| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.7 CrAccepted-AOC CHANDAN NAGAR OPP IOCL PERTROL PUMP RAMPUR ROAD BAREILLY UP 243001 | BAREILLY | BAREILLY | UTTAR PRADESH | 243001 | ₹2.7 Cr Quoted ₹2.8 Cr | L1 | Accepted-AOC Being L1 and reasonable. |
| 2 | L2₹3.3 Cr+₹57.1 L (20.7%)Rejected-Finance 143 RAM GALI HAJINDER NAGAR II KANPUR UP PIN 208007 | KANPUR NAGAR | UTTAR PRADESH | 208007 | ₹3.3 Cr+₹57.1 L (20.7%) | L2 | Rejected-Finance Being other than L1 |
| 3 | L3₹3.7 Cr+₹92.9 L (33.7%)Rejected-Finance | ₹3.7 Cr+₹92.9 L (33.7%) | L3 | Rejected-Finance Being other than L1 |
| 4 | L4₹3.9 Cr+₹1.1 Cr (40.6%)Rejected-Finance | ₹3.9 Cr+₹1.1 Cr (40.6%) | L4 | Rejected-Finance Being other than L1 |
| 5 | L5₹4.0 Cr+₹1.2 Cr (44.0%)Rejected-Finance 303 GHS 888 SECTOR 20 PANCHKULA 134116 HARYANA | PANCHKULA | PANCHKULA | HARYANA | 134116 | ₹4.0 Cr+₹1.2 Cr (44.0%) | L5 | Rejected-Finance Being other than L1 |
Tender Value
₹3.3 Cr
EMD Value
₹4.1 L
Closing Date
8 Jul 2021, 6:00 pmClosed
Chief Engineer Bareilly Zone
Headquarters Chief Engineer Bareilly Zone Military Engineer Services Sarvatra Bhawan, Station Road Bareilly Cantt Bareilly - 243001
RECTIFICATION OF OUTSTANDING DEFECTS IN MAP PH-I MARRIED ACCN AT RISK AND COST OF M/S RITES AT SHAHJAHANPUR UNDER GE (EAST) BAREILLY
2021_MES_432062_2
CEBZ/BLY/T-30 of 2020-21
Open Tender
Civil Works
Item Rate
270 days
Shahjahanpur
Please refer Tender documents.
8 documents required · 8 mandatory
₹2,000
GE (East) Bareilly
₹4.1 L
Yes
15 Jul 2021
17 Jun 2021
10 Jul 2021
17 Jun 2021
8 Jul 2021
20 Jun 2021
Amount
DEMOLITION AND DISMANTLING BUILDING WORKS
Taking up or down 20 mm steel tubing and connections complete all as specified and directed.
Taking up or down 15 mm pvc tubing and connections complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete as directed and specified.
Taking down cement plaster of any description, thickness on brick, stone, concrete surfaces including racking out joints, hacking for key, scrubbing down with water, removal of rubbish and cleaning, etc complete as directed and specified.
Demolition of cement concrete (un reinforced) in ground floor and paving n. exc 15 cm thickness (below or above ground level) including removing rubbish off the premises complete all as specified and as directed.
Taking down old CI pipe of 100 mm single socketed upto a height of 10.30 meter in any length and in any position complete as directed and specified.
Dismantling boarding, any description, fixed in any position with nails complete as directed and specified.
Taking down shutters of any description area n exc 1 sqm each complete all as specified and directed.
Taking down shutters of any description but area exc 1 sqm and n exc 2 sqm each complete all as specified and directed.
BLDG WORK
S&F GI tubing of 20 mm dia, medium grade with all fittings and fixed to walls or ceiling (concealed) or laid in floors complete all as specified and directed.
S&F 16mm dia (inner dia) Polyethylene Aluminium Ployethylene (PE-AL-PE) composite pressure pipes including all EZ type internal sealing with brass fittings (such as elbows, tees, reducers, couplers, short pieces, connectors, etc.) fixed to walls/chajja/ceiling and hooks (in case of concealed pipe work)/ clamps (in case of exposed pipe work) complete all as specified and directed. Makes: Nexgen Composite Industries/ Jindal Pex Tubes Pvt Ltd/ Kitck ISI PE-AL-PE pipes Note:- 1. This work has to be done by a trained plumber with a minimum 5 years company experience certificate. 2. All samples of PE-AL-PE pipes shall be as per sample pipe kept with GE (East) Bareilly. 3. (a) Net weight of 200 mtr per carton should be 22.00 (+/-2) Kgs. (b) Water pressure test is also to be done by contractor before concealed the pipes.
S&F 16mm dia (inner dia) Polyethylene Aluminium Ployethylene (PERT-AL-PE) composite pressure pipes for (Hot water Distribution) including all EZ type internal sealing with brass fittings (such as elbows, tees, reducers, couplers, short pieces, connectors, etc.) fixed to walls/chajja/ceiling and hooks (in case of concealed pipe work)/ clamps (in case of exposed pipe work) complete all as specified and directed. Makes: Nexgen Composite Industries/ Jindal Pex Tubes Pvt Ltd/ Kitck ISI PE-AL-PE pipes Note:- 1. This work has to be done by a trained plumber with a minimum 5 years company experience certificate. 2. All samples of PERT-AL-PE pipes shall be as per sample pipe kept with GE (East) Bareilly. 3. (a) Net weight of 200 mtr per carton should be 22.00 (+/-2) Kgs. (b) Water pressure test is also to be done by contractor before concealed the pipes.
Cutting chases, pinning in. brick work and making good to facings where required and pointing in cement mortar (1:3) to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10 cm girth complete all as specified and directed.
S&F in repair 15 mm dia Pillar taps, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe complete all as specified and directed.
S & F for 32 mm bore low density polyethylene pipes (LDPE) pressure rating 6 Kg/Sqcm fixed to wall, ceiling or laid in floors complete all as specified and directed.
S&F 15 mm dia bore PVC connection 600 mm long with both ends PTMT nuts complete all as specified and directed.
S&F in repairs 15mm dia Stop valves/angle cock cast copper alloy chromium plated screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and directed.
S&F in repairs 15mm dia concealed Stop valves, cast copper alloy, chromium plated fancy type screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or brass ferrule with long shank and cup complete all as specified and directed.
S&F in repair 15 mm dia Bib taps, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed.
S & F in repair 125mm size cast copper alloy chromium plated shower rose with or without swivel joints including fixing to 15mm steel pipe or union complete all as specified and as directed.
M&L for Glazed ceramic tiles in vertical surface 300x 200x 7 mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match complete all as specified and directed.
M&L for non-skid coloured ceramic tiles not less than 7 mm thick (square/ rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed.
M&L for rendering 10mm thick on fair face of brick work/ concrete surfaces in cement mortar (1:4) for fixing of tiles on vetical surface complete all as specified and directed.
M&L for screed bed or bedding layer of mortar, 15 mm thick, in cement mortar (1:6), for laying floor finishes/ tiles complete all as specified and directed.
M & L for 12 mm thick rendering on fair other than fair faces of brick work or concrete surfaces with cement mortar (1:4) even and fair without using extra cement complete all as specified and directed.
M&L for preparation of newly plastered surfaces and applying three coats of white wash on walls complete all as specified and directed.
M&L for two coat of oil bound distemper on newly plastered wall surface over a coat of primer including preparation complete all as specified and directed .
M&L for plain cement concrete (1:5:10) type E-2 using 40mm graded crushed stone aggregate as in foundation/mass concrete complete all as specified and directed.
Material & labour for sunken slab treatment comprising of the following :- (a) Taking out/ down old existing sunken slab treatment and cleaning the old RCC surfaces of sunken slab including removal of the rubbish from the site of work to a distance n.exc. 250mm complete all as specified and directed. (b) Material & labour for applying bituminous priming coat/tack coat over PCC surfaces @ 0.30 Kg per square metre. (c) Material & labour for applying bitumen grade 85/25 over priming coat @ 1.20 Kg per Square metre. (d) Material & labour for 10mm thick plastering in cement mortar (1:4) using water proofing compound (WPC) @ 200 ml per bag of cement. on wall of sunken floor. (e) M & L for modified polymeric water proofing membrane 2.00 mm thick (weight not less than 3.00 Kg/ Sqm consisting 100mm micron HMHDE FILM). (f) Material & labour for applying bitumen grade 85/25 @ 1.20 Kg per Square metre on top of membrane with 100mm over lap at side end lap where required. (g) Supply & fix of 32mm dia GI pipe medium grade, 450m long (for draining out the water) complete all as specified and as directed.
Material & labour for 25mm thick PCC (1:2:4) type B-0 (using 12.5mm graded stone aggregate) as in base of floors complete all as specified and as directed.
S&F in repair vitreous china squatting pan of Orissa pattern long pan size 580 x 440 mm white with "P"or "S" trap size 100 mm dia front or back inlet and integral foot rest any pattern (excluding flushing cistern and flush pipe) including provn of cement concrete bedding (1:2:4), minimum 150mm all round and finish just below level of rim of pan complete all as specified and directed.
S&F in repair PVC low level flushing cistern 10 litres, valveless, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets, flushing pipe complete all as specified and directed.
S&F in repair for 100 mm dia grating doom of PTMT (Minimum weight 25gms) complete all as specified and directed .
S&F Cast iron soil, waste and vent pipes100 mm dia in any length with or without ears, with cement joints, laid in trenches or in floors complete all as specified and directed .
All as per item No 35 above but fixed to walls complete all as spd and directed.
S&F CI Bends 100 mm bore (any radius), diminishing pieces or tapers (larger bore measured) complete all as specified and directed .
S&F in repair CI oval access door 100 mm dia complete all as specified and directed .
S&F Branch pieces, 100mm bore single (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches and acess door complete all as specified and directed .
S&F Cast iron cowls 100mm bore complete all as specified and directed .
S&F Cast iron 100mm bore junction single T equal or unequal complete all as specified and directed .
S&F stack clamps made out of 50x5 mm flat iron and 16mm dia round iron stays, for 100mm bore pipes, including bolts and nuts and securing ends of stays to wall or roof complete all as specified and directed .
M&L for providing & injecting chemical for post construction ATT along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc in a portion with cement mortar (1:2) to match the existing apron complete all as specified and as directed.
M & L for post construction anti-termite treatment of soil under existing floors using emulsion @ one litre per hole, 300mm apart including drilling and plugging 12mm dia holes with cement mortar 1:2 (1 cement : 2 coarse sand) to match the existing floor soil complete all as specified and as directed.
M & L for post construction anti-termite treatment of soil at points of contact of wood work by chemical emulsion (in oil or kerosene based solution) @ 0.5 litre/hole by drilling 6mm dia holes at a downward angle of 45 degree at 150mm centre to centre and sealing the same complete all as specified and as directed.
M& L for 19mm thick particle board, medium density, flat pressed, single layer type or three layer type with BWR type adhesive, fixed with screws to timber frame work complete all as specified and directed.
S&F for 25mm thick flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specfied and directed.
S&F for 30mm thick flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specfied and directed.
S&F for second class hard wood 35mm thick Glazed and skeleton door shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.24 (a) complete all as specified and directed.
S & F 40mm width of flap continuous (piano) hinges, mild steel, bright finish or electro galvanised complete all as specfied and directed.
S&F for 75mm size of hasp and staple, safety type, brass with mild steel hinge pin including bolt to hinge plate and fixed with screws complete all as specfied and directed.
S&F 100mm size aluminium alloy handles, cast type anodised completed all as specified and directed.
S&F 300mm long mild steel sliding door bolts, plate type, stove enamelled black, with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate and fixed completed all as specified and directed.
S&F mild steel butt hinges 125mm size cold rolled medium weight complete all as specified and directed.
S&F 140mm (Overall length of cover plate) floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, in floor complete all as specified and directed.
S&F mild steel butt hinges 100mm size cold rolled medium weight complete all as specified and directed.
S&F 150 mm long mild steel pressed handles, oval type, stove enamelled black complete all as specified and directed.
S&F 300mm, ordinary rat tail rod pattern springs including roller and roller plate complete complete all as specified and directed.
S & F 200 mm long mild steel barrel tower bolts, stove enamelled black, with bright bolt complete all specified and as directed.
M&L for 12mm thick Plywood, grade BWR, type BB, fixed with screws to timber frame work complete all as specified and directed .
S & F 40mm dia, cupboard knobs fixed with nut, screw and washer of mild steel, bright finished complete all specified and as directed.
M&L for preparation of new or previously untreated wooden surfaces of any description over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed.
EXTERNAL ELECTRIC SUPPLY
Supply and Fixing erecting steel tubular poles in vertical position/as strut poles sewaged 410-SP-55, 11 Mtr long, ISI marked complete with cast iron / M S base plate, finial taper plug, bolts, nuts washers and screws as required duly painted with two coats of aluminium paint over a coat of read oxide primer above ground level, internally and including Planting depth (externally) with two coats of bituminous paint and numbering of poles, black strips etc complete all as specified and as directed.
Ditto- all as per item No 64 above but 9 meter long steel tubuler pole 410-SP-31 complete all as specified and as directed.
Supply & fixing 33 KV 400 Amp isolator with earhlink out door type, three phase, double break, centre rotating type suitable for manual operation. Each pole of isolator shall be provided with two sets of contacts to be operated in series and the moving contact blades shall rotate in horizental plane and galvanised steel frame operating pipe of 25mm bore medium grade GI pipe suitable for operation while standing on ground for 3 phase and locking arragement complete all as specified and directed.
Supply & fixing 33 KV 400 Amp isolator out door type, three phase, double break, centre rotating type suitable for manual operation. Each pole of isolator shall be provided with two sets of contacts to be operated in series and the moving contact blades shall rotate in horizental plane and galvanised steel frame operating pipe of 25mm bore medium grade GI pipe suitable for operation while standing on ground for 3 phase and locking arragement complete all as specified and directed.
Supplying, installing and testing and commissioning of a set of 3 Nos lightening arrestors station class single pole non linear register type as per IS 3070 with all fittings discharge capacity 65 KA, rating 30KV(rms) suitable for 33 KV grounded neutral link system fixed on channels, cross arms including connecting to over head line and up to earth pit complete all as specified and directed.
Supplying, installing and testing of outdoor type (CTs) 33 KV current transformer- 03 Nos oil cooled/dry Type polycrete having CT ratio 100/50/5+5 for connecting 33 KV side of Transformer bushing class 5P 15 VA burden suitable for protection, metering and differenent operation complete all as specified and directed.
Supplying, installing and testing of outdoor type (CTs) 33 KV current transformer- 03 Nos oil cooled/dry Type polycrete Type having CT ratio50/25/5+5 for connecting 33 KV side of Transformer bushing class 5P 15 VA burden suitable for protection, metering and differenent operation complete all as specified and directed.
Supplying, installing and testing and commissioning of the out door type 33 KV PT of ratio 33KV/rt3/110V/rt3 class0.5-3, burdon 50 VA, insulation level 70 KV, voltage factor 1.2 Cont and 1.9 for 30 sec, confirming to IS 2705 complete all as specified and directed.
Supply, installation, testing and commissioning of Energy Efficient transformer plinth/platform mounted, 33 KV on primary side and 11 KV on Secondary side, capacity 2000 KVA, step down, outdoor type, 50 Cycle (50 Hz), AC double wound core type copper wound oil immersed air naturally cooled (ONAN) type with external cooling tubes winding shall be made with 99.9% pure electrolytic grade copper as per IEC 60076, transformer delta connection on primary side (33KV) and star connection on secondary side (11 KV) in accordance with vector symbol DYn-11 and having taping at of +5 % to -15% in equal steps of 1.5% changed by means of ON load tap changing arrangement. The voltage regulation shall be as per IS. Transformer oil shall be as per IS 335:1993. The limit of temperature rise after continuous full load run as specified in IS 1180, shall be suitable adjusted to suit the maximum ambient temperature prevailing at site all as specified. The transformer shall be completed with following fittings and accessories:-
(a) Cable boxes on 11 KV secondary side suitable for connecting up XLPE cable up to 1x240 sqmm x 3 core cable end. (b) HV bushing with arching horn on 33 KV side. (c) Oil conservator with filling hole, cap, drain valve and oil level gauge. (d) Dehydrating breather with connecting pipe along with first fill of dehydrating agent and oil seal. (e) Explosion relief vent mounted on tank with double diaphragm and equalizer pipe connection to conservator air space (pressure release device) (f) Air release plug (g) Shutoff valve between the conservator and bucholz relay (h) Drain valve with threaded adapter. (j) Filter valve with threaded adapter (Top and bottom)
(k) Thermometer pocket. (l) Inspection cover. (m) Jacking pads, handling and lifting lugs. (n) Roller type four Nos. Wheels. (o) Rating plate and terminal marking plate. (p) Extra bushing for neutral brought out side the secondary side for neutral earthing. (q) Hand hole of sufficient size to assess the interior of the tank. (r) First filling of transformer oil.confirming to IS 335 : 1993 (s) Cover lifting eyes. (t) Double float Bucholz relay with trip and alarm contacts (u) Pressure release valve with one set of trip contact (v) Magnetic level gauge with one set of alarm contact (w) Marshalling box containing Oil temperature indicator and winding temperature indicator
(x) Earthing Pads, Monogram plate (y) 150 mm dial type thermometer for oil temperature indicator having range 0-120 degree centigrade vapour pressure type with maximum reading pointer/Max temperature indicator and resetting device with alarm/trip contact and additional contacts for switching on or the cooling fan (z) Winding temperature indicator 150 mm dia with 2 Sets of contacts alarm + trip (aa) Shut off valve between cooling tubes and tank. (ab) Platform constructed with PCC/Brick Work and finished with cement plaster in C:M 1:4 all as per manufacturer's recommendations including working space all around as per IE Rules-1958. (ac). Necessary control cables and all other required accessories to connect, Buchholz Relay, WTI, OTI and any other trip coils with indoor control Panel of 33 KV VCB .
(ad) RTCC Panel complete with all accessories. Note No1: Contractor shall arrange for factory visit for Rep of Accepting Officer to check Routine tests as Per IS: 2026 and including the following:- (i) Double voltage /Double frequency Test (ii) Full load Test (iii) Regulation Test (iv) Efficiency Test (v) Polarity Test &Other Type & Routine test as per IS Note No. 2: The cost etc for testing of transformer shall be deemed to be included in the quoted rate. Note No. 3: Maximum losses of transformer shall not exceed values as that for at least three star rating transformer specified by Bureau of Energy Efficiency Level II (BEE). I.e Maximum allowable losses at 50 % of full load shall be 0.70 % and Maximum allowable losses at full load shall be 0.98%. Note No. 4: The transformer shall be energy efficient type with core made up of high grade Cold Rolled Grain Oriented (CRGO) sheets. Scrap CRGO material shall not be used for manufacturing of transformer.
Supply, installation, testing and commissioning of out door type 33 KV VCB 800 Amp (with required structure) with 1 No. digital operation relay and control panel complete all as specified and directed with following technical specifications:- (i) No. of poles- 3 Nos. (ii) Nominal system voltage- 33 KV (iii) Highest system voltage- 36 KV (iv) Rated normal current for bus bar of circuit breaker- 800A (v) Rated normal current for interrupter- 1000A (vi) Rated short circuit breaker current (rms)- 25KA (vii) Rated short circuit current (peak)- 63KA (viii) One minute power frequency withstand voltage to earth- 70KV (ix) Rated auxiliary supply for spring charge motor, lamp and heater circuit- 230V AC. (x) Rated supply voltage for trip/close coil-110V DC
Supplying, installing, commissioning and testing HT 11 KV, 3 phase 50 Hz 250 MVA 13.1 KA for 03 Nos out going VCBs & 350 MVA 18.37 KA for 02 Nos incoming VCBs and 02 No. Bus coupler, each single panel switch board, vertical/ horizontal isolation and horizontal draw out type vacuum circuit braker (VCB) confirming to IS-13118, EIC 56 totally enclosed, single copper bus bar floor mounting metal clad indoor extendible, fully interlock vertical isolation and horizontal draw out type indoor circuit breaker suitable for installation in 11 KV 3 phase 3 wire supply system. The each VCB shall consist the following:-
FIXED PORTION (a) Floor mounting jig set fabricated steel cubical complete with supports for the gear, earthing connections, final wiring and labels. (b) Integral earthing feature built-in for bus bar and circuit earthing. (c ) Three phase epoxy resin/encapsulated isolating spout assemblies complete with isolating contacts and pair of automatic safety shutter which may be individually locked in the closed position for earthing/ maintenance purpose. (d) Three Nos , epoxy cast WPL current transformer with 100/50/5+5, 30 VA burden and CL 1 and CL 5P10 accuracy for metering & protection respectively for 06 Nos VCB outgoing.
(e) Three Nos , epoxy cast WPL current transformer with 200/100/5+5, 30 VA burden and CL 1 and CL 5P10 accuracy for metering & protection respectively for 02 Nos VCB incomimg. (f ) One No. Bus Coupler with interlocking. (g) One Nos three phase 3 limb PT 11 KV/110V with 100 VA Burden per phase class B class1.0 accuracy for metering & protection respectively for 02 Nos VCB incoming. (h) Rear cable box suitable for termination of cables. (j) Multicore cable termination block. (k) Heater with switch and thermostat. (l) Door type instrument panel extension chamber.
REMOVABLE PORTION (Breaker) (a) 400A 13.1 KA, 03Nos VCB outgoing with hand charge mechanism and electrical closing. The breaker is mounted on a truck carriage complete with self contained fully interlocked raising and lowering mechanism. The carriage is fitted with: (i) Mechanical On/OFF indicator with hand trip device (ii) Shunt Trip Coil (110VDC) (iii) Shunt release Coil(110V DC) (iv) Mechanical operation counter (v) Spring charge motor-220 VAC
(b) 630A 18.37 KA 02 Nos VCB incoming with hand charge mechanism and electrical closing. The breaker is mounted on a truck carriage complete with self contained fully interlocked raising and lowering mechanism. The carriage is fitted with: (i) Mechanical On/OFF indicator with hand trip device. (ii) Shunt Trip Coil (110VDC) (iii) Shunt release Coil(110VDC) (iv) Mechanical operation counter (v) Spring charge motor-220 VAC
(c) 630A 18.37 KA, VCB Bus Coupler 02 No. with 3 phase copper bus bar 800 Amp capacity as required at site including 11KV phase barriers with hand charge mechanism and electrical closing. The breaker is mounted on a truck carriage complete with self contained fully interlocked raising and lowering mechanism. The carriage is fitted with: (i) Mechanical On/OFF indicator with hand trip device (ii) Shunt Trip Coil (110VDC) (iii) Shunt release Coil(110VDC) (iv) Mechanical operation counter (v) Spring charge motor-220 VAC
Supply and laying, HT underground cable XLPE insulated, screened with extruded semiconducting compound in combination with copper tape cores laid up, inner PVC sheathed, galvanized steel strip armoured, overall PVC sheathed electric power cable with stranded compact aluminium conductor 33000 volts (Earthed) grade 185 sq mm 3 core confirming to IS:7098 (Part-II) with latest amendements, suitable for earthed system laid in duct/trench/along pole etc including making connection with lugs and crimping complete all as specified and ditrected. Make : Finolex/Havells/Gloster/plaza/polycab
Supply and laying, HT underground cable XLPE insulated, screened with extruded semiconducting compound in combination with copper tape cores laid up, inner PVC sheathed, galvanized steel strip armoured, overall PVC sheathed electric power cable with stranded compact aluminium conductor 11000 volts (Earthed) grade 240 sq mm 3 core confirming to IS:7098 (Part-II) with latest amendements, suitable for earthed system laid in duct/trench/along pole etc including making connection with lugs and crimping complete all as specified and ditrected.
Material and labour for XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) earthed with aluminium conductor, 11000 volts (Earthed) grade cross secional area 95 Sqmm 3 core. suitable for earthed system laid in duct/trench/along pole etc including making connection with lugs and crimping complete all as specified and ditrected.
Supply and fix cable jointing kit for 33 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Al conductor cable of size 120 to 185 sq mm complete all as specified and ditrected.
Supply and fix cable jointing kit for 11 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Al conductor cable of size 50 to 95 sq mm complete all as specified and ditrected.
Supply and fix cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Al conductor cable of size 50 to 95 sq mm complete all as specified and ditrected.
Supply and fix cable jointing kit for 11 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Al conductor cable of size 240 sq mmto 300 sqmm complete all as specified and ditrected.
Supply and fix cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Al conductor cable of size 240 sq mmto 300 sqmm complete all as specified and ditrected.
M&L for earthing complete with galvanised steel earth plate electrode 600x600x6 mm thick burried directly in ground (earth pit not less than 2.25 mtrs deep below ground level) with top edge of the plate not less than 1.5 meters below normal ground level connected to galvanized iron earth strip 32X6mm by means of bolts nuts check-nuts and washers of galvanized iron or steel as shown in electrical plate No 5 of MES schedule Part-I connecting to earthing test point and testing on completion with including 40 mm bore light grade GI protection pipe, RCC (1:2:4) type B1 20mm thick cover reinforced with 6mm thick dia MS bars 3 Nos both ways with lifting hook made out of 6mm dia MS bar, watering arrangement with funnel and wire mesh and 20mm bore light grade GI watering pipe, earthing lead from earth plate to eqipment to point (up to 7.5M long) common salt and charcoal filling, necessary excavation and earth work complete all as specified and directed.
M&L for earthing complete with galvanised steel earth plate electrode 600x600x6 mm thick burried directly in ground (earth pit not less than 2.25 mtrs deep below ground level) with top edge of the plate not less than 1.5 meters below normal ground level connected to galvanized iron wire 4mm dia by means of bolts nuts check-nuts and washers of galvanized iron or steel as shown in electrical plate No 5 of MES schedule Part-I connecting to earthing test point and testing on completion with including 15 mm bore light grade GI protection pipe, RCC 1:2:4 type B1 20mm thick cover reinforced with 6mm thick dia MS bars 3 Nos both ways with lifting hook made out of 6mm dia MS bar, watering arrangement with funnel and wire mesh and 20mm bore light grade GI watering pipe, earthing lead from earth plate to eqipment to point (up to 7.5M long) common salt and charcoal filling, necessary excavation and earth work complete all as specified and directed.
M&L for earthing complete with copper earth plate electrode 600x600x3.15 mm thick burried directly in ground (earth pit not less than 2.25 mtrs deep below ground level) with top edge of the plate not less than 1.5 meters below normal ground level connected to copper earth strip 20X3mm by means of bolts nuts check-nuts and washers of galvanized iron or steel as shown in electrical plate No 5 of MES schedule Part-I connecting to earthing test point and testing on completion with including 40mm bore light grade GI protection pipe, RCC (1:2:4) type B1 40mm thick cover reinforced with 6mm thick dia MS bars 3 Nos both ways with lifting hook made out of 6mm dia MS bar, watering arrangement with funnel and wire mesh and 20mm bore light grade GI watering pipe, earthing lead from earth plate to eqipment to point (up to 7.5M long) common salt and charcoal filling, necessary excavation and earth work complete all as specified and directed.
Supply, installation, testing and commissioning of copper wound OFF load Tap Changer distribution transformer of capacity 63 KVA IS 1180(part I) level II suitable for HV input voltage (+) 7.5% and (-) 7.5% in 07 steps of 33 KV band width with HV output voltage 0.433 KV outdoor type oil immersed naturally cooled on load (ONAN) including cable box at output side, silica gel breather, temperature gauge, with following technical specifications of distribution Transformer and complete all as specified and directed. (i) Input- Bare bushing as per IS 3347 suitable for 33 KV rating (ii) Output- Bare bushing as per IS 3347 suitable for 0.433 KV rating (iii) Tempreature rise- 50 degree centigrade rise of top oil over an ambient of 50 degree centigrade. (iv) Tank & oil- shall be housed inside the sheet steel tank. Tanks will depend on design perimeter. Item shall be supplied with first filling of oil confirming to IS 335: 1993
FITTING & ACCESSORIES Accessories for its successful operation shall be as under as per the requirement:- (i) Rating plate,, Plain oil level gauge and conservator. (ii) Drain valve, filter valve, sampling valve with plug & earthing terminals. (iii) Inspection cover, thermometer pocket & lifting lugs. (iv) Silica gel breather . (v) Pressed steel radiators with shut off valve.
Design,supply, installation, commissioning, testing of LT Panel board CPRI approved cubical outdoor type 3 phase 4 wire outdoor type, weather proof made out of 3.15 mm thick MS sheet and MS angle iron 50x50x6mm base frame of suitable size as required at site for fixing panel board including necessary fixing arrangement. painting of panel board internally and externally complete with spray painting with two coats of powder coated synthetic enamel paint over a coat of red oxide primer. Panel shall be totally enclosed dust and vermin proof both side opening with locking arrangement, suitable for Ac 415V, 3 phase, 50HZ system, Red, yellow, Blue and black colour insulated, fixed in the PCC 1:2:4 not less than 500mm above the ground level, connection of all incoming cables / out going cable with the thimbles / lugs / cable glands etc., opening at both side i.e. front / back, locking arrangements, tinned Copper bus bar 50X12mm size, bulb holder light point controlled with 5 Amp switch connected at the entry point of incoming supply, all the accesories pre connected with suitable size Aluminium bus bar / single core copper conductor comprising of the following all as specified & directed.
(a) Bus bar with 04 Nos copper strip with heat shrinkable insulator sleeve suitable for 200 Amps and 100 Amps for neutral. (b) Indicating lamp LED type for all the 3 phase with different colour lamp red, yellow and green. (c) Multi functional electronic meter showing voltage,Amps, frequence and power factor along with suitable CTs - 04 Nos . INCOMING:(i) MCCB four pole with thermal magnatic release settig 415 volt 25 KA breaking capacity 100 Amps 01 No. OUTGOING:(i) MCCB four pole with thermal magnetic setting release AC 415 volts 50 Hz 16 KA 32 Amps- 02 No. (ii) 01 No MCCB four pole with thermal magnetic setting release AC 415 volts 50 Hz 16 KA 25 Amps- 01 No. (iii) Wiring of Panel with suitable size of copper cable. (iv) Cable glands to adjust incoming and outgoing cable including necessary connections.
(ii) Battery charger with trickle and boost charging facility rated 230 V with MICROPROCESSOR BAISED CONTROL circuit system with necessary protection digital display and indicating lamps - 01 No (iii) Lead acid station type battery bank with each battery rated 2V battery of 55 Nos giving supply to 2 circuit each 110 volt, 110 AH battery supply on metal racks appropriate to accomodate all the batteries safely as directed by Engineer-in-Charge made of 50 x 5mm MS flat with rubber insulation of suitable size (not less than 2mm thick) in the battery room complete with digital type DC voltmeter, ammeter and over current protection - 01 No
(iv) DC control panel comprising of MCBs distribution board with MCB 2 pole 40 amps - 4 Nos mounted on MS sheet enclosure panel board grouted on floor including necessary connection, with copper conductor cable all as directed and specified. (v) One box/Cabinet, suitable to house 55 Nos, 2 Volts 110 AH tubular batteries made out of 2.0 mm thick MS sheet duly painted with two coats of acid resistant paint inside & outside covering total surface area with suitable locking arrangement. Make ; Exide, Amaron, Luminous
M & L Lightning arresters expulsion type complete with all fittings, transmission class, discharge capacity 65 kilo amp 11000 Volts complete all as specified and directed.
M&L for Cross arms, bracings, supports, clamps & back plates fabricated from structural steel sections for with ISMB / Channel /angle iron/flat including nuts, bolts, washers welding, bending, cold or hot drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of aluminium paint complete all as specified and directed.
S&F Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for HT, 25x20cm complete all as specified and directed.
Supply and fix Disc type insulator, porcelain, vitreous suitable for 33 KV socket type white brown or green single disc assembly for tension with tension clamps for working pressure 33000 Volts complete all as specified and directed.
Supply and fix Pin type insulator, porcelain, vitreous suitable for 33 KV socket type white brown or green single disc assembly for tension with tension clamps for working pressure 33000 Volts complete all as specified and directed.
Supply and fix Post type insulator, porcelain, vitreous suitable for 33 KV socket type white brown or green single disc assembly for tension with tension clamps for working pressure 33000 Volt complete all as specified and directed.
S&F ACSR conductor for HT33 KV over head line Aluminium conductor size DOG including complete all as specified and as directed.
Supply & fixing of G.I Strip of size 32 x 6 mm as in earthing with all hardwares required complete to electrical equipment situated at different locations complete all as specified and as directed.
Supply and fix air break GOD tripple pole, mecahanically operated, mounted on insulator and galvanised steel frame, with operating rod of 25 mm bore medium grade GI pipe mechanism worked from ground level, for current rating upto 200 Amps 11000 volt complete all as specified and as directed.
M&L for replacement of XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 50 sqmm 3.5 core complete all as specified and directed.
M&L for replacement of XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 25 sqmm 4 core complete all as specified and directed.
M&L for replacement XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 16 sqmm 4 core complete all as specified and directed.
Excavation in trenches n. exc 1.5 mtr wide and not exc 1.5 mtr in depth for laying under ground LT XLPE cable and getting soft/loose soil complete all as specified and directed .
Returning , filling in including spreading, levelling, watering and well ramming in laying not exceeding 25 cm thick in soft/loose soil complete all as specified and directed .
Removing excavated material (soils) to a distance not exceeding 50 m and depositing whare directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed.
Material and labour for river fine sand, washed and screened dry for caushioning to under ground cable in trenches below and around under ground cable including spreading and levelling in layers n exc 25 cm thick, well ramming including watring as required sand filling under floors or in foundation including watering and consolidation complete all as specified and directed.
M&L for laying bricks, sub class'B' for protection of cable, in trenches, laid in dry flat across the cable with length of whole bricks complete all as specified and directed.
Supplying and laying reinforced precast concrete cable cover, class EHV, type 1with peak, size 450mm x 230mm x 50mm complete all as spd and directed.
S & F steel tubing GI light grade 100mm bore for fixing of tapping of incoming and outgoing point complete all as specified and directed.
S & F steel tubing GI light grade 150mm bore for fixing of tapping of incoming and outgoing point complete all as specified and directed.
Supply and laying synthetic insulating mat 19mm thick of size (1 Mtr x 2 Mtr) ISI Marked complete all as specified and directed.
Supply and fixing LED flood light fitting 120 watts fixed on pole or wall including suitable size of mounting bracket of the fitting with FI clamp, nut, bolt and washers of suitable size including making connection with suitable wire complete all as specified and directed. Make - Havells Cat Part No. JETAIRSFLS120WLED757APWBLTG / Surya Roshni Cat Part No. SLE FL 120W IP65 LUMOS/ C&S Cat Part No. LTEF120WHPLED
S&F PG clamps/flat pad connectors/sub stn.connectors made of aluminium alloy for making connection on 33 KV bus bar (OH Lines), CTs , PTs , VCBs etc complete as per site requirement complete all as specified and directed.
Supply and fixing fire retardant/ extinguishing Electric Insulated Synthetic mat" INSULATICA 2000" of 2 mm thick ± 10% conforming to BIS : DOC.NO ETD-02(5229) P DT D30/06/03, meeting requirements of IS:3043,IS:5216 (Part-1,2&3), IS-8437 and IEC 479 Pub-1, 61111 & 61112, Tested for break down strength,Tensile/ Elongation, Ageing properties, Insulations Resistance, effects of Acid-Alkaline, Diesel and Transformer oil, Leakage Current Test, FireTest etc having Min, width of 1000mm ± 20mm.All alllied material such as Pu-Resin, Chemi Bound (Hardner), Spl PVC Adhesive, Liquid Primer etc. in what so ever quantity required to complete the job as per site requirement, suitable for 11000 Volts complete all as specified and directed.
Supply of Telestone type fiber glass discharge rod made up of high quality epoxy resin with super smooth glossy finish fiberglass tube wiitch prevents moisture and it should have excellent dielectric strength it should also include rubber insulation to increase creepage distance complete all as specified and directed.
Supply, installation, testing and commissioning of armoured XLPE Control Cables from 33 kV HT Switch gear, AC Auxiliary panels, Relay control panel, CTs, PTs, and transformer room for buchholz connection, Temp alarm & trip OLTC surge relay, differential / REF protection on cable tray, or clamped to wall / ceiling above complete all as specified and directed as under:
(a) 7c x 2.5 sq.mm Cu.
(b) 5c x 2.5 sq.mm Cu.
(c) 4c x 2.5 sq.mm Cu.
(d) 3c x 2.5 sq.mm Cu.
(e)4c x 6 sq.mm Cu.
(f) 3c x 4 sq.mm Cu.
Termination of above cables mentioned in items 115.01 to 115.06 using single compression type brass cable gland and dowels make lugs and making proper connection is in the scope of work complete all as specified and directed as under:
(a) 7c x 2.5 sq.mm Cu.
(b) 5c x 2.5 sq.mm Cu.
(c) 4c x 2.5 sq.mm Cu.
(d) 3c x 2.5 sq.mm Cu.
(e) 4c x 6 sq.mm Cu.
(f) 3c x 4 sq.mm Cu.
S & F High density poly-ethylene pipes 50 mm dia (HDPE) of pressure rating 6 kgf/cm2 laid in trenches for control cables complete all as specified and directed.
S & F High density poly-ethylene pipes 40 mm dia (HDPE) of pressure rating 6 kgf/cm2 laid in trenches for control cables complete all as specified and as directed .
S & F High density poly-ethylene pipes 25 mm dia (HDPE) of pressure rating 6 kgf/cm2 laid in trenches for control cables complete all as specified and as directed.
Supply and fixing Glow sign board at 33 KV Sub station of 4.2 mtr x 1mtr size including letter writing 33 KV MRS Shahjahanpur Cantt AGE B/R Shahjahanpur GE (East) Bareilly, electric supply and fixing accessories and Description with polycarbonate sheet suitable size including LED tube light fittings complete all as specified and directed.
Supply Electric rubber Hand gloves 33 kV ISI mark complete all as specified and as directed.
S&F junction box metal enclosure 300mm x200mm and 2 mm thickness sutable bus bar for connecting cables for security lights including 6 Amp MCB Single pole complete all as specified and directed.
Supply ,Installstion of Fire fighting items of fire extinguisher 4.5 Kg CO2 with mounting bracket supported on steel channel first filling etc 4 Nos , Bucket G iron 16 ltr (Set of 5 Nos)duly painted with 2 coats of red oxide and 2 coat of post office red enamel paint 02 Nos ,fire beater 2 Nos, fire hook 2 nos etc complete all as specified and directed.
Supply ,Erection of Busbar gantry including fixing of disc insulator for 33 KV supply and fabricatipn of gantry structures complete all as specified and directed. Note :-1) Disc insulators are included in the quoted rates. 2) MS steel will be measured separately . 3) Conductor will be measured separately.
Dismantling steel tubular poles / struts of any size and any type, complete all as specified and as directed.
Dismantling cross arms of MS channel or angle sections etc complete all as specified and as directed.
Dismantling of insulator of any type and size from existing poles after opening nuts, bolts and removing from site complete all as specified and as directed.
Dismantling of ACSR or ACC conductorscomplete all as specified and as directed.
Dismantling air break gang operated switvhes verticle / horizontal mounted including insulators and operating mechanism for insulators and operating mechanism for repair /rplacement of break/worn out components and insulators etc or carrong to MES store (spare/componets fir replacement by department). complete all as specified and as directed.
Dismantling lightening arresters of any size and any type complete all as specified and as directed.
Taking down faulty damaged unserviceable UG under ground cable of any size complete all as specified and directed.
Taking down of GI tubing upto 40mm dia any type complete all as specified and directed.
Dismantling old unserviceable Earthing complete all as specified and directed.
Taking down faulty/ damaged unserviceable transformer of capacity 2 MVA 33/11KV .Make : Schneider, Sl No (1) 624000263 (2) 624000263 complete all as specified and directed.
Dismantling of existing VCB,Bus coupler of 11 KV indoor type etc complete all as specified & directed.
Dismantling of existing control breaker of 33 KV indoor type etc complete all as specified and directed.
Dismantling of existing transformer protection relays of 33/11 KV indoor type etc complete all as specified and directed.
Dismantling of battery bank and connecting accessories complete all as specified and as direcetd.
Note;- Item Sl No 124 to 137 will be removed and kept aside , shifted to other location as directed by Engineer-in-charge.
Supply and placing of First -aid box as per specification including required medicines complete all as specified and directed.
M&L for brick work with sub class 'B' bricks lstraight or curved on plan to any radius built in cement and sand mortar (1:6) complete all as specified and directed.
M&L for providing cement concrete type B-1 (1:2:4) (20 mm graded stone aggregate) as in copings complete all as specified and directed.
M&L for rendering 15mm thick in CM (1:4) on fair faces of brick work or concrete surfaces and finished even and smooth without using extra cement complete all as specified and as directed.
M&L for preparation of new plastered surfaces of wall and applying two coats of cement based paint complete all as specified and as directed.
S & F Mild steel work as in chowkats/frame of door or gates of angle or other section with gusset plate , rail braces etc complete drilled for fixing of steel sheeting or other covering , doors etc to be prepared for hanging or sliding with and inclu either hooks and hinges or steel hanging door fittings ( exclusive of steel , sheeting or other covering , running rails and guisides ) and hanging also fastening and fixing complete all as specified and directed.
M&L for single filling in floors or pavings, laid in layers n exc 15 cm thick, spread, levelled , and blinded with earth and rammed including watering etc complete complete all as specified and directed.
Excavation in post holes (or similar holes) each n exc 0.5 cum, getting out , returning , filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm , watering and removing surplus soil to a distance n exc 50m and making good sufrace in soft/loose soil complete all as specified and directed.
M&L for plain cement concrete (1:4:8) type D-2 using 40mm graded crushed stone aggregate as in foundation/mass concrete complete all as specified and as directed.
S&F post and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire etc , flat iron fillets (for securing wire mesh etc) including all necessary drilling , bolting and riveting etc and similar work conforming to Fe 4410-O or Fe 130-O. complete all as specified and as directed.
S&F mild steel screw bolts (machine made) with hexagonal or square head at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, exc 30 cm long and dia meter of neck in mm n exc. 12mm complete all as specified and directed.
Supply and Fixing chain link fencing including line wires, any mesh size and type of any type of standards , rails , straining bolts etc including provision of binding wire. Weight 3 to 4 Kg per Sqm complete all as specified and directed.
S&F Galvanised 2 strand , steel barbed wire 2.24 mm dia barbed with 2mm dia barbs at 75 mm spacing and straining and fixing to any type of standard rail straining bolts including securing or tying at crossings with and provisons of galvanised mild steel wire, staples or steel pins etc as directed (each line wire to be measured). complete all as specified & directed.
M&L for 10mm dia and over mild steel TMT bars, cut to length , bent to shape required including cranking, bending spirally for hooping for columns , hooking ends and binding with and including mild steel wire (annealed) not less than 0.90mm dia or securing with clips , quality of steel conforming to demormed or twisted bars Fe-410-W (Gde E-250) complete all as specified and directed.
M&L for preparation of new steel surfaces of any description not otherwise described over 10 cm width or girth and applying two coats of synthetic enamelled paints over one coat of red oxide primer complete all as specified and directed.
Surface excavation n exc 30 cm and averaging 15 cm and getting out in soft/loose soil complete all as specified and directed.
M&L for cement concrete type C-2 , (1:3:6) (40 mm graded stone aggregate) 75 mm thick as in sub base of floorcomplete all as specified and directed .
M&L for machine pressed precast concrete interlocking paver block polished (coloured) any shape and any size confirming to IS 15658-2006 of 60mm thick , M-40 grade with grey cement and no pigment over sand cushion cushion layer complete all as specified and directed.
M&L for providing cement concrete type B-1 (1:2:4) (20 mm graded stone aggregate) as in edges , rounded or chamferred , copings etc complete all as specified and directed.
Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends etc complete all as specified and directed .
M&L for providing precast cement concrete type B-1 (1:2:4) (20 mm graded stone aggregate) set in CM (1:4) as in cover slabs etc complete all as specified and directed .
M&L for TMT bars 6mm to 8mm dia cut to length , bent to shape required including cranking, bending spirally for hooping for columns hooking ends and binding with MS wire (annealed) not less than 0.9mm dia quality conforming to all complete all as specified and directed .
Testing and calibaration of 33/11 KV switch yard through primary injection method for testing of trip circuit, alarm of circuit breakers at 20%, 30%, 40%, 50%, 75%, 90%, 100%, 110% and proper setting of over current and earth fault relay according to load and timing lesser than MVVNL circuit breaker of proposed 33 KV main breaker and time setting of transformer breaker should be lesser than main breaker of 33 KV and over current and earth fault settings should be according to load/ transformer current rating for proper and smooth operation including testing and calibration of OTI, WTI and bucholz relay tripping and alarm circuit for transformer protection. Note : 1. All the testing should be performed in the presence of GE/ AGE E/M GE (East) Bareilly. 2. All the testing should be performed by recognized / Govt auth / State Electricity board for testing of 33/11 KV circuit breaker.
M & L Reinforced concrete pipes, class NP2, laid and jointed complete with collars of size 600 mm for earth protection complete all as specified and directed .
Note : Tenderers may note that amount of credit Rs 1,50,827.00 will be deducted from the total amount arrived, at the time of Acceptance of contract.
M.S CONSTRUCTIONS
M/s M.S. Electric Co.
LUMOS INFRA PVT LTD
R D Bansal
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .