| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.6 LAccepted-AOC 150 BC LINE MALL ROAD MEERUT CANTT 250001 | MEERUT | UTTAR PRADESH | 250001 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹5.0 L+₹1.2 L (33.5%)Rejected-Finance H NO 07 SHIVAJI NAGAR PATHANKOT 145001 | PATHANKOT | PATHANKOT | PUNJAB | 145001 | L2 | Rejected-Finance Being not L1 | |
| 3 | L3₹5.0 L+₹1.2 L (33.5%)Rejected-Finance M S KEWAL SONS SHIVA JI NAGAR GALI NO 1 MODEL TOWN PATHANKOT PUNJAB 145001 | PATHANKOT | PUNJAB | 145001 | L3 | Rejected-Finance Being not L1 |
Tender Value
Refer Docs
EMD Value
₹10,000
Closing Date
8 Nov 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
AGE(I) Dalhousie 176305
AGE(I) Dalhousie 176305
CERTAIN MAINT WORK TO REFRIGERATOR AC COOLING APPLIANCES AND OTHER MISC WORK AT DALHOUSIE and BAKLOH AREA
2021_MES_468356_3
8809/2021-22/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
AGE(I) Dalhousie
Please refer Tender documents.
8 documents required · 8 mandatory
₹300
Yes
AGE(I) Dalhousie
₹10,000
Yes
AGE(I) Dalhousie 176305
24 Dec 2021
16 Oct 2021
10 Nov 2021
16 Oct 2021
8 Nov 2021
25 Oct 2021
16 Oct 2021 - 20 Oct 2021
20 Oct 2021
60 days
Amount
M&L for general servicing / repairs / maintenance by authorised dealer/ represntative of cold storage unit by leak testing with N- 2 gas under constant pressure of 250 PSI after complete transfer of refrigerant gas from the entire system, rectification of leakage by cutting and brazing the refrigeration system wherever required. Replacement of 'O' Ring tefflonwasher of valves copper tubing, safety valves, flare nuts etc. Neutralising after the pressure hold good for atleast 24 hours vaccumisation, charging the system with refrigerant gas including complete testing at site all as specified and directed. Note:- Gas charging including in the quoted rate and no extra payment to be made.
M&L for general servicing / repairs / maintenance by authorised dealer/ represntative of cold storage unit by tightening / rectification of electric circuit of all units and controll wiring , phase seqquence, including replacement of fused indication lamp, cleaning of all power contacts, rectification of minor defects complete testing at site all as specified and directed.
M&L for general servicing/ repair and maintenance of window type AC's of capacity 1.5/2.0 TR comprising of the following tasks at different location of any condition and transporting to contractor workshop to carry out necessary repair including refixing at site, commissioning, testing, painting of AC's and writing of MES Number complete all as specified and directed :- (i) Inspecting, taking down, brushing cleaning with blower including acid/detergent wash of condenser and cooling coil. (ii) Carry out running test of operation of blower and compressor and ensure that satisfactory functioning of all parts. (iii) Inspecting for leakage in the system. (iv) Checking the earth continuity of electrical parts. (v) Checking the functioning of thermostat. (vi) Inspection of electrical parts. (vii) Testing the machine for satisfactory operation. Note:- (i) Any part found unserviceable / defective shall be measured and paid separately under respective item here-in-after. (ii) Make of parts shall be as per original window type AC.
S&F in replacement of air filter of window type AC 1.5/2.0 TR capacity asper existing Make & Model as required at site complete all as specified and directed. Make: - Coir foam or equivalent make ISI marked.
S& F in replacement of cooling coil as per existing Make and Model suitable for 1.5/2.0 TR capacity window air conditioner commissioning & testing complete all as specified and directed.
S&F in replacement of fan & blower motor as per existing make & model & suitable for 1.5/2.0 TR capacity window air conditioner complete all as specfied and directed.
S&F in replacement of fan blade as per existing make & model & suitable for 1.5/2.0 TR capacity window air conditioner complete all as specified and directed
M&L for charging of Refrigerant (R-22) to 1.5/2.0 TR Air conditioner up to maintain reqd temperature as per site condition complete all as specified and directed. Note :- (i) Refrigernat (R-22) shall be deemed to be included in the quoted rate. (ii) Empty / filled cylinder shall be responsibility of contractor and he shall be liable for all risk against same deemed to be including in the quoted rate.
S&F in repair compressor Hermatically sealed unit suitable for 1.5/2.0 TR AC window type ISI marked suitable for working on 230 volts single phase including filling of gas R-22 of required quantity including testing on full load complete all as specified and as directed. make- Emerson copland or equivalent approved make.
S& F in replacement of Running capacitor 36/45 MFD. Make: Usha/ Caital/ Epcos or equivalent complete all as specified and directed.
S& F in replacement of Starting capacitor 80/100 MFD. Make: Usha/ Caital/ Epcos or equivalent complete all as specified and directed.
S&F in replacement of Electronic circuit board for window type air conditioners suitable for 1.5 Ton AC window type ISI marked as per the existing make complete all as specified and directed..
S&F in replacement of Gas filter for 1.5/2.0 Ton AC make: Vijay /Goldstar
S&F in replacement of Thermostat switch for 1.5/2.0 Ton AC make: Renutrol/Indfoss complete all as specified and directed.
S&F in replacement of Front grill suitable size Make: Gem/Usha/Fedferlloyed/ Carrier air conditioner.
M&L for general servicing/repair & maintenace of Refrigerator 165 to 320 Ltr capacity comprising of the following tasks at different location and disconnecting and taking out unserviceable parts such as relay over load, thermostat, gas filter, bulb etc including fixing new parts with new nut bolts and washers etc re-assembling the refrigerator after repairing and testing complete including welding / Brazing works where ever required complete all as specified and as directed including and transporting to contractor workshop to carry out necessary repair complete all as specified and directed :- (i) Inspecting, taking down, brushing cleaning with blower including acid/ detergent wash of condenser and cooling coil. (ii) Carry out operation of blower and compressor and ensure that satisfactory funtioning of all parts. (iii) Inspecting the leakage in the system. (iv) Checking of the earth continuity of electrical parts. (v) Checking the functioning of thermostat (vi) Inspection of all electrical parts (vii) Testing the machine for satisfactory operation. (viii) Check and correct all electrical wiring & test its functioning. (ix) Testing of Refrigerator after repair. Note:- (i) Any parts found unservicable/defective shall be measured and paid separately under respectivel item here-in-after. (ii) Make of parts shall be as per original Refrigerator.
Supply and fixing in repair of the follwing spare parts for repalcement of the unserviceable items:
(a) PTC relay OLP HE 48/115 (Make: Whirlpool / Classic / Godrej / LG)
(b) Door handle suitable for 165 - 310 Ltrs capacity refrigerators.
(c) Overload protector for refrigerator 1/6 HP (Make: Whirlpool / Classic / Godrej / LG)
(d) Overload protector for refrigerator 1/8 HP (Make: Whirlpool / Classic / Godrej / LG)
(e) Rubber door beeding gasket set suitable for 165-310 Ltr refrigerateor
(f) Thermostat suitable for 165-30 Ltr refrigerator (Make: Ranutrol /Indfoss)
(g) Bulb for refrigerator 15 watt 220 volt, pin type Make: Bajaj /Omex/Philips
(h) Bulb for refrigerator 15 Watt, 220 Volt, screw type Make: Bajaj/Omex/Philips
(j) Ice tray (PVC superior quality)
(k) Bottle self for refrigerator.
(m) Suprerior quality Plastic multipurpos storage container .
(n) Transparent plastic refrigerator tray .
S&F in replacement of burnt compressor Company make original as per existing Make & model & suitable for refrigerator of capacity 165-190 Ltr complete all as specified and directed. Gas charging will be measured and paid saparately.
S&F in replacement of burnt compressor Company make original as per existing Make & model & suitable for refrigerator of capacity 215-310 Ltr complete all as specified and directed . Gas charging will be measured and paid saparately.
Disconnecting and taking down refrigerator (165 to 320 Ltr Cap) of any make and size for repairs & including detecting of leakage in the system rectifying the same, dehydration & recharging of gas (R-134a) & testing the refrigerator for smooth & satisfactory operation complete all as specified and directed .NOTE:- (i) Filling / recharging of gas (R-134a) shall be deemed to be included in the quoted rate (ii) Empty / filled cylinder shall be responsibility of contractor and he shall be liable for all risk against same deemed to be included in the quoted rate.
S&F in repair ice chamber (Freezer) for 165 / 175 /285 /300 /315 Ltr refrigerator surrounded by frezzer pipes complete all as specified and as directed . Make : Whirlpool / Kelvinator / Godrej /LG
Supply and fixing in replacement of cooling coil for 285 / 300 / 310 Ltr of any make refrigerator. Make: Whirlpool / Godrej/LG
Supply and fixing in replacement of cooling coil for 165/175 Ltrs of any make refrigeratror. Make: Whirlpool/Godrej/LG
Supply & fixing in replacement of single phase, wall mounted copper wound, air cooled type with digital display of output voltage 220V ± 9% and calibration accuracy ± 3% Voltage stablizer 5 KVA, range of 170-260V all as specified and directed by Engr-in-Charge. Make:- Volina / V Guard / Aplab
M&L for opening of the stablizer/A/C protectors, removing of the all internal parts, replaceing of the unserviceable PCB, rewidning of T/F replacement of indicating lamp, volt meter fuse cutout, relay reocnnecting back and testing complete of the following size all as specified and directed.
(a) 0.5 KVA capacity
(b) 1 KVA capacity
(c) 5 KVA capacity
M&L for general servicing/repair & maintenace by authroised dealer/ representative of Deep Freezer 300 to 320 Ltr capacity comprising of the following tasks at different location and disconnecting and taking out unserviceable parts such as relay over load, thermostat, gas filter, bulb etc. including fixing new parts with new parts with new nut bolt and washers etc reassembling the Deep Frezzer after repairing and testing complete including welding / Brezing works where ever required complete all as specified and as directed including and transporting to contractor workshop to carry out necessary repair complete all as specified and directed :- (i) Inspecting, taking down, brushing cleaning with blower including acid/detergent wash of condenser and cooling coil. (ii) Carry out operation of blower and compressor and ensure that satisfactory functioning of all parts. (iii) Inspecting the leakage in the system (iv) check and correct all electrical parts. (vii) Testing the machine for satisfactory operation. (viii) Check and correct all electrical wiring & test its functioning (ix) Testign of Refrigerator after repair. Note:- (i) Any parts found unserviceable/defective shall be measured and paid separately under respectivel item here-in-after. (ii) Make of parts shall be as per original Deep Freezer.
S&F in repair compressor Hermatically sealed unit suitable for 320 Ltr deep freezer of existing make suitable for working on 230 volts single phase with filling of gas R-22 of required quantity including testing on full load complete all as specified and directed.
Supply and replacing old u/s cable and fixing of PVC cooper cable 4 sqmm 3 core for all connection with stablizer, refrigerator, deep freeaers all as specified and directed by Engineer-in-Charge.
S&F sheet metal enclosure with single pole and neutral enclosure with 2 pin and earth plug and socket complete with one single pole MCB of capaicty, 20 Amps 230 Volts including removing of the old U/S all as directed Make:- Stanard.
S&F plug top 3 pin 5 Amps 230 Volts including removing of the old U/S all as directed.
All as per item No.30 above but 15 Amps
M&L for writing SM No. MES No. etc. on Refrigerator, Deep freezer & AC at site approved shade/color of synthetic enamel paint , hight of letter 20/40 mm and up to 20 Nos in words/Figures complete all as specified and directed
M&L for display board for hard plywood board and on the board fixingin of 3mm colored Acrylic sheet with PVC bedding around the board and writing 20/40 mm hight illuminated pasted letter for writting of " AGE (I) DALHOUSIE COLD STORAGE ROOM (SUPPLY DEPOT) " on top of the board with one side MES Logo and another side div sign paste on the board and below complete details of Cold storage, Name of Inatalltion, MES No., SM No, Date of Installation, Capacity etc complete with fixing arrangement of the board on wall surface by using of MS flat, Nut, bolt ,anchor fastioner etc complete all as specified and directed by Engineer-in-Charge.
Material and Labour for Earthing complete with galvanised steel earth plate electrode 60cm x 60 cm x 6 mm thick burried directly in ground any type of soil including rock soil alos (earth pit not less than 2.25 Mtr below ground level) with top edge of plate not less than 1.5 Mtr below normal ground level connected to galvanised iron strip 25 x 4 mm as earthing lead by means of bolts, nuts, check nuts, as earth lead complete including 40mm bore dia protection pipe GI medium grade upto 7.5 mtr length, watering pipe 15mm bore dia GI medium grade 1.70m length, charcoal & salt filling, necessary earth work in any type of soil including rocky soil also, concrete pit, funnel removal of surplus soil upto 50m distance all as per electrical plate No.3 of SSR Part-I and connected to earthing test point, main board including testing on completion all as specified and as directed by Engr-in-charge.
S&F in Test point terminal block made of gun metal or phosphorus bronze size 75x75x5mm drilled and screwed including 3 nos. 8 mm dia 25 mm long hex. head screw complete all as specified and directed by Engr-in-Charge.
S & F in replacement aluminium strip of size 25 x 3.15 mm fixed with porcelain/PVC saddles and fixing screws etc minimum tow number saddles with screws on and including PVC guttis in each one mtr of length for roof conductors and down conductor above ground complete all as specified and directed
S&F in replacement of air termination single pointed aluminium rod 12 mm dia and 300 mm long and fixed including taking out old ari termination rod complete all as specified and directed.
Supply and fixing GI tubing medium grade galvanized will fitting laid in trench 20 mm dia bore all as specified.
Supply and fixing bib tap cast copper alloy with crutch or butterfly handle screw down, screwed for iron pipe of for brass ferrule and fixed 15mm bore all as specified and directed by EIC
Supply and fixing stop valve 20mm dia cast copper alloy screw down high pressure with cructh or butter fly handled screwed both ends for iron pipe or for union all as specified.
Supply and installed Rotational mounted polyethelene water storage tank cylindrical vartical with closed top 500 Ltr capacity all as specified.
Supply and fixing Ball brass valves high pressure with polythene flote and flynut complete secewed for iron pipe or brass feerrule 20mm dia all as specified.
M&L Rolled mild steel in compound girders and stanchions lattice girders, arial masts, staging for water tanks and the like including caps , bases, splices etc. built up from two or more beam or channel sections or angles with plates including all lattice bars, stiffeners, gusset plates, etc. conforming to Fe 410-W (Gde-E-250) quality -A,for 500 Ltr tank steel stagging cmplete all as specified and directed by Engineer-in-Charge.
M&L Cement concrete in foundation/grounting of steel staging for 500 Ltr water tank filling and mass concrete type F-2 ,1:7:12 (40mm graded) all as specified.
Supplying, fixing, jointing, connecting & testing in trenches XLPE/PVC insulated PVC sheathed cable heavy duty 1100 volts grade, aluminum conductor in trenches / ducts /on wall surface as in repairs/replacement of old unserviceable cable of following sizes all as specified and directed.
(a) 2 core 16 Sqmm
(b) 4 core 16 Sqmm
M&L for sand cushioning for cable protection 8 cm below the cable and 15 cm above the cable complete all as specified and directed
Supply and lay burnt bricks sub class `B’ of size 230x115x75mm laid dry over sand cushioning in trenches as protection on the cable all as directed
Excavation in trenches in any type of soil n. exc 1.5mtr wide and n. exc 1.5mtr depth for GI tubing and getting out in Hard/dense soil all as specified.
M&L for returning, filling in including sperading, leveling watering and well ramming in layers n. exc 25 cm thick each layers in soil all as specified and directed.
M&L for removal of surplus soil to a distance not exceeding 50 mtr and deposting where directed and at a level not exceeding 1.5 mtr above the starting point all as specified and directed by Engr-in-Charge.
M/s Shakti Electric Works
KEWAL SONS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .