| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.7 LAccepted-AOC | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹39.8 L+₹7.0 L (21.3%)Rejected-Finance | L2 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 3 | L3₹41.8 L+₹8.9 L (27.2%)Rejected-Finance | L3 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 4 | L4₹43.3 L+₹10.5 L (31.9%)Rejected-Finance | L4 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 5 | L5₹44.3 L+₹11.5 L (34.9%)Rejected-Finance | L5 | Rejected-Finance OTHER THAN LOWEST BIDDER |
| Sl No | Description | Qty | Unit | M/S Farooq Ahmed Bhat L2 | M/S PARSHOTAM KUMAR GUPTA L1 | narayan construction L3 | VIKAS ENTERPRISES L5 | M/S KABIR CHOUDHARY L6 | M/S MANHAS ENTERPRISES L4 |
|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Excavation in trenches not exceeding 1.50 m wide and not exceeding 1.50 m in depth for taking up or laying pipe in soft/loose soil and getting out complete all as specified and directed. | 250 | Cum | 100 ₹25,000 | 80 ₹20,000 Lowest | 100 ₹25,000 | 100 ₹25,000 | 200 ₹50,000 | 100 ₹25,000 |
| 2.00 | Returning, filling in trenches including spreading leveling, watering and ramming in layers (soil) not exceeding 25 cm without damaginlg pipes specials/CI specials, fittings complete all as specified and directed. | 220 | Cum | 100 ₹22,000 | 10 ₹2,200 Lowest | 50 ₹11,000 | 600 ₹1,32,000 | 200 ₹44,000 | 20 ₹4,400 |
| 3.00 | Removing of surplus spoil to a distance not exceeding 50 mtr and deposited where directed at a level not exceeding 1.50 m above the strating point complete all as specified and directed. | 30 | Cum | 100 ₹3,000 | 10 ₹300 Lowest | 50 ₹1,500 | 1,000 ₹30,000 | 200 ₹6,000 | 15 ₹450 |
| 4.00S&F in repair steel water tubing galvanised, medium grade with all fittings and fixed complete to walls, or in floors , in old / new situation for bore of pipe complete all as specified and directed for following sizes:- | |||||||||
| 5.00 | 20 mm bore. | 300 | RM | 300 ₹90,000 | 184 ₹55,200 Lowest | 300 ₹90,000 | 320 ₹96,000 | 700 ₹2,10,000 | 200 ₹60,000 |
| 6.00 | 25 mm bore. | 350 | RM | 400 ₹1,40,000 | 257 ₹89,950 | 350 ₹1,22,500 | 500 ₹1,75,000 | 500 ₹1,75,000 | 200 ₹70,000 Lowest |
| 7.00 | 40 mm bore | 250 | RM | 500 ₹1,25,000 | 350 ₹87,500 | 500 ₹1,25,000 | 800 ₹2,00,000 | 800 ₹2,00,000 | 200 ₹50,000 Lowest |
| 8.00 | 50 mm bore | 300 | RM | 600 ₹1,80,000 | 514 ₹1,54,200 Lowest | 700 ₹2,10,000 | 900 ₹2,70,000 | 1,000 ₹3,00,000 | 2,000 ₹6,00,000 |
| 9.00S&F in repair steel water tubing galvanised, medium grade with all fittings, fixed and laid in trenches , in old / new situation for bore of pipe complete all as specified and directed for following sizes:- | |||||||||
| 10.00 | 20 mm bore. | 380 | RM | 250 ₹95,000 | 184 ₹69,920 | 300 ₹1,14,000 | 400 ₹1,52,000 | 800 ₹3,04,000 | 39 ₹14,820 Lowest |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
8 Aug 2025, 6:00 pmClosed
GE 881 EWS
GE 881 EWS, C/O 56 APO
REPAIR/ REPLACEMENT OF OLD RUSTED PIPE LINE, VALVESETC IN THE AOR OF AGE B/R-II UNDER GE 881 EWS
2025_MES_720086_1
GE/PNH-53/2025-26
Open Tender
Civil Works - Others
Item Rate
180 days
GE 881 EWS
AS PER DOCUMENTS
7 documents required · 7 mandatory
₹500
Yes
GE 881 EWS
₹80,000
Yes
11 Sept 2025
12 Jul 2025
13 Aug 2025
12 Jul 2025
8 Aug 2025
26 Jul 2025
Amount
Excavation in trenches not exceeding 1.50 m wide and not exceeding 1.50 m in depth for taking up or laying pipe in soft/loose soil and getting out complete all as specified and directed.
Returning, filling in trenches including spreading leveling, watering and ramming in layers (soil) not exceeding 25 cm without damaginlg pipes specials/CI specials, fittings complete all as specified and directed.
Removing of surplus spoil to a distance not exceeding 50 mtr and deposited where directed at a level not exceeding 1.50 m above the strating point complete all as specified and directed.
S&F in repair steel water tubing galvanised, medium grade with all fittings and fixed complete to walls, or in floors , in old / new situation for bore of pipe complete all as specified and directed for following sizes:-
20 mm bore.
25 mm bore.
40 mm bore
50 mm bore
S&F in repair steel water tubing galvanised, medium grade with all fittings, fixed and laid in trenches , in old / new situation for bore of pipe complete all as specified and directed for following sizes:-
20 mm bore.
25 mm bore.
40 mm bore
50 mm bore
80 mm bore
100 mm bore
150 mm bore
S&F in repair Gate / globe valves, cast copper alloy, screwed down, high pressure with crutch or butterfly handle screwed both ends for iron pipe or for union complete all as specified and directed for following size:-
20 mm bore.
25 mm bore.
40 mm bore
50 mm bore
M&L for construction of brick masonry valve pits of size 100 cm x 100 cm x 100 cm (internal dimension) complete including fabrication of mild steel cover made out of 3 mm thick MS sheet and angle iron frame made out of 40 mm x 40 mm x 6 mm thick and one side provided with hinges and another side provided with locking arranement as per TD drawing held in the office of Engg-in-charge including dismantling the existing unserviceable valve pit complete all as specifeid and directed.
All as per item No 20 above but size 90cm x 90cm x 90cm (internal dimension) complete all as specified and directed.
S&F in repair cast iron sluice valve 150 mm bore, conforming with IS -14846-2000, PN 1.6 with steel metal spindle both ends flanged and drilled with necessary holes for bolts incl jointing materials viz nuts, bolts, rubber gaskets etc with iron wheel head incl flanged joints and making necessary arrangements to fix in position, complete all as specified and direc ted
All as per Srl item No. 24 above but 100 mm bore complete all as specified and directed.
All as per Srl item No. 24 above but 80 mm bore complete all as specified and directed.
S&F in repair cast iron non return valve/reflux valve, 150 mm bore with by pass arrangement, complete all as specified and directed
All as per Srl item No. 27 above but 100 mm bore complete all as specified and directed.
All as per Srl item No. 27 above but 80 mm bore complete all as specified and directed.
All as per Srl item No. 27 above but 50 mm bore complete all as specified and directed.
S&F in repair air release valve 150mm bore, with two air outlets compplete all as specified and directed
All as per Srl item No. 31 above but 100 mm bore complete all as specified and directed.
All as per Srl item No. 31 above but 80 mm bore complete all as specified and directed.
Supply only chlorination chemical highly efficient (high strength) calcium hypochloride 65% to 70% chlorine content based granular disinfectant more stable in sealed container, no sodium/ iron/ mercury/ heavy metal contaminations, complete all as specified and directed. Note: (i) The contractor shall produce manufacturer's test certificate and purchase vouchers of calcium based granular disinfectant. (ii) Qty shown at column 3 will not accepted at one time as the material having lesser expiry period. (iii) The calcium based granular disinfectant shall be brought at site in sealed plastic container. (iv) Calcium based granular disinfectant shall be of approved make as approved by E-in-C's branch or HQ CENC.
S&F in repair nut and bolt of 16/17/19/20/24/26 No. size with fully threaded top to bottom, as required on site complete all as specified and directed by Engr-in-Charge.
S&F in repair neoprene rubber gasket suitable for flanges upto 150mm dia pipe not less than 3mm thick of any dia and size as per site complete all as specified and directed by Engr-in-Charge.
M&L for replacement of foot valve 100 mm bore cast iron flange/screwed with gasket complete all as specified and directed by Engr-in-Charge.
M&L for replacement of foot valve 80 mm bore cast iron flange/screwed with gasket complete all as specified and directed by Engr-in-Charge.
M&L for replacement of foot valve 50 mm bore cast iron flange/screwed with gasket complete all as specified and directed by Engr-in-Charge.
M&L for cutting ofexisting pipe and making arrangement for insertion of NRV and including replacement of NRV 80/100mm bore(PN-106) and including flange joint with 3 mm thick neorprene rubber gasket, necessary bolts,nuts and earth work complete all as specified and directed.
Supply and fix CI/DI flanged fittings such as bends. Tapers. Tee pieces (single & double branch) any type and angle/radius and straight connecting pieces but all ends flanged including Connecting pieces one end flanged and other socket or spigot and bell mouth pieces one end flanged other end tapering as bell mouth complete all as specified and directed.
Supply and fix in repair Pressure gauge 0-150 Psi for 4"dia, 0-14 kgs rating wit necessary accessories and testing complete all as specified and directed.
S&F in replacement of old U/S gland packing with new to the valves/pump sets etc. of any sizes/capacity complete with neoprene rubber gasket ,jointing material and incl nuts/bolts/washer of suitable size etc complete all as specified and directed.
M&L for leakage rectification by pumping/bailing out of back flow accumulated water in trenches, cutting of existing pipe and making threading / welding for repair/ replacement of U/S fittings, rubber gasket, saddle piece, nuts, bolts with washer etc., pipe in short lengths (up to 1.5 mtr) for addition and alteration upto 150 mm dia CI/DI/MS pipe and including replacement of fittings, rubber gasket, saddle piece, nuts, bolts with washer etc. complete all as specfied and directed. Note : pipe in short lengths (up to 1.5 mtr), high density rubber sheet, welding work and necessary exacavation & earth work as required for making it serviceable is deemed tobe included in the quoted rate.
M&L for PCC 1:3:6 (nominal mix) type C-1 M-10 1:3:6 using 20mm graded crushed stone aggregates , as for thrust block or in foundation filling and mass concrete for Haunching of pipe of any size complete all as specified and directed.
M&L in repair to replacement of dosing tank suitable for existing at site and as per recommended by manifacturer of declibac technology . All as specified and as directed by Engr-In-Charge.
M&L in repair to replacement of shaft with impellar of dosing pump suitable for existing at site and all as specified and as directed by Engr-In-Charge.
M&L in repair to replacement of coil 250V, 50 HZ, suitable for dosing pump as existing at site and all as specified and as directed by Engr-In-Charge.
M&L for replcement of submersible pump set of capacity 25 HP including motor three phase with 150 meter head and output LPS 3.5 with complete accessories all as per specified and directed by Engr-in-Charge
Supply, installation, comissioning and testing of electric driven centrifugal motor of capacity 40 HP, 1500 RPM and pump set of capacity 7 LPS, 320 Mtr head incl 80 mm suction and 65mm delivery line suitable for 40 HP motor, complete all as directed.
M&L in repair to replacement of roller assy,suitable for dosing pump as existing at site and all as specified and as directed by Engr-In-Charge.
M&L in repair to replacement of pump tube,suitable for dosing pump as existing at site and all as specified and as directed by Engr-In-Charge.
M&L in repair to replacement of Injection check valve of size 3/8",suitable for dosing pump as existing at site and all as specified and as directed by Engr-In-Charge.
M&L in repair to replacement of weighted suction line strainer of size 3/8",suitable for dosing pump as existing at site and all as specified and as directed by Engr-In-Charge.
M&L in repair to replacement of white suction/discharge tube of size 3/8",suitable for dosing pump as existing at site and all as specified and as directed by Engr-In-Charge.
M&L in repair to replacement of check valve suitable for dosing pump as existing at site and all as specified and as directed by Engr-In-Charge.
M&L in repair to replacement of connecting nut of size 3/8", suitable for dosing pump as existing at site and all as specified and as directed by Engr-In-Charge.
M&L in repair to replacement of connecting nut with adapter of size 3/8", suitable for dosing pump as existing at site and all as specified and as directed by Engr-In-Charge.
M&L in repair to replacement of ferrule of size 1/4", suitable for dosing pump as existing at site and all as specified and as directed by Engr-In-Charge.
M/S Farooq Ahmed Bhat (BID ID -3379889)
narayan construction (BID ID -3387127)
M/S MANHAS ENTERPRISES (BID ID -3385060)
VIKAS ENTERPRISES (BID ID -3386986)
M/S KABIR CHOUDHARY (BID ID -3385486)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .