Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.4 LAccepted-AOC 24 SHANTI BHAWAN DHARI ROAD BELTARI PITHORAGARH UTTARAKHAND 262520 | PITHORAGARH | UTTARAKHAND | 262520 | ₹32.4 L Quoted ₹34.0 L | L1 | Accepted-AOC Accepted being L1 bidder |
| 2 | L2₹34.6 L+₹62,254 (1.83%)Rejected-Finance NEAR JAMIA MASJID HOSPITAL ROAD UDHAMPUR J K 182101 | UDHAMPUR | JAMMU AND KASHMIR | 182101 | ₹34.6 L+₹62,254 (1.83%) | L2 | Rejected-Finance Not being L1 bidder |
| 3 | L3₹34.8 L+₹80,559 (2.37%)Rejected-Finance | ₹34.8 L+₹80,559 (2.37%) | L3 | Rejected-Finance Not being L1 bidder |
| 4 | L4₹38.8 L+₹4.8 L (14.3%)Rejected-Finance PANTHAL KATRA REASI J K 182320 | REASI | JAMMU AND KASHMIR | 182320 | ₹38.8 L+₹4.8 L (14.3%) | L4 | Rejected-Finance Not being L1 bidder |
| 5 | L5₹40.4 L+₹6.4 L (18.7%)Rejected-Finance | ₹40.4 L+₹6.4 L (18.7%) | L5 | Rejected-Finance Not being L1 bidder |
Tender Value
₹50.0 L
EMD Value
₹1 L
Closing Date
7 Oct 2023, 6:00 pmClosed
GARRISON ENGINEER SOUTH UDHAMPUR
GE SOUTH UDHAMPUR
REPAIR MAINTENANCE OF CERTAIN PART OF GEYSERS, CEILING FAN EXHAUST FAN CABIN WALL FAN AND ALLIED WORKS UNDER GE SOUTH UDHAMPUR
2023_MES_617933_1
GE/S(U)- /2023-24
Open Tender
Electrical and Maintenance Works
Works
330 days
GE SOUTH UDHAMPUR
As per NIT
9 documents required · 9 mandatory
₹500
GE SOUTH UDHAMPUR
₹1 L
30 Oct 2023
9 Sept 2023
10 Oct 2023
9 Sept 2023
7 Oct 2023
23 Sept 2023
Amount
Taking up/down carefully ceiling fans 1200/1400 mm sweep and exhaust fan/pedestal/air circulator Fan/ wall mounted fan any size, any sweep, from various bldgs (Or collecting from MES E/M Store Yard) as directed, opening up for servicing/repairaing, removing dust and dirt ,cleaning fan motor with cotton/waste malmal, washing blades with detergent powder, servicing/Oiling, Lathe work if any required and greasing of fan of any size/type by using approprite grade of oil/grease and Replacing defective parts such as armature, conopy, Fan blade, Ball bearing, Fan down rod, shutter/louvers , MS shaft, bush, bearing split pin, rubber bush , holding clamp, capacitor ,MS clamps, rubber packing, split pins rubber reel etc, for the smooth and satisfactory functioning, and reassembling complete, re-fixing ceiling fan /exhaust fan with proper PVC flexible pipe 20 mm dia, in same position ( or deposited to MES Store Yard ) , connecting to copper flexible cable 40/.0076 size to electrical system and including proper testing complete all as specified and directed. Note: (a) Replacement of unserviceable parts shall be measured and paid for separately under respective items as S & F in repair. (b) On testing after completion of repair , if the proper speed/smootheness is not obtained at Engr-in- charge satisfaction level , the repairing will be re- done by the contractor at his own costs and the same shall be deemed to be included in the quoted rates. (c) The contractor shall maintain/open a Workshop and keep his electrician ready during working Hrs ( 0900 Hrs to 1700 Hrs ) for repair/rewinding pupose, inside MES store Yard so that all the repairing/ rewinding of Fans will be done in proper manner, MES authorities will not be issue any Fans ,any type, for repair/rewinding puropse to the contractor for his outside workshop.
Rewinding & Painting (painting with two Coats of synthetic asian paints) of AC ceiling fan motor 240 volt, 50 Hz, 1200 mm sweep of any make with super enameled copper winding wire of existing size including sleeve work, varnishing with ‘B’ class insulation varnish, connection with flexible copper wire 0.472mm dia upto connector block, complete all as specified and as directed. (Motor shall be wound with machine with same No of turns as per existing.)
All as per Srl Item No 2 above but Ceiling Fans of 1400 mm sweep complete all as specified and as directed.
Rewinding & Painting (painting with two Coats of synthetic asian paints) of exhaust fan motor 240 volt, 50 Hz, 300/380 mm sweep of any make with super enameled copper winding wire of existing size including sleeve work, varnishing with ‘B’ class insulation varnish, connection with flexible copper wire 40/.0076mm dia upto connector block complete all as specified and as directed. (Motor shall be wound with machine with same No of turns as per existing.)
All as per Srl item No 4 above but exhaust fans/ wall mounting fan of 450 mm sweep complete all as specified and as directed.
S & F in repair Capacitor AC 415 volts 2.5 mfd 50 HZ complete all as specified and as directed.
All as per Srl item No 6 above but 3.15 mfd 50 Hz complete all as specified and as directed.
S & F in repair exhaust fan MS shaft for 300 mm to 450 mm size complete all as specified and as directed.
S & F in repair ball bearing suitable for ceiling fan for 1200 mm sweep complete all as specified and as directed.
S & F in repair ball bearing suitable for ceiling fan for 1400 mm sweep complete all as specified and as directed.
S & F in repair ball bearing suitable for exhaust fan /pedestal fan/air circulator/table fan complete all as specified and as directed.
S & F in repair MS fan blade set suitable for Steel body exhaust fan of 300mm sweep as required, complete and all as specified and directed.
S & F in repair fan blade set heavy duty suitable for PVC/steel exhaust fan/pedestal/air circulator fan upto 450 mm sweep as required complete all as specified and as directed.
S & F in repair ceiling fan blade set 1200 mm sweep complete all as specified and as directed.
S & F in repair ceiling fan blade set 1400 mm sweep complete all as specified and as directed.
S & F in repair down rod 30 cm long of ceiling fan 1200/1400mm sweep including clamps, reels lock nuts, split pin etc complete all as specified and as directed.
S & F in repair PVC insulated twin core twisted copper flexible cable of size 23/0.0076 from connector block to ceiling rose and making connection complete all as specified and as directed.
S & F in repair upper / lower canopy for 1200/1400 mm sweep ceiling fans complete all as specified and as directed.
Supply and fixing in repair shutter / louver of MS sheet for of size 300 to 450 mm sweep for exhaust fan with fixing arrangement complete all as specified and as directed.
S & F in repair armature for celling fan suitable for 1200mm sweep with prewired copper wound armature complete all as specified and as directed.
S & F in repair armature for celling fan suitable for 1400mm sweep with prewired copper wound armature complete all as specified and as directed.
S & F in repair Holding clamp for capacitor of ceiling Fans 1200/1400 mm sweep complete all as specified and as directed.
S & F in repair MS Clamps for hanging purpose of ceiling fan with proper rubber reel packing complete all as specified and as directed.
S & F in repair ceiling fans, MS shaft of standard size 1200 mm to 1400 mm size complete all as specified and as directed.
S&F in repair Rigid non-metallic PVC conduit 20 mm enclusive of boxes (junction/ terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc complete all as specified and as directed.
S&F in repair Fan regulator stepped type electronic fan regulator flush type on the existing laminated sheet complete all as specified and as directed.
S & F in repair electronic dimmers, 450W, 250V flush type on the exiting phenolic laminated sheet etc. as required complete all as specified and as directed.
Repair and replacement of exhaust fan, steel body AC single Phase 230V of size 300m sweep with, blades, and frame and louvers along with all electrical wire connection complete all as specified and as directed.
Repair and replacement of ceiling fan, AC single Phase. 230V of size 1200mm sweep with, blades, and frame along with all electrical wire connection complete all as specified and as directed.
Repair and replacement of exhaust fan made of sturdy Engineering plastic body complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 300m complete all as specified and as directed. Note: Unserviceable Items to be deposited in MES store in BER procedure.
Repair and replacement of exhaust fan made of sturdy Engineering plastic body complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 250mm complete all as specified and as directed. Note: Unserviceable Items to be deposited in MES store in BER procedure.
Repair and replacement of exhaust fan made of sturdy Engineering plastic body complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 200mm complete all as specified and as directed. Note: Unserviceable Items to be deposited in MES store in BER procedure.
S&F in repair Switch piano, flush type single pole, one way 5 Amp 230 V, 50 Hz, AC , complete all as specified and as directed.
Point wiring for one light/ fan/bell point controlled by one switch using 1.5 Sq mm FRLS copper conductor cables (multistanded) PVC insulated and unseathed in Wiring with Copper conductor cables in PVC casing & caping as per site requirement (thickness not less than 1.5mm and 20mm dia), medium grade with sunken boxes & PVC back plate for mounting all type switches, sockets & regulators etc with front plate including supplying and laying PVC insulated unsheathed 1100 volts coppper conductor cable 1.5 Sq mm as earth wire stranded and conected to earth dolly complete all as specified and as directed. Note:- Cutting and making same the wall patchs after laying the wire and conduit using putty, white wash and distamper. The surface should be made smooth using putty and should match exactly with the existing wall finish.
S&F in repairs Ceiling rose, surface bakelite 65x 50mm two to three terminals fixed on PVC Round Block complete all as specified and as directed.
Taking out geyser carefully from its location of any make & capacity 25/35/50Ltrs and dismantling the same for replacement of parts described under items here-in-below and installed with complete repair and re-assembling and installation of complete set to work complete all as specified and as directed. Note :- Labour for taking down and re-fixing all type of spare parts included in this items & all type of Defective parts/glass wool will be measured and paid separately under respective items of BOQ as supply only.
Supply only PVC connection with two Nos of adopter and washer of size 300 mm long suitable for geyser and including all fixing accessories complete all as specified and as directed.
Supply only PVC connection with two Nos of adopter and washer of size 450 mm long suitable for geyser and including all fixing accessories complete all as specified and as directed.
Supply only SS connection heavy duty (steel type) connecting with two Nos of adopter and washer of size 300 mm long suitable for geyser and including all fixing accessories complete all as specified and as directed.
Supply only Head assembly/Apparatus plate heavy duty 18 SWG with rubber gasket of suitable size for 25/35/50 Ltr capacity 9/6 holes geyser of any make complete all as specified and as directed.
Supply only Heating element any type (i.e Cup/ threaded/triangular) 2.0 KW, 220/230 volts (ISI marked) complete all as specified and as directed.
Supply only Heating element complete set for Havells geyser of 2.0 KW, 220/230 volts (ISI marked) complete all as specified and directed.
Supply only Heating element complete set for Bajaj Calanta geyser of 2.0 KW, 220/230 volts (ISI marked) complete all as specified and as directed.
Supply only Heating element complete set for Racold geyser of 2.0 KW, vertical plate type/horizontal triangular type 220/230 volts (ISI marked) complete all as specified and as directed.
Supply only Instant Water heating coil for Geyser, Coil Type, (ISI Marked) 3KW, suitable for 1 ltr to 5 ltr instant geysers complete all as specified and as directed.
Supply only thermostat ranging 60 degree to 90 degree adjustable type, long, Operative on 250 Volts complete all as specified and as directed.
Supply only Safety Plug "Brass" (ISI marked) complete all as specified and as directed.
Supply only Rubber gasket for apparatus plate suitable for any 25/35/50 ltr cap geyser complete all as specified and as directed.
Supply only Element holding clamp suitable for geyser of cap 25/35/50 Ltr complete all as specified and as directed.
Supply only stainless steel inner tank Capacity 25 Ltrs heavy duty (Approx height 304 mm) with SS 304 Grade complete all as specified and as directed.
Suppply only stainless steel inner tank capacity 35 ltr heavy duty (Approx height 396 mm) with SS 304 Grade complete all as specified and as directed.
Supply only stainless steel inner tank capacity 50 Ltr (Approx height 507 mm) with SS 304 Grade complete all as specified and as directed.
Supply only indicator lamp, round/square, green /red as per requirement complete all as specified and as directed.
Supply only PVC insulated Top plug 3 pin 15 Amp (ISI Marked) complete all as specified and as directed.
Suppy only Metal Clad Plug for Geysers 20A 2 Pin, 230V complete all as specified and as directed.
Suppy only Metal Clad Socket for Geysers 20A 2 Pin, 230V complete all as specified and as directed.
Supply only Steel sheet outer body of Geyser suitable for 25/35/50 ltrs capacity complete all as specified and as directed.
Supply only glass wool for Geyser of any Make for capacity 25/35/50 ltrs complete all as specified and directed.
Taking up or down steel water tubing 15 mm/20 mm dia with fitting and for cleaning including refixing/remove from the site complete all as specified and as directed.
Steel water tubing 15 mm dia (medium grade) galvanised with all fittings including short lengths, fixed to wall and ceiling or laid in floor complete with all fitting (such as bends, elbows, Tee, short pieces, connectors, back nuts, diminishing pieces, caps and plugs, unions etc.) complete all as specified and as directed.
Pressure release valve, dead weight type, (ISI marked) complete all as specified and as directed.
Non return valve 15 mm dia pipe brass made (ISI marked) complete all as specified and as directed.
15 mm brass angle valve (ISI marked) complete all as specified and as directed.
15 mm bib tap (ISI marked) complete all as specified and as directed.
GI Fastner bolts including nuts washer off sizes 4/6 Inch suitable for fixing of any capacity geysers as required at site complete all as specified and as directed.
PVC Copper cable flexible 3 core round heavy duty size 40/0.0076 suitable for geyser any capacity complete all as specified and as directed.
Taking down Geysers (cap 25/35/50 ltr), cleaning its dust particles, one coat of synthetic enamel white spray painting ,reassemble the same along with all fittings and hanging the same back to its original position including connecting the wire to socket etc complete all as specified and as directed.
Repair & replacement of electric water heater,storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece etc complete all as specified and as directed. Note: Unserviceable Items to be deposited in MES Store in BER procedure.
Supply only bolts, nut and washers for Geysers complete all as specified and as directed.
Taking down carefully, copper/aluminum point wiring (geyser power point ) complete fitting such as top plug, socket combination, and making good disturbed surfaces of walls floors and ceiling complete all as specified and as directed.
Point wiring for one pin 15 Amp socket outlet on the independent with 2.5 sqmm PVC insulated unsheathed FRLS copper conductor single core multi strand flexible cable and 1.5 Sqmm PVC insulated unsheathed FRLS copper conductor single core cable (green color) as earth lead in and including non metallic rigid PVC casing/non metallic rigid PVC conduit medium grade with all fitting (ISI maked) controlled by one switch inculding CI/MS box of required size & 3 mm thick plastic laminated sheet, making good the distrurbed surfaces to match with the existing specification complete all as specified and as directed.
All as per ser item No 71 above but for 3 pin 20 A socket outlet point controlled by one modular switch 20A on the independent board with 4 sqmm size of copper cable as main and 2.5 sqmm copper cable as earth lead complete all as specified and as directed.
Switch socket combination 15 Amps, 6 pin multipurpose complete all as specified and as directed.
Switch modular type, 1 module, type 20 Amps 230 volts one way complete all as specified and as directed.
Socket outlet, modular type, 2 module, 2-in-1, 20 Amps combined complete all as specified and as directed.
Sheet metal enclosures for DBs when MCBs to be used double door DB SPN 4 way 240 volts with 200 amps rated bus bar complete all as specified and as directed.
Sheet metal enclosures for DBs when MCBs to be used Single door DB SPN 2 way 240 volts with 200 amps rated bus bar complete all as specified and as directed.
MCB Single Pole and neutral 240 Volt any rating from 10 to 40 Amps with rupturing capacity 10 KA including providing thimble for out going cable complete all as specified and as directed.
MCB SP 20 Amp to 32 Amps 240 volts complete all as specified and as directed.
Single pole and neutral enclosure surface mounted 240 volts with 2 pin and earth plug and socket with one single pole MCB 20 Amps complete all as specified and as directed.
De-scaling of geysers tank 25/35/50 ltrs capacity complete all as specified and as directed.
Solar water heating element for any type solar heater of any capacity 3 Kw as required on ground or complete all as specified and as directed.
Repairing the geyser in situ at its location including replacement of spare parts like heating element, thermostat, indicator, fusible safety vent plug, NRV, GI nipple, PVC connection, stop valve, plug top etc. of any make & capacity 25/35/50 Ltrs geyser and testing complete all as specified and directed. Note :- Spare parts like heating element, thermostat, indicator, fusible safety plug, NRV, GI nipple, PVC connection, stop valve, plug top, 15 Amp S/S combined shall be measured and paid saperately under respective items of BOQ as supply only complete all as specified and as directed.
Note:- (a) Contractors representative/Engineer will report to JE E/M/Engr-in-Charge Daily at fore noon and after noon to collect routine/urgent works related to geyser complaints till completion of contract. The work shall be attended by the contractor immediately. The contractor will ensure availability of manpower equipped with all sort of petty items such as insulation tape, screws, nuts, bolts, washers etc. required to accomplish the job. The contractor will also ensure as availability of every type of requisite T&P items to his trades men. All routine/urgent jobs received on job slip will be repaired & got signature of user's and will be deposited to JE E/M with in 24 hrs. In case of any delay in attending the complaint more than 8 hrs after handing over of routine and 2 hrs for urgent works, the contractor shall be liable to pay the penalty.
(b) The penalty shall be applicable to the contractor if the delay is noticed by Engr-in-Charge more than 12 hrs after handing over works of urgent nature to the contractor. The Engr-in-Charge/JE E/M shall handover the slip containing specifications of work to the contractor by lodging the time and signature of contractor be obtained on slip. The contractor shall attend the job immediately and shall report to Engr-in-Charge within 12 hrs. The contractor will keep his tradesmen in stand by for attending any routine/Urgent works from the executive If the nature of job is such that the work can not be completed within period of 12hrs then the facts shall be brought to the notice of the GE/Engr-in-Charge and the period for the working to the complaint shall be decided by the GE/EIC. If the delay is more than twelve hrs period and the GE is not satisfied with the reason for delay then penalty at the rate of Rs. 20 per job shall be deducted from the dues of the contractor. The decision of the Accepting Officer is this regard shall be final and binding.
(c) One logged Complaint slip, is to be treated as One Complaint irrespective of No. of Repairs mentioned in the same.
(d) Contractor to keep his Electrician ready for Urgent Complaint, During odd hours (0600 Hrs to 0900 Hrs and 1700 Hrs to 2200 Hrs) Other than the Regular complaints during working Hrs (0900 Hrs to 1700 Hrs)
(e) Procurement of Security gate passes of the Electrician, will be sole responsibility of the Contractor as per CA provision.
(f) Replacement of unserviceable parts shall be measured and paid for separately under respective items as Supply Only.
(g) On testing after completion of repair, if the proper functioning without leak, not obtained at Engr-in-Charge satisfaction level, the repairing will be re-done by the contractor at his own cost and the cost for the same shall be deemed to be included in the quoted rates.
(h) The contractor shall maintain/open a Workshop and keep his electrician ready during working Hrs (0900 Hrs to 1700 Hrs) for geyser repair, inside MES store Yard so that all the repairing/Descaling/changing parts of geysers will be done in proper manner, MES authorities will not issue any Geysers/winter appliances, any type, for repair puropse to the contractor for his outside workshop.
CITY TOP ELECTRICAL WORKS
ARNABH ASSOCIATES
DEV RAJ MAGOTRA
s l sharma and sons
D P ASSOCIATES
SINGH CONST CO
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .