring accessories all type of electric fitting / fixture. Note: - Any other replacement of major items shall be measured and paid under respective items as supply only. Fixing charge of fitting / fixture and MCB's of any type is deemed to be included in the above item.
(a) Contractor representative / Engineer will report to complaint cell for morning and afternoon to collect routine / urgent nature of complaint related to internal electric supply till completion of contract. The work shall be attended by the contractor immediately. The contractor will ensure availability of manpower (Two Electrician and Two Helper) equipped with all sort of petty items such as insulation tape, galvanised screws, nuts, bolts, washers etc required to accomplish the job. The contractor will also ensure the availability of every type of requisite T&P items to his tradesman. All routine / urgent job received on job slip will be repaired and got signatue of user's and will be deposited to complaint cell within 24 hours. In case of any delay in attending the complaint more than 12 hours after handing over of routine / urgent works, the contractor shall be liable to pay the penalty as per the item rate. (b) Contractor shall maintain the maintenance register showing all daily complaints received and shall maintain job card for attending complaints. The signature of the user shall be obtained on the job card showing the materials used in the work after completion of the job. (c) If the Contractor did not attend the complaints, a penalty of Rs 300/- per day per complaint recovery shall be made from the work done amount. (d) The MES Department is not responsible for the payment of staff hired by the contractor for attending complaints. The charges for attending the complaints by the Electrician will be deemed to be included in the item for repair i.e. Electrician / Helper, as all the items of CA are to be supply and fixed by the contractor. (e) Proper record (date wise) of complaints received and rectified by the contractor shall be produced for verification at the time of payment of each RAR / Bill. (f) All the complaint slip, register and connected documents will be provided by the contractor without any extra cost. (g) After any repair the site has to be cleaned and make the surface good.
Supply only switch piano, flush type, single pole, one way 5 Amp, 240 Volts ISI marked complete all as specified and as directed.
Supply only socket outlet 2 in 1, 3 pin, 5 A complete all as specified and as directed.
Supply only switch socket outlet combined 5 pin 5 amp flush type, 240 volts ISI marked complete all as specified and as directed.
Supply only switch socket outlet combined 2 in 1, 3 pin 5 amp and 15 amp flush type, 240 Volts ISI marked complete all as specified and as directed.
Supply only socket outlet 3 pin, 15 Amp, flush type, 240 Volts, 6 pin flush type complete ISI marked complete all as specified and as directed.
Supply only switch piano, flush type single pole one way 15 Amps, 240 Volts ISI marked complete all as specified and as directed.
Supply only ceiling rose 3 terminal surface type complete all as specified and as directed.
Supply only Lamp holder, PVC / Polycarbonate type with back plate suitable for batten fittings complete all as specified and as directed.
Supply only bell, AC 230 Volts single pole complete all as specified and as directed.
Supply only bell push flush type single pole one way 5 amp complete all as specified and as directed.
Supply only holder any type for batten fitting including taking old one ISI marked complete all as specified and as directed.
Supply only MCB SP 6 to 32 Amps, 240 Volt 'B' series complete all as specified and as directed.
Supply only SPN 32 Amp rating 240 V, 10KA 'B' curve miniature circuit breaker (MCB) complete all as specified and as directed.
Supply only SPN 40 to 63 Amp rating 240V, 10KA 'B' curve miniature circuit breaker (MCB) complete all as specified and as directed.
Supply only stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc. as required complete all as specified and as directed.
Taking down old unserviceable copper / aluminium point wiring concealed / batten (light, fan, socket or power) complete, including fixture and fittings such as switches, sockets, ceiling roses, bell push, bell electric, lamp holder, bulk head fitting, pendants, regulators, sockets, light fitting and any type of switch board wooden / iron, round block etc removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc complete all as specified and as directed.
Material and labour for point wiring for one light / fan / call bell point controlled by one 5 Amp switch with 1.5 Sqmm single core multistranded copper conductor FRLS, PVC insulated (unsheathed) heavy duty cable including continuous earth wire of size 1.5 Sqmm copper conductor multistranded FRLS, PVC insulated (unsheathed) drawn into existing concealed PVC rigid / steel conduit and into existing CI / pressed steel terminal boxes including 3.00mm thick hylam brand IS-2036 marked, laminated sheet cover for mounting switches, sockets, fan regulators etc complete all as specified and as directed. Note: - (a) Wiring shall be done by using proper colour coding. (b) Earth wire shall be of green colour. (c) On RCC roof / ceiling PVC conduit shall be provided on surface with proper fixing clamps all as directed by Engineer-in-Charge.
Description same as per Ser Item No 18.00 here-in-before but for one 5 pin socket outlet 5 amps on the same board complete all as specified and as directed.
Description same as per Ser Item No 18.00 here-in-before but for one 5 pin socket outlet, 5 amps, independent complete all as specified and as directed.
Description same as per Ser Item No 18.00 here-in-before but for one 5 pin socket outlet 15 Amps on independent board with cables 2.5 Sqmm size complete all as specified and as directed.
Material and labour for point wiring for one light / fan / call bell point controlled by one 5 Amp switch with 1.5 Sqmm single core multistranded copper conductor FRLS, PVC insulated (unsheathed) heavy duty cable including continuous earth wire of size 1.5 Sqmm copper conductor multistranded FRLS, PVC insulated (unsheathed) drawn into and including new concealed PVC rigid / 1.8mm wall thickness ISI marked including new CI / pressed steel terminal boxes including 3.00mm thick hylam brand IS-2036 marked, laminated sheet cover for mounting switches, sockets, fan regulators etc complete all as specified and as directed. Note: - (a) Wiring shall be done by using proper colour coding. (b) Earth wire shall be of green colour. (c) On RCC roof / ceiling PVC conduit shall be provided on surface with proper fixing clamps all as directed by Engineer-in-Charge.
Description same as per Ser Item No 22.00 here-in-before but for 5 Amp socket outlet on same board complete all as specified and as directed.
Description same as per Ser Item No 22.00 here-in-before but for socket outlet 5 Amps independent board complete all as specified and as directed by Engineer-in-Charge.
Description same as per Ser Item No 22.00 here-in-before but for one 6 pin socket outlet 15 Amps on independent board with cables 2.5 Sqmm size complete all as specified and as directed.
Description same as per Ser Item No 22.00 here-in-before but drawn through and including new surface conduit PVC rigid non-metallic conduit 20 mm dia for socket outlet 5 amp independent board complete to accomodate the accessories for PVC Gang Box complete all as specified and as directed.
Description same as per Ser Item No 22.00 here-in-before but drawn through and including new surface conduit PVC rigid non-metallic conduit 20 mm dia for socket outlet 15 amp independent board complete to accomodate the accessories for PVC Gang Box complete all as specified and as directed.
Material and labour for point wiring for one light / fan / call bell point controlled by one 5 Amp switch with 1.5 Sqmm single core multistranded copper conductor FRLS, PVC insulated (unsheathed) heavy duty cable including continuous earth wire of size 1.5 Sqmm copper conductor multistranded FRLS, PVC insulated (unsheathed) drawn into and including new concealed PVC rigid / 1.8mm wall thickness ISI marked including pressed steel with existing colour terminated boxes of modular metal flush boxes of any way i.e. (1 to 8 way as per site requirement) for mounting switches, sockets, fan regulators etc complete all as specified and as directed for the following: - Note: - (a) Suitable module white cover sheets with frame as specified to be provided in replacement to MS / Galvanised sunken boxes and shall be measured and paid separately as per relevant item. (b) Wiring shall be done by using proper colour coding. (c) Earth wire shall be of green colour. (d) On RCC roof / ceiling PVC conduit shall be provided on surface with proper fixing clamps all as directed by Engineer-in-Charge.
Description same as per Ser Item No 28.00 here-in-before but for 5 Amp socket outlet on same board complete all as specified and as directed.
Description same as per Ser Item No 28.00 here-in-before but for socket outlet 5 Amps independent board complete all as specified and as directed by Engineer-in-Charge.
Description same as per Ser Item No 28.00 here-in-before but for one 6 pin socket outlet 15 Amps on independent board with cables 2.5 Sqmm size complete all as specified and as directed.
Supply and fixing in replacement modular switch 1 way 6 A, 1 module, 240 volts ISI marked complete all as specified and as directed.
Supply and fixing in replacement modular switch 1 way 16 A, 1 module, 240 volts ISI marked complete all as specified and as directed.
Supply and fixing in replacement socket, 6A - 2/3 pin combined 2 module, 240 volts ISI marked complete all as specified and as directed.
Supply and fixing in replacement socket 6A / 16A - 2/3 pin combined 2 module, 240 volts ISI marked complete all as specified and as directed.
Supply and fixing in replacement fan step regulator, 120W 1 module, 240 volts ISI marked complete all as specified and as directed.
Supply and fixing in replacement modular metal flush box 1/2 module, 240 volts ISI marked complete all as specified and directed.
Supply and fixing in replacement modular metal flush box 3 module, 240 volts ISI marked complete all as specified and as directed.
Supply and fixing in replacement modular metal flush box 4 module, 240 volts ISI marked complete all as specified and as directed.
Supply and fixing in replacement modular metal flush box 6 module, 240 volts ISI marked complete all as specified and as directed.
Supply and fixing in replacement modular metal flush box 8 module, 240 volts ISI marked complete all as specified and as directed.
Supply and fixing in replacement modular white cover plate with frame 1 module, 240 volts ISI marked complete all as specified and as directed.
Supply and fixing in replacement modular white cover plate with frame 2 module, 240 volts ISI marked complete all as specified and as directed.
Supply and fixing in replacement modular white cover plate with frame 3 module, 240 volts ISI marked complete all as specified and as directed.
Supply and fixing in replacement modular white cover plate with frame 4 module, 240 volts ISI marked complete all as specified and as directed.
Supply and fixing in replacement modular white cover plate with frame 6 module, 240 volts ISI marked complete all as specified and as directed.
Supply and fixing in replacement modular white cover plate with frame 8 module, 240 volts ISI marked complete all as specified and as directed.
Material and labour for replacement of distribution board sheet steel powder coated for MCB with copper bus bar and neutral link earthing stud SPN 12 way 240 volts double door complete all as specified and as directed by Engineer-in-Charge. Note: - Distribution board and MCB's should be of same make.
Material and labour for replacement of distribution board sheet steel powder coated for MCB with copper bus bar and neutral link earthing stud SPN 8 way 240 volts double door complete all as specified and as directed by Engineer-in-Charge. Note: - Distribution board and MCB's should be of same make.
Material and labour for replacement distribution board sheet steel powder coated for MCB with copper bus bar and neutral link earthing stud SPN 4 way 240 volts double door complete all as specified and as directed by Engineer-in-Charge. Note: - Distribution board and MCB's should be of same make.
Supply and fixing in replacement MCCB 4 pole, 415 Volt fixed thermal and fixed magnetic setting of capacity 125 Amps 16 KA complete all as specified and as directed.
Supply and fixing in replacement 240V, 10 KA 'B' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 5 to 32 Amp, in the MCB DB complete with connection, testing and commissioning complete all as specified and as directed.
Supply and fixing in replacement 240V, 10 KA 'B' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 40 Amp, in the MCB DB complete with connection, testing and commissioning complete all as specified and as directed.
Supply and fixing in replacement SPN 32 Amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the MCB DB complete with connection, testing and commissioning complete all as specified and as directed.
Supply and fixing in replacement SPN 40 to 63 Amp rating 240V, 10KA 'B' curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the MCB DB complete with connection, testing and commissioning complete all as specified and as directed.
Supply and fixing in replacement 415V 10KA 'B' curve TPN 40 to 125 Amp miniature circuit breaker (MCB) of following poles and current carrying capacity in the DB complete with connection, testing and commissioning complete all as specified and as directed.
Supply and fixing in replacement for switch piano, flush type single pole one way 5 Amp, 240 volts complete all as specified and as directed.
Supply and fixing in replacement for switch piano, flush type single pole one way 15 Amp, 240 volts complete all as specified and as directed.
Supply and fixing in replacement socket outlet 2 in 1, 3 pin, 5 A complete all as specified and as directed.
Supply and fixing in replacement socket outlet 5 pin, 15 amp flush type, 240 volts, 6 pin flush type complete all as specified and as directed.
Supply and fixing in replacement switch socket outlet combined 5 pin 5 amp flush type, 240 volts complete all as specified and as directed.
Supply and fixing in replacement switch socket outlet combined 2 in 1, 3 pin 5 amp and 15 amp flush type, 240 Volts complete all as specified and as directed.
Supply and fixing in replacement for bell push, flush type single pole, 5 Amp, 240 volts complete all as specified and as directed.
Supply and fixing in replacement ceiling rose 3 terminal surface type complete all as specified and as directed.
Material and labour in replacement for Lamp holder, PVC / Polycarbonate type with back plate suitable for batten fittings complete all as specified and as directed.
Material and labour in replacement self ballast LED retrofit lamp with PVC body and PC Diffuser 9 watt 230 Volt 6500K complete all as specified and as directed.
Supply and fixing in replacement LED lights fitting 1 x 20W, 220V, AC decorative box type complete with LED tube rod 20 watts driver, holder and power factor >0.95, 100 Lumen / Watt, 6500 K cool day type conforming to ISI including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete (4' ft long) with LED rod 20 watt, 230 Volts 50 Hz complete all as specified and as directed.
Supply and fixing in replacement LED light fitting mirror type with high output diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed.
Supply and fixing in replacement bulk head luminaries IP-65 with opal diffuser 10 watt, 230 Volts LED type complete with 10 watt LED bulb complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing in replacement LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders and LED lamp suitable for roof, ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and as directed.
Supply and fixing in replacement stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc. as required complete all as specified and as directed.
Supply and fixing in replacement calling bell Ding Dong / buzzer AC 230 Volts, single pole complete all as specified and as directed.
Material and labour in replacement for sub main wiring with proper colour coding, insulated, unsheathed, multistranded, copper conductor FRLS, cable of 2 run 6 Sqmm for phase and neutral and one run of 4.0 Sqmm for earth wire unsheathed, multistranded, copper conductor FRLS, drawn through the existing rigid PVC concealed conduit fixed on wall. Two runs of cable for phase / neutral and one run of cable for earth will be measured and paid as one unit length. Note: - Wiring shall be done in proper colour coding.
Material and labour in replacement for sub main wiring with proper colour coding, insulated, unsheathed, multistranded, copper conductor FRLS, cable of 2 run 4 Sqmm for phase and neutral and one run of 2.5 Sqmm for earth wire unsheathed, multistranded, copper conductor FRLS, drawn through the existing rigid PVC concealed conduit fixed on wall. Two runs of cable for phase / neutral and one run of cable for earth will be measured and paid as one unit length. Note: - Wiring shall be done in proper colour coding.
Material and labour in replacement for wiring for circuit with proper existing colour coding, insulated, unsheathed, multistranded, copper conductor FRLS, cable of 1 run 2.5 Sqmm for phase, drawn through the existing rigid PVC concealed conduit fixed on wall including taking down existing unserviceable wiring complete all as specified and as directed. Note: - Wiring shall be done in proper colour coding.
Material and labour in replacement for wiring for circuit with proper existing colour coding, insulated, unsheathed, multistranded, copper conductor FRLS, cable of 1 run 1.5 Sqmm for phase, drawn through the existing rigid PVC concealed conduit fixed on wall including taking down existing unserviceable wiring complete all as specified and as directed. Note: - Wiring shall be done in proper colour coding.
Material and labour in replacement for Earthing complete with galvanised mild steel earth plate electrode of size 600 x 600 x 6mm thick buried directly in ground earth (in vertical) earth pit not less than 2.25 metre deep below normal ground level with top edge of the earth plate not less than 1.5 metre below ground level connected to galvanised iron or earth lead wire 4mm dia (8 SWG) by means of nut, bolt, check nuts and washer of galvanised iron including PCC pit in PCC (1:2:4) type B-1 pre-cast RCC cover slab using reinforcement with suitable handle made of round bar, including necessary excavation and earth work in any type of soil, 20mm dia medium grade galvanised steel tube for watering with one end fixed with cast iron funnel and wire mesh 15mm dia bore light grade galvanised steel tubing upto 5 m length for drawing earth lead wire protection, common salt, charcoal, etc complete all as shown in electrical plate No 3 of SSR Part-I and testing on completion complete all as specified and as directed.
Supply and fixing in replacement unserviceable wooden / CI Sunken box with new CRCA pressed steel terminal box of size 7 X 4' including taking down old complete with cemented and patch work all as specified and as directed by Engineer-in-Charge.
Supply and fixing in replacement unserviceable wooden / CI Sunken box with new CRCA pressed steel terminal box of size 4 X 4' including taking down old complete with cemented and patch work all as specified and as directed by Engineer-in-Charge.
Supply and fixing in replacement unserviceable wooden / CI Sunken box with new CRCA pressed steel terminal box of size 10 X 8' including taking down old complete with cemented and patch work all as specified and as directed by Engineer-in-Charge.
Supply and fixing in replacement Bakellite hylum sheet 3 mm thick complete with cutting and making size for fixing switches (06 No's each) of size 8'' X 5'' all as specified and as directed.
Supply and fixing in replacement Bakellite hylum sheet 3 mm thick complete with cutting and making size for fixing switches (12 No's each) of size 12'' X 10'' all as specified and as directed.
Supply and fixing in replacement Bakellite hylum sheet 3 mm thick complete with cutting and making size for fixing switches (02 No's each) of size 5'' X 5'' all as specified and as directed.
Supply and fixing in replacement plug top 15 Amps complete all as specified and as directed.
Supply and fixing in replacement of Vertical Distribution Board (TP&N) 4 way double door suitable for and including MCCB 125 Amp 16 KA four pole as incomer and outgoing MCB's and should be IP-43 protected with copper bus bars, neutral links, earthing bar all as specified and directed including taking down old unserviceable DB / MCB any type. Note: - (i) Rate includes MCCB four pole 125 Amp, 16 KA, 415 volts with adjustable thermal settings. (ii) MCB's shall be measured and paid separately. (iii) TPN DB and MCCB should be of same make.
Supply and fixing in replacement PVC box (gang box) surface mounted heavy duty 3 way complete with socket outlet 2 in 1, 6 pin, 5 amp 240 volt along with switch piano 5 amp 240 volt complete all as specified and as directed.
Supply and fixing in replacement PVC box (gang box) surface mounted heavy duty 3 way complete with socket outlet 2 in 1, 6 pin, 5 amp 240 volt along with switch piano 15 amp 240 volts complete all as specified and as directed.
Labour for repair / servicing of ceiling fan of any capacity complete with strip opening the ceiling fan for repair / washing / varnishing and removing of old lubricating substance from bearing / bush by using Kerosene oil, carrying out fresh lubrication using grease and to make the ceiling fan noise free for smooth functioning, including replacement of worn out / unserviceable minor spare parts split pin, fan body bolts, spring washer, fan rod bolt etc and PVC insulated, unsheathed stranded twin twisted copper conductor cable of size 1.5 Sqmm up to 1.0 M long, assembling the repaired ceiling fan and testing to the entire satisfication of Engineer-in-Charge and depositing in MES store yard complete all as specified and as directed. Note: - Replacement of spares flexible wire etc / rewinding of ceiling fan shall be measured and paid separately under respective item for material and labour cost.
Labour for repair / servicing of exhaust fan of any type mm sweep complete with strip opening the exhaust fan for repair / washing / varnishing and removing of old lubricating substance from bearing / bush by using Kerosene oil, carrying out fresh lubrication using grease and to make the exhaust fan noise free for smooth functioning, including replacement of worn out / unserviceable minor spare parts split pin, fan body bolts, spring washer, fan rod bolt etc and PVC insulated, unsheathed stranded twin twisted copper conductor cable of size 1.5 Sqmm up to 1.0 M long, assembling the repaired exhaust fan and testing to the entire satisfication of Engineer-in-Charge and depositing in MES store yard complete all as specified and as directed. Note: - Replacement of spares flexible wire etc / rewinding of exhaust fan shall be measured and paid separately under respective item for material and labour cost.
Labour for repair / servicing of wall mounting fan of any size / type complete with strip opening the wall mounting fan for repair / washing / varnishing and removing of old lubricating substances from bearing / bush by using Kerosene oil, carrying out fresh lubrication using grease and to make the wall mounting fan noise free for smooth functioning, including replacement of worn out / unserviceable minor spare parts split pin, fan body bolts, spring washer, fan rod bolt etc and PVC insulated, unsheathed stranded twin twisted copper conductor cable of size 1.5 Sqmm up to 1.0 M long, assembling the repaired wall mounting fan and testing to the entire satisfication of Engineer-in-Charge and depositing in MES store yard complete all as specified and as directed. Note: - Replacement of spares flexible wire etc / rewinding of wall mounting fan shall be measured and paid separately under respective item for material and labour cost.
Rewinding of ceiling fan, of any make / type and size (1200 / 1400mm sweep) with super enamelled copper wire of appropriate gauge as existing to obtain the specified and satisfactory RPM as per manufacturer's specification, including replacement of all insulation materials, varnishing, heating, drying, assembling of stator / rotor, connection and testing complete all as specified and as directed.
Rewinding of exhaust fan, of any make / type and size with super enamelled copper wire of appropriate gauge as existing to obtain the specified and satisfactory RPM as per manufacturer's specification, including replacement of all insulation materials, varnishing, heating, drying, assembling of stator / rotor, connection and testing complete all as specified and as directed.
Rewinding of wall mounting fan, of any make / type and size with super enamelled copper wire of appropriate gauge as existing to obtain the specified and satisfactory RPM as per manufacturer's specification, including replacement of all insulation materials, varnishing, heating, drying, assembling of stator / rotor, connection and testing complete all as specified and as directed.
Labour for remetalling of worn out shaft of fan, cutting, brazing, machining and polishing to make the shaft suitable for fixing of new ball bearing and fixing ball bearing in replacement of bushing system in ceiling fan and assembling the same and testing to the entire satisfaction of Engineer-in-Charge to ensure smooth and noise free operation complete all as specified and as directed. Note: - Bearing shall be measured and paid separately.
Supply and fixing in repair ball bearing of any size and type, suitable for ceiling fan of any type / make / size complete all as specified and as directed.
Supply and fixing in repair ball bearing of any size and type, suitable for exhaust fan of any type / make / size complete all as specified and as directed.
Supply and fixing in repair ball bearing of any size and type, suitable for wall mounted fan of any type / make / size complete all as specified and as directed.
Supply and fixing in replacement of capacitor 230 Volt AC 50 Hz, conforming to IS-1709 and rated capacity 2.5 MFD for ceiling fan, exhaust fan and wall mounted fan complete all as specified and as directed.
Supply and fixing in replacement of capacitor 230 Volt AC 50 Hz, conforming to IS-1709 and rated capacity 4.0 MFD for ceiling fan, exhaust fan and wall mounted fan complete all as specified and as directed.
Supply and connection in repair of PVC insulated, unsheathed, multi-stranded, three core twisted copper flexible cable of size 1.5 Sqmm as required complete all as specified and as directed.
Supply and fixing in repair only bush of suitable size for exhaust fan of any type / size as per existing type complete all as specified and as directed.
Supply and fixing in repair only bush of suitable size for wall mounted fan of any type / size as per existing type complete all as specified and as directed.
Supply and fixing in repair of PVC connector 4 way 6 Amps with connection screws, nuts complete all as specified and as directed.
Supply and fixing in repair of PVC clamps with fixing screws for holding capacitor of any type and size complete all as specified and as directed.
Supply and fixing in repair of GI / MS anodized bolts with anodized nuts, spring washers, split pin etc size 50 mm long 10 mm dia half threaded type with split pin hole complete all as specified and as directed.
Supply and fixing in replacement of MS clamp for down rod of suitable size including gromet / reel type rubber pad with bolts, nuts, split pin and washers suitable for housing ceiling fan complete all as specified and as directed.
Supply and fixing in replacement of ceiling fan down rod 12 mm dia and 30 / 45 cm long complete with MS clamp rubber reel, split pin nut bolts etc complete all as specified and as directed.
Supply and fixing in replacement of louver shutter made out of MS sheet metal 1.2 mm thick for round base and 0.8 mm thick for flaps, comprising of mounting legs, frames made of MS flat strips of size 25mm x 3mm including heavy duty rust proof passivated bolts of size 50 mm long 8 mm dia to be fixed on wall at ground / first / second floor etc complete with using fastener bolt, drilling, spray painting over a coat of primer for exhaust fan up to 400 mm sweep including taking down old one complete all as specified and as directed. Notes: - (i) Rates are deemed to be including charges for hiring any type of T&P ladder, cutter etc. (ii) Contractor shall be responsible for life cover of staff deployed for fixing louver shutter.
Cleaning of ceiling fan assembly of any type / size and carrying out two coats of spray painting with first quality synthetic enamelled paint of approved colour, including writing of MES number in black paint complete all as specified and as directed.
Cleaning of exhaust fan assembly upto 450mm of any type and carrying out two coats of spray painting with first quality synthetic enamelled paint of approved colour, including writing of MES number in black paint complete all as specified and as directed.
Supply and fixing in replacement PVC canopy set of two pieces for ceiling fans of any size complete all as specified and as directed.
Repair to oscillation, moving part of wall mounted fan including replacement of all wornout components, bearing, lubrication and assembling complete all as specified and as directed.
Supply and fixing in repair ceiling fan blade set of three pieces suitable for 1200 / 1400 mm sweep of White / Brown / Ivory colors complete all as specified and directed.
Taking out existing unserviceable / old steel / mild steel angle iron frame of any size from the wall by dismantling bricks and making the surface good complete with brick works, plaster, white wash, patch work matching with existing colour complete all as specified and as directed.
Taking out serviceable electric meter from the panel board after disconnecting all incoming / outgoing connection carefully and refixing the same in position complete all as specified and as directed.
Material and labour for distribution board double door sheet steel phosphatised powder painted for MCB / DB with copper bus bar and neutral link earthing syud TPN 4 way 415 Volts doubled door including taking down old one complete all as specified and as directed.
Material and labour in replacement for sub main wiring with proper colour coding, insulated, unsheathed, multistranded, copper conductor FRLS, cable of 2 run 6 Sqmm for phase and neutral and one run of 6.0 Sqmm for earth wire unsheathed, multistranded, copper conductor FRLS, drawn through the new rigid PVC concealed conduit fixed on wall. Two runs of cable for phase / neutral and one run of cable for earth will be measured and paid as one unit length. Note: - Wiring shall be done in proper colour coding.
Material and labour in replacement for sub main wiring with proper colour coding, insulated, unsheathed, multistranded, copper conductor FRLS, cable of 2 run 4 Sqmm for phase and neutral and one run of 4 Sqmm for earth wire unsheathed, multistranded, copper conductor FRLS, drawn through the new rigid PVC concealed conduit fixed on wall. Two runs of cable for phase / neutral and one run of cable for earth will be measured and paid as one unit length. Note: - Wiring shall be done in proper colour coding.
Supply and fixing in replacement of PVC enclosure DP complete with MCB SPN 32 Amp 10 KA 230 Volt complete all as specified and as directed including taking down old one complete all as specified and as directed.
Supply and fixing in replacement of sheet steel cable and box (bus bar) 4 way 440 Volt, 50 Hz single door with 200 Amp rated bus bar mounted on insulator including taking down old one complete all as specified and as directed.
Supply and fixing PVC flat serviceable cable 10 Sqmm 2 core multistranded conductor 1100 Volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable flat or circular including taking down old one complete all as specified and as directed.
Supply and fix polycarbonate meter boxes and complete enclosure for TPN boxes, DB boxes and meter enclosure, vermin proof, rust proof having locking arrangement complete all as specified and as directed.
Supplying and fixing PVC flat serviceable cable 16 Sqmm 2 core stranded multi conductor 1100 Volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable flat or circular including taking down old one complete all as specified and as directed.
Notes: - (i) For Serial Item No 16 to 87 : The contractor has to complete the work assigned for the above items within 72 hours failing which recovery @ Rs. 25 per complaint per day shall be deducted. (ii) The MES Department shall not be responsible for the payment of staff hired by contractor for complaint rates for attending the complaints by the Electrician are deemed to be included in the item for repair i.e. Electrician / Helper, as all the items of CA are to be supply and fixed by the contractor. (iii) Proper record (date wise) of complaints received and rectified by the contractor shall be produced for verification at the time of payment of each RAR / Bill. (iv) All the complaint slip, register and connected documents will be provided by the contractor without any extra cost. (v) After any repair the site has to be cleaned and make the surface good.
Sarbat Construction Co
G R CONSTRUCTIONS
M/S SALARIA ASSOCIATES
Harsh Electricals
Prakash Trading Corporation
M/s Sahib Construction and engineers
M/s. Aggarwal Engineers
Bidder Name
Prakash Trading Corporation
G R CONSTRUCTIONS
Sarbat Construction Co
M/S Shiv Enterprises
Harsh Electricals
M/s. Aggarwal Engineers
M/s Sahib Construction and engineers
M/S SALARIA ASSOCIATES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .