| Sl No | Description | Qty | Unit | ROYAL ELECTRICAL CO. L1 | RISHABH ENGINEERS L2 |
|---|---|---|---|---|---|
| 1.01 | Wiring of light point /fan point/ exhaust fan point /call bell point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq. mm. FRLS PVC insulated copper conductor single core cable etc. as required. (DSR No. 1.10.3 Group C) | 60 | Point | 99,000 ₹99,000 Lowest | 1,17,000 ₹1,17,000 |
| 1.02 | Supply and fixing suitable size GI box with modular plate and cover in front on surface or in recess , including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. (DSR No. 1.32) | 25 | Each | 16,200 ₹16,200 | 14,500 ₹14,500 Lowest |
| 1.03 | Supply and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 in 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. (DSR No. 1.31) | 20 | Each | 10,500 ₹10,500 | 9,500 ₹9,500 Lowest |
| 1.04 | Wiring for circuit/submain wiring along with earth wire with the following size of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required. 2x2.5 sq. mm +1x2.5 sq. mm earth wire. ( DSR No. 1.14.2) | 360 | Meter | 1,08,000 ₹1,08,000 Lowest | 1,51,200 ₹1,51,200 |
| 1.05 | Wiring for circuit/submain wiring along with earth wire with the following size of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required. 2X4 sq. mm +1x4 sq. mm earth wire .(DSR No.1.14.3) | 270 | Meter | 95,310 ₹95,310 Lowest | 1,40,400 ₹1,40,400 |
| 1.06 | Wiring for circuit/submain wiring along with earth wire with the following size of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required. 2X6 sq. mm +1x6 sq. mm earth wire .(DSR No.1.14.4) | 180 | Meter | 86,040 ₹86,040 Lowest | 1,26,900 ₹1,26,900 |
| 1.07 | Wiring for circuit/submain wiring along with earth wire with the following size of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required. 4x10 sq. mm +2x6 sq. mm earth wire. (DSR No. 1.14.10) | 100 | Meter | 1,05,500 ₹1,05,500 | 88,000 ₹88,000 Lowest |
| 1.08 | Supply and fixing call bell/ buzzer suitable for single phase 230V, complete as required.(DSR No.1.38) | 1 | Each | 110 ₹110 Lowest | 185 ₹185 |
| 1.09 | Supply and fixing 6 way(4+18), Double door, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415V, on surface/recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, inter connections , powder painted including earthing etc. as required. (DSR No. 2.4.2) | 3 | Each | 1,560 ₹1,560 Lowest | 7,650 ₹7,650 |
| 1.10 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. - Single pole -(DSR No. 2.10.1) | 74 | Each | 20,350 ₹20,350 | 14,060 ₹14,060 Lowest |
Tender Value
Refer Docs
EMD Value
₹15,500
Closing Date
14 Aug 2026, 11:15 amClosed
Executive Engineer (EnM) M-8
Office of the Executive Engineer (EnM) M-8 Nangloi Phase-III, Near Maharaja Surajmal Stadium Metro Station New Delhi-110041.
Renovation / Electrification of New Avantika BPS and Old Avantika Online Booster in AC-06
2026_DJB_296491_1
NIT No.08 /EE(EnM)M-8/2026-27 Item 19
Open Tender
Civil Works
Works
30 days
Nangloi
Please refer Tender documents.
3 documents required · 3 mandatory
₹500
Account No SB 50448339804
₹15,500
Yes
24 Aug 2026
5 Aug 2026
14 Aug 2026
5 Aug 2026
14 Aug 2026
5 Aug 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1.01 | Wiring of light point /fan point/ exhaust fan point /call bell point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq. mm. FRLS PVC insulated copper conductor single core cable etc. as required. (DSR No. 1.10.3 Group C) | 60 | Point | 80 | ₹4,800 |
| 1.02 | Supply and fixing suitable size GI box with modular plate and cover in front on surface or in recess , including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. (DSR No. 1.32) | 25 | Each | 80 | ₹2,000 |
| 1.03 | Supply and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 in 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. (DSR No. 1.31) | 20 | Each | - | - |
| 1.04 | Wiring for circuit/submain wiring along with earth wire with the following size of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required. 2x2.5 sq. mm +1x2.5 sq. mm earth wire. ( DSR No. 1.14.2) | 360 | Meter | - | - |
| 1.05 | Wiring for circuit/submain wiring along with earth wire with the following size of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required. 2X4 sq. mm +1x4 sq. mm earth wire .(DSR No.1.14.3) | 270 | Meter | - | - |
| 1.06 | Wiring for circuit/submain wiring along with earth wire with the following size of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required. 2X6 sq. mm +1x6 sq. mm earth wire .(DSR No.1.14.4) | 180 | Meter | - | - |
| 1.07 | Wiring for circuit/submain wiring along with earth wire with the following size of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required. 4x10 sq. mm +2x6 sq. mm earth wire. (DSR No. 1.14.10) | 100 | Meter | - | - |
| 1.08 | Supply and fixing call bell/ buzzer suitable for single phase 230V, complete as required.(DSR No.1.38) | 1 | Each | - | - |
| 1.09 | Supply and fixing 6 way(4+18), Double door, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415V, on surface/recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, inter connections , powder painted including earthing etc. as required. (DSR No. 2.4.2) | 3 | Each | - | - |
| 1.1 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. - Single pole -(DSR No. 2.10.1) | 74 | Each | - | - |
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.82 MB
BOQ_394691.xls
BOQ • 0.27 MB
Corrigendum08.pdf
PDF • 0.28 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .