| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.3 CrAccepted-AOC 2A IHDP BUSINESS PARK SECTOR 127 NOIDA UTTAR PRADESH 201304 | NOIDA | GAUTAM BUDDHA NAGAR | UTTAR PRADESH | 201304 | ₹12.3 Cr | L1 | Accepted-AOC L1 bidder quoted rate found reasonable |
| 2 | L2₹15.0 CrRejected-Finance ONLOOKER BUILDING 3RD FLOOR 25 SHRI P M ROAD FORT MUMBAI 400 001 | MUMBAI | MAHARASHTRA | 400001 | ₹15.0 Cr | L2 | Rejected-Finance Other than L1 |
| 3 | Rejected-Technical VILL CHOMON NEAR MAIN GUARD ROOM AIR FORCE STATION ADAMPUR DISTT JALANDHAR PB 144103 | JALANDHAR | PUNJAB | 144103 | - | - | Rejected-Technical Not Eligible due to there is no provision Criteria in NIT for admitting the Contractors who are two class below the eligible class for working area other than remote/difficult areas. Hence the firm does not eligible |
| 4 | Rejected-Technical | - | - | Rejected-Technical Not Eligible due to there is no provision Criteria in NIT for admitting the Contractors who are two class below the eligible class for working area other than remote/difficult areas. Hence the firm does not eligible |
| Sl No | Description | Qty | Unit | Idustrial products India L2 | ANEKTOS HYBRID BUILDINGS PRIVATE LIMITED L1 |
|---|---|---|---|---|---|
| 1.00 | Lump sum price worked out by the contractor for "BUILDING WORKS" as listed in Schedule ‘A’ Part-I representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES | 1 | LUMP SUM | 10,05,00,000 ₹10.1 Cr | 7,50,00,000 ₹7.5 Cr |
| 2.00 | Lump sum price worked out by the contractor for "INTERNAL WATER SUPPLY " as listed in Schedule ‘A’ Part-II representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES | 1 | LUMP SUM | 8,640 ₹8,640 | 18,000 ₹18,000 |
| 3.00 | Lump sum price worked out by the contractor for "INTERNAL ELECTRIFICATION" as listed in Schedule ‘A’ Part-III representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES | 1 | LUMP SUM | 28,24,538 ₹28.2 L | 35,34,696 ₹35.3 L |
| 4.00 | Lump sum price worked out by the contractor for "ROAD, PATH AND CULVERT" as listed in Schedule ‘A’ Part-IV representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES | 1 | LUMP SUM | 1,65,79,193 ₹1.7 Cr | 1,69,32,848 ₹1.7 Cr |
| 5.00 | Lump sum price worked out by the contractor for "CABLE DUCT" as listed in Schedule ‘A’ Part-V representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES | 1 | LUMP SUM | 20,25,654 ₹20.3 L | 17,06,916 ₹17.1 L |
| 6.00 | Lump sum price worked out by the contractor for "AREA DRAINAGE " as listed in Schedule ‘A’ Part-VI representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES | 1 | LUMP SUM | 40,75,670 ₹40.8 L | 30,87,153 ₹30.9 L |
| 7.00 | Lump sum price worked out by the contractor for "RAIN WATER HARVESTING" as listed in Schedule ‘A’ Part-VII" representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES | 1 | LUMP SUM | 41,53,668 ₹41.5 L | 36,05,117 ₹36.1 L |
| 8.00 | Lump sum price worked out by the contractor for "EXTERNAL WATER SUPPLY" as listed in Schedule ‘A’ Part-VIII representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price of prepriced by the MES | 1 | LUMP SUM | 7,89,640 ₹7.9 L | 4,43,409 ₹4.4 L |
| 9.00 | Lump sum price worked out by the contractor for "EXTERNAL ELECTRIFICATION" as listed in Schedule ‘A’ Part-IX representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price of prepriced by the MES | 1 | LUMP SUM | 36,32,855 ₹36.3 L | 30,99,538 ₹31.0 L |
| 10.00 | Lump sum price worked out by the contractor for "SITE CLEARANCE, SITE DEVELOPMENT AND EARTH WORK" as listed in Schedule ‘A’ Part-X representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES | 1 | LUMP SUM | 37,15,586 ₹37.2 L | 35,20,640 ₹35.2 L |
Tender Value
₹12.3 Cr
EMD Value
₹9.4 L
Closing Date
9 Apr 2026, 6:00 pmClosed
CHIEF ENGINEER JAIPUR ZONE JAIPUR
HEAD QUARTER CHIEF ENGINEER JAIPUR ZONE JAIPUR
CONSTRUCTION OF 10 MG ACCN (PHASE-II) AT JAIPUR MIL STATION
2025_MES_732041_3
80816
Open Tender
Civil Works
365 days
GE (S) Jaipur
Please refer to tender documents
8 documents required · 8 mandatory
₹3,000
GE (S) Jaipur
₹9.4 L
Yes
HEAD QUARTER CHIEF ENGINEER JAIPUR ZONE JAIPUR
5 May 2026
12 Mar 2026
11 Apr 2026
12 Mar 2026
9 Apr 2026
2 Apr 2026
17 Mar 2026
Lump sum price worked out by the contractor for "BUILDING WORKS" as listed in Schedule ‘A’ Part-I representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES
Lump sum price worked out by the contractor for "INTERNAL WATER SUPPLY " as listed in Schedule ‘A’ Part-II representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES
Lump sum price worked out by the contractor for "INTERNAL ELECTRIFICATION" as listed in Schedule ‘A’ Part-III representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES
Lump sum price worked out by the contractor for "ROAD, PATH AND CULVERT" as listed in Schedule ‘A’ Part-IV representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES
Lump sum price worked out by the contractor for "CABLE DUCT" as listed in Schedule ‘A’ Part-V representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES
Lump sum price worked out by the contractor for "AREA DRAINAGE " as listed in Schedule ‘A’ Part-VI representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES
Lump sum price worked out by the contractor for "RAIN WATER HARVESTING" as listed in Schedule ‘A’ Part-VII" representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES
Lump sum price worked out by the contractor for "EXTERNAL WATER SUPPLY" as listed in Schedule ‘A’ Part-VIII representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price of prepriced by the MES
Lump sum price worked out by the contractor for "EXTERNAL ELECTRIFICATION" as listed in Schedule ‘A’ Part-IX representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price of prepriced by the MES
Lump sum price worked out by the contractor for "SITE CLEARANCE, SITE DEVELOPMENT AND EARTH WORK" as listed in Schedule ‘A’ Part-X representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES
Sch 'A' Part-XI MISC ITEMS (TO BE QUOTED BY CONTRACTOR) Notes: (i) This schedule is not pre-priced by MES and the pre-priced rate indicated as "Rs 0.00" under column 5 signifies this fact only. (ii) Excavation and earth work except for the items which categorically includes for same shall be measured and paid separately under SCH A PART-X (SITE CLEARANCE, SITE DEVELOPMENT AND EARTH WORK schedule).
INTERNAL WATER SUPPLY S&F of concealed body single lever brass CP mixer-diverter for mixing hot and cold water, including exposed part kit (wall plate and spout) screwed for iron pipe 15mm bore (minimum total weight of concealed and exposed part 1400 gram); conforming to low-flow SVA GRIHA norms (6-7.5 lpm) etc.complete all as specified and directed. (Make : Jaquar, Marc, Kohler, Roca, Grohe)
S&F concealed body single lever brass CP mixer-diverter for mixing hot and cold water with provn of hand shower (with spout but without hand shower dual shower and spout) outlet exposed part kit (wall plate and shower controller knob), screwed for iron pipe 15mm bore (minimum total weight of concealed and exposed part 1500 gram); conforming to low-flow SVA GRIHA norms (6-7.5 lpm) etc.complete all as specified and directed. (Make : Jaquar, Marc, Kohler, Roca, Grohe)
S&F of chromium plated cast copper alloy fancy type hand shower 105mm Round shape multi flow Rain Massage) with Air effect (ABS body & face plate chrome plated) with Rubit cleaning system, screwed for iron pipe 15mm bore, fixed in repairs; conforming to low-flow SVA GRIHA norms (6-7.5 lpm) etc.complete all as specified and directed. (Make : Jaquar, Marc, Kohler, Roca, Grohe)
S&F of chromium plated cast copper alloy stop valves, angle type (minimum weight 575 gram), screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe 15mm bore etc.complete all as specified and directed. (Make : Jaquar, Marc, Kohler, Roca, Hindware, Parryware, Cera)
S&F of stop valves fancy type, chromium plated with long shank and cup (concealed type), cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions 15mm bore. (minimum total weight 650 gram) etc.complete all as specified and directed. (Make : Jaquar, Marc, Kohler, Roca, Grohe)
S&F of chromium plated cast copper alloy fancy type long body bib taps (minimum weight 575 gram) with capstan heads screwed down high pressure with long screwed shanks and fly nuts, screwed for iron pipe 15mm bore; conforming to low-flow SVA GRIHA norms (6-7.5 lpm) etc.complete all as specified and directed. (Make : Jaquar, Marc, Kohler, Roca, Grohe)
S&F of chromium plated cast copper alloy fancy type bib tap and stop cock combination (minimum weight 800 gram) with capstan heads screwed down high pressure with long screwed shanks and fly nuts, screwed for iron pipe 15mm bore; conforming to low-flow SVA GRIHA norms (6-7.5lpm) etc.complete all as specified and directed. (Make : Jaquar, Marc, Kohler, Roca, Grohe) Note for item No. 12 to 18 : (i) Items shall be from same series of any of the makes mentioed against these items to maintain uniformity. (ii) Make/model/brand/cat part No. of these items shall be approved by GE. The decision of GE for approval of Make/model/brand/cat part No. shall be final
S&F of brass chromium plated 200mm dia round or square shower rose with swivel joints, fixing in repairs to 15mm bore steel pipe or union; conforming to low-flow SVA GRIHA norms (6-7.5lpm) etc.complete all as specified and directed. (Make : Jaquar, Marc, Kohler, Roca, Grohe)
S&F of CP brass health faucet 1 meter long flexible tube and wall hook complete, fixed in repairs; conforming to low-flow SVA GRIHA norms (6-7.5 lpm) etc.complete all as specified and directed. (Make : Jaquar, Marc, Kohler, Roca, Grohe)
INTERNAL ELECTRIFICATION S&F of TV socket 1 module 230 volts AC complete all as specified and directed.
Supply and install, testing wall termination Telephone socket RJ-11 complete all as specified and directed
S & F blanking plate complete all as specified and directed.
S&F of lamp holder, including 9 watt LED Bulb insulated body with back plate suitable for batten fittings and complete all as specified and directed
S & F for wall mounting fan, 230 Volts, 50Hz, 300 mm sweep 4 star rated with swing/oscillation type, with necessary accessories for wall mounting fan and electrical connections from ceiling rose to fan teriminal including writting the MES Number with synthetic enamel paint complete all as specified and directed
M&L for Loose filling with broken stone or boulders of gauge 40 to 60 mm complete all as specified and directed
M&L for Loose filling with gravel of gauge 3 to 10 mm complete all as specified and directed
M&L for 550mm dia boring hole in rainwater harvesting pit in any type of soil for PVC/HDPE pipe 150mm bore upto 52 metre deep complete all as specified and shown in drawings.
M&L for 150mm bore PVC/HDPE pipe in bore hole complete all as specified and shown in drawings.
M&L for 150mm bore perforated PVC/HDPE pipe in bore hole complete all as specified and shown in drawings.
EXTERNAL WATER SUPPLY Supply, Laying, jointing & testing of Ductile Iron (DI) of size 100mm dia, pressure pipeswith spigot and socket ends, centrifugally cast, class K-7, with cement mortar lining in inner side as per IS:8329-2000 (Latest revision) and other relevant standards and metallic zinc coating followed by a finishing layer of epoxy paint in outer side, suitable for push on joint (rubber gasket joint) in any length with inside cement mortar lining laid in trenches complete all as specified and as directed.
M&L for construction of brick / stone masonry valve pit / chamber of size 900 mm x 600 mm x 1000 mm (internal Dimensions) and all as shown in drawing No TD-573, including necessary excavation and earth work, PCC, plaster in CM 1:6 on inside and outside (above ground), angle iron frame 40 x 40 x 6 mm frame work, hold fast, MS sheet cover 3 mm thick, duly painted with one coat of bituminous paint of approved quality, handle and locking arrangements complete, incl provn of 40 mm dia Godrej (freedom) lock, complete all as specified and as directed.
M&L for construction of brick / stone masonry valve pit / chamber of size 600 mm x 600 mm x 900 mm (internal Dimensions) and all as shown in drawing No TD-573, including necessary excavation and earth work, PCC, plaster in CM 1:6 on inside and outside (above ground), angle iron frame 40 x 40 x 6 mm frame work, hold fast, MS sheet cover 3 mm thick, duly painted with one coat of bituminous paint of approved quality, handle and locking arrangements complete, incl provn of 40 mm dia Godrej (freedom) lock, complete all as specified and as directed.
M& L for cutting of existing pipeline of Exisiting 200 mm Dia Header and Connecting of New pipe including all nessary material such as joint, nut bolts, etc as required at site and complete all as specified and as directed.
M& L for cutting of existing pipeline of 200/100/80/50/40 mm Dia Connecting of new pipe including all nessary material such as joint, nut bolts, etc as required at site and complete all as specified and as directed.
M&L for taking up and down of CI/DI/GI Pipe Line of 100 mm including all connected items etc as required at site and complete all as specified and as directed.
M&L for taking up and down of CI/DI/GI Pipe Line of 80 mm including all connected items etc as required at site and complete all as specified and as directed.
M&L for taking up and down of CI/DI/GI Pipe Line of 50 mm including all connected items etc as required at site and complete all as specified and as directed.
M&L for taking up and down of CI/DI/GI Pipe Line of 40 mm including all connected items etc as required at site and complete all as specified and as directed.
EXTERNAL ELECTRIFICATION . Supply, laying and testing cable XLPE cable cross sectional area size 185 sqmn 3 core insulated screened PVC bedded, galvanised steel strip or wire armoured elec power cable heavy duty with aluminium conductor 33 KV (E) grade complete all as specified and as directed.
Supply and fixing HT cable/route indicator cast iron of suitable size along HT cable trench including planting in ground with PCC complete all as specified and directed.
Supply, installing, testing and commissioning, factory made and tested , (including CPRI type tested and certified ) outdoor type , plateform mounted LT panel board, KIOSK type suitable for 415 volts, 3 phase 4 wire 50 Hz, AC supply system having bus bar chamber with insulated copper bus bars 500 Amps rating installed on porcelain insulators. The panel shall be dust and vermin proof, IP-64 Protection class and made out of 3.15 mm CRCA MS sheet and 40 x 40 x 6 mm thick angle iron frame work in the bottom of the panel , powder coated finish over one coat of red oxide primer ,
front & rear opening type, including internal connection with suitable size of insulated copper bus bar , 1100 volts grade , and panel to be suitabely grouted on the plateform with necessary arrangements including marking of incoming and out going feeders including danger notice plate and accessories and comprising of the following :- (TR main LT panel) Incoming :- (i) MCCB 320 amp, 4 pole, 36 KA, with thermal magnetic based with integral over load, short circuit & earth fault & neutral protection, 50 Hz, 415 volts grade - 01 No. (ii) Digital Metering 3 phase combined Voltmeter, Ammeter& Frequency Meter (iii) Suitable CT's (iv) LED Indicating lamps : 01 set of three (v) Onload Changeover 320 Amps, 415 Volts grade: 01 no Outgoing :- (i) MCCB 4P, 415 Volts grade, 160 Amps rating and 25 KA rupturing capacity , : 02 nos ( For FP-1 & 3) (ii) MCCB 4P, 415 Volts grade, 125 Amps rating and 25 KA rupturing capacity : 02 nos (For FP 2 & 4) (iii) Auto Timer switch with connector, 36 Amps including bus bar : 01 nos (iv) MCCB 4P, 415 Volts grade, 25 Amps rating and 16 KA rupturing capacity , : 01 nos (Security Light) (v) MCCB 4P, 415 Volts grade, 125 Amps rating and 25 KA rupturing capacity , : 01 nos (APFC Panel) Note : (i) All out going feeders shall be connected by cable through suitable size gland plate / glands. (ii) The various feeders shall be indicated by 50 mm size letters in synthetic enamel white paint.
Supply, installing, testing and commissioning, factory made and tested , (including CPRI type tested and certified ) outdoor type , plateform mounted LT panel board, KIOSK type suitable for 415 volts, 3 phase 4 wire 50 Hz, AC supply system having bus bar chamber with insulated copper bus bars 250 Amps rating installed on porcelain insulators. The panel shall be dust and vermin proof, IP-64 Protection class and made out of 3.15 mm CRCA MS sheet and 40 x 40 x 6 mm thick angle iron frame work in the bottom of the panel , powder coated finish over one coat of red oxide primer , front & rear opening type, including internal connection with suitable size of insulated copper bus bar , 1100 volts grade , and panel to be suitabely grouted on the plateform with necessary arrangements including marking of incoming and out going feeders including danger notice plate and accessories and comprising of the following :- (FP-03 & 4) Incoming:- (i) MCCB 4P, 415 Volts grade, 160 Amps rating and 25 KA rupturing capacity , : 01 nos (ii) Digital Metering 3 phase combined Voltmeter, Ammeter& Frequency Meter (iii) Suitable CT's (iv) LED Indicating lamps : 01 set of three
OutGoing:- (i) MCCB 4P, 415 Volts grade, 63 Amps rating and 16 KA rupturing capacity , : 03 nos (For BG No-5,6 & 7) and ( BG No-8,9 & 10) (ii) MCB 2P, 10 Amps , 240 Volts , 10 KA -01 Nos Note : (i) All out going feeders shall be connected by cable through suitable size gland plate / glands. (ii) The various feeders shall be indicated by 50 mm size letters in synthetic enamel white paint.
Supply, installing, testing and commissioning, factory made and tested , (including CPRI type tested and certified ) outdoor type , plateform mounted LT panel board, KIOSK type suitable for 415 volts, 3 phase 4 wire 50 Hz, AC supply system having bus bar chamber with insulated copper bus bars 200 Amps rating installed on porcelain insulators. The panel shall be dust and vermin proof, IP-64 Protection class and made out of 3.15 mm CRCA MS sheet and 40 x 40 x 6 mm thick angle iron frame work in the bottom of the panel , powder coated finish over one coat of red oxide primer , front & rear opening type, including internal connection with suitable size of insulated copper bus bar , 1100 volts grade , and panel to be suitabely grouted on the plateform with necessary arrangements including marking of incoming and out going feeders including danger notice plate and accessories and comprising of the following :- (FP-01 & 02 ) Incoming:- (i) MCCB 4P, 415 Volts grade, 125 Amps rating and 36 KA rupturing capacity , Micprocessor based : 01 nos (ii) Digital Metering 3 phase combined Voltmeter, Ammeter& Frequency Meter (iii) Suitable CT's (iv) LED Indicating lamps : 01 set of three
OutGoing:- (i) MCCB 4P, 415 Volts grade, 63 Amps rating and 16 KA rupturing capacity , : 02 nos (For BG No-1 & 2) and ( BG No-3 & 4) (ii) MCB 2P, 10 Amps , 240 Volts , 10 KA -01 Nos Note : (i) All out going feeders shall be connected by cable through suitable size gland plate / glands. (ii) The various feeders shall be indicated by 50 mm size letters in synthetic enamel white paint..
Supply and fixing poly carbonate junction box , weather and vermin proof of suitable size 250x250x160 including provn of 2 Nos aluminium strip 25x3.15 mm size bus bar single phase and neutral suitabely mounted on bus bar insulators , including one No. MCB SP 6 Amps for light control,drilling of holes.Provn of suitable size of GI nuts, bolts, double washer and FI clamps of suitable size for taking connections and fixing on LT steel tubular poles complete with locking arrangement complete all as specified and directed
Supply install & testing sonora gate light decorative luminaries of 15 Watt LED with complete all as per directed
Material and labour for cable straight through jointing kit of size 185 sqmn 3 core HT 33 KV grade, heat shrinkable, outdoor type complete with jointing material suitable for HT XLPE, complete all as specified and directed.
Taking out old cable XLPE cable insulated screened PVC bedded, galvanised steel strip or wire armoured elec power cable cross sectional area 95 sqmn 3 core heavy duty with aluminium conductor 11 KV (E) grade complete all as specified and directed.
Supply , install, testing and commissioning of 11kV 630 Amps 21KA for 3 Sec. SF6 insulated, One side extensible, outdoor duty (IP54) 3 way Ring main unit, motor operated, with all VCB modules, consisting of copper busbar in SF6 insulated 304 (Non-Ferrite Non-Magnetic Grade) stainless steel enclosure of thickness 2.5mm with manometer fixed on the tank. The Breaker shall have mechanical ON /OFF indicator with hand trip device and spring charging, spring release coil, auxiliary switch of 2 NO +2NC. The HV switchgear and control gear should be confirming to IEC-62271-100, IEC-62271-200-2003 & IEC-60694-1996. The RMU gas tank should be internal arc tested for 21KA for 1Second with IAC-AFLR classification for gas tank. The complete RMU mimic and cable chamber should be covered by a single door to have ingress protection of minimum IP54. The RMU design should support site replaceable HT cable bushing and VI of VCB should be RMU Manufacturer’s own make. All the type test certificated as per IEC from Third party lab to be submitted.
RMU Should have followings: - 1 no. microprocessor based Self powered numerical relay with over Current/ earth fault & short circuit protection with each VCB feeder. The relay should be of ABB / SIEMENS / SCHNEIDER/ASHIDA/C&S make only. - 3 Nos. Protection CT shall be of Burden 2.5VA, ratio 100/1A, Class of Accuracy class 5P10 for O/C and E/F protection for each VCB. (CT ration is indicative and may vary during detailed engineering ) -1 NO. Manometer for each tank -1 NO Voltage passage indicator for each feeder. - 1 nos. Fault Passage indicator for each LBS module. -Right angle boots for all the feeder Modules - Vacuum Interrupter & RMU should be of same make for better life cycle optimization. - VCB module should confirm to O-0.3Sec-CO-3min-CO operating sequence
.- VCB modules should confirm to 10000 mechanical operation without any Maintenence. - Basic insulation level of complete system shall be 28KV(RMS)/75KV(Peak) - 1 set 1000VA, 11KV/230V , Auxiliary PT for Battary & Charger - 1 Set 12VX2-24V Battary & Charger for motorized operation. (System house /Franchise/ license partnar are not approved)
Taking out old cable XLPE cable insulated screened PVC bedded, galvanised steel strip or wire armoured elec power cable, cross sectional area 185 sqmn 3 core heavy duty with aluminium conductor 11 KV (E) grade complete all as specified and directed.
Taking out old cable XLPE cable insulated screened PVC bedded, galvanised steel strip or wire armoured elec power cable, cross sectional area 185 sqmn 3 core heavy duty with aluminium conductor 33 KV (E) grade complete all as specified and directed.
M & L for 100mm boring of holes under road, pavments, hard standing all as specified and directed
Supply and fixing GI bracket 1.5 mtr 40 mm dia light grade pipe bend to suiatable shape for street light fixing complete all as per directed
SEWAGE DISPOSAL:- Supply and installation factory made precast RCC circular manhole riser units for factory made precast RCC manhole type 2b (internal dia 1200mm) conforming to IS 17725:2022; minimum wall thickness 125mm and height of riser 300mm complete all as specified and directed
Supply and installation factory made precast RCC circular manhole riser units for factory made precast RCC manhole type 2b (internal dia 1200mm) conforming to IS 17725:2022; minimum wall thickness 125mm and height of riser 450mm complete all as specified and directed
Supplying & laying of double wall corrugated structured wall pipes with hollow annular profiled outer surface and a smooth inner surface internal diameter (DN/ID) 150mm of stiffness class designation SN 8 (conforming to IS 16098 (Part 2) : 2013 spigot and socket ended pipe) at site including cement concrete 1:4:8 type D2 (40mm graded stone aggregate) bedding, jointing with rubber gasket, hydraulic testing, making connection to old or new manholes (including dismantling and making good the manhole walls) complete all as specified and directed
Supplying & laying of double wall corrugated structured wall pipes with hollow annular profiled outer surface and a smooth inner surface internal diameter (DN/ID) 200mm of stiffness class designation SN 8 (conforming to IS 16098 (Part 2) : 2013 spigot and socket ended pipe) at site including cement concrete 1:4:8 type D2 (40mm graded stone aggregate) bedding, jointing with rubber gasket, hydraulic testing, making connection to old or new manholes (including dismantling and making good the manhole walls) complete all as specified and directed
Supply and installation factory made precast RCC circular manhole base slab and base riser for factory made precast RCC manhole type 2b (internal dia 1200mm) conforming to IS 17725:2022; minimum wall thickness 125mm and minimum base slab thickness 150mm; height of riser 300mm with benching for pipe 150/200mm dia cast monolithically without base slab projection complete all as specified and directed
Supply and installation factory made precast RCC circular manhole riser units for factory made precast RCC manhole type 2b (internal dia 1200mm) conforming to IS 17725:2022; minimum wall thickness 125mm and height of riser 900mm complete all as specified and directed
Supply and installation factory made precast RCC circular manhole cone units for factory made precast RCC manhole type 2b (internal dia 1200mm) conforming to IS 17725:2022; minimum wall thickness 125mm and 900mm clear height of sloped portion complete all as specified and directed
Supply and installation factory made precast RCC manhole covers with frame grade designation LD-10 medium duty circular type with clear opening of frame 560mm conforning to IS 12592:2002 complete all as specified and directed Note for Item No. 55 to 62 :- Excavation, returning and removal of item No. 55 to 62 shall be measured and paid separetely in schedule 'A' Part-X (SITE CLEARANCE, SITE DEVELOPMENT AND EARTH WORK)
BOUNDARY WALL PRECAST ELEMENTS : Providing, transportation, fixing, erection and installation etc complete for RCC precast Elements for various sizes shapes and steel, including mould making, providing and fixing reinforcement steel, casting with required admixtures, demoulding, curing, transportation, storage, erection at site, grout filling etc for Foundation precast 100 mm thick with connectors for walls 610 wide complete all as specified and directed.
PRECAST ELEMENTS : Providing, transportation, fixing, erection and installation etc complete for RCC precast Elements for various sizes shapes and steel, including mould making, providing and fixing reinforcement steel, casting with required admixtures, demoulding, curing, transportation, storage, erection at site, grout filling etc for Walls precast 100 mm thick for boundary wall having lifting hooks on the top for fixing the angle complete all as specified and directed.
GATE M&L for Wicket gate with RCC pillar incl excavation in any type of soil, plastering, painting etc complete all as specified and shown in TD /2004/15 sh 1/2 to 2/2 CE Jaipur Zone Note for Item No. 63 to 65 :- Excavation, returning and removal of item No. 63 to 65 shall be measured and paid separetely in schedule 'A' Part-X (SITE CLEARANCE, SITE DEVELOPMENT AND EARTH WORK)
ELECTRIC CHIMNEY Supply Installatoin and testing of Electric Chimney Air Flow capacity - 1200 Cum/hrs, Material - CRCA & glass, Noice level 62 dB Mounting Type - wall mount, control type - Motion sensor/Touch, Voltage-220V Nos of speed - 3, Weight - 9.5 Kg, Light source type LED, Wattage -203 Watt Filter Type Filter less, Item form Curved, ventilation type Duct less / recirculating Vent hood design wall mounted canopy hood, Annual Energy consumption- 190 KW hour, Special feature - Oil collector Nos of vents - 01, dimension - 49D x 60 W x 49.5H Centimeters (5% variation permissible), Finish type - Glazed complete all as specified and directed.
Supply and fixing PVC Flexible 110 mm dia pipe suitable for Electrical chimney complete all as specified and directed.
S&F for 450x450x900mm Sikandra stone chhattris complete all as shown on drawings and directed.
Please Enable Macros to View BoQ information
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.43 MB
BOQ_846876.xls
BOQ • 0.38 MB
Drawing80816_3rdcall.pdf
Additional Documents • 20.44 MB
Tender80816_3rdcall.pdf
Tender Documents • 13.61 MB
Download all tender documents and submit your bid