| 1 | L1₹11.3 LAccepted-AOC DAYA BAGH SATTANI DHAR ROAD UDHAMPUR DISTT UDHAMPUR J K 182101 | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L1 | Accepted-AOC BEING 1ST LOWEST BIDDER | |
| 2 | L2₹13.4 L+₹2.1 L (18.6%)Rejected-Finance | L2 | Rejected-Finance 2nd lowest bidder after deducting the sch of credit Rs 68550 | |
| 3 | L3₹14.2 L+₹2.9 L (25.3%)Rejected-Finance | L3 | Rejected-Finance 3rd lowest bidder after deducting the sch of credit Rs 68550 | |
| 4 | L4₹14.3 L+₹3.0 L (26.4%)Rejected-Finance | L4 | Rejected-Finance 4th lowest bidder after deducting the sch of credit Rs 68550 | |
| 5 | L5₹15.6 L+₹4.3 L (37.7%)Rejected-Finance NEAR INDUSTRIAL ESTATE THANDA PADDAR UDHAMPUR J K 182101 | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L5 | Rejected-Finance 5th lowest bidder after deducting the sch of credit Rs 68550 |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
27 Jul 2022, 6:00 pmClosed
GE (Army) Dhar Road
GE (Army) Dhar Road
REPAIR AND MAINT OF INTERNAL WIRING FITTING FIXTURES AND CONNECTED WORKS AT JINDRAH UNDER GE (ARMY ) DHAR ROAD
2022_MES_533368_1
8068/NIT-29/2022-23
Open Tender
Electrical and Maintenance Works
Item Rate
240 days
Jindrah
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
Yes
GE (Army) Dhar Road
₹50,000
Yes
29 Apr 2023
24 Jun 2022
29 Jul 2022
24 Jun 2022
27 Jul 2022
9 Jul 2022
Amount
Taking down old unserviceable/deteriorated batten/PVC conduit point wiring aluminium/ copper from existing place i.e. light, fan, socket or power points complete with all unserviceable fittings such as switches, sockets,bell push , ceiling rose, pendants, Holders, etc and making good all disturbed surface to wall, floor etc by means of cement mortar (1 : 3) or plaster of Paris and to match / finish new surface as the existing surface either by using same colour distemper, Putti or white / colour wash all as required and directed by Engineer-in-Charge.
M & L for concealed point wiring on wall and ceiling/roof with necessary fixing arrangements with PVC-FRLS insulated and unsheathed copper multi-stranded conductor of size 1.5 Sqmm, 1100 volts grade drawn in and including rigid non metallic white / ivory PVC conduit medium grade ISI marked not less than 20 mm dia with all conduit accessories/ fittings such as junction boxes, bends, tee, elbow etc including anodized MS sunken boxes made out of MS sheet of thickness not less than 1.6 mm with earth dolly and Bakelite laminated sheet 3mm thick ISI marked for fixing of switches / sockets, fan regulators, wall mounting fittings, door bell & bulkhead etc with MS screw and cup washers including PVC-FRLS insulated and unsheathed copper multi-stranded conductor of size 1.5 Sqmm, 1100 volts grade for continuous earthing including cutting the chases and making good the surface by cement mortar (1:3) and for matching / finishing of new surfaces either by means of plaster of peris/ Putti or distemper / colour wash with same existing colour surfaces all as specified and directed by Engineer-in-Charge for the following:-
One light /Fan/Bell point controlled by one switch 6/5 Amp one way single pole.
One 3 pin socket outlet 6/5 Amps controlled by one switch on the same board with other switches.
One 3 pin 6/5 Amp socket outlet controlled by one switch independent board.
One 3 pin 6/5 Amp socket outlet controlled by one switch independent board but below/ side the switch board of light point in same vertical / horzintal plane.
All as per item No 2 here-in-before but for power point wiring with 2.5 Sqmm PVC-FRLS insulated, unsheathed, copper conductor, stranded 1100 volt grade cable and 1.5 Sqmm PVC-FRLS insulated, unsheathed, copper conductor, stranded 1100 volt grade cable as continuous earth lead.
All as item no 2 here-in-before One 3/5 pin 15 Amp socket outlet controlled by one switch indep board but below/ side the switch board of light point in same vertical / Horzintal plane.
Taking down old unserviceable/deteriorated point wiring aluminium/ copper (excluding PVC conduit) from existing place i.e. light, fan, socket or power points complete with all unserviceable fittings such as switches, sockets,bell push , ceiling rose, pendants, Holders sunken box, etc and making good all disturbed surface to wall, floor etc by means of cement mortar (1 : 3) or plaster of Paris and to match / finish new surface as the existing surface either by using same colour distemper, Putti or white / colour wash all as required and directed by Engineer-in-Charge.
M&L for drawing the wire in existing conduit steel/PVC, concealed / surface ,complete with point wiring with FR PVC insulated, unsheathed stranded copper conductor of nominal area 1.5 Sqmm, 1100 volts grade, along with one single run of same size and type of copper wire as continuous earth wire to common earth dolly in and sunken terminal boxes pressed MS/GI steel terminal boxes not less than 1.20 mm thick for mounting switch, socket etc including 3 mm thick Hylam brand sunmica laminated sheet cover with brass screw and cup washers with all accessories and making good to disturbed surface with cement mortar ratio of 1:3 and matching surface with existing white/colour wash, oil bound or cement base paint etc to match with existing surface complete all as specified and directed and suitable for the following: -
One light, fan, call bell point controlled by one switch
-Ditto- all as per item No 6 here-in-before but For one socket point 6 Amps controlled by one switch on same board
-Ditto- all as per item No 6 here-in-before but for 5 Amp independent socket point controlled by one switch
All as per item No 6 here-in-before but in exsiting concealed/surface PVC conduit for power point wiring with 2.5 Sqmm PVC-FRLS insulated, unsheathed, copper conductor, stranded 1100 volt grade cable and 1.5 Sqmm PVC-FR insulated, unsheathed, copper conductor, stranded 1100 volt grade cable as continuous earth lead.
S&F switch piano flush type (ISI marked), single pole, one way 6 Amp, 240 Volts complete all as specified and as directed. Make : Legrand/Havells/Cona
S&F switch piano flush type (ISI marked), single pole, one way 16/15 Amps, 240 Volts including complete all as specified and as directed.Make : Legrand/Havells/Cona
S&F socket outlet 3 pin, 6 Amp piano flush type including complete all as specified and as directed. Make : Anchor/SSK/Havells/Cona
S&F socket outlet, 2 in 1, 3/5 pin 6 / 16 Amp, piano flush type complete all as specified and as directed Make : Legrand/Havells/Cona
S&F bell push 5/6 Amps SP flush type complete all as specified and as directed. Make : Legrand/Havells/Cona
M&L for modular snap switch,single pole,one way,6 Amp suitable for 1 module complete all as specified & directed Make -Havells/Craptary/Legrand
M&L for modular snap switch,single pole,one way,16 Amp suitable for 1 module complete all as specified & directed Make -Havells/Crabtree/Legrand
M&L for modular bell push,single pole,one way,6 Amp suitable for 1 module complete all as specified & directed Make -Havells/Crabtree/Legrand
M&L for modular snap Socket outlet,5pin,6 Amp flush type suitable for 2 Module complete all as specified & directed Make -Havells/Crabtree/Legrand
M&L for modular snap Socket outlet, 2 in 1 pin,6/16 Amp flush type suitable for 2 Module complete all as specified & directed Make -Havells/Crabtree/Legrand
M&L for modular white cover plate with frame for 1 module complete all as specified & directed
M&L for modular white cover plate with frame for 2 module complete all as specified & directed
M&L for modular white cover plate with frame for 4 module complete all as specified & directed
M&L for modular white cover plate with frame for 8 module complete all as specified & directed
M&L for modular white flush box for 1/2 module complete all as specified & directed
M&L for modular white flush box for 4 module complete all as specified & directed
M&L for modular white flush box for 6/8 module complete all as specified & directed
M&L for modular fan regulator stepped type with frame plate flush type for 2 modules complete all as specified & directed Make Havells/Crabtree/Legrand
S&F ceiling rose, surface bakelite, 65mm x 50mm, two to three terminals complete all as specified and as directed. Make : Legrand/Havells/Cona
S&F for batten angle lamp holder insulated body with back plate suitable for batten fittings including complete all as specified and as directed.Make : Legrand/Havells/Cona
S&F Ding dong sound door call bell electric AC 240 volt, 50 Hz ding dong type including taking down unserviceable complete all as specified and as directed. Make : Legrand/Havells/Cona
Supply & Fixing medium step type fan regulator 80 Watt, 240 Volt AC, socket size, medium step" ISI marked complete all as specified and directed. Make Cona / Anchor/SSK/Crabtree
M & L for sub main wiring in replacement of worn out aluminium conductor wire with two run of FR PVC insulated unsheathed flexible copper conductor (Multistrands), single core of size 6.0 Sqmm, 1100 Volts grade and one run of 4.00 Sqmm FR PVC insulated unsheathed as earth (In Green Colour), flexible copper conductor (Multistrands) for continuous earthing conforming to IS 694 with latest amendments and drawing in PVC rigid conduit , connecting incoming / outgoing electric connections by using required size copper lugs / thimbles and making good the disturbed surface to match with existing complete in all respect all as specified and directed. Note :- 1. Two run of single core cable with one run of contineous earth wire of copper conductor wire Flexible (Multistrand) of FR PVC insulated shall be measured and paid as one unit length. 2. PVC conduit pipe with fitting shall be measured and paid separately .Make-Havells/Finolex/Polycab/Grandley
M & L for sub main wiring in replacement of worn out aluminium conductor wire with two run of FR PVC insulated unsheathed flexible copper conductor (Multistrands), single core of size 4.0 Sqmm, 1100 Volts grade and one run of 2.5 Sqmm FR PVC insulated unsheathed as earth (In Green Colour), flexible copper conductor (Multistrands) for continuous earthing conforming to IS 694 with latest amendments and including draw in PVC rigid conduit 25 mm dia , connecting incoming / outgoing electric connections by using required size copper lugs / thimbles and making good the disturbed surface to match with existing colour (distumber, Oil bound, Samosem etc ) complete in all respect all as specified and directed. Note :- 1. Two run of single core cable with one run of contineous earth wire of copper conductor wire flexible (Multistrand) of FR PVC insulated shall be measured and paid as one unit length 2. PVC conduit pipe with fitting shall be measured and paid separately . Make-Havells/Finolex/Polycab
Supplied and fixing in replacement PVC conduit by Non Metallic Rigid PVC conduit, ISI Marked, conforming to IS 9537, medium grade of size 25 mm dia including all fittings like bends, elbow reducer, junction boxes, tee bell mouth all fixing accessories such as coupler lock, nuts, saddles pipe hooks etc complete including Cutting & Chasing required on brick wall not exceeding 10 CM girth for concealed conduit wiring and making good to disturbed surface with cement mortar 1:3 and distemper / colour wash etc to match with existing surfaces including facing / finishing complete all as specified and directed.
S & F service connection with twin core 10 Sqmm 240 volt heavy duty un armured PVC insulated stranded aluminium conductor cable served with inner sheathing of PVC tape and overall PVC sheathed in service connection in replacement of old unseriveable conductor cable complete. Make : Plaza /Polycab/Havells/finolex
S & F service connection with twin core 6 Sqmm 240 volt heavy duty un armured PVC insulated stranded aluminium conductor cable served with inner sheathing of PVC tape and overall PVC sheathed in service connection in replacement of old unseriveable conductor cable complete. Make : Plaza /Poly cab/Havells/fenolex
S & F service connection with twin core 4 Sqmm 240 volt heavy duty un armured PVC insulated solid/ stranded aluminium conductor cable served with inner sheathing of PVC tape and overall PVC sheathed in service connection in replacement of old unseriveable conductor cable complete. Make : Plaza /Poly cab/Havells/fenolex
Supply & Fixing in replacement of DB by SPN Distribution Box, double door of protection grade IP 43 in fine powder coated, matt finish with best CRCA sheet, fitted with shrouded neutral, insulated pin type copper bus bar, Din rail, earth bar of 4 way complete all as specified and directed.
Supply & Fixing in replacement of DB by SPN Distribution Box, double door of protection grade IP 43 in fine powder coated, matt finish with best CRCA sheet, fitted with shrouded neutral, insulated pin type copper bus bar, Din rail, earth bar of 8 way complete all as specified and directed.
Supply & Fixing in replacement of DB by SPN Distribution Box, double door of protection grade IP 43 in fine powder coated, matt finish with best CRCA sheet, fitted with shrouded neutral, insulated pin type copper bus bar, Din rail, earth bar of 12 way complete all as specified and directed.
Supply & Fixing in replacement of DB by TPN Distribution Box vertical 4 way, double door of protection grade IP 43 including provn for 4 Pole MCCB frame upto 200 Amps as incomer in fine powder coated, matt finish with best CRCA sheet, fitted with shrouded neutral, insulated pin type copper bus bar, Din rail, earth bar of way, confirming to IS 13032 & 8623 including chasing/cutting of wall and concealed and making good as existing surface complete all as specified and directed.
Supply & Fixing in replacement of DB by TPN Distribution Box 4 way, double door of protection grade IP 43 fine powder coated, matt finish with best CRCA sheet, fitted with shrouded neutral, insulated pin type copper bus bar, Din rail, earth bar of way, confirming to IS 13032 & 8623 including chasing/cutting of wall and concealed and making good as existing surface complete all as specified and directed.
supply and fixing of MCCB 125 Amps 16 KA with fixed thermal magnetic release frame 4pole all as specified and directed
supply and fixing of MCCB 100 Amps 16 KA with fixed thermal magnetic release frame F2 optim 1.0 , 4pole all as specified and directed.
Supply & Fixing MCB SPN, 5 to 40 Amps 240 volts, AC , 10 KA breaking capacity 'C' Series,"ISI marked and conforming to IS 8828/IEC 60898-1 complete all as specified and directed.
Supply & Fixing MCB SP, 06 to 40 Amps 240 volts, AC , 10 KA breaking capacity 'C' Series,"ISI marked and conforming to IS 8828/IEC 60898-1 complete all as specified and directed.
Supply only MCB TPN, 63 Amps 240 volts, AC , 10 KA breaking capacity 'C' Series,"ISI marked and conforming to IS 8828/IEC 60898-1 complete all as specified and directed. .
Supply and fixing Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amps
S&F Wall mounted LED batten 18/20 Watt inbuilt LED panel aluminium heat sink provided for efficient heat dissipation and integrated electronic driver including dismantling taking down unsv FTL fitting T8 type any type complete all as specified and directed. Make: Havells equivalent in Philips/Crompton
S&F Wall mounted LED light fitting mirror type, 10 Watt 220V decorative type incl integrated electronic driver and connecting up with three core flexible copper conductor including dismantling taking down unsv sketch fitting any type complete all as specified and directed. Make: Havells equivalent in Philips/crompton
Supply and fixing wall mounted fancy decorative light fitting with 12 watt LED lamp clear white/warm white with acrylic/glass cover with holder, bracket and connected with ceiling rose /junction box wire 230 volt AC all as specified and directed Make Havells/crompton /wipro
S&F Bulk head fitting 10 watt LED incl water proof , weather proof all as specified and directed in replacement of old unserviceable filling .complete all as directed by engr-in-charge
S&F LED building security light 35 watt, 230V complete with all accessories and including connecting up to ceiling rose with 0.5 sqmm three core copper flexible conductor cable, One GI medium grade suitable size dia bracket of total length 1.50 mtr and fixed to wall with 2 Nos MS Clamp and fastener incl dismentling taking down unsv fitting any type all as specified and directed.
Supply and Fix LED lamp 10 watt white/warm white , B-22 cap, (Pin type), 230V, PF-0.95 (min) incl dismentling taking out unsv CFL/LED Bulb. Make - Philips/Bajaj/Havells
Supply and Fix LED lamp 15 watt white/warm white, B-22 cap, (Pin type), 230V, PF-0.95 (min) incl dismentling taking out unsv CFL/LED Bulb. Make - Philips/Bajaj/Havells
Replacement of recesses mounted LED ceiling mounted fitting 10 Watt cercular shape multi colour panel (03 colour) 1000 Lm 220-230 volt, AC, 50Hz, PF>0.9, all as specified and directed. Make Crompton/Havells/Orient/Philips
Supply and fixing in replacement of Mirror optic fitting by recess/surface mounted mirror optic LED luminaire fitting with paralite P5 louvers 35/36 watt LED, 6500K, white/warm white dimention 600mm x 600mm fitting for grid type ceiling including control driver and other accessories complete all as specified and directed. Make:Philips/Crompton /wipro/Havells
M&L for earthing as per IS:3043 with galvanized steel earth plate electrode 600 x 600 x 6.0 mm thick buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metre below normal ground level connected to galvanized iron wire 4 mm dia (8 SWG) as earthing lead protected by GI pipe medium grade 15 mm bore for protection of GI earth wire and 20 mm dia GI pipe medium grade for watering with alternate layers of charcoal /coke and salt including all accessories like nut, bolts, reducer, nipple, wire meshed/screened funnel and making brick masonry finished chamber of internal size 300 mm x 300 mm x 300 mm with concrete base, covered with PCC cover which shall be embedded in the block masonry including excavation works, refilling, connected to main switch/MCB DB for feeding the electric supply to domestic quarters compete all as specified as shown in electricall plateNo. 3 of SSR Part-I and testing of earth resistance as required. Note : Earthing lead/G.I.Earth wire upto 7.5 metre length shall be deemed to be included in quoted unit rate beyond 7.5 metre, the same shall be measured and paid separately).
Taking out old unsv electric meter and deposit to E/M store and S&F for enrgy meter electronic type temper proof LCD display with polycarbonate cover 230V, 10 - 60 Amps accuracy class - I 50Hz,,confirming to IS 13779,IP-54,with parameters to show data,time,current reading,load,PF,voltage and KWH single phase all as specified and direcetd by Engr-in-Charge Make : ABB/L&T/Schenider
Supply and fixing in replacement of DB by SPN DB, 2 way , double door of protection grade IP43 in fine powder coated matt finish with best CRCA sheet, fitted with shroulded neutral, insulated pin type copper bus bar, Din rail, earth bar complete all as specified and directed.
Taking out old unsv electric meter and deposit to E/M store and S & F for enrgy meter 3 phase electronic type temper proof LCD display with polycarbonate cover 415V, 10-60 Amps accurecy class-I 50Hz, confirming to IS 13779, IP-54 with parameters to show data, time, current reading, load,PF, voltage and KH single phase all as specified and directedn by Engr-in Charge.Make : ABB/L&T/Schneider.
S & F switch socket combination 3 pin, 6 Amp piano flush type including complete all as specified and as directed, Make Anchor/SSK/Havells/Cona
S & F switch socket combination 2 in 1,3/5 pin, 6/16 Amp piano flush type complete all as specified and as directed, Make Legrand/Havells/Cona
Supply and fixing plug top 15 Amps 3 pin, single phase, 230 volts AC all as specifiedn and directed.
M/S Builders Indias
KARAN TRADERS
Rakesh Kumar Malia
K S BUILDERS
m/s shanti trading company
MandeepConstructionCo
SUBASH CHANDER
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .