Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.1 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹19.3 L+₹19,563 (1.02%)Rejected-Finance | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹21.5 L+₹2.4 L (12.4%)Rejected-Finance | L3 | Rejected-Finance Other than L1 | |
| 4 | L4₹23.5 L+₹4.4 L (22.9%)Rejected-Finance | L4 | Rejected-Finance Other than L1 | |
| 5 | L5₹23.8 L+₹4.7 L (24.7%)Rejected-Finance | L5 | Rejected-Finance Other than L1 |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
23 Dec 2019, 6:00 pmClosed
GE North Akhnoor
GE North Akhnoor
SPL REPAIR TO BLDG NO TR 05 AND PROVN OF SIDE HIGH WALL AT AP AND PROVN OF DRAINAGE LINE AND DRAINAGE SYSTEM AT FD WKSP AT AKHNOOR UNDER GE NORTH AKHNOOR
2019_MES_300080_1
GE(N)/AKH-39/2019-20
Open Tender
Civil Works
Item Rate
180 days
Akhnoor
E Class Cat a i b i
8 documents required · 8 mandatory
₹500
GE North Akhnoor
₹50,000
Yes
2 Apr 2020
22 Nov 2019
24 Dec 2019
22 Nov 2019
23 Dec 2019
7 Dec 2019
Amount
Dismantling asbestos cement (corrugated or semi corrugated etc) sheet in roof covering including ridges, all as directed.
Pre-painted galvalume aluminum zinc coating GI based profile steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws, complete all as specified & directed.
Pre-painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in as in ridges, hips, valley gutters, drip and straight flashings, fixed with self tapping screws, complete all as specified & directed.
Mild steel rolled work as in roof trusses ( framed) , trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing( Beam, tee, angle, channel or flat sections ) including distance pieces, cleats etc. , conforming to grade Fe 290-W Gde-E-165 all as specified.
Preparation of new steel surfaces of any description exc 10 cm width or girth and painting with two coats of synthetic enamel paint over one coat of zinc chromate primer complete, all as specified.
Taking down cement plaster on brick or stone surfaces etc. including raking out joints, hacking for key, scrubbing down with water etc, complete all as specifed & directed.
15mm thick rendering in cement mortar 1:4 on fair faces of brick surfaces or concrete surfaces, surface finished even and smooth without using extra cement, with water proofing compound complete all as specified & directed.
10mm thick rendering in cement mortar 1:6 on fair faces of brick work or concrete surfaces, finished even and smooth without using extra cement, complete all as specified.
Preparation of newly plastered surfaces of walls and applying 3mm thick wall putty with fair finish and applying two coats of oil bound distemper complete all as specified
Preparation of new surfaces and apply two coat of cement base paint to walls including one coat of cement primer complete all as specified and directed.
Preparation of new surfaces and apply one coat of acrylic emulsion exterior paint on wall/ceilings/facia complete all as specified and directed.
GI frame work 605 x 605 mm for seamless ceiling comprising of GI perimeter channel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre / intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soft it at approx x 900 mm centre to centre with GI cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50mm and flange of 26mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 centre to centre including 4 mm thick non acbestos designer building board in grid complete all as specified.
Demolition of cement concrete (un-reinforced) in ground floors and paving not exceeding 15cm thickness (below or above ground level) , complete all as specified & directed.
50 mm thick PCC type C-1 1:3:6 (using 20mm graded stone aggregate) as in plinth protection laid in bays complete including 75mm thick consolidated hard core of broken stone over rammed earth finishing the surface of concrete topping even & fair, without using extra cement filling the joints with mastic filling comprising of one part of heated bitumen 85/25 or 95/10 grade and 3 parts of sand (all by weight) complete all as specified and as directed by Engineer-in-Charge. Note :- The rate quoted shall be deemed to include for use and waste of form work/screed strips and to divide the area in panels.
25 mm thick PCC 1:2:4 type B-0, using 12.5 mm graded stone aggregate, as in sub base of floor complete all as specified
Vitrified ceramics coloured tiles 10mm thick polished, area of each tiles n.exc 0.36 Sqm laid as in floors /skirting etc, set and jointed in neat cement slurry and pointed in whitc/coloured cement to match in light shade incl 10mm thick double charged screed bed/base in CM 1:4 complete all as spd and directed.
Chequerred cement concrete tiles 25 cm x 25 cm x 22 mm thick with grey cement and pigment, set, jointed and pointed in neat cement slurry in floors over and including 20 mm thick screed bed in cement and sand mortar 1:4 complete all as specified.
75mm thick PCC (1:5:10) type E2 (40mm graded stone aggregate) in as in sub base of floor, complete all as specified.
Taking down chowkats or frames including shutters (without taking off shutters from the frame) exc. 1.5 Sqm but n exc 4.0 sqm each, complete all as specified & directed.
Taking down chowkats or frames including shutters (without taking off shutters from the frame) not exc. 1.5 Sqm each, complete all as specified & directed.
Pressed steel frames (factory made) of size 125mmx60mm made out of 1.25mm thick MS sheet for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, bottom of each frame to be welded with 02 Nos. 25x25x3mm angle iron projecting 10cm on either side and PCC 1:3:6 type C-0 using 12.5mm graded crushed stone aggregate for filling of hollow portion, complete all as specified & directed.
Factory made HDF prelaminated moulded door shutter 30 to 35mm thick (stile) with 2, 4 or 6 raised panel design with fibre raised 3.2mm thick moulded prelam HDF sheet on the front face and back prelam plain sheet PUF filled door shutters with PUF (Polyurethane foam) insulation of minimum density 40 kg/cum, supplying and fixing in the frame at site as per specifications. Make : Teechno feb India Ambala, HR Enterprises Pathankot, Seipal Mumbai.
30mm thick 2nd class hard wood (Sal/Hollock), glazed and skeleton shutters (factory made), open rebated and prepared to receive glass or gauge etc., (without sash bars), edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass etc., size of members of shutters as specified in clause 8.24 (a) of SSR Part-I, complete all as specified & directed.
Painting to new wood or wood based surfaces of any description not otherwise described over 10 cm in width or girth including preparation of surfaces, priming with pink primer (one coat) finished with two coats of synthetic enamel paint complete all as specified
300 mm size mild steel ordinary rat tail rod pattern springs including roller and roller plate, ISI marked complete all as specified.
Aluminium handles fabricated type anodised of size 150 mm long ISI marked complete all as specified.
200mm long, aluminium anodised, barrel tower bolts, of extruded section ISI marked complete all as specified.
250mm long aluminium alloy anodised sliding door bolt with hasp staple, bolt type, and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded section or cast aluminium alloy, ISI marked complete all as specified.
IInd class hard-wood, small fittings such as bracket of any sizes, hinge blocks, cleats, door/window stoppers and like articles not exceeding 200 cubic centimetres each complete all as specified.
Galvanized mild steel wire-cloth 0.45 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with tinned tacks or galvanised wire staples complete all as specified.
03 mm thick sheet glass, ordinary quality and glazing with oil putty/wooden beads in square not exceeding 0.5 square metre in each pane complete all as specified.
Floor door stopper 150mm length of aluminium alloy body and tongue anodised with hard drawn steel spring fixed in floor complete all as spd.
Steel windows/ventilator (Box type) factory made with double shutter (wire gauged shutter & glass/glazed shutter, (wire cloth and glass panes shall be measured and paid separately) of size 79mmx39mm,16 gauge rectangular tubular frame with side hung shutter with glazing bars 12x3mm flat iron incl box type hinges with steel handle and steel peg stay dovetailed or welded incl 2 Nos tower bolts 100mm long and 10mm square bar grills complete, two coats of synthetic enamel paint over one coat of red oxide primer including taking down old windows/ventilators all as specified & as shown on drg No. CEUZ/TD/1269/2008 Sh no 1/1 to 1/3 .
Supply only integral water proofing compound, complete all as specifed & directed.
Demolition of brickwork or stone boulder masonary built in cement or cement lime mortar including all quoins, arches, pillars etc complete all as specified and as directed by Engineer -in-Charge.
Brick work with Sub Class ‘B’ burnt bricks (Old size bricks) straight or curved on plan exceeding 6 m mean radius built in cement mortar 1:6 complete, all as specified.
Ditto all as per item No. 36 here in before but except brick.
Curtain rail, 20 mm dia anodised aluminium alloy ,cromium plated fixed with braket, incl taking down of old curtain rods, all as directed.
Surface excavation not exceeding 30cm deep and averaging 15cm deep and getting out in any type of soil, all as specified.
Hard core of broken stone or boulder of gauge not exceeding 63mm, deposited, spread and levelled in layers not exceeding 15cm thick, watered and rammed to a true surface.
100mm thick cement concrete type B2 1:2:4 (40mm graded aggregate) finished the surface even and fair with out using extra cement.
Forming 12mm thick expansion joints filled with pre-formed bituminous filler and top 30mm primed and sealed with sealing compound, grade B (thickness of concrete slab is 100mm) complete all as specified and directed by Engr-in-Charge.
Brick work with Sub Class ‘B’ burnt bricks (Old size bricks) straight or curved on plan exceeding 6 m mean radius built in cement mortar 1:4 complete, all as specified.
Excavation in post holes ( or similar holes) in any type of soil, each not exc 0.50 cum, getting out, removing surplus spoil to distance not exceeding 50 mtr and making good surface complete all as specified.
PCC (1:2:4) type B-2 (using 40mm graded crushed stone aggregate) as in foundations filling and mass concrete complete all as specified and as directed by Engineer-in-Charge
Hand rails, half round or other stock section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-410-0 or Fe 310-0
Mild streel screw bolts (machine made) with hexagonal or square heads at one end and screwed at the other end, or screwed both ends, each screwed end to be fitted with one hexagonal wsher and one hexagonal or square nut, length of bolt n.exc 5cm long, dia metre of shank 5 to 10 mm confirming to IS compete all as specified
Welded steel wire fabric of wire dia min 2mm and of mesh size not exc 25mmx25mm fixed to steel members and weight n exc 4 Kg per square metre complete all as specified.
Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete all as specified.
MS ties hold fast cleats etc including necessary drilling holling for securing gates doors etc complete conforming to Fe 290 Gde 165.
Mild steel, plain, black sheet in wall cladding, steel gates and similar work, cut to size, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel framing with plain 40 mm lap joints with riveted and bolted thickness of sheet in 1.60mm all as specified.
PCC (1:4:8) type D-2 (using 40mm graded crushed stone aggregate) as in foundations filling and mass concrete complete all as specified.
Plain cement concrete 1:2:4 type B-1 using 20 mm graded stone aggregates as in bed blocks, coping, cills, plinth courses including weathering, slightly rounded or chamfered angles and throating and necessary form works, all as specified in clause 4.11.16.2(e) of MES Schedule Part-I
Mild steel framed work as in grills, grating etc. including necessary frame work for grill and similar work confirming to Fe-410-0 or Fe 310-0 complete all as specified
Extra for forming fair finish drain or channel 30CM inner grith in cement concrete using extra cement complete all as specified.
Excavation in trenches in any type of soil and getting out complete n.exc 1.5m wide and n.exc 1.5m in depth for foundation etc all as specified and directed.
Returning, filling in (soil), including spreading, leveling, watering and well ramming in layers not exc. 25cm, complete all as specifed & directed.
Removing excavated material to a distance not exc. 50m and depositing where directed at a level not exc. 1.5m above the starting point, complete all as specified & directed.
Cement concrete 1:3:6 type C-2 using 40 mm graded stone aggregates as in beds of SGSW pipe 150mm bore, laid to required slope including packing under and haunching against the sides of pipes after they are laid and tested complete all as specified.
150mm bore (internal diameter) salt glazed stone ware drain pipes grade ‘A’ laid in trenches on concrete bed to slopes, jointing and testing including fittings complete all as specified.
TMT reinforcement bars 6 to 8 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified.
Providing precast cement concrete type B-1 1:2:4 (using 20mm graded aggregate) as in cover slabs for drain system etc,(except blocks set in 1:4 cement mortar) as specified.
Plain cement concrete 1:2:4 type B-1 using 20 mm graded stone aggregate as in drains or surface channels, finish even and smooth without using extra cement complete, all as specified .
Soakage wells, excavation in ordinary soil, foundation in PCC (1:3:6) wells of Honey Combed and solid in M-25 concrete, including intercepting chamber, sreen chamber, brick work in cement mortar (1:4), RCC cover slab in M-25 /RR masonry / filing with brick bats complete of size 2.40 mtr internal dia and 4.50 mtr deep as per drawing No CE/TD-1202/2003 Sheet 1/2 & 2/2 including upto date amendments
450mm dia reinforced concrete pipes, class NP-3, laid and jointed complete with collars complete all as spd.
Taking down carefully, copper / aluminium conductor unserviceable / perished point wiring (any type) for light/ fan/ light socket or power socket etc complete with fittings such as switches, sockets, ceiling roses, pendant holders, bracket holder, light fittings, regulators etc, including making good to disturbed surfaces of wall/floor etc, complete, all as specified & directed.
Taking down main switches, distribution boards etc of any type and capacity along with the existing boards, and removing the same from site and making good the disturbed surfaces/portion of walls etc. all as directed.
Taking down old and unserviceable sub main wiring of any size and description and removable the same from site and making good the disturbed surfaces/portion of walls etc. all as directed.
M&L for concealed point wiring complete with 1.5 Sqmm single core PVC insulated and unsheathed multi stranded copper conductor cable 1100 volt grade, (FRLS) drawn through PVC conduit 20 mm dia, med grade , ISI marked and fixed in concealed surface of wall , ceiling/false ceiling including cutting/chasing as required and its accessories, terminating in MS sunken box covered with and including 3 mm thick bakelite laminated sheet top cover "Hylam" and including 1.5 Sqmm single core PVC insulated and unsheathed multi stranded copper conductor cable(FRLS) as earth continuity conductor and connected to earth dolly complete asll as specifed and directed by Engr in -charge for the following :- (a) One light/fan point controlled by one on way switch
(b) One socket outlet 05 Amps on the same board
(c) One socket outlet 05 Amps on independent board
M&L for concealed point wiring complete with 2.5 Sqmm single core PVC insulated and unsheathed multi stranded copper conductor cable 1100 volt grade, (FRLS) drawn into PVC conduit 20 mm dia, medium grade, ISI marked and fixed in concealed surface of wall,ceiling/false ceiling including cutting/chasing as required and its accessories, terminating in MS sunken box covered with and including 3 mm thick bakelite laminated sheet top cover "Hylam" and including 2.5 Sqmm single core PVC insulated and unsheathed multi stranded copper conductor cable(FRLS) as earth continuity conductor and connected to earth dolly complete asll as pecifed and directed by Engr in -charge. NOTE FOR SER NO 69 TO 72: (a) Two runs of single core cable with one run of earth continuity cable including PVC conduit and its accessories will be measured and paid as one RM. (b) Rate are inclusive cutting chases of bricks and making good to disturbed surfaces when ever required. (c) Proper colour coding should be adopted for phase, neutral and earth .
Switch socket combination, two in one, 6 pin type, 5 & 15 Amp, flush type universal, complete all as specified & directed.
Switch socket combination, two in one, 5 pin type, 5 Amp, flush type universal, complete all as specified & directed.
Socket outlet two in one, 5 pin type, 5 Amp, flush type, complete all as specified & directed.
Ceiling rose surface type, bakelite 65mmx50mm, 3 terminals, complete all as specified & directed.
Switch piano flush type 5 Amps 240 Volt, single pole one way, complete all as specified & directed.
Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings, complete all as specified & directed.
LED lamp in white colour of 10 watt, base Cap B-22, complete all as specified & directed. Make : Philips/ Crompton/ Bajaj/ Wipro/ Syska Led/ GE Lighting/ Surya/ Havells
Sheet metal enclosure, factory made for DBs, protection class IP-36, phosphatised powder coated, double door when MCB's to be used, single pole & neutral, 240 volts with 200 amps rated copper bus bar & neutral link earthing stud, 8 way, complete all as specified & directed.
MCB, single pole & neutral, 40 Amp, AC, 10 KA repturing capacity, 240 Volt, 'C' series, complete all as specified & directed.
MCB, single pole, 6 to 32 Amp, AC, 10 KA repturing capacity, 240 Volt, 'C' series, complete all as specified & directed.
Fan regulator, deluxe socket type (electronic step type) for 1200/1400 sweep AC ceiling fan, complete all as specified and directed.
Earthing of galvanized steel earth plate electrode 600mm x 600mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtr depth below normal ground level) with top edge of earth not less than 1.5 mtr below normal ground level, surrounded on all sides by 150mm thick charcoal & common salt starting from ground below earth plate upto 150mm above GI plate in alternate layers connected to and including earth lead wire 4.0mm (8SWG) by means of steel bolts, nuts, check nuts and washers, test point made of GI strip 40x8mm, 10cm long PCC 1:2:4, type B-1 in pit with precast RCC 1:2:4 type B-1 in cover reinforced with XPM not less than 4 Kg per Sqm with 15mm bore GI light grade protection pipe, 20mm bore GI medium grade watering pipe with funnel including charcoal, dust, salt, all as shown in electrical plate No 3 of SSR Part-I (2009) complete with necessary earth work in any type of soil, removal to a distance not exceeding 50 mtr, including testing on completion, complete all as specified & directed. Note : (a) The cost of earth work, PCC pit of size shown in electrical plate No.3, funnel, watering pipe, wire mesh, charcoal, dust, common salt, 20mm bore medium grade watering pipe & 15mm bore light grade GI pipe as protection to earth lead wire etc shall be deemed included in the unit rate for earthing. (b) After completion, during testing, if the earth resistance equal or less 2 ohms is not obtained, earthing will be regenerated at no extra cost till the desired earth resistance is obtained.
New generation energy saving and environmental friendly long life LED street light of 20W made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having top opening seperate driver compartment with IP65 protection and impact resistance of IK07 including GI bracket made of 32mm dia light grade GI tube 1.2 metre bend to shape with 02 nos FI clamp of 32x4mm with nuts, bots, washers, making connection with PVC copper conductor cable of appropriate size, complete all as specified & directed. Make : Havells Cat Part No. ENDURACITYLITEPLATSL20WLED757 SASY BOPC or equivalent of Philips/ Crompton/ Bajaj/ Wipro/ Syska Led/ GE Lighting/ Surya
Energy saving 10W LED bulk head luminaires, IP-65, oval shape, surface mounted with all other accessories prewired and making connections with copper flexible twisted twin cord of appropriate gauge and length,230v, 50Hz including taking down old unserviceable fitting including taking down old unserviceable fittings, complete all as specified & directed. Make. Havells, Cat Part No.RUGBYNEONFT10WLED760SSYMBOPC or equivalent in Philips/ Crompton/ Bajaj/ Wipro/ Syska Led/ GE Lighting/ Surya
Surface & wall mounted, LED tube light fitting, 20W, glare free, smooth light distribution, 230v, box type, epoxy powder coated CRCA sheet housing with reflector cover channel, aesthetic looking end cap and HPF LED driver with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable of suitable size, complete all as specified & directed. Make. Havells, Cat Part No. ENDURALINEARNEOBS20WLED865SPCWH or equivalent in Philips/ Crompton/ Bajaj/ Wipro/ Syska Led/ GE Lighting/ Surya
Taking down existing ceiling fan of any size and refixing the same after repair of building including provision of three core flexiable copper cord of size 23/0.0076 of required length from ceiling rose or connector to ceiling fan, complete all as specified & directed.
Preparation of old painted surfaces of ceiling fan by scrubbing, cleaning with sand paper/wire brush etc making good surfaces and painting by applying two coats of whitensynthetic enamelled first quality paint over a coat of red oxide zinc chrome primer using spray gun in situ including filling cavities with filler and marking Srl No SM No / MES No with black paint, complete all as specified & directed.
XLPE insulated, armoured heavy duty electric cable (heavy duty) with aluminium conductor, 1100 volts grade, cross-sectional area 6 Sqmm 2 core connected with suitable cable gland and aluminium lugs, laid in trenches or passing through pipes including testing, complete all as specified and directed. (Earth work, brick protection and sand cushioning shall be measured and paid for separately)
Galvanised iron tube 40mm bore light grade (ISI marked) for cable protection to poles/under floor/under roads/alongwith walls complete including sealing of pipe ends with approved sealing compound, complete all as specified and directed.
Sand cushioning to under ground cable, laid in trenches 8cm thick below the cable and 15cm thick above the cable after laying and stretching the cable complete punned to 18cm, complete all as specified and directed. Note:- Punned thickness of sand will be measured and paid.
Brick well burnt locally available sub class 'B' laid over sand cushioning for mechanical cable protection in trenches with width of brick perpendicular to the length of cable, complete all as specified & directed.
M/S Rajesh Kumar Contractor
ASIA ENTERPRISES
JR CONSTRSTRUCTION CO.
M/s Joginder Lal Malhotra
SHIVAM CONSTRUCTION COMPANY
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .