| 1 | L-1₹24.8 LAccepted-AOC FLAT NO 205 SYNERGY WORLD KOSARA DISTRICT CHANDRAPUR MS 442401 | CHANDRAPUR | CHANDRAPUR | MAHARASHTRA | 442401 | L-1 | Accepted-AOC Lowest qualified bidder. Hence being awarded. | |
| 2 | L-2₹21.8 L+₹86,546 (4.13%)Rejected-AOC | L-2 | Rejected-AOC Not a qualified L1 bidder | |
| 3 | L-3₹23.5 L+₹2.6 L (12.2%)Rejected-AOC NEAR RADHAKRISHNA MANDIR SHASTRINAGAR GHUGUS TAH DIST CHANDRAPUR 442505 | CHANDRAPUR | CHANDRAPUR | MAHARASHTRA | 442505 | L-3 | Rejected-AOC Not a qualified L1 bidder | |
| 4 | L-4₹24.9 L+₹4.0 L (18.9%)Rejected-AOC UTTAM NAGAR BENGALI CAMP MULI ROAD CHANDRAPUR 442401 | CHANDRAPUR | CHANDRAPUR | MAHARASHTRA | 442401 | L-4 | Rejected-AOC Not a qualified L1 bidder | |
| 5 | L-5₹26.2 L+₹5.2 L (24.9%)Rejected-AOC | L-5 | Rejected-AOC Not a qualified L1 bidder |
Tender Value
₹40.1 L
EMD Value
₹50,200
Closing Date
30 Jan 2024, 3:30 pmClosed
Shri. Nitin Naik
OFFICE OF THE AREA GENERAL MANAGER WCL BALLARPUR AREA P.O. SASTI TA. RAJURA DIST. CHANDRAPUR (MS) PIN 442905
Repair of compound wall precast slab on cable water proofing treatment by APP and other misc. Civil works in 66 KV substation of Sasti OCM under Sasti Sub Area
2024_WCL_299150_1
wcl-ba3650-civ-e147-23-24/862
Open Tender
Civil Works - Buildings
Item Rate
90 days
WCL Ballarpur Area
As per NIT
4 documents required · 4 mandatory
₹50,200
5 Apr 2024
20 Jan 2024
1 Feb 2024
20 Jan 2024
30 Jan 2024
20 Jan 2024
20 Jan 2024 - 27 Jan 2024
Amount
Providing, hoisting and fixing up to floor five level precast reinforced cement concrete in small lintels not exceeding 1.5m clear span up to floor five level, including the cost of required centering, shuttering but , excluding the cost of reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III)derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources).
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more.
Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq.meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge.With cement mortar 1:4 (1 cement : 4 fine sand
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50m.All kinds of soil.
Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.
Providing and laying in position cement concrete ofspecified grade excluding the cost of centering and shuttering - All work up to plinth level :1:3:6 (1 Cement : 3 coarse sand (zone-III) derived fromnatural sources: 6 graded stone aggregate 40 mm nominal size derived from natural sources).
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, ifnishing and reinforcement- All work up to plinth level :1:1.5:3 (1 cement: 1.5 coarse sand (zone-III) derived from natural sources: 3 graded stone aggregate 20 mm nominal size derived from natural sources).
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources).
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass concrete
Centering and shuttering including strutting, propping etc. and removal of form forCentering and shuttering including strutting, propping etc. and removal of form for Columns, Pillars, Piers, Abutments, Posts and Struts
Centering and shuttering including strutting, propping etc. and removal of form forCentering and shuttering including strutting, propping etc. and removal of form for Lintels, beams, plinth beams, girders, bressumers and cantilevers
Brick work with clay flyash F.P.S. (non modular) brick of class designation 7.5 in superstructure above plinth level up to floor five level in :Cement mortar 1:6 (1 cement : 6 coarse sand)
Fencing with angle iron post placed at required distance embedded in cement concrete blocks, every 15th post, last but one end post and corner post shall be strutted on both sides and end post on one side only and provided with horizontal lines and two diagonals interwoven with horizontal wires, of barbed wire weighing 9.38 kg per 100 m (minimum), between the two posts fitted and fixed with G.I. staples, turn buckles etc. complete. (Cost of posts, struts, earth work and concrete work to be paid for separately). Payment to be made per metre cost of total length of barbed wire used With G.I. barbed wire
Painting with synthetic enamel paint of approved brand and manufacturer to give an even shade ( Two or more coats on new work )
12 mm cement plaster of mix : 1:6 (1 cement: 6 fine sand)
Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
brickwork with fly ash brickof approved qulity in cement mortar 1:6 in foundation and plinth as per the instructons of engineer in charge
Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters:30 mm thick including ISI marked Stainless Steel butt hinges with necessary screws
Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
Supplying and spreading of crushed stone aggregate of size 40 mm and down gauge in proper level grade and slope as per the instructions of engineer in charge.
Providing and laying APP (Atactic Polypropylene Polymer) modified prefabricated five layer, 3 mm thick water proofing membrane, black finished reinforced with glass fibre matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the same membrane manufactured of density at 25°C, 0.87 - 0.89 kg/litre and viscocity 70 - 160 cps. Over the primer coat the layer of membrane shall be laid using butane torch and sealing all joints etc., and preparing the surface complete. The vital physical and chemical parameters of the membrane shall be as under : Joint strength in longitudinal and transverse direction at 23°C as 350/300 N/5 cm. Tear strength in longitudinal and transverse direction as 60/80N. Softening point of membrane not less than 150°C. Cold flexibility shall be upto -2°C when tested in accordance with ASTM, D - 5147. The laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane :3 mm thick
Grading roof for water proofing treatment with Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size)
Welding by gas or electric plant including transportation of plant at site etc. complete.
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete
Earthwork in excavation in drains/ nallah of required size and shape in ordinary soil, soft rock, muddy soil etc.with the help of mechanical means by poclain, JCB etc and disposal of excavated earth within a lead upto 0.00 to 25.00 m from edges of drains as per the instructions of engg in charge.
Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. External work 25 mm dia nominal bore
Dismentalling of old dmaged APP from roof surface including removing the sheet and cleaning of surface as per the instructions of engg in charge.
Total impact of GST for the purpose of CTC
M/s. Tiwari Construction
S. K. PANDEY
M.V.K Engineering Services
SHYAMLAL MANGILAL CHOUDHARY
M A SHEIKH
tech_eval.pdf
fin_eval.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .