SH A K SINGH SE CWE NAVY VASCO
CWE NAVY VASCO VASCO DA GAMA GOA 403802
MANNING AND OPERATION OF LIFTS AT HQ KNA NSRY NOM MESS PATANJALI AT NAVAL BASE KARWAR AND MANNING AND OPERATION INCLUDING REPAIR AND MAINTENANCE OF DISTRIBUTION SUB STATION DSS 01 DSS 08 AT NAVAL BASE KARWAR AND DSS 17 AT AMDALLI UNDER GE SB KARW
2020_MES_406916_2
85290/E8
Open Tender
Civil Works
Item Rate
334 days
CWE NAVY VASCO
AS PER TENDER DOCUMENTS
9 documents required · 9 mandatory
₹1,000
Yes
GE (SB) KARWAR
₹1.5 L
Yes
26 Mar 2021
15 Feb 2021
17 Mar 2021
15 Feb 2021
15 Mar 2021
1 Mar 2021
Amount
LIFTS AT HQ KNA, NSRY, NOM MESS & PATANJALI
Notes for Item Nos 1 to 4:- (a) The Contractor shall not employ same tradesman continuously for more than 11 months. (b) The contractor shall provide 02 uniforms to each operator and design of uniform shall be got approved from Engineer-in-Charge. In case contractor fails to provide the uniform, recovery @ of Rs 100/- per day per operator shall be recovered (c) The rate quoted shall deemed to be inclusive of safety gear & required tools for minor maintenance. In case of failure to provide tools kit & safety kit (Gum boots-02 pairs) a penalty of Rs 3000/- shall be recovered and levied. (d)The Contractor shall maintain proper records of all kinds of daily, weekly, monthly, quarterly, half yearly and yearly or whatsoever maintenance is carried out during contract period in a binded book / register and shall obtain the signature of Engineer-in-Charge every fortnightly.
(e) Each shift duration shall be 08 hours & duty timing will be decided by Engineer-in-Charge. (f) In case of failure due to absence of operative staff,the contractor shall be liable to pay compensation at twice the cost of a day's Manning & operation derived from pro rata rate of Sch'A' quoted rates or Rs.1000 per person per shift whichever is higher. (g)The operator shall ensure general area cleanliness and upkeep of the lift on daily basis. (h) The contractor shall pay the wages to the operator through e-payment i.e Aadhar linked bank accounts and Credit to their bank account. The wages shall not be less than prevailing minimum wages fixed by state Govt or central Govt whichever is more.
(j) It is the responsibility of contractor to deposit the employees provident fund (EPF) to the concerned authority as per the prevaling scales as laid down by Ministry of labour for all operator/helper (as applicable) and necessary proof to this regard shall be submitted to the Engineer-in-charge for verification & record. The quoted rates shall be deemed to be included of above provisions. In case contractor fails to produce the proof of EPF, the same shall be recovered from his dues as per the prevailing scale plus 15 percent. (k) The contractor shall provide board at proper location near each installations duly writing the name of operators and Mobile Numbers shiftwise. (l) Contractor shall display the lift safety precautions as per Appendix ‘C’ enclosed as serial page Nos.148 & 149 are enclosed herewith and as directed by the Engineer-in-Charge. (m) The rates quoted shall be inclusive of all taxes, cess, levies etc as applicable including GST (n) The prevailing rate,wage,contribution etc shall be as applicable as on the bid submission end date.
(o) In view of COVID-19 alerts various restrictive instructions issued concerned authorities from time to time. Hence additional precautions essential for the work shall be taken by the contractor by way of provisioning of masks, hand sanitizers, gloves etc to workmen and all local instructions issued by the Concerned Authorities and Station Authorities shall be complied with all relevant safety precautions covered under Model Rules for the protection of health and sanitary arrangement for workmen (Annexure ‘C’) of IAFW-2249) shall be strictly followed. Nothing extra is admissible on this account (p) The contractor shall also deploy additional man power as relief against weekly off,leave,holidays etc all as per existing Labour Act and shall substitute the operator accordingly for which no extra payment admissible. The unit rate quoted against items in Schedule ‘A’/BOQ shall be inclusive of this provision also.
DSS-01 & 08 AT NAVAL BASE KARWAR
Manning and Operation of Distribution Sub Station (DSS - 1) at KNOFRA Little Binaga, the main load centre at officer's residential area for three shifts of 8 hours each on all days including Sundays and holidays including routine preventive maintenance / checks, attending emergency breakdowns at Distribution Sub Stations DSS 1, DSS 1A and connected feeder pillars all as directed
Manning and Operation of Distribution Sub Station (DSS - 8), the main load centre at sailor's residential area for three shifts of 8 hours each on all days including Sundays and holidays including routine preventive maintenance / checks, attending emergency breakdowns at Distribution Sub Stations DSS 8, DSS 9, DSS-10 & DSS-11 connected feeder pillars all as specified and as directed
Notes for Item Nos 5 to 6:- (a) The rates quoted shall be inclusive of all taxes ,cess, levies etc as applicable including GST (b) The prevailing rate,wage,contribution etc shall be as applicable as on the bid submission end date. (c) Shift timings:1st shift from 0600 hrs to 1400 hrs,2nd shift from 1400 to 2200 hrs and 3rd shift from 2200 hrs to 0600 hrs respectively (d) Contractor has to employ minimum one No skilled electrician /operator per shift of 8 hour each,(Total 06 shifts per day) having minimum ITI qualification in Electrician trade from Govt recognized institute with adequate knowledge with minimum 2 years experience in Maintenance & Operation of HT & LT electrical installation. The operator must be competent to carry out the routine maintenance and attending breakdowns all as directed (i) The contractor shall pay the wages to the operator through e-payment i.e Aadhar linked bank accounts and Credit to their bank account. The wages shall not be less than prevailing minimum wages fixed by state Govt or central Govt whichever is more.
(ii) It is the responsibility of contractor to deposit the Employees Provident Fund (EPF) to the connected authority as per the prevailing scales as laid down by the Ministry of labour for all Electrician/operator/helper (as applicable) and necessary proof to this regard shall be submitted to GE for verification and records. The quoted rate shall be deemed to be included of above provisions. In case contractor fails to produce the proof of EPF, he shall be liable for action as deemed fit. Decision of GE in this regard shall be final and binding. (e) The unit rate quoted shall be deemed to include for cost of labour for daily routine maintenance as mentioned in particular specifications for trouble free functioning of installations. (f) The operator employed by the contractor shall be capable of carrying out minor maintenance & unit rate quoted shall be deemed to be include for cost of stationery, ink cartridge for printer, cotton waste ,petroleum jelly for battery terminals etc. (g) The Contractor shall maintain proper records of all kinds of daily, weekly, monthly, quarterly, half yearly and yearly or whatsoever maintenance is carried out during contract period in a binded book / register and shall obtain the signature of Engineer-in-Charge. (h) Cost of stationery is deemed to include in the unit rate quoted against Item No 5.00 & 6.00 of Sch 'A'. (j) The contractor will ensure general area cleanliness and upkeep of the installation on daily basis.
(k) The contractor shall maintain all the registers under various labour law rules, 2017 and shall be produced to GE and as well as officers detailed by labour department. (l) Cost of routine maintenance spares will be measured and paid separately under respective item here in after. However cost of labour is deemed to be included in the unit rate quoted above. (m) The unit rate quoted shall deemed include for maintenance for earth pits, cutting & removing of vegetation and upkeep of the surrounding area, all around the bldg up to 6m from the plinth protection all as directed by Engineer-in-Charge. In case of failure, a penalty of Rs 2000/- per month will be levied and recovered from dues. (n) In the case of absence of operator, penalty will be charged as doubled as quoted rate or Rs 1000/-per shift whichever is higher besides any loss/damages occurring during the period which will have to be made good by the contractor
(o) The contractor shall provide 02 uniforms to each operator & helper and design of uniform shall be got approved from Engineer-in-charge. In case contractor fails to provide the uniform, recovery @ of Rs 1200/- per uniform will be recovered. (p) The rate quoted shall deemed to be inclusive of safety gear & required tools for minor maintenance. In case of failure to provide tools kit & safety kit (Gum boots-02 pairs, hand gloves), a penalty of Rs 3000/- will be recovered and levied (q) In view of COVID-19 alerts various restrictive instructions issued concerned authorities from time to time. Hence additional precautions essential for the work shall be taken by the contractor by way of provisioning of masks, hand sanitizers, gloves etc to workmen and all local instructions issued by the Concerned Authorities and Station Authorities shall be complied with all relevant safety precautions covered under Model Rules for the protection of health and sanitary arrangement for workmen (Annexure ‘C’) of IAFW-2249) shall be strictly followed. Nothing extra is admissible on this account (r) The contractor shall also deploy additional man power as relief against weekly off,leave,holidays etc all as per existing Labour Act and shall substitute the operator accordingly for which no extra payment admissible. The unit rate quoted against items in Schedule ‘A’/BOQ shall be inclusive of this provision also.
Supply only Ammeter Analog type suitable to 0 - 100 Amps all as specified and as directed
Supply only Aluminum lugs suitable for 25 sqmm to 50 sqmm cables all as specified and as directed
Supply only Aluminum lugs suitable for 70 sqmm to 150 sqmm cables all as specified and as directed
Supply only Aluminum lugs suitable for 150 to 300 sqmm cables all as specified and as directed
Supply only Sheared rubber gasket suitable to LT panel board any description all as specified and as directed
Supply only Indicator lamp LED type 'RYB' all as specified and as directed
Supply only Volt meter Analog type 0-500 Volts all as specified and as directed
Servicing of dry cast transformer 1600KVA , 11 KV/433V by disconnecting incoming & outgoing power supply, opening up, cleaning the transformer internally & externally inspecting all the metering equipments, tightening all electrical connections checking & recording insulation resistance on both LT & HT sides, checking & recording earth resistance complete through authorised Service Engineer of OEM all as specified and as directed. Location : DSS-1/ DSS-1A/ DSS4/ DSS-4A/ DSS-6/ DSS-8/ DSS-9
Servicing of oil cooled transformer 500 KVA , 11 KV/433V by disconnecting incoming & outgoing power supply, opening up, cleaning the transformer internally & externally inspecting all the metering equipments, tightening all electrical connections checking & recording insulation resistance on both LT & HT sides, checking & recording earth resistance complete through authorised Service Engineer of OEM all as specified & as directed. Location : DSS-10 and DSS-11 at corritop
S&F ACB 4 Pole, 415 V, Manual Draw out type with microprocessor release of capacity 630 Amps complete all as specified and as directed by Engineer-in-Charge.
Supply and Laying in repair LT UG cable 1100 Volts grade XLPE insulated PVC sheathed armoured, heavy duty, in trenches/walls/poles/passing through pipes with multi stranded aluminium conductor including lugs/thimble/ferules connection, testing and commissioning complete including taking out old unserviceable cable for 35 sq mm 3.5 core all as specified and as directed Notes: (i) Earth work, excavation sand cusioning, bricks for protection, GI pipe etc shall be measured separately under relevant items of this schedule. (ii) Old retrieved LT cable found in serviceable condition from taking out shall be re-use/relay in the work. (iii) item will only be operated/executed in the condition of non availablity of sch 'B' stores with the department
Excavation in trenches not exceeding 1.5 m deep and not exceeding 1.5 m wide and getting out in hard/dense soil all as specified and as directed
Returning filling in leveling watering and well ramming in layers not exceeding 25cm thick all as specified and as directed
Removal of surplus soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point all as specified and as directed
Supplying & Laying in trenches clear sand for cushioning under ground cable 8 cm below and 15 cm above complete in level all as specified and as directed Note:Punned thickness of sand shall be measured and paid
Supplying and laying unreinforced precast concrete cable cover, class HV Type-1, flat size 300mm x 180mm x 40mm with ISI mark factory made complete all as specified and as directed
M& L for MCCB 4 pole, 415 volts fixed overload & fixed short circuit setting including disconnecting the incoming/outgoing cable connections and re-connecting with suitable aluminum lugs/ferrules etc. after taking out the existing unserviceable and making good the disturbed surface for following capacity 160 Amps with breaking capacity 36 KA all as specified and as directed
All as per Item No.23 herein before but for 200 Amps with breaking capacity 36 KA
All as per Item No.23 herein before but for 250 Amps with breaking capacity 36 KA
All as per Item No.23 herein before but for 315/350 Amps with breaking capacity 36 KA
All as per Item No.23 herein before but for 400 Amps with breaking capacity 36 KA
M & L for earthing complete with galvanized steel earth plate electrode 600mm X 600mm X 6mm buried directly in ground vertically to a depth not less than 4.50 meter below normal ground level (with top edge of earth plate not less than 3.25 meter below ground level) connected to GI strip 32mm X 6mm main earthing lead by means of galvanized bolts, nuts and washers all as shown in electrical plate no 5 of MES Schedule Part-I (1991) with connected to earth test point & to main switch board /panel etc. all as specified and testing on completion with and including necessary excavation and earth work in any type of soil, earth electrode, earthing lead from electrode to equipment/substation/panel etc, adequate quantity of charcoal dust and common salt, PCC (1:3:6) type C-1 (using 20mm graded black trap/granite/Basalt stone aggregate) for earth pit with 40 x 40 x 6mm mild steel angle iron frame for cover, pre cast RCC (1:2:4) type B-1 (using 20mm graded black trap/granite/Basalt stone aggregate) 40mm thick cover reinforced with 8mm dia TMT bars 3 Nos both way with 12mm dia round MS bar handle, GI light grade watering pipe 15 mm dia with funnel and wire mesh, and 40 mm dia GI light grade earth lead protection pipe, complete all as specified and as directed
S&F 32mm X 6mm ,GI earth strip all as specified and as directed
S&F GI tubing 'Light' grade 50 mm bore with all fittings for cable protection fixed on poles/walls/laid under roads crossing etc and made good the disturbed surfaces/area for following sizes of pipes all as specified and as directed
All as per Item No.30 herein before but for 80 mm bore all as specified and as directed.
DSS-17 AT AMDALLI
Manning and Operation of Main Receiving Distribution Sub Station (33KV/11KV) (DSS-17), 11 KV/433 Volt HT supply installation at site B, Amdalli town ship Karwar for three shifts of 8 hours each on all days including Sundays and Holidays including minor daily maintenance/checks and also attending breakdown at DSS-17A & DSS-17B, all as specified and as directed . The installation comprises of following equipments :- (a) 33 KV, indoor type HT VCB - 1 No (b) Indoor type Power transformer 2 MVA, 33 KV/11KV - 1 Nos. (c) Main LT Panel board 415 V with ACBs & main switches MCCBs etc (d) Battery bank for auxillary supply. (e) 55 Nos of batteries to maintain 110 V battery bank with charging panel.
Notes:- (a) The rates quoted shall be inclusive of all taxes ,cess, levies etc as applicable including GST (b) The prevailing rate,wage,contribution etc shall be as applicable as on the bid submission end date. (c) Contractor has to employ minimum following staff for Manning and operation of the DSS -17 in all 3 shifts 8 hours each. (i) One skilled electrician/operator per shift (3 shifts per day) having minimum ITI qualification in Electrician trade from Govt recognised institute with adequate knowledge for HT & LT electrical installation. The operator must be competent to carryout the routine preventive maintenance of Main distribution sub station all as directed. (ii) One No helper minimum 10th class pass per shift (03 shift per day). (d) Cost of spares if any to be replaced will be measured & paid separately under respective item here in below. However cost of labour is deemed to be included in the unit rate quoted in this item
(e) Each shift duration shall be 8 hours and duty timings will be decided by Engineer-in-Charge. (f) The unit rate quoted shall be deemed to include for maintenance for earthpits, cutting & removing of vegetation and upkeep of the surrounding area, all around the bldg upto 6m from the plinth protection all as directed by Engineer-in-Charge. In case of failure, a penalty of Rs 2000/- per month will be levied and recovered from dues. (g) The contractor shall pay the wages to the operator through e-payment i.e Aadhar linked bank accounts and Credit to their bank account. The wages shall not be less than prevailing minimum wages fixed by state Govt or central Govt whichever is more. (h) In the case of absence of operator, penalty will be charged as doubled as quoted rate or Rs 1000/-per shift whichever is higher besides any loss/damages occurring during the period which will have to be made good by the contractor
(j) It is responsibility of contractor to deposit the employees provident fund (EPF) to the connected authority as per the prevailing scales as laid down by the Ministry of labour for all operator/helper (as applicable) and necessary proof to this regard shall be submitted to GE for verification and records. The quoted rate shall be deemed to be included of above provisions. In case contractor fails to produce the proof of EPF, shall be liable for action as deemed fit. Decision of GE in this regard shall be final and binding. (k) The contractor shall maintain all the registers under various labour law rules, 2017 and shall be produced to GE and as well as officers detailed by labour department. (l) The contractor shall provide 02 uniforms to each operator & helper and design of uniform shall be got approved from Engineer-in-charge. In case contractor fails to provide the uniform, penlty of Rs 1200/- per uniform shall be recovered. (m) The rate quoted shall be deemed to be inclusive of safety gear & required tools for minor maintenance. In case of failure to provide tools kit & safety kit (Gum boots-02 pairs, 33 KV HT hand gloves), a penalty of Rs 3000/- shall be recovered and levied
(n) In view of COVID-19 alerts various restrictive instructions issued concerned authorities from time to time. Hence additional precautions essential for the work shall be taken by the contractor by way of provisioning of masks, hand sanitizers, gloves etc to workmen and all local instructions issued by the Concerned Authorities and Station Authorities shall be complied with all relevant safety precautions covered under Model Rules for the protection of health and sanitary arrangement for workmen (Annexure ‘C’) of IAFW-2249) shall be strictly followed. Nothing extra is admissible on this account (o) The contractor shall also deploy additional man power as relief against weekly off,leave,holidays etc all as per existing Labour Act and shall substitute the operator accordingly for which no extra payment admissible. The unit rate quoted against items in Schedule ‘A’/BOQ shall be inclusive of this provision also.
S & F in repair HRC Fuse 250 Amps, type-3 NW of Cat No-3NW TKF250 complete all as specified and as directed
S & F in repair synthetic insulating mat of size 2 m x 1 m x 19 mm thick complete all as specified and as directed
Supply & filling distilled water first quality in sealed container of standard capacity all as specified and as directed
S & F in repairs Strip heater 60/80 Watt suitable for indoor panel of existing size/model complete all as specified and as directed
S & F in repairs Thermostat with setting 0-80C of existing size/model complete all as specified and as directed
Servicing of dry cast Transformer 2 MVA at DSS - 17 by disconnecting incoming & outgoing power supply, opening up, cleaning the transformer internally & externally, inspecting all the metering equipments, tightening all electrical connections, checking & recording insulation resistance on both LT & HT sides, checking & recording earth resistance complete through authorised service engineer of OEM (Original Equipment Manufacturer) all as specified and as directed
Servicing of dry cast Transformer 750 KVA at DSS-17 by disconnecting incoming & outgoing power supply, opening up, cleaning the transformer internally & externally inspecting all the metering equipments, tightening all electrical connections checking & recording insulation resistance on both LT & HT sides, checking & recording earth resistance complete through authorised service engineer of OEM (Original Equipment Manufacturer) all as specified and as directed .
Filtration of existing Transformer Oil including heating to improve di- electric strength of oil to minimum 60 KV BDV including testing of BDV of the filtered oil before & after all as specified and as directed
Supply of low viscosity transformer oil, ISI marked to make up /top up oil deficiency in transformerall as specified and as directed
M & L for Servicing of 33 KV Vaccum Circuit Breaker (VCB) 400/ 630/ 800/1250 amps by authorised service engineer of OEM (Original Equipment Manufacturer), drawing out circuit breaker mechanism, cleaning throughly inside & outside, lubricating the mechanism, adjusting the required various mechanism setting, checking & lubricating the various interlocks, checking the breakers operations, checking the healthiness of pole by meggering, lubricating racking mechanism, checking the operation of various limit switches, checking the operation of the breaker & the racking mechanism, testing the unit on no load & on load complete all as specified and as directed
All as per item No 42 here in before but 11 KV Vaccum Circuit Breaker (VCB) all as specified and as directed Note for item No 42 & 43: (a) Servicing of breaker to be carried out by qualified engineer. The servicing of breaker will include:- (i) Inspection & cleaning the mechanism house. (ii) Operation of door interlock, interlocking plate & shutter operation inside of panel. (iii) Check the mechanical ON-OFF function, electrical & mechanical operation & damage parts of VCB. (iv) Re-greasing & oiling of breaker mechanism, adjustment of various mechanism setting as required, checking contact tightness, contact erosion pins, manually vacuum check of VCB.
(v) Rack in-rack out operation in test & service position of VCB trolly. (vi) Megger test( IR value-1 KV/2.5 KV) E-RYB, RY-YB-BR, R'R.Y'Y.B'B. (vii) CRM test (contact resistence) of vaccum interrupter R,Y,B in on condition out side of panel. (viii) Time test of contact pole by test kit(in mili second) (ix) Function of closing coil, Trip coil, spring charge motor, auxiliary contact, limit switch etc. (x) Checking & lubrication of various interlocks. (xi) Submission of test report in standard format of vacuum circuit breaker(VCB). (b) Tools & testing instruments reqd for servicing of VCB will be arranged by the contractor. (c) The unit rate quoted shall be deemed to include the cost of grease, cleaning material service & list of spares required for preventive /breakdown maintenance (d) After servicing report will be furnished to Engineer-in Charge in standard format approved by Engineer-in Charge. (e) List of spare parts required for preventive maintenance/emergency breakdowns shall be submitted to Engineer-in Charge after 1st inspection.
Taking out ACB of make Siemens of capacity 800 Amps to 1500 Amps, 3pole ,415 Volts, 125 KA indoor type from its sub cubicle and carrying out routine maintenance as per manufacturer maintenance manual, examine the moving isolating contacts for any dis colouration, cluster contacts, remove the arc chutes, check the SMC moulding are intacts, examine the moving contacts, main contacts silver tips, spring mechanism, clean all contacts with a suitable solvent and contacts re-greased with HP multipurpose grease, check setting of all contacts, re-adjusted if required, and re-greased with HP multipurpose grease, testing of all tripping device like manual trip, under voltage, shunt trip release, over current and earth fault tripping device, readjusted and confirm all tripping device is in healthy condition, check and record IR value of ACB with 1.1. KV LT megger calibrating ground fault / short circuit, overload relays for tripping & timing complete and rendering test report all as specified and as directed.
Notes : (a) Rates is inclusive of fixing of spares if any reqd. (b) Spare parts which required to replace will be paid under respective items of Sch 'A'. (c) The scope of work includes the following :- (i) Inspection & cleaning the mechanism house (ii) Operation of door interlock, interlocking plate & shutter operation inside of panel. (iii) Check the Mechanical ON-OFF function, electrical & mechanical operation and damage part of ACB. (iv) Re-greasing and oiling of breaker mechanism, adjustment of various mechanism setting as required, checking contact tightness, contact erosion pins, manually vacuum check of ACB. (v) Rack in-Rack out operation in Test & service position of ACB trolley. (vi) Megger test (IR value - 1KV / 2.5KV) E-RYB, RY-YB, BR-R'R, Y'Y, B'B. (vii) CRM Test (contact resistance) of Vacuum Interrupter R, Y, B in on condition out side of panel (viii) Function of closing coil, Trip coil, spring charging motor, auxiliary contact, limit switches etc.
(ix) Checking & lubrication of various interlocks. (x) Submission of test report in standard format of Air circuit breaker. (xi) Tools & testing instruments required for servicing of ACB will be arranged by the contractor. (xii) The unit rate quoted shall be deemed to include the cost of grease, lubricating material, cleaning material service & list of spares reqd for preventive / breakdown maintenance (d) After servicing report will be furnished to Engr-in Charge in standard format approved by Engineer-in Charge. (e) List of spare parts required for preventive maintenance/emergency breakdowns shall be submitted to Engineer-in Charge after 1st inspection.
M & L for testing of resistence of earthpits of transformer, panels etc after testing report will be furnished to Engineer-in Charge in standard format approved by Engineer in Charge.
M & L for calibration of relays of by primary current/voltage injection test complete for 33 KV/11 KV VCB panels and ACB panels/DG panels complete all as specified and directed.
M & L for painting to old steel surfaces of transformer, cable trays, panel board / LT out door panel board of DSS 17, DSS 17 A & B with one coat of synthetic enamel paint of approved shade using spray gun including cleaning/ removing, dust, dirt etc complete all as specified and as directed.
S&F in repair of current transformer 33 KV indoor type of ratio 100/1-1 single phase, 50hz, current ratio 800-400, including removing of old unserviceable CT complete all as specified and as directed.
S&F in repair of potential transformer indoor type, primary voltage 33KV, secondary voltage 11 KV single phase, 50hz, current ratio 800-400, including removing of old unserviceable PT all as specified and as directed.
S&F in repair of 11/33 KV bus bar supporting spout / Air break switch insulators single pole for indoor use 400 to 800 Amp suitable for existing panel all as specified and as directed.
S&F in repair of fuse indoor type, 33 KV, type PT AVT, Amps 3.15, 50hz, current ratio 800-400, including removing of old unsv fuse complete all as specified and as directed.
Supply, jointing & testing Indoor end termination type heat shrinkable 33 KV HT joint kit suitable for 3 core 185 Sqmm PVC / XLPE insulated stranded aluminium conductor all as specified and as directed.
S& F in repairs ACB 1250 Amps 4pole 415 V, manual draw out type with microprocessor release of capacity 630 Amps complete all as specified and as directed.
S& F in repairs ACB 630 Amps 4pole 415 V, manual draw out type with microprocessor release of capacity 630 Amps complete all as specified and as directed.
S&F in repairs MCCB 400 Amps 4 pole 36 KA breaking capacity,415 Volt adjustable type all as specified and as directed.
S&F in repairs MCCB 250 Amps 4 pole 36 KA breaking capacity,415 Volt adjustable type all as specified and as directed.
S&F in repairs MCCB 160 Amps 4 pole 36 KA breaking capacity,415 Volt adjustable type all as specified and as directed.
S&F in repairs MCCB 125 Amps 3 pole 25 KA breaking capacity,415 Volt adjustable type all as specified and as directed.
S&F in repairs MCCB 25 to 100 Amps 3 pole 16 KA breaking capacity,415 Volt fixed type all as specified and as directed.
Raheel Enterprises
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .