Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.7 LAdmitted-Finance | ₹4.7 L | L1 | Admitted-Finance |
| 2 | L2₹5.5 L+₹78,992.74 (16.9%)Admitted-Finance | ₹5.5 L+₹78,992.74 (16.9%) | L2 | Admitted-Finance |
| 3 | L3₹5.7 L+₹1.1 L (22.8%)Admitted-Finance | ₹5.7 L+₹1.1 L (22.8%) | L3 | Admitted-Finance |
| 4 | Rejected-Technical | - | - | Rejected-Technical EMD/FDR not submitted |
| Sl No | Description | Qty | Unit | Raj Engineering Co. L2 | Avon Electricals L1 | Gupta Brothers L3 |
|---|---|---|---|---|---|---|
| 1.00 | Dismantling of old damaged panel, removing of cable connection, & shifting the same by heavy labour at DJB store. | 1 | Job. | 5,500 ₹6,490 Lowest | 9,153 ₹10,800.54 | 15,000 ₹17,700 |
| 2.00 | Supply and Erection of LT Distribution Panel-cum-MCC Panel Board of suitable capacity and size, designed for 415 Volts, 3 Phase, 4 Wire, 50 Hz AC supply system. The panel shall be fabricated in compartmentalized design using 2 mm thick CRCA sheet steel, totally enclosed, powder coated, free-standing, floor-mounted type, dust and vermin proof, with outward-opening and lockable doors having concealed hinges and a bolted back cover. The doors and back cover shall be provided with non-deteriorating neoprene rubber gaskets to ensure IP-54 degree of protection.
Each fabricated part of the panel shall be subjected to complete seven-tank treatment process before painting. The various components, assemblies and sub-equipment of the panel shall conform to the relevant Indian Standards (IS) and CPWD specifications. The panel shall be provided with high-conductivity electrolytic aluminium bus bars of adequate and liberal cross-section, suitably sized for the rated current and fault level of the panel.
The control wiring shall be carried out with 1.5 sq. mm PVC-insulated flexible copper wires. Each wire shall be properly terminated with suitable ferrules, crimped securely to the wire, and all internal wiring shall be neatly arranged and suitably identified. The overall approximate size of the panel shall be 1500 mm × 1200 mm × 375 mm.
The panel shall be provided with components and accessories of approved make, conforming to CPWD specifications, and shall comprise the following arrangements and controls:
(1) 02 Nos. Incomers, comprising one incomer for the Main Supply and one incomer for the DG Supply, with suitable interlocking/changeover arrangement as required.
(2) 04 Nos. 20 HP Star/Delta Starters for operation and control of 20 HP Pump-sets
(3) 02 Nos. Star/Delta Starters for operation and control of upto 35 HP submersible Pump-sets
(4) 02 No. 05 HP DOL Starter for operation and control of the 05 HP Dewatering Pump-sets
(5) Internal/External Lighting Load with suitable outgoing feeder and control arrangement.
(6) 01 No. Spare Cabinet/Compartment for future provision and expansion.
NOTE: DRAWING SHALL BE GOT APPROVED FROM ENGINEER IN-CHARGE BEFORE FABRICATION
The above panel board should have following components of DJB approved make. | 1 | No. | 1,01,000 ₹1,19,180 | 1,23,000 ₹1,45,140 | 70,000 ₹82,600 Lowest |
| 3.00 | MCCB 415V, Four Pole High breaking capacity 36KA 50Hz,400Amp with spreader - Make L&T/Schneider/C&S/DJB approved make | 1 | No. | 27,000 ₹31,860 | 24,492 ₹28,900.56 Lowest | 40,000 ₹47,200 |
| 4.00 | MCCB 415V, TP 3phase High breaking capacity 36KA 50Hz,100Amp with spreader - Make L&T/Schneider/C&S/DJB approved make | 2 | Nos. | 11,800 ₹13,924 | 11,356 ₹13,400.08 Lowest | 20,000 ₹23,600 |
| 5.00 | MCCB 415V, TP 3phase High breaking capacity 36KA 50Hz,63Amp with spreader - Make L&T/Schneider/C&S/DJB approved make | 4 | Nos. | 23,600 ₹27,848 | 22,712 ₹26,800.16 | 20,000 ₹23,600 Lowest |
| 6.00 | MCB Single pole 6Amp. Make L&T/Schneider/C&S/DJB approved make | 6 | Nos. | 1,260 ₹1,486.8 | 780 ₹920.4 Lowest | 1,080 ₹1,274.4 |
| 7.00 | MCB Triple pole 63Amp. Make L&T/Schneider/C&S/DJB approved make | 2 | Nos. | 2,900 ₹3,422 | 2,520 ₹2,973.6 | 1,600 ₹1,888 Lowest |
| 8.00 | MCB Triple pole 32Amp. Make L&T/Schneider/C&S/DJB approved make | 1 | Nos. | 950 ₹1,121 | 1,140 ₹1,345.2 | 400 ₹472 Lowest |
| 9.00 | Over load relay 36-60 amp Make L&T/Schneider/C&S/DJB approved make | 2 | Nos. | 8,600 ₹10,148 | 9,810 ₹11,575.8 | 6,000 ₹7,080 Lowest |
| 10.00 | Over load relay 20-33 amp Make L&T/Schneider/C&S/DJB approved make | 4 | Nos. | 15,600 ₹18,408 | 10,440 ₹12,319.2 Lowest | 12,000 ₹14,160 |
Tender Value
Refer Docs
EMD Value
₹13,500
Closing Date
14 Sept 2026, 3:00 pmClosed
EXECUTIVE ENGINEER (EM) M-16
GREATER KAILASH, PART-I, NEW DELHI
Replacement of LT Panel with all other allied work at Sukhdev Vihar SPS in Kalkaji Constituency AC-51.
2026_DJB_298019_4
NITNo.2/EE(EM)M-16/(26-27)
Open Tender
Electrical Work/ Equipment
Works
30 days
EXECUTIVE ENGINEER (EM) M-16
Please refer Tender documents.
3 documents required · 3 mandatory
₹500
DELHI JAL BOARD
₹13,500
Yes
22 Sept 2026
5 Sept 2026
14 Sept 2026
5 Sept 2026
14 Sept 2026
5 Sept 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount | GST % |
|---|---|---|---|---|---|---|
| 1 | Dismantling of old damaged panel, removing of cable connection, & shifting the same by heavy labour at DJB store. | 1 | Job. | 80 | ₹80 | 18% |
| 2 | Supply and Erection of LT Distribution Panel-cum-MCC Panel Board of suitable capacity and size, designed for 415 Volts, 3 Phase, 4 Wire, 50 Hz AC supply system. The panel shall be fabricated in compartmentalized design using 2 mm thick CRCA sheet steel, totally enclosed, powder coated, free-standing, floor-mounted type, dust and vermin proof, with outward-opening and lockable doors having concealed hinges and a bolted back cover. The doors and back cover shall be provided with non-deteriorating neoprene rubber gaskets to ensure IP-54 degree of protection.
Each fabricated part of the panel shall be subjected to complete seven-tank treatment process before painting. The various components, assemblies and sub-equipment of the panel shall conform to the relevant Indian Standards (IS) and CPWD specifications. The panel shall be provided with high-conductivity electrolytic aluminium bus bars of adequate and liberal cross-section, suitably sized for the rated current and fault level of the panel.
The control wiring shall be carried out with 1.5 sq. mm PVC-insulated flexible copper wires. Each wire shall be properly terminated with suitable ferrules, crimped securely to the wire, and all internal wiring shall be neatly arranged and suitably identified. The overall approximate size of the panel shall be 1500 mm × 1200 mm × 375 mm.
The panel shall be provided with components and accessories of approved make, conforming to CPWD specifications, and shall comprise the following arrangements and controls:
(1) 02 Nos. Incomers, comprising one incomer for the Main Supply and one incomer for the DG Supply, with suitable interlocking/changeover arrangement as required.
(2) 04 Nos. 20 HP Star/Delta Starters for operation and control of 20 HP Pump-sets
(3) 02 Nos. Star/Delta Starters for operation and control of upto 35 HP submersible Pump-sets
(4) 02 No. 05 HP DOL Starter for operation and control of the 05 HP Dewatering Pump-sets
(5) Internal/External Lighting Load with suitable outgoing feeder and control arrangement.
(6) 01 No. Spare Cabinet/Compartment for future provision and expansion.
NOTE: DRAWING SHALL BE GOT APPROVED FROM ENGINEER IN-CHARGE BEFORE FABRICATION
The above panel board should have following components of DJB approved make. | 1 | No. | 80 | ₹80 | 18% |
| 3 | MCCB 415V, Four Pole High breaking capacity 36KA 50Hz,400Amp with spreader - Make L&T/Schneider/C&S/DJB approved make | 1 | No. | 80 | ₹80 | 18% |
| 4 | MCCB 415V, TP 3phase High breaking capacity 36KA 50Hz,100Amp with spreader - Make L&T/Schneider/C&S/DJB approved make | 2 | Nos. | 80 | ₹160 | 18% |
| 5 | MCCB 415V, TP 3phase High breaking capacity 36KA 50Hz,63Amp with spreader - Make L&T/Schneider/C&S/DJB approved make | 4 | Nos. | 80 | ₹320 | 18% |
| 6 | MCB Single pole 6Amp. Make L&T/Schneider/C&S/DJB approved make | 6 | Nos. | 80 | ₹480 | 18% |
| 7 | MCB Triple pole 63Amp. Make L&T/Schneider/C&S/DJB approved make | 2 | Nos. | 80 | ₹160 | 18% |
| 8 | MCB Triple pole 32Amp. Make L&T/Schneider/C&S/DJB approved make | 1 | Nos. | 80 | ₹80 | 18% |
| 9 | Over load relay 36-60 amp Make L&T/Schneider/C&S/DJB approved make | 2 | Nos. | 80 | ₹160 | 18% |
| 10 | Over load relay 20-33 amp Make L&T/Schneider/C&S/DJB approved make | 4 | Nos. | 80 | ₹320 | 18% |
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.82 MB
BOQ_397274.xls
BOQ • 0.27 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .