| 1 | L1₹44.9 LAccepted-AOC INDEX NO D 1478 CE SC PUNE PLOT NO 44 11 KACHNAYAKANHALLI VILLAGE JIGANI HOBLI ANEKAL TALUK BANGALORE PIN 560 106 KARNATAKA STATE | 560106 | ₹44.9 L Quoted ₹45.7 L | L1 | Accepted-AOC Lowest bidder |
| 2 | L2₹49.9 LRejected-Finance KOTHAR MAJALI SADASHIVGAD KARWAR UTTARA KANNADA 581360 | KARWAR | UTTARA KANNADA | KARNATAKA | 581360 | ₹49.9 L | L2 | Rejected-Finance L2 |
| 3 | L3₹51.9 LRejected-Finance | ₹51.9 L | L3 | Rejected-Finance L3 |
| 4 | L4₹53.7 LRejected-Finance | ₹53.7 L | L4 | Rejected-Finance L4 |
| 5 | L5₹53.9 LRejected-Finance LEKSHMI NIVAS TELANG ROAD NANDANGADDA KARWAR 581 304 | KARWAR | UTTARA KANNADA | KARNATAKA | 581304 | ₹53.9 L | L5 | Rejected-Finance L5 |
| Sl No | Description | Qty | Unit | MAKARAND MARINE SERVICES L7 | SIRI SALES AND SERVICES L4 | LEKSHMI ENGINEERS L5 | PEGASOS ENGINEER TRADERS L2 | ANKIT SHIP REPAIRERS AND SUPPLIERS L6 | HARSHITA MARINE SERVICES L8 | BRO TECH ELECTRICAL & ENGINEERING SOLUTION L1 | SRI GURUPRASAD INFRATECH L3 |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Rectifying the defects in domestic fluroscent tube/LED light fittings any type and at any height, ceiling rose, electric bell by tightening loose connections and rectifying defects, testing complete all as specified and directed.
Note :- The unit rate quoted shall be deemed to be included the elements of labour only for rectifying and making the fitting and fixtures functional. If replacement of parts/items is required to make the fittings functional, the cost for labour and material for the same will be measured and paid for as "S&F in repairs" under relevant items of this schedule hereinafter and in such cases the above item will not be measured and paid for. | 300 | Each | 98 ₹29,400 | 30 ₹9,000 | 50 ₹15,000 | 30 ₹9,000 | 30 ₹9,000 | 70 ₹21,000 | 30 ₹9,000 | 50 ₹15,000 |
| 2.00 | Opening switch mounting plate at normal height upto 1.5 meter, rectifying the defects in fittings and fixtures such as switches, bell push, fan regulator, sockets etc by tightening loose connections, refixing switch plate and testing complete all as directed.
Note :- The unit rate quoted shall be deemed to be included the elements of labour only for rectifying and making the fitting and fixtures functional. If replacement of parts/items is required to make the fittings functional, the cost for labour and material for the same will be measured and paid for as "S&F in repairs" under relevant items of this schedule hereinafter and in such cases the above item will not be measured and paid for. | 300 | Each | 98 ₹29,400 | 30 ₹9,000 | 50 ₹15,000 | 30 ₹9,000 | 80 ₹24,000 | 70 ₹21,000 | 60 ₹18,000 | 57 ₹17,100 |
| 3.00 | Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. complete all as specified and as directed | 833 | per point | 140 ₹1.2 L | 30 ₹24,990 | 51 ₹42,483 | 30 ₹24,990 | 25 ₹20,825 | 110 ₹91,630 | 30 ₹24,990 | 85 ₹70,805 |
| 4.00 | M&L for surface point wiring 1100 Volts grade 1.5 Sqmm PVC insulated FRLS unsheathed cable with multistranded copper conductor conforming to IS:694:1990 with ISI marking in and including PVC casing & caping medium grade with all accessories in wall/ceiling /floor/roof etc, sunk pressed steel or cast iron terminal boxes with 3mm thick plastic laminated sheet top cover including 1.5 Sqmm PVC insulated FRLS unsheathed 1100 Volts multistranded copper conductor conforming to IS:694:1990 with ISI marking as continuous earth wire connected to common earth dolly all as specified and directed for the following:-
(a) One light/fan point controlled by one switch | 80 | per point | 700 ₹56,000 | 699 ₹55,920 | 820 ₹65,600 | 700 ₹56,000 | 550 ₹44,000 | 695 ₹55,600 | 620 ₹49,600 | 700 ₹56,000 |
| 5.00 | (b) One 3 pin socket outlet 5 Amp on same board with other switches. | 40 | per point | 160 ₹6,400 | 200 ₹8,000 | 190 ₹7,600 | 250 ₹10,000 | 100 ₹4,000 | 158 ₹6,320 | 120 ₹4,800 | 150 ₹6,000 |
| 6.00 | (c) One 3 pin socket outlet 5 Amp on independent board. | 200 | per point | 720 ₹1.4 L | 699 ₹1.4 L | 820 ₹1.6 L | 700 ₹1.4 L | 500 ₹1 L | 695 ₹1.4 L | 480 ₹96,000 | 680 ₹1.4 L |
| 7.00 | (d) One bell point controlled by one push button on the same board with other switches or independent with cables of 1.5 Sqmm size. | 25 | per point | 720 ₹18,000 | 599 ₹14,975 | 820 ₹20,500 | 600 ₹15,000 | 600 ₹15,000 | 695 ₹17,375 | 700 ₹17,500 | 500 ₹12,500 |
| 8.00 | M&L for point wiring with 2.5 Sqmm PVC (FRLS) insulated unsheathed multi stranded copper conductor cable 1100 volts grade single core conforming to IS-694-1990 and including one run of continous earth wire to common earth and connected to earth with 2.5 Sqmm PVC (FRLS) insulated unsheathed multi stranded copper conductor cable draw in PVC casing caping including CI/MS/ PVC sunk boxes for mounting of 3 pin modular switch socket outlet 15/20 Amp on independent board with frame plate sheet cover of adequate size and making good disturbed surfaces with CM (1:4) to match with the existing surface complete all as specified and directed by Engr-in-Charge | 200 | per point | 980 ₹2.0 L | 1,000 ₹2 L | 1,195 ₹2.4 L | 750 ₹1.5 L | 600 ₹1.2 L | 1,310 ₹2.6 L | 700 ₹1.4 L | 850 ₹1.7 L |
| 9.00 | M&L for point wiring with 4 Sqmm PVC (FRLS) insulated unsheathed multi stranded copper conductor cable 1100 volts grade single core conforming to IS-694-1990 and including one run of continous earth wire to common earth and connected to earth with 4 Sqmm PVC (FRLS) insulated unsheathed multi stranded copper conductor cable draw in PVC casing caping including CI/MS/ PVC sunk boxes for mounting of 3 pin socket outlet 15 Amp on independent board with frame plate sheet cover of adequate size and making good disturbed surfaces with CM (1:4) to match with the existing surface complete all as specified and directed by Engr-in-Charge | 80 | per point | 1,200 ₹96,000 | 1,100 ₹88,000 | 1,100 ₹88,000 | 900 ₹72,000 | 750 ₹60,000 | 1,660 ₹1.3 L | 680 ₹54,400 | 1,000 ₹80,000 |
| 10.00 | M&L for point wiring with 1.5 Sqmm PVC (FRLS) insulated unsheathed multi stranded copper conductor cable 1100 volts grade single core conforming to IS-694-1990 and including one run of continous earth wire to common earth and connected to earth with 1.5 Sqmm PVC (FRLS) insulated unsheathed multi stranded copper conductor cable draw in existing conduit complete all as specified and directed by Engr-in-Charge for the following
(a) One light/fan point controlled by one switch | 40 | per point | 760 ₹30,400 | 599 ₹23,960 | 600 ₹24,000 | 600 ₹24,000 | 550 ₹22,000 | 726 ₹29,040 | 600 ₹24,000 | 650 ₹26,000 |
Tender Value
₹70 L
EMD Value
₹1.3 L
Closing Date
2 Dec 2025, 6:00 pmClosed
COL SAIKAT DE CWE NAVY VASCO
CWE (Navy) Vasco-Da-Gama
REPAIR AND MAINTENANCE OF INTERNAL ELECTRIFICATION FITTINGS FIXTURES INCLUDING EARTHING AND GARDEN LIGHTS AT BAITHKOL KAMATH BAY LITTLE BINAGA NOM SBS KB NEW TOWERS NEW MAP QTRS LITTLE BINAGA AT NAVAL BASE KARWAR UNDER GE SB KARWAR
2025_MES_738328_1
86017/E8
Open Tender
Electrical and Maintenance Works
180 days
CWE NAVY VASCO
Please refer Tender documents.
9 documents required · 9 mandatory
₹1,000
GE (SB) KARWAR
₹1.3 L
Yes
2 Jan 2026
4 Nov 2025
4 Dec 2025
4 Nov 2025
2 Dec 2025
25 Nov 2025
Amount
Rectifying the defects in domestic fluroscent tube/LED light fittings any type and at any height, ceiling rose, electric bell by tightening loose connections and rectifying defects, testing complete all as specified and directed. Note :- The unit rate quoted shall be deemed to be included the elements of labour only for rectifying and making the fitting and fixtures functional. If replacement of parts/items is required to make the fittings functional, the cost for labour and material for the same will be measured and paid for as "S&F in repairs" under relevant items of this schedule hereinafter and in such cases the above item will not be measured and paid for.
Opening switch mounting plate at normal height upto 1.5 meter, rectifying the defects in fittings and fixtures such as switches, bell push, fan regulator, sockets etc by tightening loose connections, refixing switch plate and testing complete all as directed. Note :- The unit rate quoted shall be deemed to be included the elements of labour only for rectifying and making the fitting and fixtures functional. If replacement of parts/items is required to make the fittings functional, the cost for labour and material for the same will be measured and paid for as "S&F in repairs" under relevant items of this schedule hereinafter and in such cases the above item will not be measured and paid for.
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. complete all as specified and as directed
M&L for surface point wiring 1100 Volts grade 1.5 Sqmm PVC insulated FRLS unsheathed cable with multistranded copper conductor conforming to IS:694:1990 with ISI marking in and including PVC casing & caping medium grade with all accessories in wall/ceiling /floor/roof etc, sunk pressed steel or cast iron terminal boxes with 3mm thick plastic laminated sheet top cover including 1.5 Sqmm PVC insulated FRLS unsheathed 1100 Volts multistranded copper conductor conforming to IS:694:1990 with ISI marking as continuous earth wire connected to common earth dolly all as specified and directed for the following:- (a) One light/fan point controlled by one switch
(b) One 3 pin socket outlet 5 Amp on same board with other switches.
(c) One 3 pin socket outlet 5 Amp on independent board.
(d) One bell point controlled by one push button on the same board with other switches or independent with cables of 1.5 Sqmm size.
M&L for point wiring with 2.5 Sqmm PVC (FRLS) insulated unsheathed multi stranded copper conductor cable 1100 volts grade single core conforming to IS-694-1990 and including one run of continous earth wire to common earth and connected to earth with 2.5 Sqmm PVC (FRLS) insulated unsheathed multi stranded copper conductor cable draw in PVC casing caping including CI/MS/ PVC sunk boxes for mounting of 3 pin modular switch socket outlet 15/20 Amp on independent board with frame plate sheet cover of adequate size and making good disturbed surfaces with CM (1:4) to match with the existing surface complete all as specified and directed by Engr-in-Charge
M&L for point wiring with 4 Sqmm PVC (FRLS) insulated unsheathed multi stranded copper conductor cable 1100 volts grade single core conforming to IS-694-1990 and including one run of continous earth wire to common earth and connected to earth with 4 Sqmm PVC (FRLS) insulated unsheathed multi stranded copper conductor cable draw in PVC casing caping including CI/MS/ PVC sunk boxes for mounting of 3 pin socket outlet 15 Amp on independent board with frame plate sheet cover of adequate size and making good disturbed surfaces with CM (1:4) to match with the existing surface complete all as specified and directed by Engr-in-Charge
M&L for point wiring with 1.5 Sqmm PVC (FRLS) insulated unsheathed multi stranded copper conductor cable 1100 volts grade single core conforming to IS-694-1990 and including one run of continous earth wire to common earth and connected to earth with 1.5 Sqmm PVC (FRLS) insulated unsheathed multi stranded copper conductor cable draw in existing conduit complete all as specified and directed by Engr-in-Charge for the following (a) One light/fan point controlled by one switch
(b) One 3 pin socket outlet 5 Amp on same board with other switches.
(c) One 3 pin socket outlet 5 Amp on independent board.
(d) One bell point controlled by one push button on the same board with other switches or independent with cables of 1.5 Sqmm size.
M&L for point wiring with 2.5 Sqmm PVC (FRLS) insulated unsheathed multi stranded copper conductor cable 1100 volts grade single core conforming to IS-694-1990 and including one run of continous earth wire to common earth and connected to earth with 2.5 Sqmm PVC (FRLS) insulated unsheathed multi stranded copper conductor cable draw in existing conduit complete all as specified and directed by Engr-in-Charge for one 3 pin socket outlet 15 Amps on independent board
M&L for point wiring with 4 Sqmm PVC (FRLS) insulated unsheathed multi stranded copper conductor cable 1100 volts grade single core conforming to IS-694-1990 and including one run of continous earth wire to common earth and connected to earth with 4 Sqmm PVC (FRLS) insulated unsheathed multi stranded copper conductor cable draw in existing conduit complete all as specified and directed by Engr-in-Charge for one 3 pin socket outlet 15 Amps on independent board
Taking down submain wiring cable of any size/ type alongwith earth wire with or without concealed/ surface conduit/ casing caping complete all as specified and directed.
M&L sub main wiring with proper colour coding, FRLS PVC insulated copper conductor, unsheated, multi-stranded, copper conductor, cable of two runs, 6 Sqmm for phase and neutral and one run of 6 Sqmm for earth wire, drawn through and including PVC casing and caping with all fittings like tee, bends, junction box/terminal box fixed on wall/ground/ceiling etc and connected complete all as specified and directed by Engr-in-Charge. (Note :- Phase should be of Red/Yellow/Blue, neutral should be of black and earthing wire should be of green colour. Two run of cable for phase/neutral and one run of cable for earth will be measured and pais as one unit length).
M&L sub main wiring with proper colour coding, FRLS PVC insulated copper conductor, unsheated, multi-stranded, copper conductor, cable of two runs, 4 Sqmm for phase and neutral and one run of 4 Sqmm for earth wire, drawn through and including PVC casing and caping with all fittings like tee, bends, junction box/terminal box fixed on wall/ground/ceiling etc and connected complete all as specified and directed by Engr-in-Charge. (Note :- Phase should be of Red/Yellow/Blue, neutral should be of black and earthing wire should be of green colour. Two run of cable for phase/neutral and one run of cable for earth will be measured and pais as one unit length).
M&L sub main wiring with proper colour coding, FRLS PVC insulated copper conductor, unsheated, multi-stranded, copper conductor, cable of two runs, 6 Sqmm for phase and neutral and one run of 6 Sqmm for earth wire, drawn through existing conduit and junction box fixed in wall/ceiling etc and connected complete all as specified and directed by Engr-in-Charge. (Note:- Phase should be of Red/Yellow/Blue, neutral should be of black and earthing wire should be of green colour. Two run of cable for phase/neutral and one run of cable for earth will be measured and pais as one unit length).
M&L sub main wiring with proper colour coding, FRLS PVC insulated copper conductor, unsheated, multi-stranded, copper conductor, cable of two runs, 4 Sqmm for phase and neutral and one run of 4 Sqmm for earth wire, drawn through existing conduit and junction box fixed in wall/ceiling etc and connected complete all as specified and directed by Engr-in-Charge. (Note:- Phase should be of Red/Yellow/Blue, neutral should be of black and earthing wire should be of green colour. Two run of cable for phase/neutral and one run of cable for earth will be measured and pais as one unit length).
S&F in repairs MCB DB SPN, 12 way, 240 Volt, double door powder coated sheet steel enclosure for surface mounting fitted with 200 Amps bus bar and din channel complete all as specified and directed.
S&F in repairs MCB DB SPN, 8 way, 240 Volt, double door powder coated sheet steel enclosure for surface mounting fitted with 200 Amps bus bar and din channel complete all as specified and directed.
S&F in repairs MCB DB TPN, 4 way, 415 Volt, double door powder coated sheet steel enclosure for surface mounting fitted with 200 Amps bus bar and din channel complete all as specified and directed.
S&F in repairs MCB TPN, 6 to 32 Amps, ''C'' series 415 Volts, 3 phase, 10 KA breaking capacity of complete all as specified and directed.
S&F in repairs MCB TPN, 40 to 100 Amps, ''C'' series 415 Volts, 3 phase, 10 KA breaking capacity of complete all as specified and directed.
S&F in repairs MCB SPN, 6 to 32 Amps, ''C'' series 230 Volts, single phase, 10 KA breaking capacity complete all as specified and directed.
S&F in repairs MCB SP, 5 to 32 Amps, ''C'' series 230 Volts, single phase, 10 KA breaking capacity complete all as specified and directed.
S&F in repairs single pole and neutral enclosure with a two pin and earth plug and socket industrial type with one MCB 20 Amp double pole 240 Volts complete all as specified and directed.
S&F in repairs switch piano 5 Amps one way flush type complete all as specified and directed.
S&F in repairs switch piano 5 Amps two way flush type, complete all as specified and directed.
S&F in repairs socket outlet 2 in 1, 5 pin, 5 Amps flush type, complete all as specified and directed.
S&F switch socket combination 5 Amps, 2 in one, 3 pin, flush type multi purpose complete all as specified and directed. Havells/Anchor/Cona or equivalent.
S&F in repairs switch piano 15 Amps one way flush type complete all as specified and directed.
S&F in repairs socket outlet 2 in 1, 3 pin, 5 and 15 Amps complete all as specified and directed.
S&F switch socket combination 2 in 1, 3 pin, 5 and 15 Amp, flush type universal complete all as specified and directed.
S&F in repairs ceiling fan regulator electronic five step type 230 Volts single phase complete all as specified and directed.
S&F in repairs bell push 5 Amps 230 volts AC, single pole complete all as specified and directed.
S&F in repairs bell electric (ding dong bell) 230 volts AC, single phase complete all as specified and directed.
S&F in repairs lamp holder, PVC/polycarbonate type with back plate complete all as specified and directed.
“S&F in repair ceiling rose surface bakelite 65 x 50 mm three terminal on and including PVC junction box of suitable size complete all as specified and directed.
S&F in repairs decorative modular switch 6 Amps single pole one way flush type complete all as specified and directed.
S&F in repairs decorative modular switch 6 Amps single pole two way flush type complete all as specified and directed.
S&F in repairs decorative modular socket 6 Amps, 3 pin, flush type, multipurpose complete all as specified and directed.
S&F in repairs decorative modular switch 16 Amps single pole one way flush type complete all as specified and directed.
S&F in repairs decorative modular twin socket 16 Amps, 3 pin, flush type, multipurpose type complete all as specified and directed.
S&F in repair decorative modular ceiling fan regulator electronic five step type 230 Volts single phase complete all as specified and directed.
S&F in repairs bell push 5 Amps modular type complete all as specified and directed.
S&F in repairs of following sizes front plate with base frame for fixing decorative modular switches/ sockets/ regulators etc and matching with existing complete all as specified and directed :- (a) 2 module
(b) 3 module
(c) 4 module
(d) 6 module
(e) 8 module
S&F 18 watt LED Square type surface light fittings 1x1 feet including making necessary connection complete all as specified and directed.
S&F LED down light 18 W of size 175 mm x 175 mm, square surface mounted, opaque diffuser including all accessories, complete all as specified and directed.
S&F LED panel 36 W, square surface mounted of size 2'x2' LED luminare with polymer diffuser including all accessories, complete all as specified and directed.
S&F decorative wall light fixture made up of polycarbonate, suitable for 1x10 W LED lamp (B-22 base) with back plate complete all as specified and directed by Engr-in-Charge.
S&F in repair LED tube light fitting 1x18/20 W, 6500 K, 4 feet long including provn of flexible cable 3 core, 23/.0076 from ceiling rose to connector complete all as specified and directed by Engr-in-Charge.
S&F in repair T8 LED tube rod 18/20 W, 4 feet length, 6000K complete with all as specified and as directed.
S&F in repair 10 watt LED box type light fittings 2 feet including making necessary connection complete all as specified and directed.
Taking down ceiling fan of any sweep, dismantling, removing the existing painting and cleaning the surface and painting with white metalic colour including marking MES No on fan with black colour etc and fixing up in the original location connecting up and testing complete all as directed.
Taking down geysers of 25 Ltr capacity removing the existing painting and cleaning the surface and Spray painting with white metalic colour including marking MES No on geysers with black colour etc and fixing up in the original location connecting up and testing complete all as directed.
S&F in repairs decorative modular 32 Amps DP switch 2 module one way flush type complete all as specified and directed.
Taking down ceiling fan/exhaust fan of any sweep, dismantling, replacing defective part, overhauling, cleaning, greasing, rewinding etc and hanging up/fixing back in the original position, connecting up and testing complete all as directed. Note : (a) The unit rate quoted shall deemed to be included for minor items viz nuts, bolts split pin and rubber wheel etc. (b) Capacitor & bearing shall be measured and paid sperately under ser item Nos 64 & 65 here-in-after. (c) Rewinding of fan will be measured and paid separately under under ser item Nos 66 to 68 here-in-after. (d) Fan blade will be masured and paid separately under under ser item Nos 69 here-in-after. (e) Fan Down rod will be masured and paid separately under under ser item Nos70 here-in-after.
S&F in repairs capacitor of 2.5 mfd for ceiling fan/exhaust fan complete all as specified and directed.
S&F in repairs bearing No 6201/6202/6203 suitable for ceiling fan/exhaust fan complete all as specified and directed.
M&L for removing of burnt out copper winding wire from ceiling fan of any make and size of 1200 mm to 1400 mm sweep including cleaning of slots etc and rewinding with super enameled copper winding wire as per existing size/gauge including insulating material, varnishing and drying complete all as specified and directed.
M&L for removing of burnt out copper winding wire from ceiling fan of any make and size of 300 mm sweep including cleaning of slots etc and rewinding with super enameled copper winding wire as per existing size/gauge including insulating material, varnishing and drying complete all as specified and directed.
M&L for removing of burnt out copper winding wire from ceiling fan of any make and size of 450 mm sweep including cleaning of slots etc and rewinding with super enameled copper winding wire as per existing size/gauge including insulating material, varnishing and drying complete all as specified and directed.
S&F in repairs Fan Blade for ceiling fan complete all as specified and directed.
S&F in repairs Fan Down Rod of any size as per site for ceiling fan complete all as specified and directed.
S&F in repairs LED lamp/Bulb holder suitable for LED Bulb 9/10/11/13/18 W Cross pin type and 2 pin type all as specified and directed.
S&F in repair LED lamp 9/10/11/13/18 watt 230 Volt cross pin type, White/warm white in colour complete all as specified and directed.
S&F in repair LED lamp 2 pin type 9/11/15 W 230 Volts ISI marked, White/warm white in colour all as specified and as directed.
S&F in repair LED Bulb Warm White pin type 9/15 W 230 Volts ISI marked, all as specified and as directed.
S&F in repair ventilator fan AC single phase 230 V of size 200 mm (PVC body) with louvers shutter (white/Ivory) and connected with flexible cord of size 23/0/0076 stranded copper conductor PVC insulated of length not less than 0.7m complete all as specified and directed.
S&F in repair ventilator fan AC single phase 230 V of size 300 mm (PVC body) with louvers shutter (white/Ivory) and connected with flexible cord of size 23/0/0076 stranded copper conductor PVC insulated of length not less than 0.7m complete all as specified and directed.
S & F in repair 15 Amp 3 Pin top complete all as speicfied and directed by Engr-in-Charge.
S & F in repair 10 feet (6 inch) premium Chimney Aluminium exhaust duct pipe with cowl cover complete all as speicfied and directed by Engr-in-Charge.
S & F in repair electric chimney including taking down the old chimney including making electric connection and testing and refixing the same at its original position complete all as specified and directed.
S&F in repair wall mounted fan AC single phase 230 V of size 400 mm sweep with blade white and connected with flexible copper cord of suitable size of length not less than 0.7m complete all as specified and directed. Note : Old unserviceable wall mounted fan will be deposited in MES store by the contractor.
S&F in repairs heating element 1.5 KW of storage type water heaters (geyser) embedded type nickel plated duly mineral filled, ISI Marked complete all as specified and directed.
S&F in repairs heating element 2.0 KW of storage type water heaters (geyser) embedded type nickel plated duly mineral filled, ISI Marked complete all as specified and directed.
S&F in repairs thermostat adjustable between 30 degree C to 85 degree C for geyser complete all as specified and directed.
S&F in repairs PVC connection 15 mm dia 450 mm long (heavy duty) with 2 Nos PTMT nut and washer for cold water complete all as specified and directed.
S&F in repairs brass chrominum plated connection 15 mm dia 450 mm long (heavy duty) with 2 Nos brass chrominum plated nuts and washer for hot water complete all as specified and directed.
S&F in repairs PVC connection 15 mm dia 600 mm long (heavy duty) with 2 Nos PTMT nut and washer for cold water complete all as specified and directed.
S&F in repairs brass chrominum plated connection 15 mm dia 600 mm long (heavy duty) with 2 Nos brass chrominum plated nuts and washer for hot water complete all as specified and directed.
S&F in repairs PVC insulated and sheathed copper multistranded cable three core 2.5 sqmm, heavy duty and connected from plug top to geyser as per site requirement complete all as specified and directed
M&L for earthing complete with galvanized cast iron earth plate electrode 600x600x6 mm thick buried directly in ground (earth pit not less than 2.25 Mtr deep below normal ground level ) with top edge of earth plate not less than 1.5 Mtr below normal ground level connected to galvanized earth lead 4 mm dia by means of bolts, nuts washers and check nuts of steel/GI duly protected with 15mm bore light grade pipe upto main board, 20mm bore watering pipe light grade with CI/MS funnel and wire mesh including excavation, earth work in any type of soil and removing the surplus soil to a distance not exceeding 50 Mtr, char coal dust and common salt in adequate qty all as shown in electrical plate No 3 of SSR Part-I 2009 having pit and cover in PCC 1:2:4 type B-1 including angle iron frame made of angle iron of size 40x40x6mm grouted in PCC pit for PCC cover, funnel with wire mesh complete and all as specified. Note :- The unit rate quoted shall be deemed to include for necessary excavation and earth work, PCC 1:3:6 type CI chamber, funnel with GI medium grade watering pipe 15mm bore, RCC cover slabs 50mm thick with 8mm dia CTD bars @ 140mm c/c both ways etc complete.
S&F in repair LED 70W edge series bldg security light fitting pressure die -cast housing with toughned glass and including LEDs with secondary optics and IP 66 protection complete all as specified and directed.
S&F in repair LED Bulk Head 10W with pressure plastic housing with clear prismatic diffuser, high efficient LEDs IP 65 complete all as specified and directed.
S&F in repairs LED bollard 10W circular cast aluminium bollard with opaque diffuser 900 mm long complete all as specified and directed.
S&F in repair decorative gate or garden light including 1x20 W LED lamp made up of high grade unbreakable polycarbonate material suitable for retrofit LED lamp B22base IP65 complete all as specified and directed.
Supply and fixing in repair SS LED Linear batten size 4' (Polymer) with smart sensor (auto dimmable) , 20 watt, 230 Volts, completed with all connected accessories including connecting up with twin core twisted flexible copper conductor cable of suitable size complete all as specified and directed.
S&F in repairs LED strip light 240 V,10w complete all as specified and directed.
S&F decorative mirror light 20W including making necessary connection complete all as specified and directed.
S&F in repair LED round celing light 6 W surface mounted, opaque diffuser including all accessories, complete all as specified and directed.
S&F in repairs PVC Board of all size as per site all complete all as specified and directed.
S&F in repairs Dummy plate round type of all size as per site requirment complete all as specified and directed.
S&F in repairs Concealed type 32 Amps DP switch one way complete all as specified and directed.
S&F in repairs NRV Valve for geyser as per existing size complete all as specified and directed.
S&F in repairs invertor bulb of size 18 W or any type complete all as specified and directed.
S& F in repair 2 core 6 sqmm copper cable complete all as specified and directied.
Repair only Three/Single phase energy meter 230/415 volt, 10-25 Amp including making incoming and outgoing electric connection and testing including taking down old defective energy meter and depositing the same to MES store yard complete all as specified and directed.
Supply, fixing, insttalations and commisioning in repair of wall mounted powder coated, indoor LT panel of 125 Amp capacity with provision of four meters, three phase, IP 44 standard including aluminium bus bar, 01 Nos of 125 Amp incomer MCCB complete all as specified and directed. Outer shell shall be made of 2.00mm CRCA sheet Incoming 125 Amp MCCB-01 Nos Red indicating Lamp with integrated LED volt 230V AC-01 Nos Yellow indicating Lamp with integrated LED volt 230V AC-01 Nos Blue indicating Lamp with integrated LED volt 230V AC-01 Nos Multifunction meter (LED Display ), 3 Phase, Parameters : V,A,F, Meter 32A Neutral link, channel mounting Outgoing SP 40 Amp -04 Nos SP 10 Amp-06 Nos Bus bar A set of 200A 25K Electrolyte grade Aluminium Busbar Aluminium Earth bus bar-25X6mm
S&F LED tube light fitting 1x18/20 W, 6500 K, 4 feet long including provn of flexible cable 3 core, 23/.0076 from ceiling rose to connector complete all as specified and directed by Engr-in-Charge.
S&F switch piano 5 Amps one way flush type complete all as specified and directed.
PEGASOS ENGINEER TRADERS (BID ID -3486584)
SRI GURUPRASAD INFRATECH (BID ID -3483029)
SIRI SALES AND SERVICES (BID ID -3486363)
LEKSHMI ENGINEERS (BID ID -3486394)
ANKIT SHIP REPAIRERS AND SUPPLIERS (BID ID -3487694)
MAKARAND MARINE SERVICES (BID ID -3482758)
HARSHITA MARINE SERVICES (BID ID -3486088)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.24 MB
BOQ_826723.xls
BOQ • 0.30 MB
86017TENDER.pdf
Tender Documents • 0.71 MB
Download all tender documents and submit your bid